Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Potential Operating Orbits for Fission Electric Propulsion Systems Driven by the SAFE-400

Safety must be ensured during all phases of space fission system design, development, fabrication, launch, operation, and shutdown. One potential space fission system application is fission electric propulsion (FEP), in which fission energy is converted into electricity and used to power high efficiency (Isp greater than 3000s) electric thrusters. For these types of systems it is important to determine which operational scenarios ensure safety while allowing maximum mission performance and flexibility. Space fission systems are essentially nonradioactive at launch, prior to extended operation at high power. Once high power operation begins, system radiological inventory steadily increases as fission products build up. For a given fission product isotope, the maximum radiological inventory is typically achieved once the system has operated for a length of time equivalent to several half-lives. After that time, the isotope decays at the same rate it is produced, and no further inventory builds in. For an FEP mission beginning in Earth orbit, altitude and orbital lifetime increase as the propulsion system operates. Two simultaneous effects of fission propulsion system operation are thus (1) increasing fission product inventory and (2) increasing orbital lifetime. Phrased differently, as fission products build up, more time is required for the fission products to naturally convert back into non-radioactive isotopes. Simultaneously, as fission products build up, orbital lifetime increases, providing more time for the fission products to naturally convert back into non-radioactive isotopes. Operational constraints required to ensure safety can thus be quantified.

Houts, Mike↗

Potential Operating Orbits for the SAFE-400

Safety must be ensured during all phases of space fission system design, development, fabrication, launch, operation, and shutdown. One potential space fission system application is fission electric propulsion (FEP), in which fission energy is converted into electricity and used to power high efficiency (Isp is greater than 3000s) electric thrusters. For these types of systems it is important to determine which operational scenarios ensure safety while allowing maximum mission performance and flexibility. Space fission systems are essentially non-radioactive at launch, prior to extended operation at high power. Once high power operation begins, system radiological inventory steadily increases as fission products build up. For a given fission product isotope, the maximum radiological inventory is typically achieved once the system has operated for a length of time equivalent to several half-lives. After that time, the isotope decays at the same rate it is produced, and no further inventory builds in. For an FEP mission beginning in Earth orbit, altitude and orbital lifetime increase as the propulsion system operates. Two simultaneous effects of fission propulsion system operation are thus (1) increasing fission product inventory and (2) increasing orbital lifetime. Phrased differently, as fission products build up, more time is required for the fission products to naturally convert back into non-radioactive isotopes. Simultaneously, as fission products build up, orbital lifetime increases, providing more time for the fission products to naturally convert back into non-radioactive isotopes. Operational constraints required to ensure safety can thus be quantified.

Houts, Mike↗

Operations to Research: Communication of Lessons Learned

This presentation explores ways to build upon previous spaceflight experience and communicate this knowledge to prepare for future exploration. An operational approach is highlighted, focusing on selection and retention standards (disease screening and obtaining medical histories); pre-, in-, and post-flight monitoring (establishing degrees of bone loss, skeletal muscle loss, cardiovascular deconditioning, medical conditions, etc.); prevention, mitigation, or treatment (in-flight countermeasures); and, reconditioning, recovery, and reassignment (post-flight training regimen, return to pre-flight baseline and flight assignment). Experiences and lessons learned from the Apollo, Skylab, Shuttle, Shuttle-Mir, International Space Station, and Orion missions are outlined.

Fogarty, Jennifer↗

Investigating Solar Radiation Pressure Modeling for Operations in Near Rectilinear Halo Orbit

NASA’s Gateway program will build a crew-tended station in an Earth-Moon Near Rectilinear Halo Orbit (NRHO). Deep space operations differ considerably from Low Earth Orbit (LEO) operations in the environmental modeling, orbit geometry, and propagation timespans in operations. The cislunar environment, as opposed to the LEO environment, lacks atmospheric drag and is simultaneously affected by the gravity of both the Earth and the Moon, and solar radiation pressure (SRP) has a significant effect. This paper investigates the impacts of various SRP models on prediction accuracy, attitude control accuracy, orbit determination performance, and computational burden.

Guidance↗

Evaluating the Use of High-Fidelity Simulator Research Methods to Study Airline Flight Crew Resilience

As it evolves, aviation will continue to require integration of a wide range of safety systems and practices, some of which are already in place and others that are yet to be developed. New concepts in system safety thinking have emerged to consider not only what may go wrong, but also what can be learned when things go right during commercial flight operations. Taken together, these complementary perspectives form a more comprehensive approach to systemsafety thinking that can help to recognize and preserve the resilient performance capabilities currently provided by humans. A need exists, however, for research methods to enable better understanding of the human contributions to aviation safety. NASA’s System-Wide Safety Project supports research on using flight simulation methods to study operator resilience and safety-producing behaviors. Building on prior NASA efforts investigating procedural non-adherences during area navigation standard terminal route arrivals, a high-fidelity commercial aviation line operational simulation (LOS) experiment has been designed to study how flight crews anticipate, monitor for, respond to, and learn from expected and unexpected disturbances during these operations. A diverse set of LOS scenarios were developed to simulate highly realistic, complex, but routinely encountered operational situations. Each scenario provided multiple opportunities to collect data on how flight crews manage threats and errors, as well as novel opportunities to observe resilient and safety-producing behaviors. The experimental design, implications for the study of safety-producing behaviors using simulation, and considerations for airline pilot training will be discussed.

Chad L Stephens↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Hypercane

Automatically summarizing a collection of documents requires analyzing their features using various operations. Hypercane is a framework for building algorithms for sampling files from a collection. Sampling is a vital part of automatic summarization. Hypercane ties together many existing third-party libraries. These libraries include those for processing web resources, natural language processing for analyzing text and filtering documents, and machine learning for clustering summarization candidates. A user can run up to more than 70 operations on a corpus in the order of their choosing. Through these operations, they can create custom automatic summarization algorithms to help them process the corpus of their choice. Details of the algorithms possible with Hypercane are available in Jones 2021. Details of running Hypercane are available in Jones et al.; 2021.

Jones, Shawn↗

Data communication network at the ASRM facility

The main objective of the report is to present the overall communication network structure for the Advanced Solid Rocket Motor (ASRM) facility being built at Yellow Creek near Iuka, Mississippi. This report is compiled using information received from NASA/MSFC, LMSC, AAD, and RUST Inc. As per the information gathered, the overall network structure will have one logical FDDI ring acting as a backbone for the whole complex. The buildings will be grouped into two categories viz. manufacturing critical and manufacturing non-critical. The manufacturing critical buildings will be connected via FDDI to the Operational Information System (OIS) in the main computing center in B 1000. The manufacturing non-critical buildings will be connected by 10BASE-FL to the Business Information System (BIS) in the main computing center. The workcells will be connected to the Area Supervisory Computers (ASCs) through the nearest manufacturing critical hub and one of the OIS hubs. The network structure described in this report will be the basis for simulations to be carried out next year. The Comdisco's Block Oriented Network Simulator (BONeS) will be used for the network simulation. The main aim of the simulations will be to evaluate the loading of the OIS, the BIS, the ASCs, and the network links by the traffic generated by the workstations and workcells throughout the site.

Moorhead, Robert J., II↗

Data communication network at the ASRM facility

This report describes the simulation of the overall communication network structure for the Advanced Solid Rocket Motor (ASRM) facility being built at Yellow Creek near Iuka, Mississippi as of today. The report is compiled using information received from NASA/MSFC, LMSC, AAD, and RUST Inc. As per the information gathered, the overall network structure will have one logical FDDI ring acting as a backbone for the whole complex. The buildings will be grouped into two categories viz. manufacturing intensive and manufacturing non-intensive. The manufacturing intensive buildings will be connected via FDDI to the Operational Information System (OIS) in the main computing center in B_1000. The manufacturing non-intensive buildings will be connected by 10BASE-FL to the OIS through the Business Information System (BIS) hub in the main computing center. All the devices inside B_1000 will communicate with the BIS. The workcells will be connected to the Area Supervisory Computers (ASCs) through the nearest manufacturing intensive hub and one of the OIS hubs. Comdisco's Block Oriented Network Simulator (BONeS) has been used to simulate the performance of the network. BONeS models a network topology, traffic, data structures, and protocol functions using a graphical interface. The main aim of the simulations was to evaluate the loading of the OIS, the BIS, and the ASCs, and the network links by the traffic generated by the workstations and workcells throughout the site.

Moorhead, Robert J., II↗

First SELAP Algorithm Operational Experience of the New LLRF 3.0 RF Control System

The JLAB LLRF 3.0 system has been developed and is replacing the 30-year-old LLRF systems in the CEBAF accelerator. The LLRF system builds upon 25 years of design and operational RF control experience (digital and analog), and our recent collaboration in the design of the LCLSII LLRF system. The new system also incorporates a cavity control algorithm using a fully functional phase and amplitude locked Self Exciting Loop (SELAP). The first system (controlling 8 cavities) was installed and commissioned in August of 2021. Since then the new LLRF system has been operating with cavity gradients up to 20 MV/m, and electron beam currents up to 350 uA. This paper discusses the operational experience of the LLRF 3.0 SELAP algorithm along with other software and firmware tools like cavity and klystron characterization and quench detection.

Plawski, T. E.↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

Best Practices Guide: Benchmarking Energy Efficiency in Laboratories

Purpose and Audience A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency and greenhouse gas reductions in their facilities. For example, new federal buildings and major renovations of existing buildings are to reduce fossil fuel-generated energy consumption by 90% in 2025, and 100% in 2030, compared with a 2003 baseline (FEMP n.d.). Minnesota SB2030 standard requires achieving an 80% reduction from the average building baseline for commercial, institutional, and industrial buildings (SB2030 n.d). A laboratory—new or existing—is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified and tracked over the life cycle of the building, from design through construction, commissioning, operations, and renovations. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify relative to other priorities. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole-building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into new construction or retrofit of existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to I2SL resources, including technology best practice guides and case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Do parcel lockers reduce delivery times? Evidence from the field

Common-carrier parcel lockers have emerged as a secure, automated, self-service means of delivery consolidation in congested urban areas, which are believed to mitigate last-mile delivery challenges through reducing out-of-vehicle delivery times and consequently vehicle dwell times at the curb. However, little research exists to empirically demonstrate the environmental and efficiency gains from this technology. In this study, we designed a nonequivalent groups pre-test/post-test control experiment to estimate the causal effects of a parcel locker on delivery times in a residential building in downtown Seattle, WA. Here, the causal effects are measured in terms of vehicle dwell time and the time delivery couriers spend inside the building, through the difference-in-difference method and using a similar nearby residential building as a control. The results showed a statistically significant decrease in time spent inside the building, and small yet insignificant reduction in delivery vehicle dwell time at the curb. The locker was also well received by the building managers and residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Voltage Switching AC-DC Converter Based on Zero State Modulation (ZSM)

In this paper, a half-bridge building block that can achieve soft switching across the complete operating range while operating under fixed frequency is proposed. In addition, dead-beat model predictive controls to control the same are also proposed. The proposed converter, referred to as zero-state modulated (ZSM) converter, uses a zero state, enabled by a small auxiliary switch, to achieve soft-switching. The approach allows lower switching loss, controlled dv/dt, small filter inductor, fixed frequency operation allowing interleaving to reduce filter capacitor. A single half-bridge building block can used to realize a ZVS DC-DC converter or multiple of these building blocks can be used to achieve soft switching 1-phase or 3-phase AC-DC converters.

Kandula, Prasad↗

Conjunction Assessment and Deconfliction Paradigm for Co-located Satellite Constellations with On-Spacecraft “Autonomous” Flight Dynamics Control

Constellations that employ highly-automated satellite flight dynamics can operate safely from a collision avoidance (CA) perspective using current CA screening technology and communication paradigms—except when in proximity to other highly-automated constellations: there is no existing arrangement and concept of operations to allow the low-latency CA screenings, exchange of information, and assignment/acceptance of mitigation responsibility that co-location of highly-automated constellations requires. However, the serendipitous co-location of the NASA Starling mission—an autonomously-controlled technology demonstration constellation—and the SpaceX Starlink constellation has presented an opportunity (indeed, a requirement) to develop and build out a solution for safe operations of two (or more) co-located, highly-automated satellite constellations. Such a solution has been designed and constructed, including the required ground node; and it will be exercised as a dedicated, in-flight safety experiment between the two constellations from January to September 2024. Lessons learned from this experiment are expected to feed the design of the US Department of Commerce’s Tracking Control System for Space (TraCSS) space traffic coordination solution.

conjunction assessment↗

ACCELERATING MICROREACTOR DEVELOPMENT AND DEPLOYMENT THROUGH JOINT PUBLIC TEST BEDS AND PRIVATE ADVANCED REACTOR DEVELOPMENT

The United States Department of Energy (DOE) has funded the National Reactor Innovation Center (NRIC) to accelerate the development and commercialization of small modular reactors and other advanced reactor technologies. As part of this effort NIRC is building two strategic assets at the Idaho National Laboratory (INL) to facilitate public-private partnerships for the development and testing of advanced nuclear microreactors and Small Modular Reactors (SMR). One will provide a safe, secure, and affordable location for High-Assay Low Enriched Uranium (HALEU) fueled reactors and a second for Highly Enriched Uranium (HEU) fueled reactors. Together these testbeds fill a nuclear testing infrastructure gap. The availability of such comprehensive testing facilities at the national labs eliminates the significant financial and operational burdens associated with each developer building and licensing their own test facilities. Consequently, this approach will not only accelerate technological innovation and reduce time-to-market for advanced nuclear solutions but it also underscores the DOE's commitment to fostering an ecosystem where nuclear energy will thrive as a clean, reliable, and efficient source of power. The Demonstration of Microreactor Experiments (DOME) and Laboratory for Operations and Testing in the United States (LOTUS) have planned availability in 2026, and 2027 respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

International Radiological/Nuclear Training for Emergency Response - Major Public Events Virtual Workshop: Nuclear Security Planning and Operations (Day 3) [Slides]

This module will provide an overview of best practices for nuclear security planning requirements to include building a nuclear security plan and a concept of operations. It will introduce best practices for nuclear security planning to include the following: (1) Develop a Nuclear Security Plan, (2) Review 10 key elements of a Concept of Operations, (3) Estimate resources for an MPE, and (4) Capture lessons learned and best practices.

61 RADIATION PROTECTION AND DOSIMETRY↗