Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Comparative life cycle assessment of a modular cross-laminated timber residential building designed for disassembly and reuse versus traditional wood frame construction

There is a need for affordable housing across the U.S., with high-performance modular and prefabricated buildings providing a logical avenue for meeting some of this demand. However, there is a need to balance high performance construction – including low emissions – with affordability. To provide a proof-of-concept in meeting these goals, the Circular Home is a cross-laminated timber (CLT)-based deconstructible and reconfigurable single-family residence that meets high performance targets in moisture, energy, design, economics, and life cycle assessment (LCA). This study focuses on the LCA, presenting a cradle-to-cradle whole-building life cycle assessment (WBLCA) for the Circular Home and a functionally equivalent Baseline Home constructed with traditional materials and methods. The functional unit is 1 m 2 of gross floor area across 60 years. Revit building information models (BIM) provided material quantities and Tally LCA was utilized for impact data (inclusive of biogenic carbon sequestration), supplemented with manufacturer environmental product declarations (EPDs). The Circular Home outperforms the baseline residence in most measured impact categories, including global warming potential (GWP), producing −2.73 kgCO 2 eq/m 2 in embodied emissions, whereas the modeled baseline has an embodied GWP of 428 kgCO 2 eq/m 2 . The careful material selection and advanced building design optimizes performance, with the Circular Home containing only −0.006 times the embodied emissions and −0.02 times the operational emissions of its traditional counterpart. Finally, the unique contribution of this work is in the environmental impact comparison of a high-performance modular CLT structure that can be affordably scaled and mass produced in a U.S. market, compared to typical single family home construction.

Circularity↗

Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Site selection feasibility for a solar energy system on the Fairbanks Federal Building

A feasibility study was performed for the installation of a solar energy system on the Federal Building in Fairbanks, Alaska, a multifloor office building with an enclosed parking garge. The study consisted of determining the collectable solar energy at the Fairbanks site on a monthly basis and comparing this to the monthly building heating load. Potential conventional fuel savings were calculated on a monthly basis and the overall economics of the solar system applications were considered. Possible solar system design considerations, collector and other system installation details, interface of the solar system with the conventional HVAC systems, and possible control modes were all addressed. Conclusions, recommendations and study details are presented.

Source record↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Bio-Based Phase Change Materials as an Energy Storage Medium in Building Envelopes

A promising approach to increasing the energy efficiency of buildings is the implementation of phase change material (PCM) in building envelope systems. Several studies have reported the energy saving potential of PCM in building envelopes. However, wide application of PCMs in building applications has been inhibited, in part, by their high cost. This article describes a novel paraffin product made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application, with the ultimate goal of commercializing a low-cost PCM platform. The low-cost PCM pellets were mixed with cellulose insulation, installed in external walls and field-tested under natural weatherization conditions for a period of several months. In addition, several PCM samples and PCM-cellulose samples were prepared under controlled conditions for laboratory-scale testing. The laboratory tests were performed to determine the phase change properties of PCM-enhanced cellulose insulation both at microscopic and macroscopic levels. This article presents the data and analysis from the exterior test wall and the laboratory-scale test data. PCM behavior is influenced by the weather and interior conditions, PCM phase change temperature and PCM distribution within the wall cavity, among other factors. Under optimal conditions, the field data showed up to 20% reduction in weekly heat transfer through an external wall due to the PCM compared to cellulose-only insulation.

low-cost PCM↗

SULI Final Report

This project looks at alternative water sources, specifically in the field of desalination and selective ion removal through capacitive deionization (CDI). It project aims to both scale up the desalination capabilities of CDI cells as well as determine the selectivity of CDI for particular ions. My task is to design and build cells that have reproducible performance and characterize the materials for building these cells. The scientific methods I’ve learned through my work in CDI and the data mining and analysis tools I’ve become familiar with through CAES will be important catalysts in my future success in a graduate program. The purpose of this presentation is to give a standard of practice for my current method of building of capacitive deionization cells. Parts 1 and 2 will be discussed in which the electrodes are prepared, and the cell is built.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental study of high contraction ratio, subsonic wind tunnel inlets

The inlet or contraction section has significant impact on the performance and operating characteristics of any subsonic wind tunnel. Previous experimental studies have been conducted to examine specific aspects of inlet performance and design. This work builds on this earlier experience by performing a comprehensive experimental analysis of a member of a family of high contraction ratio inlets used on indraft type wind tunnels. Quantitative flow field measurements were made using wall static ports, a five-hole pressure probe, and a hot wire anemometry system. Smoke flow visualization techniques were used to examine the inlet flow in a more qualitative manner and to correlate with quantitative measurements. This experimental investigation has provided insight into some of the many problems associated with inlet flows.

Caylor, M. J.↗

Peak-Seeking Optimization of Trim for Reduced Fuel Consumption: Architecture and Performance Predictions

A peak-seeking control approach for real-time trim configuration optimization for reduced fuel consumption has been developed by researchers at the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center to address the goals of the NASA Environmentally Responsible Aviation project to reduce fuel burn and emissions. The peak-seeking control approach is based on a steepest-descent algorithm using a time-varying Kalman filter to estimate the gradient of a performance function of fuel flow versus control surface positions. In real-time operation, deflections of symmetric ailerons, trailing-edge flaps, and leading-edge flaps of an F/A-18 airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) are controlled for optimization of fuel flow. This paper presents the design and integration of this peak-seeking controller on a modified NASA F/A-18 airplane with research flight control computers. A research flight was performed to collect data to build a realistic model of the performance function and characterize measurement noise. This model was then implemented into a nonlinear six-degree-of-freedom F/A-18 simulation along with the peak-seeking control algorithm. With the goal of eventual flight tests, the algorithm was first evaluated in the improved simulation environment. Results from the simulation predict good convergence on minimum fuel flow with a 2.5-percent reduction in fuel flow relative to the baseline trim of the aircraft.

performance optimization↗

Peak-Seeking Optimization of Trim for Reduced Fuel Consumption: Architecture and Performance Predictions

A peak-seeking control approach for real-time trim configuration optimization for reduced fuel consumption has been developed by researchers at the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center to address the goals of the NASA Environmentally Responsible Aviation project to reduce fuel burn and emissions. The peak-seeking control approach is based on a steepest-descent algorithm using a time-varying Kalman filter to estimate the gradient of a performance function of fuel flow versus control surface positions. In real-time operation, deflections of symmetric ailerons, trailing-edge flaps, and leading-edge flaps of an FA-18 airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) are controlled for optimization of fuel flow. This presentation presents the design and integration of this peak-seeking controller on a modified NASA FA-18 airplane with research flight control computers. A research flight was performed to collect data to build a realistic model of the performance function and characterize measurement noise. This model was then implemented into a nonlinear six-degree-of-freedom FA-18 simulation along with the peak-seeking control algorithm. With the goal of eventual flight tests, the algorithm was first evaluated in the improved simulation environment. Results from the simulation predict good convergence on minimum fuel flow with a 2.5-percent reduction in fuel flow relative to the baseline trim of the aircraft.

peak-seeking↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗

Mini-apps for high performance data analysis

Scaling-up scientific data analysis and machine learning algorithms for data-driven discovery is a grand challenge that we face today. Despite the growing need for analysis from science domains that are generating `Big Data' from instruments and simulations, building high-performance analytical workflows of data-intensive algorithms have been daunting because: (i) the `Big Data' hardware and software architecture landscape is constantly evolving, (ii) newer architectures impose new programming models, and (iii) data-parallel kernels of analysis algorithms and their performance facets on different architectures are poorly understood. To address these problems, we have: (i) identified scalable data-parallel kernels of popular data analysis algorithms, (ii) implemented `Mini-Apps' of those kernels using different programming models (e.g. Map Reduce, MPI, etc.), (iii) benchmarked and validated the performance of the kernels in diverse architectures. In this paper, we discuss two of those Mini-Apps and show the execution of principal component analysis built as a workflow of the Mini-Apps. We show that Mini-Apps enable scientists to (i) write domain-specific data analysis code that scales on most HPC hardware and (ii) and offers the ability (most times with over a 10x speed-up) to analyze data sizes 100 times the size of what off-the-shelf desktop/workstations of today can handle.

Sukumar, Sreenivas R.↗

GHG policy impacts for Seattle’s buildings: targets, timing, and scope

Many US cities are addressing climate change by setting goals to reduce their greenhouse gas (GHG) emissions by a specified amount within a specified time period. In order to achieve these goals, reducing emissions from existing buildings is crucial. Many cities are passing legislation to target existing buildings through benchmarking, auditing, retuning, or energy or emissions performance standards. As cities design legislation, they must consider the timing of the policies, how to prioritize building types and sizes, and how these design decisions will impact the city’s emissions. This paper addresses these questions for one particular US city: Seattle, Washington. A model of Seattle’s building stock was created with benchmarking and tax assessor data. It was then used to predict GHG emissions reductions due to different policy implementations for existing commercial and multifamily buildings. Key findings are: (1) the proposed emissions policy is expected to reduce cumulative emissions from buildings by 19% between 2020 and 2050; (2) delaying the implementation of the policy by five years could limit savings to 12%; and (3) including smaller buildings in the policy could increase savings to 34%. The lessons learned and how this can be used by other cities are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development Unit for In-Space Pneumatic Helium Transfer Compressor

High-pressure gaseous helium (GHe) plays a critical role in spacecraft propulsion due to its near exclusive use for pressurization of propellant tanks. Several different designs for helium compressor technologies have been developed for use on Earth; however, significant design changes are required to meet the power, thermal/heat dissipation, vacuum, vibration/shock, size, mass, and efficiency requirements needed for space and launch environments. Currently, no capability exists for mass efficient on-orbit GHe (or xenon) transfer, nor has it ever been attempted. This effort proposed several challenging requirements for the vendor to develop a one-of-a-kind pneumatic compressor prototype. In order to develop a compressor prototype at a TRL 4, a partnership with Air Squared, Inc. was established. This CIF project concluded with the receipt of a prototype along with a proposed design for a flight unit; however, it will not be built due to funding limitations. The vendor had moderate success with initial testing of the prototype at lower pressures (with shimming configured for low pressure). There were delays with testing since the unit was built for higher pressures and the low pressure shimming was challenging to implement. It was found that operation of the compressor at lower pressures caused increased friction on the motor shaft which resulted in the unit drawing more power (current). This was initially thought to be a motor or controller defect. Subsequent high pressure testing at KSC showed that the friction was reduced for the optimal design point (with a high pressure shimming configuration) and the motor (and controller) performed nominally. Following the vendor testing, the unit was tuned/shimmed for a nominal inlet pressure and shipped to KSC for high pressure testing using the custom-designed setup in the Vehicle Assembly Building. The unit performed well, showing the capability to achieve over higher pressure of compression. The pressure differential could likely increase, however, the maximum output of the power supply used for testing was reached, limiting the compressor motor’s capability. Following the GN2 testing, the test setup was converted to GHe with at high pressure. It was shown that although the unit was unable to achieve similar high pressure differentials due to reverse leakage of the GHe through the scroll tip seals, it did achieve the desired GHe compression. This may still be useful for some applications, however, for the purpose of on-orbit GHe transfer, the single stage design would need to be changed to include multiple stages to achieve the compression goals initially proposed by the project.

Brian Nufer↗

Development of high‐performance partially biobased thermoset polyester using renewable building blocks from isosorbide, 1,3‐propanediol, and fumaric acid

Abstract Research on biobased thermoset resins has been overlooked when compared with the rapid progress on biobased thermoplastics. The objective of this work was to develop unsaturated polyester prepolymers based on building blocks derived from renewable raw materials, namely, biobased isosorbide, 1,3‐propanediol, and fumaric acid, with petroleum‐derived phthalic anhydride. The prepolymers developed herein behaved as low‐molecular weight macromolecules (oligoesters), with M n varying between 1.2 and 1.5 kDa, but achieved a high bio‐content of up to 87.1 wt%. The prepolymers were incorporated into reactive diluents comprising a blend of 2‐hydroxyethyl methacrylate and styrene, formulated to be eco‐friendlier and less toxic than typical styrene‐only incorporation approach, thus resulting in resins with viscosities between 750 and 950 cP. These resins are suitable for use in various fiber‐reinforced polymer production techniques, such as manual lamination, vacuum infusion, and pultrusion, having the benefit of presenting over 50 wt% of bio‐content in some formulations. Moreover, the crosslinked polyester resins (thermosets) exhibit comparable mechanical and thermomechanical behavior to their petrochemical‐based counterparts, with modulus of elasticity and tensile strength of up to 3.9 GPa and 62.1 MPa, respectively, and glass transition temperatures of up to 106°C, making them greener alternatives for high‐performance structural applications.

Hofmann, Mateus↗

Achieving Actionable Results from Available Inputs: Metamodels Take Building Energy Simulations One Step Further

Modeling commercial building energy usage can be a difficult and time-consuming task. The increasing prevalence of optimization algorithms provides one path for reducing the time and difficulty. Many use cases remain, however, where information regarding whole-building energy usage is valuable, but the time and expertise required to run and post-process a large number of building energy simulations is intractable. A relatively underutilized option to accurately estimate building energy consumption in real time is to pre-compute large datasets of potential building energy models, and use the set of results to quickly and efficiently provide highly accurate data. This process is called metamodeling. In this paper, two case studies are presented demonstrating the successful applications of metamodeling using the open-source OpenStudio Analysis Framework. The first case study involves the U.S. Department of Energy's Asset Score Tool, specifically the Preview Asset Score Tool, which is designed to give nontechnical users a near-instantaneous estimated range of expected results based on building system-level inputs. The second case study involves estimating the potential demand response capabilities of retail buildings in Colorado. The metamodel developed in this second application not only allows for estimation of a single building's expected performance, but also can be combined with public data to estimate the aggregate DR potential across various geographic (county and state) scales. In both case studies, the unique advantages of pre-computation allow building energy models to take the place of topdown actuarial evaluations. This paper ends by exploring the benefits of using metamodels and then examines the cost-effectiveness of this approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings (Interim Final Report)

Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $\$$4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single-family homes. HESP provided cash incentives and financing opportunities to owners of one-to four-unit structures, which resulted in thousands of energy assessments and whole-house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium-sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trust’s MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR® Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building— all at no cost to the building owner. The ERP is developed by a program partner using either the Trust’s approved modeling or prescriptive tools; it provides detailed information about the current energy related conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self-sustaining, market-driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily units—such as Portland, Lewiston- Auburn, Bangor, and Augusta—MEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trust’s successful HESP for single-family residences. MEP offers significant incentives for building owners to participate in the upgrade program. Wholebuilding benchmarking services are available to most multifamily housing buildings free of charge. The service provides the building owner with an assessment of the building's current energy efficiency as compared to other multifamily buildings on a national scale, establishes a baseline to measure future improvements, and enables owners to track monthly energy consumption using the ENERGY STAR Portfolio Manager. Once the benchmarking process is complete, the program links building owners with approved program partners (e.g., energy professionals, home performance contractors) to identify and implement specific energy-saving opportunities in the building. Program partners can also provide project quotes with estimated financing incentives and payback period calculations that enable building owners to make informed decisions. What's more, the Trust provides two financial incentives for successful completion of program milestones. The first is a per-unit incentive for completion of an approved ERP (i.e., $\$$100 per unit if a prescriptive path is followed, and $\$$200 per unit for a modeled ERP). Upon final inspection of the installed project scope of work, an incentive of $\$$1,400 per unit or 50% of installed cost—whichever is less—is paid. The Trust originally established a $\$$1 million loan-loss reserve fund (LLRF) to further enhance financing opportunities for qualified multifamily building owners. This funding mechanism was designed to connect building owners with lenders that retain the mortgages for their properties and encourages the lenders to offer financing for energy efficiency improvements. However, there has been no interest in the LLRF and therefore the LLRF has been reduced. Ultimately, MEP plans to build an online tool for building owners to assess opportunities to make upgrades in their multifamily units. The tool will include a performance rating system to provide a way for building owners to more easily understand energy use in their building, and how it could be improved with energy efficiency upgrades. Prospective tenants will also be able to use the rating system to make informed decisions about where to rent. Furthermore, the rating can be incorporated into real estate listings as a way for prospective home buyers and the real estate financial community to evaluate a home's operating costs. The Trust’s MEP has identified the state's most experienced energy professionals, vendors, suppliers, and contractors that install energy efficiency equipment in the multifamily sector to be qualified program partners. To be eligible for partnership, energy assessment professionals and contractors are required to have demonstrated experience in the multifamily sector and hold associated professional certifications, such as Building Operator Certification (BOC), Certified Energy Manager (CEM), Professional Engineer (PE), or Building Performance Institute (BPI) Multifamily Building Analyst. Widespread program interest has enabled the Trust to redirect funds that might otherwise be needed for program promotion to building capacity through contractor training. In addition to boosting professional training and certification opportunities, MEP teaches its partners how to market the multifamily program to prospective multifamily homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-D-204-06: Integration of Machine Learning and Bioinformatics Methods to Analyze Genome-Wide Association Study Data for Rectal Bleeding and Erectile Dysfunction Following Radiotherapy in Prostate Cancer

Purpose: We investigated whether integration of machine learning and bioinformatics techniques on genome-wide association study (GWAS) data can improve the performance of predictive models in predicting the risk of developing radiation-induced late rectal bleeding and erectile dysfunction in prostate cancer patients. Methods: We analyzed a GWAS dataset generated from 385 prostate cancer patients treated with radiotherapy. Using genotype information from these patients, we designed a machine learning-based predictive model of late radiation-induced toxicities: rectal bleeding and erectile dysfunction. The model building process was performed using 2/3 of samples (training) and the predictive model was tested with 1/3 of samples (validation). To identify important single nucleotide polymorphisms (SNPs), we computed the SNP importance score, resulting from our random forest regression model. We performed gene ontology (GO) enrichment analysis for nearby genes of the important SNPs. Results: After univariate analysis on the training dataset, we filtered out many SNPs with p>0.001, resulting in 749 and 367 SNPs that were used in the model building process for rectal bleeding and erectile dysfunction, respectively. On the validation dataset, our random forest regression model achieved the area under the curve (AUC)=0.70 and 0.62 for rectal bleeding and erectile dysfunction, respectively. We performed GO enrichment analysis for the top 25%, 50%, 75%, and 100% SNPs out of the select SNPs in the univariate analysis. When we used the top 50% SNPs, more plausible biological processes were obtained for both toxicities. An additional test with the top 50% SNPs improved predictive power with AUC=0.71 and 0.65 for rectal bleeding and erectile dysfunction. A better performance was achieved with AUC=0.67 when age and androgen deprivation therapy were added to the model for erectile dysfunction. Conclusion: Our approach that combines machine learning and bioinformatics techniques enabled designing better models and identifying more plausible biological processes associated with the outcomes.

60 APPLIED LIFE SCIENCES↗

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗