Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Sienna Modeling Framework [Slides]

NREL's Sienna modeling framework effectively builds, solves, and analyzes the scheduling problems and dynamic simulations of quasi-static infrastructure systems. It uses a modular framework to answer different questions about future energy systems, fundamentally advancing the nation's ability to model individual and integrated infrastructure systems at a range of spatial and temporal scales. This presentation will include NREL power grid researcher Clayton Barrows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Computational fluid dynamic modeling to determine the indoor environment of an electron-ion collider service building

The design for the Electron-Ion Collider (EIC) calls for several service buildings that house various power supplies and control electronics for the collider ring itself. In order to operate within specified conditions, the ambient air entering the power supplies needs to be within a certain temperature range while dissipating the heat from losses. Proper cooling is therefore a necessity in the service buildings to ensure that every aspect of the EIC works as intended. Since the EIC is in the design stage, we are evaluating the indoor environment of the service building using the current design specifications. We have researched multiple forms of literature and performed the necessary calculations to compile a list of boundary conditions that accurately represent the situation at hand. We are using computational fluid dynamics modeling to solve the conservation equations for mass, momentum, and energy (Navier-Stokes). This allows us to perform a finite element analysis which will give us the flow distribution in the room as well as temperature profiles throughout the building. We have obtained a simulation result giving us the temperature profiles for the building and it shows that the placement of the racks and supply vents are essential to obtaining an even temperature distribution. This model will provide a basis for design decisions which will affect the overall cooling of the service building without extending the schedule and avoiding a costly reworking of the cooling system.

43 PARTICLE ACCELERATORS↗

Generating synthetic occupants for use in building performance simulation

Occupant behaviour simulation frameworks can employ synthetic populations to characterize occupancy and behavioural patterns in buildings based on observed demographic data at a certain geographical location. For buildings, very few synthetic occupant populations have been generated. This paper uses a Bayesian Networks (BN) structural learning approach to synthesize populations of occupants in a multi-family housing case study. Two additional cases of office occupants and senior housing residents are considered as a cross-case comparison. Furthermore, we draw upon the extended version of drivers-needs-actions-systems (DNAS) framework to guide the selection of variables and data imputation. Our results show that the BN approach is powerful in learning the structure of data sets. The synthetic data sets successfully match the joint distributions of the underlying combined data sets. Experiments on the multi-family housing particularly show better performance than the office and senior housing cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust anomaly detection for particle physics using multi-background representation learning

Abstract Anomaly, or out-of-distribution, detection is a promising tool for aiding discoveries of new particles or processes in particle physics. In this work, we identify and address two overlooked opportunities to improve anomaly detection (AD) for high-energy physics. First, rather than train a generative model on the single most dominant background process, we build detection algorithms using representation learning from multiple background types, thus taking advantage of more information to improve estimation of what is relevant for detection. Second, we generalize decorrelation to the multi-background setting, thus directly enforcing a more complete definition of robustness for AD. We demonstrate the benefit of the proposed robust multi-background AD algorithms on a high-dimensional dataset of particle decays at the Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A machine learning approach to galaxy properties: joint redshift–stellar mass probability distributions with Random Forest

We demonstrate that highly accurate joint redshift–stellar mass probability distribution functions (PDFs) can be obtained using the Random Forest (RF) machine learning (ML) algorithm, even with few photometric bands available. As an example, we use the Dark Energy Survey (DES), combined with the COSMOS2015 catalogue for redshifts and stellar masses. We build two ML models: one containing deep photometry in the griz bands, and the second reflecting the photometric scatter present in the main DES survey, with carefully constructed representative training data in each case. We validate our joint PDFs for 10 699 test galaxies by utilizing the copula probability integral transform and the Kendall distribution function, and their univariate counterparts to validate the marginals. Benchmarked against a basic set-up of the template-fitting code bagpipes, our ML-based method outperforms template fitting on all of our predefined performance metrics. In addition to accuracy, the RF is extremely fast, able to compute joint PDFs for a million galaxies in just under 6 min with consumer computer hardware. Such speed enables PDFs to be derived in real time within analysis codes, solving potential storage issues. As part of this work we have developed galpro 1, a highly intuitive and efficient python package to rapidly generate multivariate PDFs on-the-fly. galpro is documented and available for researchers to use in their cosmology and galaxy evolution studies.

79 ASTRONOMY AND ASTROPHYSICS↗

BTO Market Success Report 2015–2020

This report highlights 28 BTO-supported, technology-oriented research and development (R&D) projects that resulted in the launch of a commercial product, focusing on identifying new technologies or commercialization updates between 2015 and 2020, where the product remained on the market as of March 2021. The report also includes a listing of the full 45 commercial products supported by BTO as well as a listing of 101 lighting components that benefited from BTO support and were commercialized and integrated into finished lighting products during the same timeframe.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaboration for Advanced Modeling of Particle Accelerators

The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.

43 PARTICLE ACCELERATORS↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Open-Source High-Fidelity Aggregate Composite Load Models of Emerging Load Behaviors for Large-Sale Analysis

The goal of this project is to accurately model the dynamic loads for power system planning and operation and to address the challenges inherent in such modeling. Existing load models are inadequate to handle the increasing proliferation of residential air conditioner loads and distributed energy resources, the emerging trends of price-responsive demand, and the growing importance of protective devices in equipment and buildings. A need has emerged to develop a fundamentally new class of load models and next-generation data tools. This work proposes to develop a set of regional–level, scalable open source load models and tools, including large-scale aggregate load protection, concept of price responsive demand, advanced load composition data, next-generation load model data tools, and advanced composite load model calibration and validation frameworks to address new challenges in the representation of next-generation load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the future of global energy-for-water

This study incorporates the energy demands of water abstraction, treatment, distribution, and post-use (wastewater) treatment into the Global Change Assessment Model (GCAM), an integrated human-Earth systems model, and analyzes a range of scenarios that estimate the future evolution of this demand of energy. The study builds on prior research on the historical demands of energy-for-water, fitting these demands of energy into existing nation-level energy balances, where demands for energy-for-water have heretofore been aggregated with other energy use in the commercial and public services, industrial, agricultural, and/or electric power sectors. This development allows for improved projections of future energy demands in general, and in this study, allows for assessment of the energy implications of different scenarios of improvements in water access and water quality that are consistent with the Sustainable Development Goals. In our baseline scenario, energy-for-water approximately doubles from 2010 to 2050, and in the scenario with the greatest level of water access, standards for treatment of wastewater, and irrigation expansion, the consequent energy-for-water demands increase three-fold from 2010 to 2050. Note also that these increases do not consider future scarcity-driven increases in energy requirements per unit of water abstraction, treatment, and distribution.

54 ENVIRONMENTAL SCIENCES↗

Impacts of the morphology of new neighborhoods on microclimate and building energy

In anticipation of emerging global urbanization and consequent increases in energy use and carbon dioxide emissions, better understanding and quantification of climate effects on energy use in cities are needed, requiring coordinated research into large-scale, regional, and microclimate impacts to and from the city structure. The methodology described here addresses this need by (1) demonstrating a process for creating and testing example morphologies for new neighborhoods for their impact on local and regional meteorology within a two-way-coupled four-domain nested mesoscale weather model (6 km horizontal resolution outer domain, 90 m horizontal innermost domain) and (2) allocating resulting building-level meteorological profiles to each building in a neighborhood for parallel computation of building-by-building energy use. Our Chicago Loop test case shows that the morphology of even a small new added development to a neighborhood affects not only its own microclimate, but also the microclimate of the original neighborhood to which the development was added, and that these changes in microclimate affect both neighborhoods’ building energy use. Furthermore, this method represents an important step toward quantifying and analyzing the relationships among climatic conditions, urban morphology, and energy use and using these relationships to inform energy-efficient urban development and planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗