Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Optimization of Adaptive Intraply Hybrid Fiber Composites with Reliability Considerations

The reliability with bounded distribution parameters (mean, standard deviation) was maximized and the reliability-based cost was minimized for adaptive intra-ply hybrid fiber composites by using a probabilistic method. The probabilistic method accounts for all naturally occurring uncertainties including those in constituent material properties, fabrication variables, structure geometry, and control-related parameters. Probabilistic sensitivity factors were computed and used in the optimization procedures. For actuated change in the angle of attack of an airfoil-like composite shell structure with an adaptive torque plate, the reliability was maximized to 0.9999 probability, with constraints on the mean and standard deviation of the actuation material volume ratio (percentage of actuation composite material in a ply) and the actuation strain coefficient. The reliability-based cost was minimized for an airfoil-like composite shell structure with an adaptive skin and a mean actuation material volume ratio as the design parameter. At a O.9-mean actuation material volume ratio, the minimum cost was obtained.

Shiao, Michael C.↗

Dynamically controlled crystallization method and apparatus and crystals obtained thereby

A method and apparatus for dynamically controlling the crystallization of proteins including a crystallization chamber or chambers for holding a protein in a salt solution, one or more salt solution chambers, two communication passages respectively coupling the crystallization chamber with each of the salt solution chambers, and transfer mechanisms configured to respectively transfer salt solution between each of the salt solution chambers and the crystallization chamber. The transfer mechanisms are interlocked to maintain the volume of salt solution in the crystallization chamber substantially constant. Salt solution of different concentrations is transferred into and out of the crystallization chamber to adjust the salt concentration in the crystallization chamber to achieve precise control of the crystallization process.

Arnowitz, Leonard↗

Conditioning of Pu-containing radioactive waste generated in the Hot-lab: where are we now - 15400

To achieve an optimal strategy for interim storage and final disposal, solid radioactive waste has to be sorted and treated. This strategy is based on the requirement to reduce the volume of waste designated for long term disposal, mainly for economical and safety reasons. In addition, the radiological limitations for shipping of the waste packages to a disposal site have to be taken into account as well as the improved regulatory requirements for material under IAEA control. In case of the operational Pu-contaminated and -containing waste from the PSI-Hot laboratory in Switzerland, the existing and over years practiced conditioning method needed improvement. The existing authorized specifications of the conditioning process had to be revised for an optimization of the interim-storage and the deep geological disposal. This was done by the PSI Section for Dismantling and Waste Management. The improvement focused on technical aspects as well as improvement of the documentation for the certification by final depositor (Nagra) and the safety authority (ENSI). This work started in 2008. In 2012 ENSI issued an authorization to realize the first conditioning according the new specification, formally as a certification test ('Type Test') prior to final approval by the ENSI. But, although a licensed method by the competent authority is available, modifications could be necessary and new tasks come up. In 2013 the PSI has produced 13 waste-packages as a Type Test. To obtain the legal authorization ('Type Approval'), some open issues ought to be answered. Waste is continuously generated and so the question arises: When will the next conditioning be done and applying which method? (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-H-19A-04: Multichannel CW Ultrasonic Thermometry for Imaging Therapeutic Dose Fields in Water

Purpose: To develop a scalable, multichannel ultrasonic thermometry system suitable for imaging clinical-beam dose distributions in a water phantom. Method: A small, glass-walled rectangular water phantom (15 cm × 20 cm × 30 cm) was filled with distilled water, and two ultrasonic transducers were placed on the outside, against opposing walls, approximately 5 cm below the water line, and were aligned to optimize transmission/reception of ultrasound between them. Two synchronized lock-in amplifiers were connected to the transducers to enable full-duplex operation of two separate ultrasonic frequency channels configured to transmit simultaneously through the same volume of water and thereby provide independent measurements of the temperature-dependent ultrasonic phase lag. Controlled heating of the water via immersed power resistors provided a means to study dependence of measured phase lag on temperature change for both channels; cross-correlation of the phase outputs enabled much smaller temperature fluctuations in the phantom to be used to ascertain the noise floor and achievable temperature resolution. Results: Temperature measurements from both channels, converted from phase measurements via polynomials available in the literature, exhibited the expected linear dependence of ultrasonic phase on temperature change (measured via calibrated thermistor probe). Cross-correlation analysis of phase fluctuations yielded rms noise estimates of approximately 1-2 microKelvin, comparable to that observed in standard water calorimeters. Conclusion: Phase-sensitive detection of cw ultrasound has been shown to provide temperature sensitivity needed for calorimetry of external treatment beams, and the present simple demonstration establishes that multiple channels may be run simultaneously without phase disturbances that currently affect time-of-flight techniques utilizing phase-detection. Immediate plans include doubling the number of sensors, to enable a simple tomographic reconstruction, and to test the system in Clinac x-rays and electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induction Consolidation of Thermoplastic Composites Using Smart Susceptors

This project has focused on the area of energy efficient consolidation and molding of fiber reinforced thermoplastic composite components as an energy efficient alternative to the conventional processing methods such as autoclave processing. The expanding application of composite materials in wind energy, automotive, and aerospace provides an attractive energy efficiency target for process development. The intent is to have this efficient processing along with the recyclable thermoplastic materials ready for large scale application before these high production volume levels are reached. Therefore, the process can be implemented in a timely manner to realize the maximum economic, energy, and environmental efficiencies. Under this project an increased understanding of the use of induction heating with smart susceptors applied to consolidation of thermoplastic has been achieved. This was done by the establishment of processing equipment and tooling and the subsequent demonstration of this fabrication technology by consolidating/molding of entry level components for each of the participating industrial segments, wind energy, aerospace, and automotive. This understanding adds to the nation's capability to affordably manufacture high quality lightweight high performance components from advanced recyclable composite materials in a lean and energy efficient manner. The use of induction heating with smart susceptors is a precisely controlled low energy method for the consolidation and molding of thermoplastic composites. The smart susceptor provides intrinsic thermal control based on the interaction with the magnetic field from the induction coil thereby producing highly repeatable processing. The low energy usage is enabled by the fact that only the smart susceptor surface of the tool is heated, not the entire tool. Therefore much less mass is heated resulting in significantly less required energy to consolidate/mold the desired composite components. This energy efficiency results in potential energy savings of {approx}75% as compared to autoclave processing in aerospace, {approx}63% as compared to compression molding in automotive, and {approx}42% energy savings as compared to convectively heated tools in wind energy. The ability to make parts in a rapid and controlled manner provides significant economic advantages for each of the industrial segments. These attributes were demonstrated during the processing of the demonstration components on this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of carbon contents on intragranular ferrite formed in the V-Ti-N microalloyed steel with a carbon content gradient prepared by controlling the surface decarburization

Highlights: • A method for quick preparation of steels with different carbon contents was provided. • A steel containing carbon in gradient was obtained through surface decarburization. • The effect of carbon contents on IGF nucleation was studied with the new method. - Abstract: The V-Ti-N microalloyed steel with a carbon content gradient was innovatively obtained through surface decarburization. Then, the effect of carbon contents on intragranular ferrite (IGF) formation was studied. With the carbon contents increasing from 0.39% to 0.47% (mass percent), the volume fraction of IGF decreases from 8.2% to 4.6%, but the number of IGF has no significant change. The critical size of IGF nuclei was calculated on the basis of classic heterogeneous nucleation theory. According to the results of calculation and statistics, with the carbon content increasing from 0.39% to 0.47%, the number of IGF nuclei does not decrease significantly. When the carbon content is relatively low, some (Ti, V)(C, N) particles precipitating in austenite matrix may also act as the nuclei of IGF to refine the pearlite-ferrite microstructure.

36 MATERIALS SCIENCE↗

Configuration and design study of manipulator systems applicable to the free flying teleoperator. Volume 1: Executive summary

A preliminary design of a manipulator system, applicable to a free flying teleoperator spacecraft operating in conjunction with the shuttle or tug, is presented. A new control technique is proposed for application to the manipulator system. This technique, a range/azimuth/elevation rate-rate mode, was selected based upon the results of man-in-the-loop simulations. Several areas are identified in which additional emphasis must be placed prior to the development of the manipulator system. The study results in a manipulator system which will provide an effective method for servicing, maintaining, and repairing satellites to increase their useful life.

Tewell, J. R.↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stereotactic Radiosurgery for Brainstem Metastases: An International Cooperative Study to Define Response and Toxicity

Purpose: To pool data across multiple institutions internationally and report on the cumulative experience of brainstem stereotactic radiosurgery (SRS). Methods and Materials: Data on patients with brainstem metastases treated with SRS were collected through the International Gamma Knife Research Foundation. Clinical, radiographic, and dosimetric characteristics were compared for factors prognostic for local control (LC) and overall survival (OS) using univariate and multivariate analyses. Results: Of 547 patients with 596 brainstem metastases treated with SRS, treatment of 7.4% of tumors resulted in severe SRS-induced toxicity (grade ≥3, increased odds with increasing tumor volume, margin dose, and whole-brain irradiation). Local control at 12 months after SRS was 81.8% and was improved with increasing margin dose and maximum dose. Overall survival at 12 months after SRS was 32.7% and impacted by age, gender, number of metastases, tumor histology, and performance score. Conclusions: Our study provides additional evidence that SRS has become an option for patients with brainstem metastases, with an excellent benefit-to-risk ratio in the hands of experienced clinicians. Prior whole-brain irradiation increases the risk of severe toxicity in brainstem metastasis patients undergoing SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas

Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, and IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.

60 APPLIED LIFE SCIENCES↗

Inpatient Opioid Use After Pancreatectomy: Opportunities for Reducing Initial Opioid Exposure in Cancer Surgery Patients

Background: Despite advances in enhanced surgical recovery programs, strategies limiting postoperative inpatient opioid exposure have not been optimized for pancreatic surgery. The primary aims of this study were to analyze the magnitude and variations in post-pancreatectomy opioid administration and to characterize predictors of low and high inpatient use. Methods: Clinical characteristics and inpatient oral morphine equivalents (OMEs) were downloaded from electronic records for consecutive pancreatectomy patients at a high-volume institution between March 2016 and August 2017. Regression analyses identified predictors of total OMEs as well as highest and lowest quartiles. Results: Pancreatectomy was performed for 158 patients (73% pancreaticoduodenectomy). Transversus abdominus plane (TAP) block was performed for 80% (n = 127) of these patients, almost always paired with intravenous patient-controlled analgesia (IV-PCA), whereas 15% received epidural alone. All the patients received scheduled non-opioid analgesics (median, 2). The median total OME administered was 423 mg (range 0–4362 mg). Higher total OME was associated with preoperative opioid prescriptions (p < 0.001), longer hospital length of stay (LOS; p < 0.001), and no epidural (p = 0.006). The lowest and best quartile cutoff was 180 mg of OME or less, whereas the highest and worst quartile cutoff began at 892.5 mg. After adjustment for inpatient team, only epidural use [odds ratio (OR) 0.3; p = 0.04] predicted lowest-quartile OME. Preoperative opioid prescriptions (OR 8.1; p < 0.001), longer operative time (OR 3.4; p = 0.05), and longer LOS (OR 1.1; p = 0.007) predicted highest-quartile OME. Conclusions: Preoperative opioid prescriptions and longer LOS were associated with increased inpatient OME, whereas epidural use reduced inpatient OME. Understanding the predictors of inpatient opioid use and the variables predicting the lowest and highest quartiles can inform decision-making regarding preoperative counseling, regional anesthetic block choice, and novel inpatient opioid weaning strategies to reduce initial postoperative opioid exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrically Injected UV-Visible Nanowire Lasers

There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasers emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.

42 ENGINEERING↗

Final Technical Report for DE-SC0008135, Modulating Thermal Transport Phenomena in Nanostructures via Elastic Strain at Extreme Limits of Strength

Nanoscale materials fabricated with nearly pristine crystal structure are often endowed with ultra-strength behavior, where material failure occurs at a significant fraction of its ideal limit. The thermal conductivity exhibited by such materials is also uniquely affected by the high surface-to-volume ratio at the nanoscale. The juxtaposition of the vastly increased dynamic range of elastic strain available in ultra-strength nanomaterials and altered thermal transport shows promise for tunable thermal properties. This project aims to exploit these properties of high-strength nanostructures to elucidate the coupling between large mechanical strains and thermal conductivity (both electron and phonon) leading to better understanding and control of the thermal performance in these materials. Unique fabrication methods to produce nanosized quasi-defect free single crystals and modern nanomechanical testing will be used to identify the size-dependent dynamic range of elastic strain and understand deformation mechanisms near the ideal limit. Identifying and quantifying thermal transport phenomena as a function of mechanical strain in these nanostructures will open the door to using elastic strain engineering in high-strength nanomaterials to tune thermal transport. The results of these investigations will be used to improve the performance, efficiency, and versatility of advanced thermal management and energy conversion devices with tunable response.

36 MATERIALS SCIENCE↗

Event Detection for Undersampled Electron Microscopy Experiments: A Control Chart Case Study

Real-time systems often consist of high-volume, high-velocity data streams in which making efficient and timely inferences about the data are challenging. In particular, when a user interacts with a real-time system to gain insights, detect events, and make decisions about the system, the rate and amount of information the user is required to process is generally overwhelming. In addition, analytically processing large volumes of data can be computationally expensive and, in real-time, renders traditional inferential methods effectively useless. One approach to mitigate these challenges is to reduce both the amount of information presented to the user and the volume of data placed in the stream. In this manuscript we will describe a method constructed under this approach in addition to the development and deployment of an online tool, Real time Event Detector for Subsampled Images (REDSI), designed to provide feedback on a real-time system by characterizing and detecting events of interest. We will discuss REDSI in the context of scanning transmission electron microscopy (STEM), which is a powerful real-time system that provides high spatial and temporal resolution on nanoscale structures and processes. The data produced by STEM experiments are a stream of images relaying structural, compositional, and dynamic interphase information to scientists in fields ranging from microbiology and neuroscience to materials science and energetics. While REDSI was designed to processes STEM images in real time, we will also discuss other real-time system applications for this methodology.

multivariate statistics, event detection↗

Local Hypothermia as a Radioprotector of the Rectal Wall During Prostate Stereotactic Body Radiation Therapy

Purpose: To compare the single-fraction dose-related incidence of rectal obstruction and/or bleeding in normothermic and hypothermic rectums of a rat model. Methods and Materials: A 1.9-cm length of rectum was irradiated with a single fraction in 57 Sprague-Dawley rats using a dedicated image-guided small animal irradiator and Monte Carlo–based treatment planning system. All rats had a rectal temperature control apparatus placed during irradiation and were stratified to achieve either a normothermic (37°C) or hypothermic (15°C) rectal wall temperature. Radiation was delivered to a 1-cm-diameter cylindrical volume about the cooling device and rectal wall. The radiation dose was escalated from 16 Gy up to 37 Gy to assess the dose response in each arm. The primary endpoint of this study was rectal obstruction and/or bleeding during a follow-up of 180 to 186 days. Histologic scoring was performed on all study rats. Results: Probit analysis showed a dose associated with a 50% incidence of rectal obstruction of 24.6 Gy and 40.8 Gy for normothermic and hypothermic arms, respectively. The occurrence of obstruction and/or bleeding correlated with the posttreatment histologic score for normothermic rats; however, there was no difference in histologic score between normothermic and hypothermic rats at the highest dose levels evaluated. Conclusions: A significant radioprotective effect was observed using local hypothermia during a single large dose of radiation for the functional endpoint of rectal obstruction and/or bleeding. A confirmatory study in a large animal model with anatomic and physiologic similarities to humans is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polarization Control via He-Ion Beam Induced Nanofabrication in Layered Ferroelectric Semiconductors

Rapid advanced in nanoscience rely on continuous improvements of matter manipulation at near atomic scales. Currently, well characterized, robust, resist-based lithography carries the brunt of the nanofabrication process. However, use of local electron, ion and physical probe methods is also expanding, driven largely by their ability to fabricate without the multi-step preparation processes that can result in contamination from resists and solvents. Furthermore, probe based methods extend beyond nanofabrication to nanomanipulation and imaging, vital ingredients to rapid transition to prototyping and testing of layered 2D heterostructured devices. In this work we demonstrate that helium ion interaction, in a Helium Ion Microscope (HIM), with the surface of bulk copper indium thiophosphate CuM III P 2 X 6 (M = Cr, In; X= S, Se), (CITP) results in the control of ferroelectric domains, and growth of cylindrical nanostructures with enhanced conductivity; with material volumes scaling with the dosage of the beam. The nanostructures are oxygen rich, sulfur poor, and with the copper concentration virtually unchanged as confirmed by Energy Dispersive X-ray (EDX). Scanning Electron Microscopy (SEM) imaging contrast as well as Scanning Microwave Microscopy (SMM) measurements suggest enhanced conductivity in the formed particle, whereas Atomic Force Microscopy (AFM) measurements indicate that the produced structures have lower dissipation and a lower Young s modulus.

2D crystals↗

Longitudinal Trajectories of Memory Performance in Patients with Early-Stage Breast Cancer

Background. While breast cancer and its treatments may affect cognition, the longitudinal trajectories of cognition among those receiving differing cancer treatment types remain poorly understood. Prior research suggests hippocampal-prefrontal cortex network integrity may influence cognition, although how this network predicts performance over time remains unclear. Methods. We conducted a prospective trial including 69 patients with early-stage breast cancer receiving adjuvant therapy and 12 controls. Longitudinal cognitive testing was conducted at four visits: pretreatment-baseline, 6-7 months, 14-15 months, and 23-24 months. Cognitive composite scores of episodic memory, executive functioning, and processing speed were assessed at each timepoint. Baseline structural MRI was obtained in a subset of these participants, and hippocampal and prefrontal cortex regional volumes were extracted. Results. Longitudinal linear mixed modeling revealed significant group by time interactions on memory performance, controlling for age and education. Post hoc analyses revealed this effect was driven by patients treated with chemotherapy or chemotherapy plus hormone therapy, who demonstrated the least improvement in memory scores over time. Treatment group did not significantly influence the relationship between time and processing speed or executive functioning. Neither pretreatment hippocampal nor prefrontal volume differed between groups, and there were no significant group by time by baseline regional volume effects on cognition. Conclusion. Patients with early-stage breast cancer treated with chemotherapy or chemotherapy plus hormone therapy benefit less from practice effects seen in healthy controls on memory tests. Loss of longitudinal practice effect may be a new and clinically relevant measure for capturing patients’ experience of cognitive difficulties after treatment.

60 APPLIED LIFE SCIENCES↗