Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Survival, healing, and swim performance of juvenile migratory sea lamprey ( Petromyzon marinus ) implanted with a new acoustic microtransmitter designed for small eel-like fishes

Background: Little is known about the transformer stage of the parasitic lampreys, a brief but critical period that encompasses juvenile out-migration from rivers to lakes or oceans to begin parasitic feeding. Information about this life stage could have significant conservation implications for both imperiled and invasive lampreys. We investigated tag retention, survival, wound healing, and swim performance of newly transformed sea lamprey (Petromyzon marinus) implanted with a new micro-acoustic transmitter, the eel–lamprey acoustic transmitter (ELAT), in a controlled laboratory environment. Results: The 61-day survival of our tagged subjects was 71%, within the range reported in similar studies of juvenile lampreys. However, survival was significantly lower in the tagged animals (vs control), with no effect statistically attributable to measures of animal length, mass, condition, or population of origin (Great Lakes vs. Atlantic drainage). Mortality in tagged fish was concentrated in the first four days post-surgery, suggesting injury from the surgical process. An unusually long recovery time from anesthesia may have contributed to the increased mortality. In a simple burst swim assay, tagged animals swam significantly slower (– 22.5%) than untagged animals, but were not significantly different in endurance swim tests. A composite wound healing score at day four was a significant predictor of maximum burst swim speed at day 20, and wound condition was related to animal mass, but not length, at the time of tagging. Conclusions: Impairments to survival and swim performance of juvenile sea lamprey implanted with the ELAT transmitter were within currently reported ranges for telemetry studies with small, difficult to observe fishes. Our results could be improved with more refined anesthesia and surgical techniques. The ability to track migratory movements of imperiled and pest populations of parasitic lampreys will improve our ability to estimate vital rates that underlie recruitment to the adult population (growth, survival) and to investigate the environmental factors that regulate the timing and rates of movement, in wild populations.

59 BASIC BIOLOGICAL SCIENCES↗

Natural Resources Assessment for the SNS Second Target Station, Oak Ridge, Tennessee

The US Department of Energy’s Oak Ridge National Laboratory (ORNL) is a leading institution in advanced materials, supercomputing, neutrons, and nuclear science. As a research laboratory managed by UT-Battelle, LLC for DOE, ORNL has national priorities in energy, security, and scientific discovery that necessitate facility improvements and expansions. DOE is also committed to environmental stewardship. The laboratory is located on the ~32,000-acre Oak Ridge Reservation (ORR), much of which is categorized as a National Environmental Research Park and a state Wildlife Management Area. DOE works with the Tennessee Wildlife Resources Agency (TWRA), Tennessee Department of Environment and Conservation (TDEC), US Fish and Wildlife Service (USFWS), US Department of Agriculture, and other agencies to serve as an effective steward of the ORR. Accordingly, project managers must conform to environmental regulations, agreements, and policies at the federal, state, and institutional levels. Per 40 CFR (Code of Federal Regulations) 1508.14, potential effects on research and science education on the National Environmental Research Park represent potential impacts of federal actions. Moreover, federal actions that affect the quantity and quality of hunting opportunities and deer reduction harvest on the Oak Ridge Wildlife Management Area must be considered whenever other aspects of the human environment (as defined by NEPA) are affected. The Spallation Neutron Source (SNS) is a premiere facility at ORNL that provides advanced capabilities in neutron scattering to promote new discoveries and research opportunities in material sciences, physics, chemistry, biological sciences, and others. A conceptual design for a Second Target Station (STS) has been in consideration for several years. The STS is intended to complement and enhance existing ORNL capabilities, notably research and exploration of complex materials. The proposed STS will involve development of existing natural areas on the ORR, which might contain sensitive resources that require mitigation or avoidance in accordance with existing policies and regulation. This report summarizes current knowledge of natural and cultural resources within the STS project area. At the time of this report, the proposed STS project consisted of an operations area comprising 55.4 acres (22.4 ha) and a total review area for potential construction comprising ~224 acres (90.6 ha). The review area is located primarily within forested natural areas of the ORR with minor development in the form of power-line rights-of-way and secondary/graveled roads (Figure 1). The primary goal was to evaluate potential effects on sensitive resources that might result from development of the STS. In addition to onthe-ground surveys during summer 2009 and fall 2019 to summer 2020 by ORNL Natural Resources Management Program and Aquatic Ecology Group staff, this report makes use of historical (pre-1995) and contemporary (1995 to present) data from additional confirmed sources (e.g., TDEC). Likewise, forest conditions were compiled primarily from a 2013 forest inventory effort for Forest Management Compartment 17 and supplemented with limited ground observations in 2019. The individuals who obtained and compiled the data that are presented here are familiar with and routinely assess sensitive resources on the ORR.

54 ENVIRONMENTAL SCIENCES↗

Proactive Assignment Strategy With Human Choice Models for Boosting Pooled Rideshare Service

This study analyzes various human factors considerations in estimating discounts for pooled rideshare trips. The discounts are utilized in an optimization-based rideshare assignment strategy (proactive strategy) and compared against each other, as well as a heuristic strategy attempting to replicate current real-world pooling rates. Simulations within Austin, Texas and Greenville, South Carolina, reveal the proactive strategy’s ability to increase average vehicle occupancy by 0.23 persons/mile in Austin and 0.52 persons/mile in Greenville. A significant ability to decrease trip rejections and increase profitability is also observed. Finally, the strengths of particular combinations of factors are discussed relative to their effectiveness in each region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Calibrated Sodium Data for Preliminary Validation of the SRT Code for Advanced Reactors

Various types of non-light water reactors are currently engaged in the U.S. licensing process. Because of inherent differences compared with well-established large light water reactors, appropriate assessment tools are needed. Specifically, source term analysis, which determines environmental dose impacts from potential accident scenarios, is a crucial part of design and licensing. The U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic source term analysis for advanced reactor deployments. To align with these needs, Argonne National Laboratory has developed the Simplified Radionuclide Transport (SRT) source term analysis code for metal fuel Sodium-cooled Fast Reactors (SFRs) and microreactors. SRT conducts time-dependent radionuclide transport and retention in SFRs for core and ex-core radionuclide source accident sequences. The main objective of SRT is to provide rapid sensitivity and uncertainty analyses, incorporating parametric uncertainties and summarizing probabilistic results. As part of the code validation process, a study focused on the bubble scrubbing module was performed using an experiment recently carried out by the University of Wisconsin-Madison. Based on the analysis, the modeling approach in SRT provides accurate results for small and large aerosols, while slight underprediction of radionuclide aerosol removal are observed for medium sized aerosols. However, the deviation is minor, considering the highly uncertain phenomenon and range of results, and is in the conservative direction. In addition, uncertainty information derived from the experiments is further implemented, reflecting the actual span of parameters, which leads to enhanced agreement with code predictions. The results demonstrate that SRT provides reasonable predictions for the bubble scrubbing process in sodium pool.

Kam, Dong Hoon↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A New Class of SiC Power MOSFETs with Record-Low Resistance

Silicon carbide (SiC) power transistors are used in the main traction inverter of electric vehicles (EVs). Tesla began installing SiC power MOSFETs in 2017, and has now produced 4.8 million EVs containing over 169 million SiC power MOSFETs. Looking ahead, the worldwide EV market is projected to exceed 50 million vehicles per year by 2030 (Reuters, Oct. 25, 2022). This will create a demand for over two billion SiC power MOSFETs per year. Our program aims to double the efficiency of today's commercial power MOSFETs. This will cut the number of MOSFETs per EV in half, reducing cost, simplifying assembly, decreasing weight, and increasing vehicle reliability through reduced parts count. Our approach is to apply innovative design and advanced processing to increase the density of current-controlling channels in SiC power MOSFET. We have developed two new MOSFET devices, each of which increases the channel density by a factor of six over today's best commercial MOSFETs. This required implementing new fabrication processes, creating new device designs, and integrating the processing steps and device designs into a manufacturable technology. In this project we have developed two innovative devices: (i) a novel three-dimensional structure, the "tri-gate MOSFET," and (ii) a deeply-scaled, fully self-aligned trench MOSFET, the "IMOSFET". Both products were experimentally demonstrated during this project and meet the program goals of increased efficiency relative to the current state-of-the art commercial products. In the process we have generated significant IP, with two US patents issued and three applications pending. We have also published three journal articles and given reports on this technology at seven international conferences. The success of this program has led to significant follow-on funding from industry. In May 2023 Purdue University signed a five-year R&D contract with GlobalFoundries to transfer our novel technology to commercial production. With headquarters in Malta, NY, Global Foundries is one of the largest pure-play silicon foundries in the world, with annual revenue of $\$$8.1B. Their SiC foundry will be built around the next-generation 200-mm diameter SiC wafers, which will double the number of die per wafer and reduce per-die production cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resource Recovery for the Wastewater Industry

This information sheet discusses the technology pillar, Resource Recovery, as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater (WW) treatment plants, this document aims to accomplish the following: • Summarize wastewater sludge recovery methods • Summarize biogas production and codigestion methods • Serve as a comprehensive (though not exhaustive) repository for resource recovery for wastewater utilities The Resource Recovery Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater (W/WW) sector when considering implementing energy capture technologies. Additional details on associated energy capture avenues such as combined heat and power (CHP), renewable energy, and inline hydropower from tertiary effluent in W/WW facilities are presented in the Energy Capture Technology Information Sheet.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

1989 Seattle Household Travel Survey Wave 1

The Puget Sound Transportation Panel was initiated in the fall of 1989. The Seattle Household Travel Survey Wave 1, conducted in 1989, was the first wave in a ten-part longitudinal panel survey initiated by the Puget Sound Regional Council to assess the travel patterns of households in the Puget Sound region of Washington state. The panel intended to serve three basic objectives: 1) to be a metropolitan “current population survey” to track changes in employment, work characteristics, household composition, and vehicle availability; 2) to monitor changes in travel behavior and responses to changes in the transportation environment; and 3) to examine changes in attitudes and values as they affect mode choice and travel behavior. This collection contains the first set of panel data for households in King, Kitsap, Pierce, and Snohomish counties. A total of 1,687 households successfully completed a phone survey and returned completed travel diaries for household members age 15 and older. Respondents were instructed to record their mode of transportation, trip purpose, number of vehicle passengers, departure and arrival times, ride fare, and parking costs in a two-day trip diary. Demographic information for this study includes age, gender, education, employment status, and household income.

1Hz data↗

Improving Coal-Fired Plant Performance Through Integrated Predictive and Condition-Based Monitoring Tools

The project demonstrated the ability to improve boiler performance and reliability through the integrated use of condition-based monitoring (CBM) and predictions of the impacts of coal quality on boiler operations at a full-scale coal-fired power plant. The advanced tool developed actively monitors and manages coal quality and overall boiler conditions that maximizes availability and maintains generating capacity while reducing cost. The tool is used to forecast and alert plant operators and engineers about poor boiler conditions which may occur as a result of incoming coal and/or current power plant operating conditions. The Combustion System Performance Indices (CSPI) and CoalTracker (CT) programs predicts fireside performance of the plant including slagging, fouling, erosion, slag flow, strength development (sintering/densification), and slag layer thickness based on the composition of delivered coal. CT program is tailored for each plant and is used to track the coal from the point of delivery to the burner. The most successful application of the CSPI-CT has been at plants where the coal composition is determined through the use of a full stream elemental analyzers based on prompt gamma neutron analysis (PGNAA). The CSPI-CT program information is used by coal procurement, coal mining and plant operations personnel to select and blend coal properties for the best plant performance.

01 COAL, LIGNITE, AND PEAT↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Virtual Blast Furnace - An Integrated High Performance Computing Modeling, Simulation, and Visualization Capability for Steel Manufacturing (Final Report)

Many manufacturing industries require substantial capital and utilize energy intensive processes that involve complex phenomena. One example of such an industry is the steel industry, which is the fourth largest energy consuming industry in the U.S. By harnessing the power of High-Performance Computing (HPC) to enhance current simulation and visualization methods in the steel industry, it should be possible to increase resolution and/or decrease time of these methods by a factor of 1000. In this way, information can be obtained in a time frame that is useful for making business and engineering decisions, optimizing manufacturing processes and, ultimately, improving the completeness of U.S. industries. For example, if coke usage in blast furnaces were optimized such that the average coke rate was reduced from 797 lb/net tonne of hot metal (NTHM) to 604 lb/NTHM, costs could be reduced by $894 million/year. Additionally, members of the steel industry need the flexibility to efficiently operate blast furnaces at a range of production rates in order to meet fluctuating market demands. Large scale parameter studies can be utilized to discover workable operating parameters at a range of production rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design by analysis rules for ASME Section III, Division 5, Class B components

The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

36 MATERIALS SCIENCE↗