Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic load model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupling Microstructural Evolution Simulations to Material Property Degradation Predictions for Plasma-Facing Materials

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500 C to 1500 C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 D/m^2-s. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗

Connect microstructure evolution to property degradation with validated simulation

Reliable material performance is required for plasma-facing material (PFM) candidates. Previous research has shown that plasma and neutron radiation exposure induces microstructural changes in PFMs; changes in thermal and electrical conductivities and in material hardening and embrittlement were also observed after neutron irradiation. These material property changes will negatively impact the performance of the PFMs in a fusion reactor. Despite the well-known connection between material microstructure, properties, and performance, there is a need for validated modeling capabilities connecting PFM property degradation with microstructural evolution under fusion-relevant conditions. We are developing a simulation capability to couple plasma-induced microstructural evolution to material property degradation. Our approach relies on deliberate mapping between individual simulation models and experimental characterization for validation. The open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) software was used for this simulation capability development. A MOOSE phase-field model was coupled with the cluster dynamics code, Xolotl, to predict microstructural evolution. Microstructure characterization techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), and laser scanning confocal microscopy (LSCM) are used to validate these microstructural evolution simulations. Calculation of thermal and electrical conductivities with first principles simulations was performed for bulk material and for grain boundaries; these results are used within MOOSE models to calculate effective thermal and electrical conductivities as a function of grain characteristics. Thermoreflectance and four-probe techniques were employed to measure the thermal and electrical conductivities, respectively. A MOOSE crystal plasticity model was adapted to predict microstructure-sensitive deformation behavior, and X-ray diffraction (XRD) was used to collect bulk dislocation density data for validation. After individual simulation validation, these models are coupled to predict material property changes resulting from plasma exposure. We focused here on an experimental design to emphasize the separate effects of moderate thermal loads and plasma exposure using tungsten. Annealing of tungsten was performed under a protective environment for temperatures ranging from 500$^o$C to 1500$^o$C. The plasma exposure was completed in the Tritium Plasma Experiment at Idaho National Laboratory under a deuterium flux of 1e22 $\frac{D}{m^2s}$. This incremental approach is employed to build confidence in the modeling capability: separate-effects tests ensure that the models capture key mechanisms from single environmental conditions before predicting PFM property degradation under combined loads. We will show our early results from coupling these simulation models to predict PFM property changes from microstructural evolution. Comparisons of the simulation results with preliminary validation data will be discussed.

36 - MATERIALS SCIENCE↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

Bayesian blacksmithing: discovering thermomechanical properties and deformation mechanisms in high-entropy refractory alloys

Finding alloys with specific design properties is challenging due to the large number of possible compositions and the complex interactions between elements. This study introduces a multi-objective Bayesian optimization approach guiding molecular dynamics simulations for discovering high-performance refractory alloys with both targeted intrinsic static thermomechanical properties and also deformation mechanisms occurring during dynamic loading. The objective functions are aiming for excellent thermomechanical stability via a high bulk modulus, a low thermal expansion, a high heat capacity, and for a resilient deformation mechanism maximizing the retention of the BCC phase after shock loading. Contrasting two optimization procedures, we show that the Pareto-optimal solutions are confined to a small performance space when the property objectives display a cooperative relationship. Conversely, the Pareto front is much broader in the performance space when these properties have antagonistic relationships. Density functional theory simulations validate these findings and unveil underlying atomic-bond changes driving property improvements.

36 MATERIALS SCIENCE↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An investigation of shock-induced phase transition in soda-lime glass

There exists a large body of evidence from experiments and molecular dynamics simulations to suggest the occurrence of phase transitions in soda-lime glass (SLG) and other silica glasses subject to shock compression to pressures above 3 GPa. In light of these findings, the current work investigated the existence of phase transition in SLG using shock and release experiments. The experiments employed symmetric SLG–SLG impact to achieve complete unloading to zero stress after shock compression to stresses in the range of 3–7 GPa. The stress–strain response and the Lagrangian release wave speed behavior of SLG obtained from these experiments are seen to reveal a mismatch between the loading and unloading paths of the pressure–strain curve for the material, which serves as compelling evidence for the occurrence of a shock-induced phase transition in the material at relatively low pressures. Furthermore, the release wave speed vs strain data obtained from experiments were used to construct a methodology for modeling the shock and release behavior of SLG. Lastly, this scheme implemented in numerical simulations was able to capture the release behavior of shock compressed SLG, for which a robust and satisfactory model was previously unavailable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗

A Study of Wake Characteristics of Marine Turbine Arrays: Preprint

As the marine energy industry continues to develop and installations grow from single turbines to small arrays and larger farms, understanding and predicting wake behavior using modeling tools is necessary for array design and optimization. The wake characteristics of upstream turbines, including velocity deficit, wake swirling, tip vortices, wake shape and direction, and flow recovery, influence the inflow conditions experienced by downstream turbines in an array and, subsequently, affect the individual turbine loading and power generated by the array. These wake characteristics are influenced by many factors, including site geography, inflow shear profile, turbulence, waves, the strength of the current resource, gravitational forces, storm surges, and seasonal effects like temperature and wind conditions. Efficient array modeling tools that capture these wake effects and resulting turbine-to-turbine interactions need to be developed to optimize farm layouts and design individual turbines for operation within arrays. Unlike the wind industry, the marine energy research community is largely limited to the use of either numerical tools or tank/flume testing to understand marine turbine wake interactions. This paper will investigate recent advances in numerical and experimental marine turbine wake modeling, with a focus on recent publications and on both axial-flow and cross-flow marine turbines. A summary of recent research on these topics is provided. Additionally, a demonstration of turbine wake interactions using computational fluid dynamics is presented.

marine hydrokinetic turbine↗

Octane Requirements of Lean Mixed-Mode Combustion in a Direct-Injection Spark-Ignition Engine

Here, this study investigates the octane requirements of a hybrid flame propagation and controlled autoignition mode referred to as mixed-mode combustion (MMC), which allows for strong control over combustion parameters via a spark-initiated deflagration phase. Due to the throughput limitations associated with both experiments and 3-D computational fluid dynamics calculations, a hybrid 0-D and 1-D modeling methodology was developed, supported by experimental validation data. This modeling approach relied on 1-D, two-zone engine simulations to predict bulk in-cylinder thermodynamic conditions over a range of engine speeds, compression ratios, intake pressures, trapped residual levels, fueling rates, and spark timings. Those predictions were then transferred to a 0-D chemical kinetic model, which was used to evaluate the autoignition behavior of fuels when subjected to temperature–pressure trajectories of interest. Finally, the predicted autoignition phasings were screened relative to the progress of the modeled deflagration-based combustion in order to determine if an operating condition was feasible or infeasible due to knock or stability limits. The combined modeling and experimental results reveal that MMC has an octane requirement similar to modern stoichiometric spark-ignition engines in that fuels with high research octane number (RON) and high octane sensitivity (S) enable higher loads. Experimental trends with varying RON and S were well predicted by the model for 1000 and 1400 rpm, confirming its utility in identifying the compatibility of a fuel’s autoignition behavior with an engine configuration and operating strategy. However, the model was not effective in predicting (nor designed to predict) operability limits due to cycle-to-cycle variations, which experimentally inhibited operation of some fuels at 2000 rpm. Putting the operable limits and efficiency from MMC in the context of a state-of-the-art engine, the MMC showed superior efficiencies over the range investigated, demonstrating the potential to further improve fuel economy.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling resistance to the broadly neutralizing antibody PGT121 in people living with HIV-1

PGT121 is a broadly neutralizing antibody in clinical development for the treatment and prevention of HIV-1 infection via passive administration. PGT121 targets the HIV-1 V3-glycan and demonstrated potent antiviral activity in a phase I clinical trial. Resistance to PGT121 monotherapy rapidly occurred in the majority of participants in this trial with the sampled rebound viruses being entirely resistant to PGT121 mediated neutralization. However, two individuals experienced long-term ART-free viral suppression following antibody infusion and retained sensitivity to PGT121 upon viral rebound. Here, we develop mathematical models of the HIV-1 dynamics during this phase I clinical trial. We utilize these models to understand the dynamics leading to PGT121 resistance and to identify the mechanisms driving the observed long-term viral control. Our modeling highlights the importance of the relative fitness difference between PGT121 sensitive and resistant subpopulations prior to treatment. Specifically, by fitting our models to data, we identify the treatment-induced competitive advantage of previously existing or newly generated resistant population as a primary driver of resistance. Finally, our modeling emphasizes the high neutralization ability of PGT121 in both participants who exhibited long-term viral control.

60 APPLIED LIFE SCIENCES↗

Efficacy of vibro-impact energy harvesting absorbers on controlling dynamical systems under vortex-induced vibrations and base excitation

Here this study investigates improving the efficacy of an energy harvesting absorber's ability to control a structure under vortex-induced vibrations, base excitation, and a combination of the two by including mechanical amplitude stoppers. The nonlinear reduced-order model is developed through modifying trilinear spring models to represent the impact forces, a modified van der Pol oscillator to represent the forcing due to the vortex-induced vibrations and using the Euler-Lagrange principle to express the equations of motion. It is seen that a soft stopper stiffness and a 5mm gap performs the most effectively of increasing the power generated from the absorber while still greatly reducing the primary structure's amplitude. By changing the stopper's location towards the middle of the energy harvesting absorber, the large effects of the impact forces are reduced and improves the efficacy of medium and hard stopper stiffnesses to generate near the amount of power the soft stopper does, while greatly improving the control of the primary structure. When the system is under combined loadings, the large oscillations of the synchronization region cause the effective configuration to be that of a 27.5 mm gap with soft stiffnesses. The results shows that medium stiffness stoppers with small gaps generate large aperiodic regions due to the high impact force. When the oscillations are close to the stoppers, the beating phenomenon is observed and is not overpowered by the vibro-impact force.

16 TIDAL AND WAVE POWER↗

Supersaturation, buoyancy, and deep convection dynamics

Motivated by recent discussions concerning differences of convective dynamics in polluted and pristine environments, the so-called convective invigoration in particular, this paper provides an analysis of factors affecting convective updraft buoyancy, such as the in-cloud supersaturation, condensate and precipitation loading, and entrainment. We use the deep convective period from simulations of daytime convection development over land discussed in our previous publications. An entraining parcel framework is used in the theoretical analysis. We show that for the specific case considered here, finite (positive) supersaturation noticeably reduces pseudo-adiabatic parcel buoyancy and cumulative convective available potential energy (cCAPE) in the lower troposphere. This comes from keeping a small fraction of the water vapor in a supersaturated state and thus reducing the latent heating. Such a lower-tropospheric impact is comparable to the effects of condensate loading and entrainment in the idealized parcel framework. For the entire tropospheric depth, loading and entrainment have a much more significant impact on the total CAPE. For the cloud model results, we compare ensemble simulations applying either a bulk microphysics scheme with saturation adjustment or a more comprehensive double-moment scheme with supersaturation prediction. We compare deep convective updraft velocities, buoyancies, and supersaturations from all ensembles. In agreement with the parcel analysis, the saturation-adjustment scheme provides noticeably stronger updrafts in the lower troposphere. For the simulations predicting supersaturation, there are small differences between pristine and polluted conditions below the freezing level that are difficult to explain by standard analysis of the in-cloud buoyancy components. By applying the piggybacking technique, we show that the lower-tropospheric buoyancy differences between pristine and polluted simulations come from a combination of temperature (i.e., latent heating) and condensate loading differences that work together to make polluted buoyancies and updraft velocities slightly larger when compared to their pristine analogues. Overall, the effects are rather small and contradict previous claims of a significant invigoration of deep convection in polluted environments.

54 ENVIRONMENTAL SCIENCES↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flattening the Radial Temperature Profile across the Transformational Challenge Reactor Core

The Transformational Challenge Reactor (TCR) program is demonstrating an agile development approach to advanced nuclear reactor design, which has traditionally utilized a linear design process. In leveraging artificial intelligence, additive manufacturing, advanced materials, and cutting-edge modeling and simulation, the TCR program aims to minimize the high cost and lengthy deployment timelines now standard in the nuclear industry. Within a relatively short period of time, a robust and mature advanced gas-cooled reactor was iteratively designed under the TCR program, using these cutting-edge technologies. The TCR is a 3 MWt gas-cooled microreactor fueled with uranium nitride (UN) tristructural isotropic (TRISO) fuel particles. Though manufactured via traditional means, these UN TRISO particles are loaded into additively manufactured silicon carbide (SiC) cans [4]. Once loaded with TRISO particles, the SiC cans are densified using a chemical vapor infiltration process. The additively manufactured SiC enables significantly more freedom in the design of the fuel form than could ever be achieved using traditionally manufactured SiC. The helium coolant, pressurized to 5 MPa, enters the core at 300°C and nominally exits it at 500°C. Typically, the most thermally limiting components in any reactor design are the fuel assemblies in the core center. To provide a wide thermal margin in these central fuel assemblies, the flow may be biased toward the center of the core to more effectively cool these fuel assemblies with more power deposition and flatten the core’s radial temperature distribution. An analytical fluid model of the TCR core was developed to explore methods for biasing the flow away from the cooler outer fuel assemblies and towards the hotter inner ones. Higher-fidelity models developed in STAR-CCM+ 2020.3.1, a computational fluid dynamics code, were then utilized to verify the analytical model’s findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-X-point radiation and its dynamics in up/down asymmetry in plasma detachment regimes in Wendelstein 7-X

In Wendelstein 7-X (W7-X), stable plasma detachment in ECRH hydrogen plasmas is routinely achieved with the standard magnetic configuration, containing five magnetic islands in the scrape-off layer (SOL). Plasma detachment induced by intrinsic carbon impurities is characterized by a high radiation fraction (ƒ rad ) with significantly reduced divertor heat load and particle flux. In this work, we present the radiation dynamics during the detached plasma (DP) phase, such as the shift of radiation zones in radial and poloidal directions towards the X-points as ƒ rad increases (∼0.6–0.9), as well as the penetration of the radiation layer into the confinement region in the deep DP phase with ƒ rad approaching unity. In particular, a structure of multi-X-point radiation (multi-XPR) with an up/down asymmetry in the DP phase is highlighted, which is revealed by bolometer tomography and is further confirmed by video diagnostics. The multi-XPR structure forms helical 3D bands aligned with W7-X field periodicity. Field reversal experiments show that the brightest XPR displaces between the upper and lower SOL regions, suggesting the E× B drift effects. This paper presents the multi-XPR structure observed in the W7-X plasma in detail for the first time. A simplified model considering the influence of the poloidal E× B drift ( V d ) on the impurity flow in the SOL shows that the downstream drift toward the target or target shadow region ( V d < 0) decreases the impurity content, while the upstream drift toward the LCFS ( V d > 0) increases the impurity content. On this basis, the poloidal drift potentially leads to an up/down asymmetry of impurity density in the SOL despite the symmetry magnetic topology. The dynamics of the up/down asymmetry in the multi-XPR structure is also related to the magnitude V d /D (normalized to the impurity diffusivity), with an additional effect owing to the radial inward shift of the emission zone. These results provide new insights into impurity-induced detachment dynamics and provide a basis for improving 3D modeling of impurity transport, which typically does not consider drifts.

E × B drift↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗