Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

PhytoPET, PhytoBeta and PhytoSPECT: Radioisotope Imaging Systems Being Developed for Plant Biology Research

The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility (Jefferson Lab) is developing radioisotope imaging systems designed and constructed to facilitate plant biology studies at the Duke University Phytotron. The imaging systems utilize nuclear medicine imaging methodologies used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) but designed specifically for plant biology. The range of plant shapes and the environmental conditions in plant growth chambers pose a technological challenge. Description: Jefferson Lab is collaborating with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) in the construction and operation of PhytoPET and PhytoBeta (for direct beta particle detection) for plant and/or microbe imaging. The TUNL tandem Van de Graaff accelerator (maximum terminal voltage of 10 MV) has been used to generate 11C and 13N for plant biology research. The PhytoPET and PhytoBeta have been used with 11C as a 11CO2 tracer for plant ecophysiology imaging with corn, poplar, oak and barley utilizing technologies developed for nuclear physics research and nuclear medicine. The imaging detectors are based on position sensitive photomultiplier tubes coupled to scintillators. Additionally, the collaboration is investigating a methodology using single photon emitting radioisotope tracers for imaging the distribution of molecular compounds of interest in the rhizosphere, the interface between root and soil, without disturbing the root or soil habitat. Plans are underway to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots. In addition to a description of the technology an overview will be given of the application of PhytoPET, PhytBeta and PhytoSPECT to plant biology research at Duke University. Conclusions: We have developed and used radioisotope imaging technologies based on PET and SPECT to visualize plant function in changing environments. There are many opportunities to provide radioisotope based imaging tools for plant ecophysiology imaging. Keywords: radioisotope detection, plant biology, carbon-11, accelerator produced isotopes

Weisenberger, Andrew↗

Development of a System for Measuring the Shape of β Spectra Using a Semiconductor Si Detector

A system for the measurement of beta energy spectra has been developed. It is based on a silicon semi-conductor detector operating at liquid nitrogen temperatures, under ultra high-vacuum. Monte-Carlo simulations were made to optimize the detection chamber and the source holder. Descriptions of the electronic and mechanical systems are included, as well as the first measured spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial Field Measurements with the Multisensor Airborne Radiation Survey (MARS) High Purity Germanium (HPGe) Detector Array

Abstract: The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gamma ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. The system is ruggedized and shock mounted for use in a variety of field applications. This paper reports on results from initial field measurements conducted in a truck and on two different boats.

characterization↗

A large hadron electron collider at CERN

This document provides a brief overview of the recently published report on the design of the Large Hadron Electron Collider (LHeC), which comprises its physics programme, accelerator physics, technology and main detector concepts. The LHeC exploits and develops challenging, though principally existing, accelerator and detector technologies. This summary is complemented by brief illustrations of some of the highlights of the physics programme, which relies on a vastly extended kinematic range, luminosity and unprecedented precision in deep inelastic scattering. Illustrations are provided regarding high precision QCD, new physics (Higgs, SUSY) and eletron-ion physics. The LHeC is designed to run synchronously with the LHC in the twenties and to achieve an integrated luminosity of O(100)fb –1 . It will become the cleanest high resolution microscope of mankind and will substantially extend as well as complement the investigation of the physics of the TeV energy scale, which has been enabled by the LHC.

43 PARTICLE ACCELERATORS↗

Direct reactions for astrophysical p-capture rates with ORRUBA and GODDESS

Understanding the nucleosynthesis and energy generation in quiescent and explosive stellar burning requires a detailed understanding of reaction rates on many unstable nuclides. Such reaction rates are often governed by the properties of low-lying, isolated proton resonances. Though direct measurements of resonance strengths are ultimately desired, and are a focus of rare isotope beam facilities worldwide, such tour-de-force experiments must be guided by indirect techniques, in order to know resonance energies, J π assignments, and estimated widths, to inform targeted measurements. Furthermore, some important low-lying resonances may be too weak for direct measurements with radioactive beams, and indirect techniques provide the only practical constraints. Additionally, there has been growing interest in the astrophysical role of isomeric states, which can influence the reaction flow in nucleosynthetic reaction networks, and hence impact the quantitative interpretation of astronomical observables, such as γ-ray signatures, and elemental and isotopic ratios. Properties of single-proton resonances can be obtained by exploiting the selectivity of direct reactions, such as single-nucleon transfer and charge-exchange reactions. Constraining proton-capture rates via direct reactions has been a focus of the astrophysics program at ORNL for over two decades, spurring the development of the ORRUBA and GODDESS detector systems. Herein, a review of recent developments in instrumentation and radioactive beam delivery (including isomeric beam experiments) is presented, along with some specific examples of astrophysically interesting sd-shell nuclides, which have been a target of recent ORRUBA and GODDESS experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10{sup 20} n/cm{sup 2}. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Separation of electrons and pions in the SND detector calorimeter

A method is developed for discriminating between e{sup +}e{sup −} → e{sup +}e{sup −} and e{sup +}e{sup −} → π{sup +}π{sup −} events in the center-of-mass (cms) energy range of 0.5 to 1.0 GeV by energy deposition in the electromagnetic calorimeter of the SND detector using a machine learning algorithm. Identification efficiencies for e{sup +}e{sup −} → e{sup +}e{sup −} and e{sup +}e{sup −} → π{sup +}π{sup −} events are 99.6 and 99.8%, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Single Crystal Chemical Vapor Deposition Diamonds for Detector Applications

Diamond was studied as a possible radiation hard technology for use in future high radiation environments. With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2013, all LHC experiments are planning for detector upgrades which require radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has now been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is installed in all LHC experiments. As a result, this material is now being discussed as an alternative sensor material for tracking very close to the interaction region of the super-LHC where the most extreme radiation conditions will exist. Our work addressed the further development of the new material, single-crystal Chemical Vapor Deposition diamond, towards reliable industrial production of large pieces and new geometries needed for detector applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NOvA muon energy scale systematic

The systematic uncertainty on the correspondence between muon range and energy is developed for the NOvA neutrino experiment. NOvA consists of two detectors, the Near Detector at Fermilab and the Far Detector in northern Minnesota. Total errors are developed for the Near Detector, with its Muon Catcher treated separately, the Far Detector, and all combinations of correlated and uncorrelated errors between these three detectors. The absolute errors for the Near Detector (1.0%), the Far Detector (0.9%), and the fully correlated error shared by them (0.9%) are strongly dominated by Geant4’s treatment of the Bethe density effect. At the Near Detector, the next biggest uncertainty is from stray hits caused by neutron capture pile-up. Other contributions are marginally significant, with the biggest, in descending order, being due to external measurements of the mean excitation energies of elements, detector mass accounting, and modification of energy loss by chemical binding. For the Muon Catcher, the absolute error is expressed as an offset instead of a percentage: 21MeV. The density effect (at higher energies) and neutron capture pile-up (at lower energies) are the strongly dominant errors. The relative error between the Near and Far Detectors is 0.4% and is strongly dominated by neutron capture pile-up at the Near Detector, with a subdominant contribution from detector mass accounting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NOvA Muon Energy Scale Systematic

The systematic uncertainty on the correspondence between muon range and energy is developed for the NOvA neutrino experiment. NOvA consists of two detectors, the Near Detector at Fermilab and the Far Detector in northern Minnesota. Total errors are developed for the Near Detector, with its Muon Catcher treated separately, the Far Detector, and all combinations of correlated and uncorrelated errors between these three detectors. The absolute errors for the Near Detector (1.0%), the Far Detector (0.9%), and the fully correlated error shared by them (0.9%) are strongly dominated by Geant4's treatment of the Bethe density effect. At the Near Detector, the next biggest uncertainty is from stray hits caused by neutron capture pile-up. Other contributions are marginally significant, with the biggest, in descending order, being due to external measurements of the mean excitation energies of elements, detector mass accounting, and modification of energy loss by chemical binding. For the Muon Catcher, the absolute error is expressed as an offset instead of a percentage: 21 MeV. The density effect (at higher energies) and neutron capture pile-up (at lower energies) are the strongly dominant errors. The relative error between the Near and Far Detectors is 0.4% and is strongly dominated by neutron capture pile-up at the Near Detector, with a subdominant contribution from detector mass accounting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the physics impact of next-generation 76 Ge neutrinoless double-beta decay experiments

It was shown that segmentation and pulse-shape discrimination can improve the discovery sensitivity of a next-gen 0vBB-decay experiment by 90%. - However, when practical aspects are considered (such as instrumenting each segment with front-end electronics), the discovery sensitivity is decreased by 19%. - This has extremely important consequences to proposed next-gen experiments since the two active collaborations have strongly advocated the use of segmented detectors for all or part of the experiment. - New germanium detector technology, currently under development, has demonstrated excellent multi-site background rejection capabilities without the complexity of segmentation or complicated PSD algorithms. - The physically-segmented p-type germanium detector technology has proven to be a useful and practical tool in modern nuclear physics. The PSEG technology deserves further development as it has the potential for use in a variety of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Single Crystal Chemical Vapor Deposition Diamonds for Detector Applications

Diamond was studied as a possible radiation hard technology for use in future high radiation environments. With the commissioning of the LHC expected in 2010, and the LHC upgrades expected in 2015, all LHC experiments are planning for detector upgrades which require radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has now been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is installed and operational in all LHC experiments. As a result, this material is now being discussed as an alternative sensor material for tracking very close to the interaction region of the super-LHC where the most extreme radiation conditions will exist. Our work addressed the further development of the new material, single-crystal Chemical Vapor Deposition diamond, towards reliable industrial production of large pieces and new geometries needed for detector applications.

36 MATERIALS SCIENCE↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of A Self Biased High Efficiency Solid-State Neutron Detector for MPACT Applications

Neutron detection is an important aspect of materials protection, accounting, and control for transmutation (MPACT). Currently He-3 filled thermal neutron detectors are utilized in many applications; these detectors require high-voltage bias for operation, which complicates the system when multiple detectors are used. In addition, due to recent increase in homeland security activity and the nuclear renaissance, there is a shortage of He-3, and these detectors become more expensive. Instead, cheap solid-state detectors that can be mass produced like any other computer chips will be developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-element germanium detectors for synchrotron applications

In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗