Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beryllium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

On vapor shielding of dust grains of iron, molybdenum, and tungsten in fusion plasmas

The shielding effects of ablation cloud around a small dust grain composed of iron, molybdenum, or tungsten in fusion plasmas are considered. These include collisional dissipation of momentum flux of impinging plasma ions, heat transfer by secondary plasma created due to electron impact ionization of the ablated atoms, and radiative plasma power losses in the ablation cloud. The maximum radius, which limits applicability of existing dust-plasma interaction models neglecting the cloud shielding effects, for dust grains of the considered high-Z metals is calculated as function of plasma parameters. The thermal bifurcation triggered by thermionic electron emission from dust grains, observed for some of the considered materials, is analyzed. The results are compared with previous calculations for dust composed of low-Z fusion related materials, i.e., lithium, beryllium, and carbon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tunable vacuum ultraviolet laser based spectrometer for angle resolved photoemission spectroscopy

We have developed an angle-resolved photoemission spectrometer with tunable vacuum ultraviolet laser as a photon source. The photon source is based on the fourth harmonic generation of a near IR beam from a Ti:sapphire laser pumped by a CW green laser and tunable between 5.3 eV and 7 eV. The most important part of the set-up is a compact, vacuum enclosed fourth harmonic generator based on potassium beryllium fluoroborate crystals, grown hydrothermally in the US. This source can deliver a photon flux of over 10{sup 14} photon/s. We demonstrate that this energy range is sufficient to measure the k{sub z} dispersion in an iron arsenic high temperature superconductor, which was previously only possible at synchrotron facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of coherence length and incoherent source size of hard x-ray undulator beamline at Pohang Light Source-II

We measured the spatial coherence length and incoherent source size of a hard x-ray undulator beamline at Pohang Light Source-II, the stored electron energy of which has been increased from 2.5 GeV to 3 GeV. The coherence length was determined by single-slit measurement of the visibility of the Fresnel diffraction pattern. The correlated incoherent source size was cross-checked for three different optics: the single slit, beryllium parabolic compound refractive lenses, and the Fresnel zone plate. We concluded that the undulator beamline has an effective incoherent source size (FWHM) of 540 μm (horizontal) × 50 μm (vertical)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-dependent restricted-active-space self-consistent-field singles method for many-electron dynamics

The time-dependent restricted-active-space self-consistent-field singles (TD-RASSCF-S) method is presented for investigating TD many-electron dynamics in atoms and molecules. Adopting the SCF notion from the muticonfigurational TD Hartree-Fock (MCTDHF) method and the RAS scheme (single-orbital excitation concept) from the TD configuration-interaction singles (TDCIS) method, the TD-RASSCF-S method can be regarded as a hybrid of them. We prove that, for closed-shell N{sub e}-electron systems, the TD-RASSCF-S wave function can be fully converged using only N{sub e}/2 + 1 ⩽ M ⩽ N{sub e} spatial orbitals. Importantly, based on the TD variational principle, the converged TD-RASSCF-S wave function with M = N{sub e} is more accurate than the TDCIS wave function. The accuracy of the TD-RASSCF-S approach over the TDCIS is illustrated by the calculation of high-order harmonic generation spectra for one-dimensional models of atomic helium, beryllium, and carbon in an intense laser pulse. The electronic dynamics during the process is investigated by analyzing the behavior of electron density and orbitals. The TD-RASSCF-S method is accurate, numerically tractable, and applicable for large systems beyond the capability of the MCTDHF method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space-resolved extreme ultraviolet spectroscopy free of high-energy neutral particle noise in wavelength range of 10–130 Å on the large helical device

A flat-field space-resolved extreme ultraviolet (EUV) spectrometer system working in wavelength range of 10–130 Å has been constructed in the Large Helical Device (LHD) for profile measurements of bremsstrahlung continuum and line emissions of heavy impurities in the central column of plasmas, which are aimed at studies on Z{sub eff} and impurity transport, respectively. Until now, a large amount of spike noise caused by neutral particles with high energies (≤180 keV) originating in neutral beam injection has been observed in EUV spectroscopy on LHD. The new system has been developed with an aim to delete such a spike noise from the signal by installing a thin filter which can block the high-energy neutral particles entering the EUV spectrometer. Three filters of 11 μm thick beryllium (Be), 3.3 μm thick polypropylene (PP), and 0.5 μm thick polyethylene terephthalate (PET: polyester) have been examined to eliminate the spike noise. Although the 11 μm Be and 3.3 μm PP filters can fully delete the spike noise in wavelength range of λ ≤ 20 Å, the signal intensity is also reduced. The 0.5 μm PET filter, on the other hand, can maintain sufficient signal intensity for the measurement and the spike noise remained in the signal is acceptable. As a result, the bremsstrahlung profile is successfully measured without noise at 20 Å even in low-density discharges, e.g., 2.9 × 10{sup 13} cm{sup −3}, when the 0.5 μm PET filter is used. The iron n = 3–2 Lα transition array consisting of FeXVII to FeXXIV is also excellently observed with their radial profiles in wavelength range of 10–18 Å. Each transition in the Lα array can be accurately identified with its radial profile. As a typical example of the method a spectral line at 17.62 Å is identified as FeXVIII transition. Results on absolute intensity calibration of the spectrometer system, pulse height and noise count analyses of the spike noise between holographic and ruled gratings and wavelength response of the used filters are also presented with performance of the present spectrometer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Can mirror matter solve the the cosmological lithium problem?

The abundance of lithium-7 confronts cosmology with a long lasting inconsistency between the predictions of standard Big Bang Nucleosynthesis with the baryonic density determined from the Cosmic Microwave Background observations on the one hand, and the spectroscopic determination of the lithium-7 abundance on the other hand. We investigated the influence of the existence of a mirror world, focusing on models in which mirror neutrons can oscillate into ordinary neutrons. Such a mechanism allows for an effective late time neutron injection, which induces an increase of the destruction of beryllium-7and thus a lower final lithium-7 abundance.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of neutron spectra generated from bombardment of 4 to 24 MeV protons on a thick {sup 9}Be target and estimation of neutron yields

A systematic study on the measurement of neutron spectra emitted from the interaction of protons of various energies with a thick beryllium target has been carried out. The measurements were carried out in the forward direction (at 0° with respect to the direction of protons) using CR-39 detectors. The doses were estimated using the in-house image analyzing program autoTRAK-n, which works on the principle of luminosity variation in and around the track boundaries. A total of six different proton energies starting from 4 MeV to 24 MeV with an energy gap of 4 MeV were chosen for the study of the neutron yields and the estimation of doses. Nearly, 92% of the recoil tracks developed after chemical etching were circular in nature, but the size distributions of the recoil tracks were not found to be linearly dependent on the projectile energy. The neutron yield and dose values were found to be increasing linearly with increasing projectile energies. The response of CR-39 detector was also investigated at different beam currents at two different proton energies. A linear increase of neutron yield with beam current was observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10{sup −3})D{sup 0.41} l h{sup ‑1} A{sup −1}. A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high-field horizontal magnet. The variable-temperature system is based on the use of an inverted insulating cup that operates above 4.2 K in liquid helium and above 77.4 K in liquid nitrogen, with a stability of ±80 mK to ±150 mK. Uniaxial strains of −1.4% to 1.0% can be applied to the sample, with a total uncertainty of better than ±0.02%, using a modified bending beam apparatus which includes a copper beryllium springboard-shaped sample holder.

43 PARTICLE ACCELERATORS↗

Energy relaxation of multi-MeV protons traveling in compressed DT+Be plasmas

We investigate the stopping power of the multi-MeV protons moving in the hot dense deuterium-tritium plasmas mixed with beryllium (Be), which is important in inertial confinement fusion experiments. It is shown that with increasing the density of Be, the stopping power of the proton also increases with the peaks shifting towards higher projectile velocity, which leads to the reduction of both the projectile range and the energy transferred to the electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and initial operation of a two-color soft x-ray camera system on the Compact Toroidal Hybrid experiment

A multi-camera soft x-ray diagnostic has been developed to measure the equilibrium electron temperature profile and temperature fluctuations due to magnetohydrodynamic activity on the Compact Toroidal Hybrid experiment. The diagnostic consists of three separate cameras each employing two 20-channel diode arrays that view the same plasma region through different beryllium filter thicknesses of 1.8 μm and 3.0 μm allowing electron temperature measurements between 50 eV and 200 eV. The Compact Toroidal Hybrid is a five-field period current-carrying stellarator, in which the presence of plasma current strongly modifies the rotational transform and degree of asymmetry of the equilibrium. Details of the soft x-ray emission, effects of plasma asymmetry, and impurity line radiation on the design and measurement of the two-color diagnostic are discussed. Preliminary estimates of the temperature perturbation due to sawtooth oscillations observed in these hybrid discharges are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion alpha-particle diagnostics for DT experiments on the joint European torus

JET equipped with ITER-like wall (a beryllium wall and a tungsten divertor) can provide auxiliary heating with power up to 35MW, producing a significant population of α-particles in DT operation. The direct measurements of alphas are very difficult and α-particle studies require a significant development of dedicated diagnostics. JET now has an excellent set of confined and lost fast particle diagnostics for measuring the α-particle source and its evolution in space and time, α-particle energy distribution, and α-particle losses. This paper describes how the above mentioned JET diagnostic systems could be used for α-particle measurements, and what options exist for keeping the essential α-particle diagnostics functioning well in the presence of intense DT neutron flux. Also, α-particle diagnostics for ITER are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical dumps for H-alpha and visible spectroscopy in ITER

High-reflective Beryllium cover of ITER first wall (R≈30–60%) causes remarkable increase of divertor stray light component (DSL). Optical dumps are well-known solution for DSL attenuation. In this work few types of optical dumps have been examined both by modeling and experimental studies. Taking into account the limitations, induced by ITER first wall design, OD optimized design has been proposed which could decrease divertor stray light component by 10..100 times depending on incidence angle of light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A combined kick-out and dissociative diffusion mechanism of grown-in Be in InGaAs and InGaAsP. A new finite difference-Bairstow method for solution of the diffusion equations

Experimental results on the diffusion of grown-in beryllium (Be) in indium gallium arsenide (In{sub 0.53}Ga{sub 0.47}As) and indium gallium arsenide phosphide (In{sub 0.73}Ga{sub 0.27}As{sub 0.58}P{sub 0.42}) gas source molecular beam epitaxy alloys lattice-matched to indium phosphide (InP) can be successfully explained in terms of a combined kick-out and dissociative diffusion mechanism, involving neutral Be interstitials (Be{sub i}{sup 0}), singly positively charged gallium (Ga), indium (In) self-interstitials (I{sub III}{sup +}) and singly positively charged Ga, In vacancies (V{sub III}{sup +}). A new numerical method of solution to the system of diffusion equations, based on the finite difference approximations and Bairstow's method, is proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An electrochemical cell for in operando studies of lithium/sodium batteries using a conventional x-ray powder diffractometer

An electrochemical cell has been designed for powder X-ray diffraction studies of lithium ion batteries (LIB) and sodium ion batteries (SIB) in operando with high time resolution using a conventional powder X-ray diffractometer. The cell allows for studies of both anode and cathode electrode materials in reflection mode. The cell design closely mimics that of standard battery testing coin cells and allows obtaining powder X-ray diffraction patterns under representative electrochemical conditions. In addition, the cell uses graphite as the X-ray window instead of beryllium, and it is easy to operate and maintain. Test examples on lithium insertion/extraction in two spinel-type LIB electrode materials (Li{sub 4}Ti{sub 5}O{sub 12} anode and LiMn{sub 2}O{sub 4} cathode) are presented as well as first results on sodium extraction from a layered SIB cathode material (Na{sub 0.84}Fe{sub 0.56}Mn{sub 0.44}O{sub 2})

36 MATERIALS SCIENCE↗

Installation of soft X-ray array diagnostics and its application to tomography reconstruction using synthetic KSTAR X-ray images

Four-array system of soft X-ray diagnostics was installed on KSTAR tokamak. Each array has 32 viewing chords of two photo-diode array detectors with spatial resolution of 2 cm. To estimate signals from the soft X-ray radiation power, typical n{sub e}, T{sub e}, and argon impurity line radiation profiles in KSTAR are chosen. The photo-diodes were absolutely calibrated as a function of the incident photon energy in 2–40 keV range with a portable X-ray tube. Two-dimensional T{sub e} image properties by multi-energy method were simulated and visualized with six combinations of beryllium filter sets within the dynamic range of signal ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploration of stable compounds, crystal structures, and superconductivity in the Be-H system

Using first-principles variable-composition evolutionary methodology, we explored the high-pressure structures of beryllium hydrides between 0 and 400 GPa. We found that BeH{sub 2} remains the only stable compound in this pressure range. The pressure-induced transformations are predicted as Ibam→P3{sup -}m1→R3{sup -}m→Cmcm→P4/nmm, which occur at 24, 139, 204 and 349 GPa, respectively. P3{sup -}m1 and R3{sup -}m structures are layered polytypes based on close packings of H atoms with Be atoms filling all octahedral voids in alternating layers. Cmcm and P4/nmm contain two-dimensional triangular networks with each layer forming a kinked slab in the ab-plane. P3{sup -}m1 and R3{sup -}m are semiconductors while Cmcm and P4/nmm are metallic. We have explored superconductivity of both metal phases, and found large electron-phonon coupling parameters of λ = 0.63 for Cmcm with a T{sub c} of 32.1-44.1 K at 250 GPa and λ = 0.65 for P4/nmm with a T{sub c} of 46.1-62.4 K at 400 GPa. The dependence of T{sub c} on pressure indicates that T{sub c} initially increases to a maximum of 45.1 K for Cmcm at 275 GPa and 97.0 K for P4/nmm at 365 GPa, and then decreases with increasing pressure for both phases.

36 MATERIALS SCIENCE↗

Theoretical studies on the stopping power of deuterium-tritium mixed with uranium plasmas for α particles

The stopping power of a compressed and highly ionized deuterium-tritium (DT) and uranium (U) plasma for α particles at very high temperatures (T = 5 keV) is examined theoretically with the dimensional continuation method. We show that with increasing density of U, both the magnitude and width of the resonance peak in the stopping power (as a function of the α particle energy), increases because of the ions, while the penetration distance of the α particles decreases. A simple relation of decreasing penetration distance as a function of plasma density is observed, which may be useful for inertial confinement fusion experiments. Moreover, by comparing the results with the case of a DT plasma mixed with beryllium, we find that the effect of a higher Z plasma is stronger, with regard to energy loss as well as the penetration distance of α particles, than that of a lower Z plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processes and properties of edge-localised instabilities in 2T 2MA plasmas in the Joint European Torus

During July 2012, 150 almost identical H-mode plasmas were consecutively created in the Joint European Torus, providing a combined total of approximately 8 minutes of steady-state plasma with 15 000 Edge Localised Modes (ELMs). In principle, each of those 15 000 ELMs are statistically equivalent. Here, the changes in edge density and plasma energy associated with those ELMs are explored, using the spikes in Beryllium II (527 nm) radiation as an indicator for the onset of an ELM. Clearly different timescales are observed during the ELM process. Edge temperature falls over a 2 ms timescale, edge density and pressure fall over a 5 ms timescale, and there is an additional 10 ms timescale that is consistent with a resistive relaxation of the plasma's edge. The statistical properties of the energy and density losses due to the ELMs are explored. For these plasmas the ELM energy (δE) is found to be approximately independent of the time between ELMs, despite the average ELM energy (〈δE〉) and average ELM frequency (f) being consistent with the scaling of 〈δE〉∝1/f. Instead, beyond the first 0.02 s of waiting time between ELMs, the energy losses due to individual ELMs are found to be statistically the same. Surprisingly no correlation is found between the energies of consecutive ELMs either. A weak link is found between the density drop and the ELM waiting time. Consequences of these results for ELM control and modelling are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗