Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

MO-F-CAMPUS-T-05: Correct Or Not to Correct for Rotational Patient Set-Up Errors in Stereotactic Radiosurgery

Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied to two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.

60 APPLIED LIFE SCIENCES↗

A consumer-centric approach to quantify efficiency of receiving goods purchased via online

Virtual participation in shopping activities has increased exponentially in the past four years compared to the last couple of decades. E-tailing or online shopping offers the convenience of goods reaching a consumer instead of a consumer traveling to a store, but it has downsides like geographical service variability and negative social externalities such as increased energy consumption and emissions. This study proposes a novel approach to quantify e-tailing efficiency from the consumers’ viewpoint. The methodology is innovative in its integration of accessibility theory with energy and cost impedance factors and consideration of delivering and picking up goods purchased via online. The methodology is implemented for the San Francisco Bay Area and is subject to scenarios that see enhancements to various facets of online shopping delivery. Results demonstrate that increasing the frequency of e-commerce deliveries helps improve e-tailing efficiency in rural locations, while improvements in energy and cost aspects of delivery modes are seen to improve e-tailing efficiencies in the central parts of the region. The approach proposed can provide valuable insights on where people have limited benefits from online shopping and how emerging delivery mechanisms can change the quality of the e-commerce experience within a city. This research offers a replicable framework for assessing e-commerce systems in diverse geographic contexts, contributing to the development of equitable and environmentally sustainable urban freight systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Improved Representation of Vegetative Filter Strips in SWAT

Abstract. Vegetative filter strips (VFS) are popular conservation practices installed at the edges of agricultural fields to reduce losses of pollutants from agricultural areas to receiving waterbodies. The recent interest in using VFS areas as multifunctional landscapes necessitates an improved depiction of VFS in simulation models. This study is aimed to enhance the physical representation of VFS in the Soil and Water Assessment Tool (SWAT) to improve the representation of ecohydrologic processes and land management practices in VFS areas. The proposed enhancement enables routing of water, sediment, and nutrients from the source area through the VFS area and makes the infiltrated water and nutrients available for filter crop uptake. The improvements are implemented in SWAT by modifying input files through Matlab scripts and by changing SWAT subroutines to enable routing. The model improvements are tested with three paired watershed studies with and without edge-of-field VFS in central Iowa. The improved model estimated 46% runoff reduction, 91% sediment reduction, 83% total phosphorus reduction, and 54% nitrate reduction with VFS, and these estimates closely matched the measured VFS reductions. The improved model was able to represent increased infiltration, soil moisture, and denitrification in the VFS area, along with accurately capturing crop yields in the source and VFS areas. Overall, the results indicate improved physical representation of VFS in SWAT. Keywords: Conservation measures, Flexible buffer strips, Multifunctional buffers, SWAT model, Vegetative filter strips.

Agriculture↗

COLLABORATIVE RESEARCH: Study of Aerosol Sources and Processing at the GVAX Pantnagar Supersite

This project was part of a collaborative campaign, including the participation of scientists from seven research groups as part of the Winter Intensive Operating Period (January-February 2012) of the Clean Air for London (ClearfLo) campaign at a rural site in Detling, UK, 45 km southeast of central London to study wintertime sources of urban particulate matter. The UW contribution by PI Thornton’s group was to make the first deployment of a chemical ionization mass spectrometer instrument (MOVI-CI-ToFMS) to measure both particle and gas phase organic acids. The new instrument ran nearly continuously during the ClearfLo WINTER IOP at the Detling site, producing a first-ever data set of molecular composition information that can be used for source apportionment and process studies. The UW group published a paper in Environmental Science and Technology and contributed to another (Bohnenstengel et al BAMS 2015) detailing a direct molecular connection between biomass/biofuel burning particles and aerosol light absorption. The ES&T paper (Mohr, et al ES&T 2013) has received 42 citations in just 3 years indicative of its significant impact on the field. These measurements of urban and rural aerosol properties will contribute to improved modeling of regional aerosol emissions, and of atmospheric aging and removal.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Origin and Distribution of Heavy Elements in the CD Groups MKW 4 and AWM 4

At this point, data for MKW4 have been received and those for AWM4 are still awaited. The MKW4 data have been fully analyzed and a complete manuscript is available and in final review by co-authors before submission for refereed publication. The following is a summary of our principal findings: We examined the distribution and properties of the hot gas which makes up the group halo. The inner halo shows some signs of structure, with circular or elliptical beta-models providing a poor fit to the surface brightness profile. This may be evidence of large-scale motion in the inner halo, but we do not find evidence of sharp fronts or edges in the emission. The temperature of the halo declines in the core, with deprojected spectral fits showing a central temperature of approximately 1.3keV compared to approximately 3keV at 250 arcsec. However, cooling flow models provide poor fits to the inner regions of the group and the estimated cooling time of the gas is long except within the central dominant galaxy, NGC4073. Abundance profiles show a sharp increase in the core of the group. We conclude that MKW4 is a fairly relaxed group, which has developed a strong central temperature gradient but not a large-scale cooling flow.

Vrtilek, Jan↗

Evapotranspiration Based Irrigation Trials Examine Water Requirement, Nitrogen Use, and Yield of Romaine Lettuce in the Salinas Valley

Cool season vegetables require adequate soil moisture to assure that maximum yield and quality are achieved. On California’s central coast, where the majority of cool season vegetables are produced in the US, long-term overpumping of irrigation water has reduced groundwater levels and led to environmental degradation. Two evapotranspiration (ET) based irrigation field trials were performed near Salinas CA (USA) to determine if ET-based irrigation scheduling could conserve water while producing romaine lettuce (cv. Sun Valley) of commercially viable yield. Sprinklers were used for seed germination and crop establishment. Four drip irrigation treatments were then imposed using a randomized complete block design with six replications. The CropManage decision support model was used to estimate the full (100%) crop water requirement based mainly on ET replacement. Other treatments included 50% 75% and 150% of the full water requirement. The 100% treatment received 185 mm of water in 2015 and 247 mm in 2016, both of which were well below prior guidance and grower reports. Yields from the 100% and 150% treatments were not significantly different and were similar to industry average, while yields were significantly lower for the 50% and 75% treatments. The 100% treatment had the highest water use efficiency, and the 100% and 150% treatments together had the highest nitrogen recovery efficiency. Irrigation of romaine near the 100% ET replacement level can potentially reduce environmental impacts associated with nitrate leaching and surface runoff.

CropManage decision support system↗

Estimating Need for Palliative External Beam Radiotherapy in Adult Cancer Patients

Purpose: Older surveys and benchmark data from different sources have suggested that 46-53% of all radiotherapy courses were administered with palliative intent. In Sweden, 87 annual palliative treatment courses per 100,000 inhabitants were registered in 2001, mainly for the treatment of bone and brain metastases (95% confidence interval [CI] 85-89). The corresponding number for Norway was 95 (95% CI 93-98) in 2004. New data are lacking, although new systemic treatment options might alter this number. Methods and Materials: We collected prospective data on the use of palliative external beam radiotherapy for adult cancer patients during a 12-month period between 2007 and 2008. All patients (median age 69 years) were treated in one Norwegian county and had unlimited, rapid access to treatment. Efforts were made to account for potential overuse. Results: Most irradiated patients had skeletal target volumes, followed by nonbony thoracic targets and brain metastases. In the present population, 133 annual treatments per 100,000 inhabitants were registered (after correction for overuse, but not accounting for radiosurgery of brain metastases and emerging treatment options; e.g., stereotactic radiotherapy for lung and liver metastases; 95% CI 119-149). Because some patients received simultaneous treatment to different target volumes, the annual number of target volumes amounted to 175 per 100,000 inhabitants (95% CI 161-191). Conclusion: The need for palliative radiotherapy has not decreased and might be greater than previously estimated. In regions with a significantly different cancer incidence, age structure, and other socioeconomic factors than northern Europe, separate analyses should be conducted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dismantling of Loop-Type Channel Equipment of MR Reactor in NRC 'Kurchatov Institute' - 13040

In 2009 the project of decommissioning of MR and RTF reactors was developed and approved by the Expert Authority of the Russian Federation (Gosexpertiza). The main objective of the decommissioning works identified in this project: - complete dismantling of reactor equipment and systems; - decontamination of reactor premises and site in accordance with the established sanitary and hygienic standards. At the preparatory stage (2008-2010) of the project the following works were executed: loop-type channels' dismantling in the storage pool; experimental fuel assemblies' removal from spent fuel repositories in the central hall; spent fuel assembly removal from the liquid-metal-cooled loop-type channel of the reactor core and its placement into the SNF repository; and reconstruction of engineering support systems to the extent necessary for reactor decommissioning. The project assumes three main phases of dismantling and decontamination: - dismantling of equipment/pipelines of cooling circuits and loop-type channels, and auxiliary reactor equipment (2011-2012); - dismantling of equipment in underground reactor premises and of both MR and RTF in-vessel devices (2013-2014); - decontamination of reactor premises; rehabilitation of the reactor site; final radiation survey of reactor premises, loop-type channels and site; and issuance of the regulatory authorities' de-registration statement (2015). In 2011 the decommissioning license for the two reactors was received and direct MR decommissioning activities started. MR primary pipelines and loop-type facilities situated in the underground reactor hall were dismantled. Works were also launched to dismantle the loop-type channels' equipment in underground reactor premises; reactor buildings were reconstructed to allow removal of dismantled equipment; and the MR/RTF decommissioning sequence was identified. In autumn 2011 - spring 2012 results of dismantling activities performed are: - equipment from underground rooms (No. 66, 66A, 66B, 72, 64, 63) - as well as from water and gas loop corridors - was dismantled, with the total radwaste weight of 53 tons and the total removed activity of 5,0 x 10{sup 10} Bq; - loop-type channel equipment from underground reactor hall premises was dismantled; - 93 loop-type channels were characterized, chopped and removed, with radwaste of 2.6 x 10{sup 13} Bq ({sup 60}Co) and 1.5 x 10{sup 13} Bq ({sup 137}Cs) total activity removed from the reactor pool, fragmented and packaged. Some of this waste was placed into the high-level waste (HLW) repository of the Center. Dismantling works were executed with application of remotely operated mechanisms, which promoted decrease of radiation impact on the personnel. The average individual dose for the personnel was 1.9 mSv/year in 2011, and the collective dose is estimated as 0.0605 man x Sv/year. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of Helical I-125 Seed Implant in the Portal Vein

Purpose: To evaluate the feasibility of helical iodine-125 (I-125) seed portal vein implantation. Materials and Methods: Helical I-125 seed implants were placed into the portal vein of healthy pigs through the transjugular (n = 3) or percutaneous transhepatic (n = 3) route. Six pigs received follow-up at 9 weeks after implantation. Blood tests were performed preimplantation, and at 1 and 9 weeks after implantation. Contrast-enhanced computed tomography (CT) and single-photon emission computed tomography combined with CT (SPECT-CT) were acquired after implantation. Post-implantation CT was imported to the treatment planning system (TPS) for dose verification. At 9 weeks after implantation, another CT was performed before histopathological examination. Results: All implantations were successful, and the helical implants were fixed to the portal vein. CT showed no implant migration or portal vein thrombosis. The average dose to 90% of the target volume calculated from TPS was 68.4 Gy. SPECT-CT revealed an irregular isodose around the implant, in which the hottest spot was near the central portal vein lumen. All pigs were in good condition at the 9-week follow-up. Histopathology studies confirmed no portal vein thrombosis. Pigs showed no signs of bleeding, necrosis, or perforation of the peripheral tissue or organs. Intimal hyperplasia was observed at the two ends of the implant. A mild inflammatory response was detected in the bile duct and adjacent liver tissues, yet there was no apparent inflammation of the hepatic arteries. Conclusion: The helical I-125 seed implants can be inserted into the portal veins of healthy pigs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Remote Monitor Alarm System

A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

Stute, Robert A.↗

Phase I Three-Dimensional Conformal Radiation Dose Escalation Study in Newly Diagnosed Glioblastoma: Radiation Therapy Oncology Group Trial 98-03

Purpose: To evaluate in a Phase I trial the feasibility and toxicity of dose-escalated three-dimensional conformal radiotherapy (3D-CRT) concurrent with chemotherapy in patients with primary supratentorial glioblastoma (GBM). Methods and Materials: A total of 209 patients were enrolled. All received 46 Gy in 2-Gy fractions to the first planning target volume (PTV{sub 1}), defined as the gross tumor volume (GTV) plus 1.8 cm. A subsequent boost was given to PTV{sub 2}, defined as GTV plus 0.3 cm. Patients were stratified into two groups (Group 1: PTV{sub 2} <75 cm{sup 3}; Group 2: PTV{sub 2} {>=}75 cm{sup 3}). Four RT dose levels were evaluated: 66, 72, 78, and 84 Gy. Carmustine 80 mg/m{sup 2} was given during RT, then every 8 weeks for 6 cycles. Pretreatment characteristics were well balanced. Results: Acute and late Grade 3/4 RT-related toxicities were no more frequent at higher RT dose or with larger tumors. There were no dose-limiting toxicities (acute Grade {>=}3 irreversible central nervous system toxicities) observed on any dose level in either group. On the basis of the absence of dose-limiting toxicities, dose was escalated to 84 Gy in both groups. Late RT necrosis was noted at 66 Gy (1 patient), 72 Gy (2 patients), 78 Gy (2 patients), and 84 Gy (3 patients) in Group 1. In Group 2, late RT necrosis was noted at 78 Gy (1 patient) and 84 Gy (2 patients). Median time to RT necrosis was 8.8 months (range, 5.1-12.5 months). Median survival in Group 1 was 11.6-19.3 months. Median survival in Group 2 was 8.2-13.9 months. Conclusions: Our study shows the feasibility of delivering higher than standard (60 Gy) RT dose with concurrent chemotherapy for primary GBM, with an acceptable risk of late central nervous system toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency vehicle traffic signal preemption system

An emergency vehicle traffic light preemption system for preemption of traffic lights at an intersection to allow safe passage of emergency vehicles. The system includes a real-time status monitor of an intersection which is relayed to a communications controller for transmission to emergency vehicles as well as to a central dispatch office. The system also provides for audio warnings at an intersection to protect pedestrians who may not be in a position to see visual warnings or for various reasons cannot hear the approach of emergency vehicles. A transponder mounted on an emergency vehicle provides autonomous control so the vehicle operator can attend to getting to an emergency and not be concerned with the operation of the system. Activation of a Code 3 situation provides communications with each intersection being approached by an emergency vehicle and indicates whether the intersection is preempted or if there is any conflict with other approaching emergency vehicles. On-board diagnostics handle various information including heading, speed, and acceleration sent to a communications controller which is transmitted to an intersection and which also simultaneously receives information regarding the status of an intersection.

Bachelder, Aaron D.↗

Dissociation between spontaneously hypertensive (SHR) andWistar–Kyoto (WKY) rats in baseline performance and methylphenidate response on measures of attention, impulsivity and hyperactivity in a Visual Stimulus Position Discrimination Task

The spontaneously hypertensive rat (SHR) is a widely accepted rodent model of Attention Deficit/Hyperactivity Disorder (ADHD), and methylphenidate (MP) is a central nervous systemstimulant that has been shown to have a dose-related positive effect on attention task performance in humans with ADHD. The current study was undertaken to compare SHR to its typical control strain, Wistar-Kyoto(WKY) rats, on the performance of a Visual Stimulus Position Discrimination Task (VSPDT) as well as of the responsiveness of the two rat strains to MP treatment. The rats were initially trained on the VSPDT, in which a light cue was presented randomly at three different cue-light intervals (1 s, 300 ms and 100 ms) over one of two levers, and presses on the lever corresponding to the light cue were reinforced with a food pellet. Once rats reached stable performance, the treatment phase of the study began, during which they received daily intraperitoneal (IP) injections of saline, 2 mg/kg, 5 mg/kg, and 10 mg/kg of MP in a randomized order immediately prior to being tested on the VSPDT. Baseline performance accuracy on the VSPDT did not differ between the groups. Furthermore, a striking strain dissociation was evident in the response of the two strains to treatment; VSPDT performance was substantially disrupted by the 5 and 10 mg/kg dose in the WKY rats but only mildly in the SHR rats. Response omissions were also increased only in WKY rats. Finally, both strains had increased locomotor activity in the operant chamber following MP treatment. These findings point to an important difference in response tendency toMP in the two strains that supports a view that a critical difference between these strains may suggest neurochemical and neuroadaptive differences associated with the behavioral impairments of ADHD.

60 APPLIED LIFE SCIENCES↗

Nonisocentric Treatment Strategy for Breast Radiation Therapy: A Proof of Concept Study

Purpose: To propose a nonisocentric treatment strategy as a special form of station parameter optimized radiation therapy, to improve sparing of critical structures while preserving target coverage in breast radiation therapy. Methods and Materials: To minimize the volume of exposed lung and heart in breast irradiation, we propose a novel nonisocentric treatment scheme by strategically placing nonconverging beams with multiple isocenters. As its name suggests, the central axes of these beams do not intersect at a single isocenter as in conventional breast treatment planning. Rather, the isocenter locations and beam directions are carefully selected, in that each beam is only responsible for a certain subvolume of the target, so as to minimize the volume of irradiated normal tissue. When put together, the beams will provide an adequate coverage of the target and expose only a minimal amount of normal tissue to radiation. We apply the nonisocentric planning technique to 2 previously treated clinical cases (breast and chest wall). Results: The proposed nonisocentric technique substantially improved sparing of the ipsilateral lung. Compared with conventional isocentric plans using 2 tangential beams, the mean lung dose was reduced by 38% and 50% using the proposed technique, and the volume of the ipsilateral lung receiving ≥20 Gy was reduced by a factor of approximately 2 and 3 for the breast and chest wall cases, respectively. The improvement in lung sparing is even greater compared with volumetric modulated arc therapy. Conclusions: A nonisocentric implementation of station parameter optimized radiation therapy has been proposed for breast radiation therapy. The new treatment scheme overcomes the limitations of existing approaches and affords a useful tool for conformal breast radiation therapy, especially in cases with extreme chest wall curvature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-EF-204-08: Dose Efficiency of Added Beam-Shaping Filter with Varied Attenuation Levels in Lung-Cancer Screening CT

Purpose: Added filtration such as tin filter has the potential to improve dose efficiency of x-ray beam in lung-cancer screening CT. However, dose efficiency with added beam filtration is highly dependent on patient attenuation level. In this phantom study, we evaluated the image quality at different tube voltages with and without added tin filter when attenuation level varies. Methods: A 30 x 20 cm anthropomorphic thorax phantom with three added extension rings were used to simulate small (S), medium (M), large (L), and extra-large (XL) adult patients. These phantoms were scanned on a 192-slice CT scanner (Force, Siemens) at 100 and 120kV without tin filtration, and 100 and 150 kV with tin filtration (100Sn and 150Sn), at multiple dose levels at each kV. Images were reconstructed using iterative reconstruction (ADMIRE, Siemens). Radiation dose was measured with a 0.6 cc ion chamber in the middle and peripheral areas of the phantom. Image quality was assessed using mean image noise at uniform areas in the central region and lung. Radiation dose that is required for each kV to match the noise in a routine lung-cancer CT screening technique (120kV, 25 quality reference mAs) was calculated. Results: At each of the four phantom sizes, 100Sn had the lowest noise in both soft tissue and lung. Compared with 120 kV, 100Sn saved 39%–60% dose for the same noise, depending on phantom size. For the XL phantom (50 by 40 cm), 150Sn provided images with the least beam-hardening artifact in peripheral region. Conclusion: For thoracic CT, added tin filtration can provide considerable dose reduction compared with 120 kV. 100Sn provides better dose efficiencies for all phantom sizes, while 150Sn provides better image quality in peripheral region for extra-large patients. Drs.Joel G. Fletcher and Cynthia H. McCollough receive research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗