Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Experimental setup for investigation of nanoclusters at cryogenic temperatures by electron spin resonance and optical spectroscopies

We present the design and performance of an experimental setup for simultaneous electron spin resonance (ESR) and optical studies of nanoclusters with stabilized free radicals at cryogenic temperatures. A gas mixture of impurities and helium after passing through a RF discharge for dissociation of molecules is directed onto the surface of superfluid helium to form the nanoclusters of impurities. A specially designed ESR cavity operated in the TE{sub 011} mode allows optical access to the sample. The cavity is incorporated into a homemade insert which is placed inside a variable temperature insert of a Janis {sup 4}He cryostat. The temperature range for sample investigation is 1.25–300 K. A Bruker EPR 300E and Andor 500i optical spectrograph incorporated with a Newton EMCCD camera are used for ESR and optical registration, respectively. The current experimental system makes it possible to study the ESR and optical spectra of impurity-helium condensates simultaneously. The setup allows a broad range of research at low temperatures including optically detected magnetic resonance, studies of chemical processes of the active species produced by photolysis in solid matrices, and investigations of nanoclusters produced by laser ablation in superfluid helium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual laser holography for in situ measurement of plasma facing component erosion (invited)

A digital holography (DH) surface erosion/deposition diagnostic is being developed for 3D imaging of plasma facing component surfaces in situ and in real time. Digital holography is a technique that utilizes lasers reflected from a material surface to form an interferogram, which carries information about the topology of the surface when reconstructed. As described, dual CO 2 lasers at 9.271 and 9.250 μm wavelengths illuminate the interrogated surface (at a distance of ~1 m) in a region of ~1 cm × 1 cm. The surface feature resolution is ~0.1 mm in the plane of the surface, and the depth resolution ranges from ~0.0001 to ~2 mm perpendicular to the surface. The depth resolution lower limit is set by single-laser and detector optical limitations, while the upper limit is determined by 2π phase ambiguity of the dual-laser synthetic wavelength. Measurements have been made “on the bench” to characterize the single-laser and dual-laser DH configurations utilizing standard resolution targets and material targets that were previously exposed to high flux plasmas in either the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) or the electro-thermal (ET) arc source. Typical DH measurements were made with 0.03 ms integration with an IR camera that can be framed at rates approaching 1.5 kHz. Finally, the DH diagnostic system is progressing toward in situ measurements of plasma erosion/deposition either on Proto-MPEX or the ET arc source.

47 OTHER INSTRUMENTATION↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THERMAL IMAGING OF ACTIVE MAGNETIC REGERNERATOR MCE MATERIALS DURING OPERATION

An active magnetic regenerator (AMR) prototype was constructed that incorporates a Gd sheet into the regenerator wall to enable visualization of the system s thermal transients. In this experiment, the thermal conditions inside the AMR are observed under a variety of operating conditions. An infrared (IR) camera is employed to visualize the thermal transients within the AMR. The IR camera is used to visually and quantitatively evaluate the temperature difference and thus giving means to calculate the performance of the system under the various operating conditions. Thermal imaging results are presented for two differing experimental test runs. Real time imaging of the thermal state of the AMR has been conducted while operating the system over a range of conditions. A 1 Tesla twin-coil electromagnet (situated on a C frame base) is used for this experiment such that all components are stationary during testing. A modular, linear reciprocating system has been realized in which the effects of regenerator porosity and utilization factor can be investigated. To evaluate the performance variation in porosity and utilization factor the AMR housing was constructed such that the plate spacing of the Gd sheets may be varied. Each Gd sheet has dimensions of 38 mm wide and 66 mm long with a thickness of 1 mm and the regenerator can hold a maximum of 29 plates with a spacing of 0.25 mm. Quantitative and thermal imaging results are presented for several regenerator configurations.

Shassere, Benjamin↗

Preliminary design setup and experimental results of laser sintering for use in aerosol jet printing

It is imperative to understand the application of emerging advanced manufacturing techniques to nuclear related capabilities. The Advanced Manufacturing thrust of the In-Pile Instrumentation Initiative seeks to apply techniques such as aerosol jet printing to allow for manufacturing of novel sensor designs. As part of this thrust, a laser sintering system is being developed. The preliminary design allows for benchtop experiments that are controlled with a manual stage. The preliminary results did not appear to achieve sufficient temperatures to sinter the specimen, and temperatures were not accurately measured by the IR camera. A calibration to link silver emissivity with temperature must be performed in order to quantitatively measure temperatures with the IR camera. This calibration will be performed, and a second sintering experiment performed in detail to determine required laser exposure times and temperatures to achieve sintering with the system. Future updates for the system include a higher resolution lens for the IR camera to allow for higher magnification temperature observations, as well as a motorized stage and control framework to link the stage movements to the specimen geometry and desired exposure time during the sintering process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUBARU MID-INFRARED IMAGING OF THE QUADRUPLE LENSES. II. UNVEILING LENS STRUCTURE OF MG0414+0534 AND Q2237+030

We present mid-infrared imaging at 11.7 {mu}m for the quadruple lens systems, MG0414+0534 and Q2237+030, using the cooled mid-infrared camera and spectrometer attached on the Subaru telescope. MG0414+0534 is characterized by a bright pair of lensed images (A1, A2) and their optical flux ratio A2/A1 deviates significantly from the prediction of a smooth-lens model. Q2237+030 is 'the Einstein Cross' being comprised of four lensed images, which are significantly affected by microlensing in a foreground lensing galaxy. Our mid-infrared observations of these lensed images have revealed that the mid-infrared flux ratio for A2/A1 of MG0414+0534 is nearly unity (0.90 {+-} 0.04). We find that this flux ratio is systematically small, at 4-5{sigma} level, compared with the prediction of a best smooth-lens model (1.09) represented by a singular isothermal ellipsoid and external shear. The smooth-lens model, which also considers the additional lensing effect of the possible faint satellite, object X, still provides a large flux ratio of A2/A1=1.06, thereby suggesting the presence of more substructures that can explain our observational result. In contrast, for Q2237+030, our high signal-to-noise observation indicates that the mid-infrared flux ratios between all the four images of Q2237+030 are virtually consistent with the prediction of a smooth-lens model. Based on the size estimate of the dust torus surrounding the nuclei of these QSOs, we set limits on the mass of a substructure in these lens systems, which can cause anomalies in the flux ratios. For MG0414+0534, since the required mass of a substructure inside its Einstein radius is {approx}>360 M {sub sun}, millilensing by a cold dark matter substructure is most likely. If it is modeled as a singular isothermal sphere, the mass inside a radius of 100 pc is given as {approx}>1.0 x 10{sup 5} M {sub sun}. For Q2237+030, there is no significant evidence of millilensing, so the reported anomalous flux ratios in shorter wavelengths are entirely caused due to microlensing by stars.

79 ASTRONOMY AND ASTROPHYSICS↗

A Novel Deployable Telescope Baffle Using the Kresling Origami Fold

This report introduces a novel deployable origami baffle designed for telescopes and optical systems, which reduces stray light while maintaining high compactness ratios and low weight. This design leverages the planar nature of the end caps on a cylindrical Kresling origami fold to incorporate mounting points, deployable options, and baffle vanes. The adaptable nature of origami (number of faces, origami geometrical ratios, scaling, etc.) allows the design to easily conform to system requirements, including field of view, deployed length, stowed/deployed stability points, and available volume. Geometric ratios that exhibit bistability in both the stowed and deployed states are discussed in detail, as this results in a rigid structure that maintains its desired configuration. Several designs were conceptualized, and multiple small-scale prototypes were constructed. Potential applications include camera lens hoods, lightweight astronomy telescopes, and deployable baffles for space telescopes and optical systems.

42 ENGINEERING↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

Rapid Reflective Facet Characterization Using Fringe Reflection Techniques

Reflective mirror facets for concentrating solar power (CSP) systems have stringent requirements on the surface slope accuracy in order to provide adequate system performance. This paper presents a tool that can fully characterize facets quickly enough for 100% inspection on a production line. A facet for a CSP system, specifically a dish concentrator has a parabolic design shape. This shape will concentrate near-parallel rays from the sun to a point (or a line for trough systems). Deviations of surface slope from the design shape impact the performance of the system, either losing power that misses the target or increasing peak fluxes to undesirable levels. During development or production, accurate knowledge of facet defects can lead to improvements to lower cost or improve performance. The reported characterization system, SOFAST (Sandia Optical Fringe Analysis Slope Tool), has a computer-connected camera that images the reflective surface, which is positioned so that it reflects an active target, such as an LCD screen, to the camera. A series of fringe patterns are displayed on the screen while images are captured. Using the captured information, the reflected target location of each pixel of mirror viewed can be determined, and thus through a mathematical transformation, a surface normal map can be developed. This is then fitted to the selected model equation, and the errors from design are characterized. While similar approaches have been explored, several key developments are presented here. The combination of the display, capture, and data reduction in one system allows rapid characterization. An “electronic boresight” approach is utilized to accommodate physical equipment positioning deviations, making the system insensitive to setup errors. Up to 1.5×10 6 points are characterized on each facet. Finally, while prior automotive industry commercial systems resolve the data to shape determination, SOFAST concentrates on slope characterization and reporting, which is tailored to solar applications. SOFAST can be used for facet analysis during development. However, the real payoff is in production, where complete analysis is performed in about 10s. With optimized coding, this could be further reduced.

14 SOLAR ENERGY↗

Autonomous Sensor System for Wind Turbine Blade Collision Detection

This paper presents an automated blade collision detection system for use on wind turbines, toward the goal of supporting monitoring and quantitative assessment of wind energy impacts on wildlife. A wireless, multisensor module mounted at the blade root measures surface vibrations, and a blade-mounted camera provides image capture of colliding objects. Using sensor data recorded during field testing of the system on an operational wind turbine, we present the development, training, and testing of automated detection algorithms for collision detection using machine-learning approaches. In particular, we compare the use of a new two-step, anomaly-based classification algorithm with conventional adaptive boosting and amplitude-based detection techniques, where the two-step approach improves average precision for the experimental data set. This integrated sensor and classification systems demonstrates a new approach for automated, on-blade collision detection for wind turbines, with broad utility across structural health monitoring applications.

17 WIND ENERGY↗

Absolute calibration of an electron spectrometer using high energy electrons produced by the laser-plasma interaction

An in situ observation system has been developed to observe the absolute electron energy spectra of electron beams generated by laser-plasma interaction. A phosphor screen (DRZ) coupled with a charge coupled device camera is used to detect the electrons. A new method is proposed to calibrate the absolute sensitivity of the detection system for a wide energy range with a single shot by using an electron beam generated by laser-plasma interaction. The sensitivity of the system is found to be high, which is comparable to that of an imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

R and DE Robotic Sensor Intern Team: Advanced Sensor Suite Prototype

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel is an example of such an environment where a biannual inspection is currently performed. Presently inspections are performed by teleoperated robotic crawlers which provide low-res video feedback to the structural engineers. Advanced sensors: including Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. Possible sensors were a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The Hokuyo UTM-30LX-EW shown below provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. Along with the Lidar, a camera sensor, IMU sensor, pan-tit unit, and on board computer needed to be identified. The two panospheric cameras allow for full 360 deg. FOV. The IMU will give data on the state of the robot inside the tunnel. The computer is used to gather and process data on board and to control the pan-tilt system. Mounts were designed and 3D printed to build the prototype of the sensor suite. It was designed to have the Lidar on top With its full FOV free while having the camera below and as close to together as possible while still leaving much of their FOV visible. The design also managed the cables such that they were unlikely to be damaged if in tension and so that they did not intrude much on the cameras vision. The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. a postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans With one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 2) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved. The sensor trees depth accuracy was evaluated in comparison to a high end commercial FARO Terrestrial Laser Scanner (TLS) with specifications for millimeter accuracy at distances above 10 m. For the purposes of these tests, the depth measurements produced by the TLS were taken as ground truth. Example test wall panels were scanned with the TLS and postprocessed with its proprietary software, and subsequently scanned with the sensor tree system. The two scans were manually aligned and for each point in the output cloud from the sensor tree, the distance to the nearest ground truth point in the FARO cloud was determined. 98.7% of all produced points were within the specified target range of 6 mm, with an average deviation of 1.75 mm. The test walls used have an overall in-wall depth variation of around 40 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Investigation and Pre‐Processing Opportunities for Textile‐To‐Textile Recycling

Millions of metric tons of textiles are landfilled or incinerated each year in the United States, with less than 1% of textiles recycled into new clothing or fabrics. To counter this trend, a growing number of companies and researchers are exploring how a circular economy can be applied to support textile‐to‐textile recycling. A significant barrier they face comes down to quickly and efficiently extracting pure feedstock material from post‐consumer garments that feature a mix of natural and synthetic fibers. Textile recyclers prefer pure feedstocks, as working with mixed sources typically means lower throughput, higher risk of equipment failure, and diminished business margins. To facilitate a circular economy for textiles, methods, and technologies are needed that can efficiently separate out materials and contaminants from end‐of‐life textiles to increase the flow of pure feedstocks to recyclers. This paper summarizes findings from interviews with a cross section of textile recyclers and from a review of literature to define basic feedstock requirements. In addition to our qualitative research, we deconstruct a bale of post‐consumer textiles and analyze them using computer‐vision imaging, Fourier transform infrared spectroscopy (FTIR), and machine learning. The resulting data are used to set system‐level design inputs for an automated contaminant removal system to process post‐consumer clothing into appropriate feedstocks for recycling. To set the system's levels for automated real‐time near‐infrared analysis, we identify the minimum percentage of primary material that any single garment in a load of used clothing must contain for the average of the full output stream to meet the target purity levels of recyclers. Here, the envisioned automated system can also address undesirable trace materials that might contaminate the processed stream by using imaging cameras coupled with artificial intelligence to identify sections of clothing for de‐trimming. Proof‐of‐concept machine learning algorithms are evaluated to locate and identify trims or garment areas with hidden contaminant materials. Integrating these methods into automated textile cutting systems can provide a cost‐effective means for increasing feedstock purity from used clothing, which can advance circularity for textiles by helping recyclers to reach production volumes and quality targets that were not possible solely with manual dismantling operations.

Parsons, Ryan [Rochester Institute of Technology, ↗

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗