Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “differential sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Influence of sediment resuspension on deep-ocean Pa-231 and Th-230 cycling: A PROGRESS REPORT

The naturally-occurring particle-reactive radionuclides protactinium-231 (231Pa) and thorium-230 (230Th) are used as tracers of a variety of oceanic processes, both at present and in the past. Most notably, the sediment 231Pa/230Th ratio has been used to infer changes in the Atlantic Meridional Overturning Circulation over the last (de)glaciation. However, recent measurements along the U.S. GEOTRACES North Atlantic transect (GA03) revealed two features which are at odds with current understanding about 231Pa and 230Th behaviour in the ocean: (i) a sharp decrease in dissolved 231Pa and 230Th activities with depth below 2000-4000 m and (ii) very large particulate 231Pa and 230Th activities near the bottom, at a number of stations between the New England continental shelf and Bermuda. Concomitant measurements of particulate matter concentration and potential temperature showed that both features are associated with the benthic nepheloid layer (BNL) and the bottom mixed layer (BML) that are present at these stations. Here we develop and apply a simplified model of the exchange of particles, 231Pa, and 230Th between the BNL and the upper sediment, to explore the extent to which the radionuclide anomalies observed near the bottom at a number of GA03 stations can be explained by local sediment resuspension. We find that the model can broadly reproduce the observed anomalies at two stations where samples for radionuclide analyses were collected near the seafloor. Sensitivity tests with the model show that the 231Pa/230Th ratio of particles in the BML and the sediment varies by a factor of 3 as the sediment resuspension rate fluctuates within a range consistent with observational estimates. The modelled variability is comparable to the spatial variability of 231Pa/230Th of suspended particles in the modern North Atlantic and to the variability of Atlantic sediment 231Pa/230Th records across the last (de)glacial period. Two factors are found to contribute to the modelled sensitivity of the sediment 231Pa/230Th to sediment resuspension rate: the vertical turbulent mixing in the BML and the differential scavenging intensity of Pa and Th due to variation in particle concentration. Overall, our study indicates that the exchange of material between the BNL and the upper sediment can affect the particulate 231Pa/230Th ratio in the bottom water and the sediment, which may complicate the use of sediment 231Pa/230Th as a palaeoceanographic tracer.

particle-reactive radionuclides↗

Calcined Polyethyleneimine-Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).

Shumski, Alexander↗

Thermal compensating mount

The main objective is to provide a device for maintaining the alignment integrity of an alignment sensitive component over a wide range of temperatures. A thermal compensating mount is presented. A cylindrical extension is integrally formed to the alignment sensitive component. Both the extension and component share the same coefficient of thermal expansion. The cylindrical extension is placed into a mounting structure which has a diameter greater than that of the extension. An adhesive secures the cylindrical extension to the mount. The difference between the diameters of the cylindrical extension and the cylindrical receptacle is such that the differential thermal expansion across the extension and the receptacle edges is exactly compensated for by the thermal compensation of the adhesive between them. Accordingly, the alignment sensitive component does not change position when subjected to temperature variations. One application of this invention is laser optical-path folding prisms, which are fixed to the mounting surface by a small amount of epoxy adhesive.

Jalink, Antony, Jr.↗

MC performance study for an early $v_μ$ charged-current inclusive analysis with MicroBooNE

This note describes an analysis performed on Monte Carlo data to evaluate the sensitivity of MicroBooNE for an early ν µ charged-current inclusive cross section measurement. Such an analysis is intended to be done using the first three months of Booster Neutrino Beam data. The event selection is entirely based on an automated event reconstruction. The Monte Carlo prediction for a flux-integrated and single differential cross section measurement with an approximate estimation of statistical and systematic uncertainties for the MicroBooNE detector as designed is presented. This allows the comparison of the sensitivity of MicroBooNE to theory and other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

Zirconium Scattering Sensitivity in Neutron Transport Calculations of Multiplying Systems [Slides]

This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Insulin receptor substrate 1 expression enhances the sensitivity of 32D cells to chemotherapy-induced cell death

The adapters IRS1 and IRS2 link growth factor receptors to downstream signaling pathways that regulate proliferation and survival. Both suppress factor-withdrawal-induced apoptosis and have been implicated in cancer progression. However, recent studies suggest IRS1 and IRS2 mediate differential functions in cancer pathogenesis. IRS1 promoted breast cancer proliferation, while IRS2 promoted metastasis. The role of IRS1 and IRS2 in controlling cell responses to chemotherapy is unknown. To determine the role of IRS1 and IRS2 in the sensitivity of cells to chemotherapy, we treated 32D cells lacking or expressing IRS proteins with various concentrations of chemotherapeutic agents. We found that expression of IRS1, in contrast to IRS2, enhanced the sensitivity of 32D cells to chemotherapy-induced apoptosis. When IRS2 was expressed with IRS1, the cells no longer showed enhanced sensitivity. Expression of IRS1 did not alter the expression of pro- and anti-apoptotic proteins; however, 32D-IRS1 cells expressed higher levels of Annexin A2. In 32D-IRS1 cells, IRS1 and Annexin A2 were both located in cytoplasmic and membrane fractions. We also found that IRS1 coprecipitated with Annexin A2, while IRS2 did not. Decreasing Annexin A2 levels reduced 32D-IRS1 cell sensitivity to chemotherapy. These results suggest IRS1 enhances sensitivity to chemotherapy in part through Annexin A2. -- Highlights: Black-Right-Pointing-Pointer IRS1 enhanced the sensitivity of 32D cells to chemotherapy-induced apoptosis. Black-Right-Pointing-Pointer This sensitivity is abrogated by the expression of IRS2. Black-Right-Pointing-Pointer Expressing IRS1 in 32D cells increased levels of Annexin A2. Black-Right-Pointing-Pointer Both IRS1 and Annexin A2 were located in cytoplasmic and membrane fractions. Black-Right-Pointing-Pointer Decreasing Annexin A2 in 32D-IRS1 cells abated their sensitivity to chemotherapy.

60 APPLIED LIFE SCIENCES↗

MID-INFRARED PHOTOMETRIC ANALYSIS OF MAIN BELT ASTEROIDS: A TECHNIQUE FOR COLOR-COLOR DIFFERENTIATION FROM BACKGROUND ASTROPHYSICAL SOURCES

The Spitzer Space Telescope routinely detects asteroids in astrophysical observations near the ecliptic plane. For the galactic or extragalactic astronomer, these solar system bodies can introduce appreciable uncertainty into the source identification process. We discuss an infrared color discrimination tool that may be used to distinguish between solar system objects and extrasolar sources. We employ four Spitzer Legacy data sets, the First Look Survey-Ecliptic Plane Component (FLS-EPC), SCOSMOS, SWIRE, and GOODS. We use the Standard Thermal Model to derive FLS-EPC main belt asteroid (MBA) diameters of 1-4 km for the numbered asteroids in our sample and note that several of our solar system sources may have fainter absolute magnitude values than previously thought. A number of the MBAs are detected at flux densities as low as a few tens of {mu}Jy at 3.6 {mu}m. As the FLS-EPC provides the only 3.6-24.0 {mu}m observations of individual asteroids to date, we are able to use this data set to carry out a detailed study of asteroid color in comparison to astrophysical sources observed by SCOSMOS, SWIRE, and GOODS. Both SCOSMOS and SWIRE have identified a significant number of asteroids in their data, and we investigate the effectiveness of using relative color to distinguish between asteroids and background objects. We find a notable difference in color in the IRAC 3.6-8.0 mm and MIPS 24 {mu}m bands between the majority of MBAs, stars, galaxies, and active galactic nuclei, though this variation is less significant when comparing fluxes in individual bands. We find median colors for the FLS-EPC asteroids to be [F(5.8/3.6), F(8.0/4.5), F(24/8)] = (4.9 {+-} 1.8, 8.9 {+-} 7.4, 6.4 {+-} 2.3). Finally, we consider the utility of this technique for other mid-infrared observations that are sensitive to near-Earth objects, MBAs, and trans-Neptunian objects. We consider the potential of using color to differentiate between solar system and background sources for several space-based observatories, including Warm Spitzer, Herschel, and WISE.

79 ASTRONOMY AND ASTROPHYSICS↗

All-trans retinoic acid combined with 5-Aza-2 Prime -deoxycitidine induces C/EBP{alpha} expression and growth inhibition in MLL-AF9-positive leukemic cells

Highlights: Black-Right-Pointing-Pointer We tested whether ATRA and 5-Aza affect AML cell differentiation and growth. Black-Right-Pointing-Pointer Cell differentiation and growth arrest were induced in MLL-AF9-expressing cells. Black-Right-Pointing-Pointer Increased expression of C/EBP{alpha}, C/EBP{epsilon}, and PU.1 were also observed. Black-Right-Pointing-Pointer MLL-AF4/AF5q31-expressing cells are less sensitive to ATRA and 5-Aza. Black-Right-Pointing-Pointer Different MLL fusion has distinct epigenetic properties related to RA pathway. -- Abstract: The present study tested whether all-trans retinoic acid (ATRA) and 5-Aza-2 Prime -deoxycitidine (5-Aza) affect AML cell differentiation and growth in vitro by acting on the CCAAT/enhancer binding protein {alpha} (C/EBP{alpha}) and c-Myc axis. After exposure to a combination of these agents, cell differentiation and growth arrest were significantly higher in human and murine MLL-AF9-expressing cells than in MLL-AF4/AF5q31-expressing cells, which were partly associated with increased expression of C/EBP{alpha}, C/EBP{epsilon}, and PU.1, and decreased expression of c-Myc. These findings indicate that MLL-AF9-expressing cells are more sensitive to ATRA and 5-Aza, indicating that different MLL fusion proteins possess different epigenetic properties associated with retinoic acid pathway inactivation.

60 APPLIED LIFE SCIENCES↗

Sensitivity of C-Band Polarimetric Radar-Based Drop Size Distribution Measurements to Maximum Diameter Assumptions

The estimation of rain drop size distribution (DSD) parameters from polarimetric radar observations is accomplished by first establishing a relationship between differential reflectivity (Z(sub dr)) and the central tendency of the rain DSD such as the median volume diameter (D0). Since Z(sub dr) does not provide a direct measurement of DSD central tendency, the relationship is typically derived empirically from rain drop and radar scattering models (e.g., D0 = F[Z (sub dr)] ). Past studies have explored the general sensitivity of these models to temperature, radar wavelength, the drop shape vs. size relation, and DSD variability. Much progress has been made in recent years in measuring the drop shape and DSD variability using surface-based disdrometers, such as the 2D Video disdrometer (2DVD), and documenting their impact on polarimetric radar techniques. In addition to measuring drop shape, another advantage of the 2DVD over earlier impact type disdrometers is its ability to resolve drop diameters in excess of 5 mm. Despite this improvement, the sampling limitations of a disdrometer, including the 2DVD, make it very difficult to adequately measure the maximum drop diameter (D(sub max)) present in a typical radar resolution volume. As a result, D(sub max) must still be assumed in the drop and radar models from which D0 = F[Z(sub dr)] is derived. Since scattering resonance at C-band wavelengths begins to occur in drop diameters larger than about 5 mm, modeled C-band radar parameters, particularly Z(sub dr), can be sensitive to D(sub max) assumptions. In past C-band radar studies, a variety of D(sub max) assumptions have been made, including the actual disdrometer estimate of D(sub max) during a typical sampling period (e.g., 1-3 minutes), D(sub max) = C (where C is constant at values from 5 to 8 mm), and D(sub max) = M*D0 (where the constant multiple, M, is fixed at values ranging from 2.5 to 3.5). The overall objective of this NASA Global Precipitation Measurement Mission (GPM/PMM Science Team)-funded study is to document the sensitivity of DSD measurements, including estimates of D0, from C-band Z(sub dr) and reflectivity to this range of D(sub max) assumptions. For this study, GPM Ground Validation 2DVD's were operated under the scanning domain of the UAHuntsville ARMOR C-band dual-polarimetric radar. Approximately 7500 minutes of DSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSD's were then used as input to a T-matrix model for computation of polarimetric radar moments at C-band. All necessary model parameterizations, such as temperature, drop shape, and drop fall mode, were fixed at typically accepted values while the D(sub max) assumption was allowed to vary in sensitivity tests. By hypothesizing a DSD model with D(sub max) (fit) from which the empirical fit to D0 = F[Z(sub dr)] was derived via non-linear least squares regression and a separate reference DSD model with D(sub max) (truth), bias and standard error in D0 retrievals were estimated in the presence of Z(sub dr) measurement error and hypothesized mismatch in D(sub max) assumptions. Although the normalized standard error for D0 = F[Z(sub dr)r] can increase slightly (as much as from 11% to 16% for all 7500 DSDs) when the D(sub max) (fit) does not match D(sub max) (truth), the primary impact of uncertainty in D(sub max) is a potential increase in normalized bias error in D0 (from 0% to as much as 10% over all 7500 DSDs, depending on the extent of the mismatch between D(sub max) (fit) and D(sub max) (truth)). For DSDs characterized by large Z(sub dr) (Z(sub dr) > 1.5 to 2.0 dB), the normalized bias error for D0 estimation at C-band is sometimes unacceptably large (> 10%), again depending on the extent of the hypothesized D(sub max) mismatch. Modeled errors in D0 retrievals from Z(sub dr) at C-band are demonstrated in detail and comparedo similar modeled retrieval errors at S-band and X-band where the sensitivity to D(sub max) is expected to be less. The impact of D(sub max) assumptions to the retrieval of other DSD parameters such as Nw, the liquid water content normalized intercept parameter, are also explored. Likely implications for DSD retrievals using C-band polarimetric radar for GPM are assessed by considering current community knowledge regarding D(sub max) and quantifying the statistical distribution of Z(sub dr) from ARMOR over a large variety of meteorological conditions. Based on these results and the prevalence of C-band polarimetric radars worldwide, a call for more emphasis on constraining our observational estimate of D(sub max) within a typical radar resolution volume is made

Carey, Lawrence D.↗

Measurements of W + W - + ≥ 1 jet production cross-sections in pp collisions at $ \sqrt{s} $ = 13 TeV with the ATLAS detector

Fiducial and differential cross-section measurements of W + W - production in association with at least one hadronic jet are presented. These measurements are sensitive to the properties of electroweak-boson self-interactions and provide a test of perturbative quantum chromodynamics and the electroweak theory. The analysis is performed using proton-proton collision data collected at $ \sqrt{s} $ = 13 TeV with the ATLAS experiment, corresponding to an integrated luminosity of 139 fb -1 . Events are selected with exactly one oppositely charged electron-muon pair and at least one hadronic jet with a transverse momentum of p T > 30 GeV and a pseudorapidity of |η| < 4.5. After subtracting the background contributions and correcting for detector effects, the jet-inclusive W + W - + ≥ 1 jet fiducial cross-section and W + W - + jets differential cross-sections with respect to several kinematic variables are measured. These measurements include leptonic quantities, such as the lepton transverse momenta and the transverse mass of the W + W - system, as well as jet-related observables such as the leading jet transverse momentum and the jet multiplicity. Limits on anomalous triple-gauge-boson couplings are obtained in a phase space where interference between the Standard Model amplitude and the anomalous amplitude is enhanced.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Z boson plus jets events using variables sensitive to double-parton scattering in pp collisions at 13 TeV

Double-parton scattering is investigated using events with a Z boson and jets. The Z boson is reconstructed using only the dimuon channel. The measurements are performed with proton-proton collision data recorded by the CMS experiment at the LHC at s√ = 13 TeV, corresponding to an integrated luminosity of 35.9 fb -1 collected in the year 2016. Differential cross sections of Z+ ≥1 jet and Z+ ≥2 jets are measured with transverse momentum of the jets above 20 GeV and pseudorapidity |η| < 2.4. Several distributions with sensitivity to double-parton scattering effects are measured as functions of the angle and the transverse momentum imbalance between the Z boson and the jets. The measured distributions are compared with predictions from several event generators with different hadronization models and different parameter settings for multiparton interactions. The measured distributions show a dependence on the hadronization and multiparton interaction simulation parameters, and are important input for future improvements of the simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scanning tunneling shot-noise spectroscopy in Kondo systems

Using a large- N theory in combination with the Keldysh nonequilibrium Green's function formalism, we investigate the current, differential conductance, zero-frequency shot noise, and Fano factor as measured by scanning tunneling shot-noise spectroscopy (STSNS) using a scanning tunneling microscope (STM) near single Kondo impurities and in Kondo lattices. We show that the Fano factor F exhibits a characteristic bias dependence arising from Kondo screening that is similar to the Kondo resonance observed in the differential conductance. Moreover, the line shape of F is strongly dependent on the ratio of the tunneling amplitudes for electron tunneling from the STM tip into the conduction band and electronic levels of the magnetic adatoms. We demonstrate that the Fano factor can be enhanced or suppressed due to interference effects and as such, is not only a sensitive probe for the correlation effects arising from Kondo screening, but also for quantum interference between tunneling electrons. We identify a correlation between the form of the differential conductance and the Fano factor that could be tested in future STSNS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of Therapy Response to Transarterial Radioembolization for Liver Metastases by Means of Post-treatment MRI-Based Texture Analysis

IntroductionTo determine whether post-treatment magnetic resonance imaging (MRI)-based texture analysis of liver metastases (LM) may be suited predicting therapy response to transarterial radioembolization (TARE) during follow-up.Materials and MethodsThirty-seven patients with LM treated by TARE (mean age 63.4 years) between January 2006 and December 2014 were identified in this retrospective feasibility study. They underwent dynamic contrast-enhanced and hepatocellular phase MRI after TARE (mean 2.2 days). Response was evaluated on follow-up imaging scheduled in intervals of 3 months (median follow-up, 7.3 months) based on response evaluation criteria in solid tumors 1.1 (RECIST 1.1). Results of texture analysis [mean, standard deviation, skewness (s), kurtosis (k), entropy and uniformity] were compared between patients with progressive disease (PD) and patients with stable disease (SD), partial or complete response (PR/CR). Receiver operating characteristics including the area under the curve (AUC) and cutoff values including the sensitivity and specificity were calculated.ResultsAccording to RECIST 1.1, 24 patients (64.9%) had PD, 8 SD (21.6%) and 5 PR (13.5%). MRI-based texture analysis showed an earlier differentiation between patients with and without PD when compared with RECIST 1.1. Median k (2.88 vs. 2.35) in arterial phase MRI and median s (0.48 vs. 0.25) and k (2.85 vs. 2.25) in venous phase MRI were significantly different (p < 0.05). The AUC for k derived from arterial phase MRI was 0.73 (cutoff = 2.55, sensitivity = 0.83, specificity = 0.62) (p < 0.05). The AUC for s and k in venous phase MRI was 0.76 (cutoff = 0.35, sensitivity = 0.71, specificity = 0.85) (p > 0.05) and 0.83 (cutoff = 2.50, sensitivity = 0.75, specificity = 0.85) (p < 0.05).ConclusionThis study indicates the potential of MRI-based texture analysis at arterial and venous phase MRI for the early prediction of PD after TARE. Level of Evidence: IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Explicit Solution to a Certain Non-ELQG Risk-sensitive Stochastic Control Problem

A risk-sensitive stochastic control problem with finite/infinite horizon is studied with a 1-dimensional controlled process defined by a linear SDE with a linear control-term in the drift. In the criterion function, a non-linear/quadratic term is introduced by using the solution to a Riccati differential equation, and hence, the problem is not ELQG (Exponential Linear Quadratic Gaussian) in general. For the problem, optimal value and control are calculated in explicit forms and the set of admissible risk-sensitive parameters is given in a concrete form. As applications, two types of large deviations control problems, i.e., maximizing an upside large deviations probability and minimizing a downside large deviations probability, are mentioned.

97 MATHEMATICS AND COMPUTING↗

Differentiation of duodenal gastrointestinal stromal tumors from hypervascular pancreatic neuroendocrine tumors in the pancreatic head using contrast-enhanced computed tomography

Purpose: To determine useful contrast-enhanced computed tomography (CE-CT) features in differentiating duodenal gastrointestinal stromal tumors (duodenal GISTs) from hypervascular pancreatic neuroendocrine tumors in the pancreatic head (pancreatic head NETs). Methods: Seventeen patients with pathologically confirmed duodenal GISTs and 25 with pancreatic NETs underwent preoperative CE-CT. CT image analysis included tumor size, morphology, and contrast enhancement. Receiver operating characteristic curves were performed, and cutoff values were calculated to determine CT findings with high sensitivity and specificity. Results: CT imaging showed duodenal GISTs with higher frequencies of tumor central location close to the duodenum and a predominantly solid tumor type when compared with pancreatic head NETs (p < 0.05 for both). Duodenal GISTs were larger than pancreatic head NETs (3.3 ± 0.9 cm vs. 2.5 ± 1.1 cm, p = 0.03). Duodenal GISTs had significantly lower CT attenuation values (112.9 ± 17.9HU vs. 137.4 ± 32.1HU, p < 0.01) at the arterial phase and higher CT attenuation values at the delayed phase (94.3 ± 7.9HU vs. 84.9 ± 10.4HU, p < 0.01) when compared with pancreatic head NETs. A CT attenuation value of ≤ 135 HU at the arterial phase (30 s) was 76% sensitive, 94.1% specific, and 83.3% accurate for the diagnosis of duodenal GISTs, while a CT attenuation value of ≥ 89.5 HU at the delayed phase (120 s) was 93.3% sensitive, 81.8% specific, and 76.2% accurate for the diagnosis of duodenal GISTs. Conclusion: Tumor central location, size, texture, and contrast enhancement are valuable characteristics for the differentiation between duodenal GISTs and hypervascular pancreatic head NETs during preoperative examination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT QA: Selecting gamma criteria based on error detection sensitivity

Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose threshold was consistent across all studied combinations of %Diff/DTA. Criteria such as 2%/3 mm and 3%/2 mm with a 50% threshold at 90% pixels passing are shown to be more appropriately sensitive without being overly strict. However, a broadening of the penumbra by as much as 5 mm in the beam configuration was difficult to detect with commonly used criteria, as well as with the previously mentioned criteria utilizing a threshold of 50%. Conclusions: We have introduced the error curve method, an analysis technique which allows the quantitative determination of gamma criteria sensitivity to induced errors. The application of the error curve method using DMLC IMRT plans measured on the ArcCHECK® device demonstrated that large errors can potentially be missed in IMRT QA with commonly used gamma criteria (e.g., 3%/3 mm, threshold = 10%, 90% pixels passing). Additionally, increasing the dose threshold value can offer dramatic increases in error sensitivity. This approach may allow the selection of more meaningful gamma criteria for IMRT QA and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

A solid-state framework for terrestrial upper mantles

A framework is proposed for understanding the upper mantle structure of the terrestrial planets which is based on solid state dislocation processes. It is proposed that the base of the lithosphere on any planet with a Mg-Fe silicate rich upper mantle is defined by the threshold temperatures of low energy dislocation glide systems in olivine and the pyroxenes. This threshold temperature is approximately 1100 to 1200 K and is directly tied to the mobility of olivine and pyroxene dislocations. Using this definition, all terrestrial planets of the Inner Solar System are expected to have mantle lithospheres. Second, the anomalous properties of the asthenosphere in the Earth are related to the rheological properties of an olivine rich differentiate approximately 220 km thick. All of these properties can be the result of the abundant low energy glide systems in olivine which are mobile at temperatures above approximately 1200 K. It is proposed that a true planetary asthenosphere must be both olivine rich and at temperatures above approximately 1200 K. This mode for the asthenosphere does not require partial melting and is therefore less sensitive to the constraints of volatile content in the upper mantle. The thickness of planetary lithospheres is estimated as is maximum thickness of the olivine rich differentiate on each planet. The cooling of the olivine rich layer on Mars (and hence disappearance of the asthenosphere) may coincide with the cessation of global tectonic activity approximately 1 Gyr ago.

Estey, L.↗