Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Estimation of rate constants of elementary processes - A review of the state of the art.

'Thermochemical kinetics,' the codification and extrapolation of empirical observations, as applied to certain elementary reactions of importance to combustion studies, is described. This approach allows the critical scrutiny of experimental data in areas where sufficient previous data exist, while, at the same time, illuminating those key areas where more experimentation is crucial. It is shown that combination of transition-state theory with an understanding of the molecular basis of entropy puts fairly rigid constraints on the values of the Arrhenius A-factor for most reactions. This, in turn, means that the activation energy is often the key datum that is missing, and that such data can be obtained with some degree of confidence, even from measurements of rate constants at only one temperature. In complex mechanisms, it is often possible to distinguish among alternate pathways and pinpoint key processes.

Golden, D. M.↗

Thermomagnetic recording and magneto-optic playback system having constant intensity laser beam control

A system is developed for maintaining the intensity of a laser beam at a constant level in a thermomagnetic recording and magneto-optic playback system in which an isotropic film is heated along a continuous path by the laser beam for recording. As each successive area of the path is heated locally to the vicinity of its Curie point in the presence of a controlled magnetic field, a magneto-optic density is produced proportional to the amplitude of the controlled magnetic field. To play back the recorded signal, the intensity of the laser beam is reduced and a Faraday or Kerr effect analyzer is used, with a photodetector, as a transducer for producing an output signal.

Lewicki, G. W.↗

An electrical generator with a variable speed input: Constant frequency output

A new type of rotary energy conversion device for obtaining a desired constant frequency output independent of the speed of the prime mover has been developed and tested using the technique of field modulation and solid state alternator output processing. A 10-kilowatt prototype field modulated frequency down converter system was designed, built, and successfully tested. Experimentally obtained performance characteristics are presented.

Allison, H. J.↗

Task 60 test report, evaluation of IRIG-A 21 channel constant bandwith FM multiplexer for shuttle development flight instrumentation

A frequency modulated (FM) multiplexer, consisting of 21 IRIG-A constant bandwidth (CBW) voltage-controlled oscillators (VCO's) was tested to determine its suitability for use in multiplexing 21 data signals which have frequency ranges of dc to 2 kHz. Tests were preformed with the composite signal, consisting of the mixed outputs of the 21 VCO's connected directly to a set of subcarrier discriminators, with the signal recorded on magnetic tape and played back through the discriminators and with the signal transmitted by a frequency-modulated FM S-band radio frequency RF transmitter to a FM receiver and through the subcarrier discriminators. Tape speed flutter was induced to determine the reduction in flutter noise which can be obtained by the tape speed compensation equipment. The RF transmission test included transmitting the composite signal at a nominal RF received signal of -73 dbm and at RF levels of -83 and -86 dbm.

Haddick, C. M.↗

The influence of a constant magnetic field on the coagulatory system of the blood in an experiment

The influence of a constant magnetic field with a strength of 2500 oersteds on the coagulatory system of the blood in rabbits was studied; the animals were subjected to this field for one and five hours. The magnetic field acts on the coagulatory system of the blood after only one hour exposure. Repeated 5-hour exposures cause activation of the anticoagulatory system in the blood and causes distinctive effects on the subsequent changes in the coagulatory system of the blood. It is quite likely that in this instance the adaptational properties of the organism make themselves felt.

Zabrodina, L. V.↗

Change in blood coagulation indices as a function of the incubation period of plasma in a constant magnetic field

The influence of a constant magnetic field (CMF) with a strength of 250 and 2500 oersteds on the recalcification reaction and the tolerance of plasma to heparin was studied as a function of the exposure time of the plasma to the CMF. The maximum and reliable change in the activation of the coagulatory system of the blood was observed after a 20-hour incubation of the plasma in a CMF. As the exposure time increased, the recalcification reaction changed insigificantly; the difference between the mean arithmetic of the experiment and control values was not statistically reliable. The tolerance of the plasma to heparin as a function of the exposure time to the CMF of the plasma was considerably modified, an was statistically reliable.

Yepishina, S. G.↗

Influence of a constant magnetic field on thrombocytes

In an experiment on white mice it was found that a constant electromagnetic field with strength of 250-275 oersteds is biologically active at an exposure of 55 minutes. Qualitative and morphological changes in thrombocytes 1-3 days following exposure reduced their numbers, prolonged blood coagulation time and increased the number of leucocytes.

Meyerova, Y. A.↗

The protective effect of a constant magnetic field

The protective effect of a constant magnetic field sharply reduced spontaneous lysis of E. coli cells when subjected to ultraviolet radiation. A protective effect of a CMF was found in a study of tissue cultures of normally growing cells (kidney epithelium) and cancer cells (cells from a cancer of the larynx). The protective effect of a CMF is also seen in a combined exposure of tissue cultures to X-rays and CMF energy (strength of the CMF was 2000 oersteds with a gradient of 500 oersteds/cm). The data obtained are of interest to experimental oncology (development of new methods of treating malignant tumors).

Sosunov, A. V.↗

Influence of a constant magnetic field on the fibrinogen-fibrin system

The effect of a constant magnetic field with a strength of 2500 oersteds on the fibrinogen-fibrin system was studied in the organism of healthy rabbits with exposure times of 1 and 5 hours. The results obtained indicate disruptions in the stage of conversion of fibrinogen to fibrin and an increase in the amount of fibrinogen.

Matskevichene, V. B.↗

Constant temperature hot wire anemometry data reduction procedure

The theory and data reduction procedure for constant temperature hot wire anemometry are presented. The procedure is valid for all Mach and Prandtl numbers, but limited to Reynolds numbers based on wire diameter between 0.1 and 300. The fluids are limited to gases which approximate ideal gas behavior. Losses due to radiation, free convection and conduction are included.

Klopfer, G. H.↗

Pole-placement with constant gain output feedback

Davison (1970) has demonstrated that it is possible to assign max (m, p) poles of a linear time-invariant controllable and observable multivariable system arbitrarily close to desired locations by using constant gain output feedback. A new proof of Davison's theorem on pole placement is developed, and a system design procedure is described which offers some advantages over Davison's method. It is shown that in some cases more than max (m, p) poles can be assigned arbitrarily, and a least square design procedure is proposed to approximate the desired pole locations when it is not possible to place all the poles.

Sridhar, B.↗

Nearly spherical constant-power detonation waves as driven by focused radiation

An analysis is made of the flow within a three-dimensional explosion, or spark, created in a gas absorbing energy from a steady conical beam of radiation with nearly spherical symmetry. The radiation, typically from an array of lasers with a common focus, is assumed to be very intense and absorbed immediately behind an outwardly advancing strong shock. Departures of the laser power from spherical uniformity, which would result from practical problems of arrangement, are conveniently represented by an ascending series of Legendre polynomials in the polar angle. For nonuniformities of small amplitude, first-order perturbations of the flow field are analyzed in detail. Self-similarity is shown to be retained for zero counter-pressure and power constant with time. For the first five harmonics in power distortion, the resulting fourth-order system of equations is solved numerically for profiles of velocity components, density, pressure, and shock shape. Results are presented graphically.

George, Y. H.↗

Sequential filter design for precision orbit determination and physical constant refinement

Earth-based spacecraft tracking data have historically been processed with classical least squares filtering techniques both for navigation purposes and for physical constant determination. The small, stochastic nongravitational forces acting on the spacecraft are described to motivate the use of sequential estimation as an alternative to the least squares fitting procedures. The stochastic forces are investigated both in terms of their effect on the tracking data and their influence on estimation accuracy. A flexible sequential filter design which leaves the existing trajectory, variational equations, data observable and partial computations undisturbed is described. A detailed filter design is presented that meets the precision demands and flexibility requirements of deep space navigation and of scientific problems.

Curkendall, D. W.↗

ICR study of nonreactive ion-molecule collision rate constants for Cl/-/ and Cr/CO/5/-/

Determination of experimental momentum transfer rate constants for systems of Cl(-) and Cr(CO)5(-) ions by means of an ion cyclotron resonance (ICR) line-broadening technique. It is found that in the pure polarization limit of small ion/large neutral collisions the Langevin ion mobility theory gives good agreement with experimental results. A comparison of isotropic and anisotropic neutral systems suggests that a correction for the anisotropic systems is necessary. Beyond the pure polarization limit the Langevin theory gives poor predictions for ion mobilities. The adjustable parameter, gamma, of the Mason-Schamp (12-6-4) potential function permits unique solution of the ion mobility for Cr(CO)5(-) in a wide range of neutral gases. The large values of gamma obtained for most of these systems imply, in terms of the Mason-Schamp theory, that the r to the minus 6th power contribution to the potential function is significant.

Dymerski, P. P.↗

Variable resistance constant tension and lubrication device

A variable resistance device is described which includes a cylindrical housing having elongated resistance wires. A movable arm having a supporting block carried on the outer end is rotatably carried by the cylindrical housing. An arcuate steel spring member is pivotally supported by the movable arm. A leather wiper member is carried adjacent to one end of the spring steel member, and an electrically conductive surface is carried adjacent to the other end. The supporting block maintains the spring steel member in compression so that a constant pressure is applied to the conductive end of the spring steel member and the leather wiper. The leather wiper is saturated with a lubricating oil for maintaining the resistance wire clean as the movable arm is manipulated.

Smith, H. J.↗

Gravitational clock: A proposed experiment for the measurement of the gravitational constant G

The increased importance and the fundamental significance of accurately measuring the gravitational constant G are discussed along with recent or proposed experimental measurements of G. The method of using mutually gravitating bodies in the clock mode in a drag-free satellite is described. A satellite experiment consisting of the flat-plate spherical mass oscillator proposed combines the mathematical and experimental conveniences most simply. It is estimated that accuracies of 1 part in 1,000,000 are easily obtainable by careful fabrication of parts. The use of cryogenic techniques, thin films, and superconductors allows increased accuracies of two or three orders of magnitude or better. These measurements can be increased to the level of 1 part in 10 to the 11th power at which time-variations, and other variations, in G can be observed.

Smalley, L. L.↗

On the Navier-Stokes equations with constant total temperature

For various applications in fluid dynamics, it is assumed that the total temperature is constant. Therefore, the energy equation can be replaced by an algebraic relation. The resulting set of equations in the inviscid case is analyzed. It is shown that the system is strictly hyperbolic and well posed for the initial value problems. Boundary conditions are described such that the linearized system is well posed. The Hopscotch method is investigated and numerical results are presented.

Gottlieb, D.↗