Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Simulating Long–Term Dynamics of Radiation Belt Electrons Using DREAM3D Model

Here, we compared the performance of DREAM3D simulations in reproducing the long-term radiation belt dynamics observed by Van Allen Probes over the entire year of 2017 with various boundary conditions (BCs) and model inputs. Specifically, we investigated the effects of three different outer boundary conditions, two different low-energy boundary conditions for seed electrons, four different radial diffusion (RD) coefficients (DLL), four hiss wave models, and two chorus wave models from the literature. Using the outer boundary condition driven by GOES data, our benchmark simulation generally well reproduces the observed radiation belt dynamics inside L* = 6, with a better model performance at lower μ than higher μ, where μ is the first adiabatic invariant. By varying the boundary conditions and inputs, we find that: (a) The data-driven outer boundary condition is critical to the model performance, while adding in the data-driven seed population doesn't further improve the performance. (b) The model shows comparable performance with DLL from Brautigam and Albert (2000, https://doi.org/10.1029/1999ja900344), Ozeke et al. (2014, https://doi.org/10.1002/2013ja019204), and Liu et al. (2016, https://doi.org/10.1002/2015gl067398), while with DLL from Ali et al. (2016, https://doi.org/10.1002/2016ja023002) the model shows less RD compared to data. (c) The model performance is similar with data-based hiss models, but the results show faster loss is still needed inside the plasmasphere. (d) The model performs similarly with the two different chorus models, but better capturing the electron enhancement at higher μ using the Wang et al. (2019, https://doi.org/10.1029/2018ja026183) model due to its stronger wave power, since local heating for higher energy electrons is under-reproduced in the current model.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the {sup 7}Li(p, n){sup 7}Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

From laser particle acceleration to the synthesis of extremely neutron rich isotopes via the novel fission-fusion mechanism

High-power, short pulse lasers have emerged in the last decade as attractive tools for accelerating charged particles (electrons, ions) to high energies over mm-scale acceleration lengths, thus promising to rival conventional acceleration techniques in the years ahead. In the first part of the article, the principles of laser-plasma interaction as well as the techniques and the current status of the acceleration of electron and ion beams will be briefly introduced. In particular with the upcoming next generation of multi-PW class laser systems, such as the one under construction for the ELI-Nuclear Physics project in Bucharest (ELI-NP), very efficient acceleration mechanisms for brilliant ion beams like radiation pressure acceleration (RPA) come into reach. Here, ultra-dense ion beams reaching solid-state density can be accelerated from thin target foils, exceeding the density of conventionally accelerated ion beams by about 14 orders of magnitude. This unique property of laser-accelerated ion beams can be exploited to explore the scenario of a new reaction mechanism called ‘fission-fusion’, which will be introduced in the second part of the article. Accelerating fissile species (e.g. {sup 232}Th) towards a second layer of the same material will lead to fission both of the beam-like and target-like particles. Due to the close to solid-state density of the accelerated ion bunches, fusion may occur between neutron-rich (light) fission products. This may open an access path towards extremely neutron-rich nuclides in the vicinity of the N=126 waiting point of the astrophysical r process. ‘Waiting points’ at closed nucleon shells play a crucial role in controlling the reaction rates. However, since most of the pathway of heavy-element formation via the rapid-neutron capture process (r-process) runs in ‘terra incognita’ of the nuclear landscape, in particular the waiting point at N=126 is yet unexplored and will remain largely inaccessible to conventional nuclear reaction schemes even at next-generation radioactive beam facilities, underlining the attractive perspectives offered, e.g., by ELI-NP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hadron Therapy in Latin America

The use of proton and heavy ion beams for radiotherapy is a well established cancer treatment modality in the first world, which is becoming increasingly widespread, due to its clear advantages over conventional photon-based treatments. This strategy is suitable when the tumor is spatially well localized. Also the use of neutrons has tradition. Here Boron Neutron Capture Therapy (BNCT) stands out, though on a much smaller scale, being a promising alternative for tumors which are diffuse and infiltrating. On this sector, so far only nuclear reactors have been used as neutron sources. In this paper we briefly describe the situation in Latin America and in particular we discuss the present status of an ongoing project to develop a folded Tandem-ElectroStatic-Quadrupole (TESQ) accelerator for Accelerator-Based (AB)-Boron Neutron Capture Therapy (BNCT) at the Atomic Energy Commission of Argentina. The project goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the {sup 7}Li(p,n){sup 7}Be reaction. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams to perform BNCT for deep-seated tumors in less than an hour. The machine being currently designed and constructed is a folded TESQ with a terminal at 0.6 MV as a smaller scale prototype. Since the concept is modular the same structure will be used for the 1.2 MV final accelerator.

43 PARTICLE ACCELERATORS↗

Dissociation of O{sub 2} in low pressure glow discharges in He-O{sub 2}, Ne-O{sub 2}, and Ar-O{sub 2} gas mixtures

Low-pressure glow discharges in He, Ne, or Ar gases containing small amounts of O{sub 2} can produce considerable dissociation of O{sub 2} molecules. High-lying metastable states in these noble gases play a predominant role in this process. Due to the difference in energies of metastable states of the noble gas atoms, there is a significant variation in the product states of O atoms created as a result of dissociation. Apparently, for He and Ne, superexcited O{sub 2} molecules are formed through collisions with high-lying metastable states of the noble gases. The superexcited O{sub 2} molecule could either autoionize to form an O{sub 2}{sup +} ion that subsequently captures an electron and dissociates or it could directly dissociate through some curve-crossing interactions yielding at least one atom in highly excited state. However, in the case of Ar, the formation of superexcited O{sub 2} may be possible through a prior creation of Ar{sub 2}{sup +} ion. We report some interesting observations on spectral emissions from O atoms in the three gas mixtures covering transition from 5d, 4d {sup 3,5}D, and 5s {sup 3,5}S, to 3p {sup 3,5}P levels and 4p and 3p {sup 3,5}P to 3s {sup 3,5}S levels. The emission from the b {sup 4}{sigma}{sub g}{sup -}-a {sup 4}{pi}{sub u} system of O{sub 2}{sup +} ions is also reported. In general, populations of the above-stated O and O{sub 2}{sup +} levels are highest in the case of He-O{sub 2} mixture and lowest for the Ar-O{sub 2} mixture. However, the Ne-O{sub 2} mixture appears to strongly populate the 4p {sup 5}P levels, while the Ar-O{sub 2} mixture strongly populates the 3p {sup 3}P levels. The He-O{sub 2} mixture appears to be more efficient among the three gas mixtures considered in dissociating the O{sub 2} molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymptotic normalization of mirror states and the effect of couplings

Assuming that the ratio between asymptotic normalization coefficients of mirror states is model independent, charge symmetry can be used to indirectly extract astrophysically relevant proton capture reactions on proton-rich nuclei based on information on stable isotopes. The assumption has been tested for light nuclei within the microscopic cluster model. In this work we explore the Hamiltonian independence of the ratio between asymptotic normalization coefficients of mirror states when deformation and core excitation is introduced in the system. For this purpose we consider a phenomenological rotor+N model where the valence nucleon is subject to a deformed mean field and the core is allowed to excite. We apply the model to {sup 8}Li/{sup 8}B, {sup 13}C/{sup 13}N, {sup 17}O/{sup 17}F, {sup 23}Ne/{sup 23}Al, and {sup 27}Mg/{sup 27}P. Our results show that, for most studied cases, the ratio between asymptotic normalization coefficients of mirror states is independent of the strength and multipolarity of the couplings induced. The exception is for cases in which there is an s-wave coupled to the ground state of the core, the proton system is loosely bound, and the states have large admixture with other configurations. We discuss the implications of our results for novae.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HYDRODYNAMIC MODELS OF TYPE I X-RAY BURSTS: METALLICITY EFFECTS

Type I X-ray bursts (XRBs) are thermonuclear stellar explosions driven by charged-particle reactions. In the regime for combined H/He-ignition, the main nuclear flow is dominated by the rp-process (rapid proton-captures and {beta}{sup +}-decays), the 3{alpha}-reaction, and the {alpha}p-process (a suite of ({alpha}, p) and (p, {gamma}) reactions). The main flow is expected to proceed away from the valley of stability, eventually reaching the proton drip line beyond A = 38. Detailed analysis of the relevant reactions along the main path has only been scarcely addressed, mainly in the context of parameterized one-zone models. In this paper, we present a detailed study of the nucleosynthesis and nuclear processes powering type I XRBs. The reported 11 bursts have been computed by means of a spherically symmetric (one-dimensional), Lagrangian, hydrodynamic code, linked to a nuclear reaction network that contains 325 isotopes (from {sup 1}H to {sup 107}Te), and 1392 nuclear processes. These evolutionary sequences, followed from the onset of accretion up to the explosion and expansion stages, have been performed for two different metallicities to explore the dependence between the extension of the main nuclear flow and the initial metal content. We carefully analyze the dominant reactions and the products of nucleosynthesis, together with the physical parameters that determine the light curve (including recurrence times, ratios between persistent and burst luminosities, or the extent of the envelope expansion). Results are in qualitative agreement with the observed properties of some well-studied bursting sources. Leakage from the predicted SbSnTe cycle cannot be discarded in some of our models. Production of {sup 12}C (and implications for the mechanism that powers superbursts), light p-nuclei, and the amount of H left over after the bursting episodes will also be discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Directed Synthesis of Nanoporous Carbons from Task-Specific Ionic Liquid Precursors for the Adsorption of CO 2

Postcombustion CO 2 capture has become a key component of greenhouse-gas reduction as anthropogenic emissions continue to impact the environment. In this paper, we report a one-step synthesis of porous carbon materials using a series of task-specific ionic liquids for the adsorption of CO 2 . By varying the structure of the ionic liquid precursor, we were able to control pore architecture and surface functional groups of the carbon materials in this one-step synthesis process leading to adsorbents with high CO 2 sorption capacities (up to 4.067 mmol g -1 ) at 0 °C and 1 bar. Finally, added nitrogen functional groups led to high CO 2 /N 2 adsorption-selectivity values ranging from 20 to 37 whereas simultaneously the interaction energy was enhanced relative to carbon materials with no added nitrogen.

54 ENVIRONMENTAL SCIENCES↗

Endovascular Brachytherapy in the Femoropopliteal Segment Using {sup 192}Ir and {sup 188}Re

This report presents a review of the literature on endovascular brachytherapy (EVBT) after percutaneous transluminal angioplasty (PTA) in the femoropopliteal segment. We summarize the pathophysiological changes induced by PTA and EVBT within the vessel wall, technical considerations regarding various radiation sources and their application, the impact of stents on the radial dose profile, recommendations for dosimetry of beta and gamma sources, results of experimental and clinical trials, and the medication required before, during, and after EVBT. We aim to help to identify patients who are eligible for EVBT, to choose an appropriate technical approach, and to initiate adequate antiplatelet and anticoagulant therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Trapped Excitons in Ionic-Covalent Silver Halide Crystals and Nanostructures: High-Frequency EPR, ESE, ENDOR and ODMR Studies

Silver halides have unique features in solid state physics because their properties are considered to be of borderline nature between ionic and covalent bonding. In AgCl, the self-trapped hole (STH) is centered and partly trapped in the cationic sublattice, forming an Ag 2+ ion inside of a (AgCl 6 ) 4- complex as a result of the Jahn–Teller distortion. The STH in AgCl can capture an electron from the conduction band forming the self-trapped exciton (STE). Recent results of a study of STE by means of high-frequency electron paramagnetic resonance, electron spin echo, electron–nuclear double resonance (ENDOR) and optically detected magnetic resonance (ODMR) are reviewed. The properties of the STE in AgCl crystals, such as exchange coupling, the ordering of the triplet and singlet sublevels, the dynamical properties of the singlet and triplet states, and the hyperfine interaction with the Ag and Cl (Br) nuclei are discussed. Direct information about the spatial distribution of the wave function of STE unpaired electrons was obtained by ENDOR. From a comparison with the results of an ENDOR study of the shallow electron center and STH, it is concluded that the electron is mainly contained in a hydrogen-like 1s orbital with a Bohr radius of 15.1 ± 0.6 Å , but near its center the electron density reflects the charge distribution of the hole. The hole of the STE is virtually identical to an isolated STH center. For AgCl nanocrystals embedded into the KCl crystalline matrix, the anisotropy of the g-factor of STE and STH was found to be substantially reduced compared with that of bulk AgCl crystals, which can be explained by a considerable suppression of the Jahn–Teller effect in nanoparticles. A study of ODMR in AgBr nanocrystals in KBr revealed spatial confinement effects and allowed estimating the nanocrystal size from the shape of the ODMR spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision measurement of relative γ-ray intensities from the decay of 61Cu

A discrepancy, well outside reported uncertainties, has been observed between the accepted and measured values of the intensity ratio of the two strongest γ-ray following 61 Cu β + decay. This discrepancy has significant impact since the nat Ni(d,x) 61 Cu reaction has historically been one of only a few IAEA recommendations for use as a deuteron flux monitor and a considerable number of published cross sections measured in ratio to that beam monitor cross section may depend on the choice of either the first or second strongest ray in those calculations. To determine the magnitude of this error most precisely, over a hundred separate measurements of the 283 keV to 656 keV γ-ray emission ratio were collected from seven experiments and a variety of detectors and detection geometries. A weighted average of all these measurements indicates an error in the value listed in the Nuclear Data Sheets of 11% in either the primary or second-highest intensity γ-ray of 61 Cu, potentially introducing an 11% error in 61 Cu production cross section measurements, cross sections using nickel activation as a deuteron beam current monitor, or in dose rates when 61 Cu is used in nuclear medicine. General agreement with the Data Sheets with ten other intensity ratios suggests the most probable error is in the secondary (656 keV) emission, which accordingly should be updated from 10.8% to 9.69%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uptake of chloride and carbonate ions by calcium monosulfoaluminate hydrate

Decommissioning of old nuclear reactors may produce waste streams containing chlorides and carbonates, including radioactive {sup 36}Cl{sup -} and {sup 14}CO{sub 3}{sup 2-}. Their insolubilization by calcium monosulfoaluminate hydrate was investigated. Carbonates were readily depleted from the solution, giving at thermodynamic equilibrium monocarboaluminate, monocarboaluminate + calcite, or calcite only, depending on the initial ratio between the anion and calcium monosulfoaluminate hydrate. Chloride ions reacted more slowly and were precipitated as Kuzel's salt, Kuzel's and Friedel's salts, or Friedel's salt only. Rietveld refinement of X-Ray powder diffraction patterns was successfully used to quantify the phase distributions, which were compared to thermodynamic calculations. Moreover, analysing the lattice parameters of Kuzel's salt as a function of its chloride content showed the occurrence of a restricted solid solution towards the sulfate side with general formula 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}xCaCl{sub 2}{center_dot}(1 - x)CaSO{sub 4}{center_dot}(12 - 2x){center_dot}H{sub 2}O (0.36 {<=} x {<=} 0.50).

36 MATERIALS SCIENCE↗

Mass spectrometry structural analysis of intrinsically disordered phosphoproteins

Phosphorylation is a ubiquitous protein modification that is known to play important roles in many biological phenomena including cell signaling, the opening and closing of membrane protein channels, and even triggering of amyloid protein aggregation. Despite the effects phosphorylation has on protein function, the impact phosphorylation has on the structure of proteins is not well understood. Here, to determine how phosphorylation affects the structure of proteins, top-down mass spectrometry (TD-MS) and ion mobility-mass spectrometry (IM-MS) were performed on various phosphorylated proteins and their dephosphorylated proteoforms. TD-MS with collision- and electron-based fragmentation techniques was utilized to locate phosphorylation sites on the intrinsically disordered amyloid proteins β-casein and α-synuclein. TD-MS also provided evidence that alkaline phosphatase dephosphorylates β-casein from the N-terminus to the C-terminus. Furthermore, IM-MS of common phosphorylated proteins such as β-casein, α-casein, ovalbumin, and phosvitin indicates that phosphorylation promotes compaction of protein structure in denaturing as well as native conditions. Increases in abundance of more compact conformers are also observed when the disease related amyloid protein α-synuclein is phosphorylated at serine 129. We interpret the increased abundance of more compact conformers when proteins are phosphorylated as evidence that salt bridges form between negatively charged phosphates and positively charged residues, which alters protein structure. Salt bridge formation due to phosphorylation could be a mechanism for regulating protein function and be responsible for many of the phenomena observed in nature.

Amyloid proteins↗

Hypofractionated Boost With High-Dose-Rate Brachytherapy and Open Magnetic Resonance Imaging-Guided Implants for Locally Aggressive Prostate Cancer: A Sequential Dose-Escalation Pilot Study

Purpose: To evaluate the feasibility, tolerance, and preliminary outcome of an open MRI-guided prostate partial-volume high-dose-rate brachytherapy (HDR-BT) schedule in a group of selected patients with nonmetastatic, locally aggressive prostatic tumors. Methods and Materials: After conventional fractionated three-dimensional conformal external radiotherapy to 64-64.4 Gy, 77 patients with nonmetastatic, locally aggressive (e.g., perineural invasion and/or Gleason score 8-10) prostate cancer were treated from June 2000 to August 2004, with HDR-BT using temporary open MRI-guided {sup 192}Ir implants, to escalate the dose in the boost region. Nineteen, 21, and 37 patients were sequentially treated with 2 fractions of 6 Gy, 7 Gy, and 8 Gy each, respectively. Neoadjuvant androgen deprivation was given to 62 patients for 6-24 months. Acute and late toxicity were scored according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring system. Results: All 77 patients completed treatment as planned. Only 2 patients presented with Grade >=3 acute urinary toxicity. The 3-year probability of Grade >=2 late urinary and low gastrointestinal toxicity-free survival was 91.4% +- 3.4% and 94.4% +- 2.7%, respectively. Rates of 3-year biochemical disease-free survival (bDFS) and disease-specific survival were 87.1% +- 4.1% and 100%, respectively. Conclusions: Boosting a partial volume of the prostate with hypofractionated HDR-BT for aggressive prostate cancer was feasible and showed limited long-term toxicity, which compared favorably with other dose-escalation methods in the literature. Preliminary bDFS was encouraging if one considers the negatively selected population of high-risk patients in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary Symptom Flare in 712 {sup 125}I Prostate Brachytherapy Patients: Long-Term Follow-Up

Purpose: To describe the late transient worsening of urinary symptoms ('urinary symptom flare') in 712 consecutive prostate brachytherapy patients, associated predictive factors, association with rectal and urinary toxicity, and the development of erectile dysfunction. Methods and Materials: Patients underwent implantation between 1998 and 2003 (median follow-up, 57 months). International Prostate Symptom Score (IPSS), Radiation Therapy Oncology Group (RTOG) toxicity, and erectile function data were prospectively collected. Flare was defined as an increase in IPSS of >=5 and of >=8 points greater than the post-treatment nadir. The relationships between the occurrence of flare and the patient, tumor, and treatment characteristics were examined. The Cox proportional hazards method was used to test individual variables and the multivariate models. Results: The incidence of flare was 52% and 30% using the flare definition of an IPSS of >=5 and >=8 points greater than the postimplant nadir, respectively. Of the patients with symptoms, 65% had resolution of their symptoms within 6 months and 91% within 1 year. Flares most commonly occurred 16-24 months after implantation. On multivariate analysis, a greater baseline IPSS and greater maximal postimplant IPSS were the predictors of flare, regardless of the flare definition used. Androgen suppression was a predictor for fewer flares (IPSS >=5). Diabetes and prostate edema predicted for more frequent flares (IPSS >=8). Patients with flare had a greater incidence of RTOG Grade 3 urinary toxicity and RTOG Grade 2 or greater rectal toxicity. No association was found between erectile dysfunction and the occurrence of flare. Conclusion: Urinary symptom flare is a common, transient phenomenon after prostate brachytherapy. A greater baseline IPSS and maximal postimplant IPSS were the strongest predictive factors. Flare was associated with a greater incidence of late RTOG Grade 3 urinary toxicity and greater rate of late RTOG Grade 2 or greater rectal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes Following Iodine-125 Monotherapy for Localized Prostate Cancer: The Results of Leeds 10-Year Single-Center Brachytherapy Experience

Purpose: This study reports the 10-year experience of permanent brachytherapy monotherapy at a single UK center. Methods and Materials: Between March 1995 and September 2004, 1,298 patients underwent trans-rectal ultrasound (TRUS) planned transperineal brachytherapy delivering 145 Gy using I-125. No patient received supplemental external beam; 44.2% received neoadjuvant hormones. In 688, CT postimplant dosimetry was available. Outcome data were analyzed in terms of overall survival (OS), disease specific survival (DSS), and PSA relapse-free survival (PSA-RFS). Results: The mean age was 62.9 (range, 34-83) years. Median follow-up was 4.9 years (range, 2.03-11.7 years). OS and DSS were 85% and 95%, respectively, at 10 years. Twenty-one patients died from prostate cancer (1.6%) and 34 (2.5%) from unrelated causes. Seventy-four (5.7%) developed evidence of clinical failure. Overall PSA-RFS was 79.9% and 72.1% at 10 years (American Society for Therapeutic Radiology and Oncology [ASTRO] and Nadir+2 definitions, respectively). Higher presenting PSA or Gleason score and use of neoadjuvant hormones were associated with an increased risk of biochemical failure (p <0.01). Biochemical control was achieved in 86.4%, 76.7%, and 60.6% (ASTRO) and 72.3%, 73.5%, and 57.6% (Nadir+2) of patients in low-, intermediate-, and high-risk groups, respectively. Biochemical control was achieved in 88% of patients with D{sub 90} >=140 Gy and in 78% of patients with D{sub 90} <140 Gy (p <0.01). Conclusions: I-125 brachytherapy alone achieved excellent rates of medium-term biochemical control in both low- and selected intermediate-risk localized prostate cancer patients. Postimplant dosimetry improved with experience and longer follow-up, confirming the relationship of D{sub 90} with biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗