Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below- threshold ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Photoneutron cross sections for {sup 96}Zr: A systematic experimental study of photoneutron and radiative neutron capture cross sections for zirconium isotopes

Photoneutron cross sections were measured for {sup 96}Zr near neutron threshold with quasimonochromatic laser-Compton-scattering {gamma}-ray beams. A systematic analysis of photoneutron and radiative neutron capture data for zirconium isotopes within the statistical model calculation leads to a unified picture of low-energy {gamma}-ray strengths for zirconium isotopes that is described by the HFB + QRPA model of E1 strength supplemented with an extra {gamma} strength attributed to a giant M1 resonance. Results of the systematic analysis including radiative neutron capture cross sections for radioactive {sup 95}Zr and {sup 93}Zr nuclei are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytical electron microscopy investigation of elemental composition and bonding structure at the Sb-doped Ni-fully-silicide/SiO{sub 2} interface

It is very important to control the elemental composition and bonding structure at the gate electrode/gate dielectrics interface in metal-oxide-semiconductor transistor devices because this determines the threshold voltage of the gate electrode. In this study, we investigated the structure at the interface between the antimony (Sb)-doped nickel-fully-silicide gate electrode and SiO{sub 2} dielectrics by employing high-spatial resolution techniques such as energy dispersive x-ray spectroscopy and electron energy-loss spectroscopy using a scanning transmission electron microscope. In one region, we found a thin nickel layer at the NiSi/SiO{sub 2} interface originating from the migration of native oxide at the face of the poly-silicon. In another region, a Sb pileup was detected at the NiSi/SiO{sub 2} interface where the Ni L{sub 3}-edge spectrum showed Ni-Sb bonding, then it was suggested that Sb atoms exist at the bottom of NiSi, substituting for Si atoms in NiSi.

36 MATERIALS SCIENCE↗

SU-F-T-564: 3 Year Experience of Treatment Plan QualityAssurance for Vero SBRT Patients

Purpose: To verify treatment plan monitor units from iPlan treatment planning system for Vero Stereotactic Body Radiotherapy (SBRT) treatment using both software-based and (homogeneous and heterogeneous) phantom-based approaches. Methods: Dynamic conformal arcs (DCA) were used for SBRT treatment of oligometastasis patients using Vero linear accelerator. For each plan, Monte Carlo calculated treatment plans MU (prescribed dose to water with 1% variance) is verified first by RadCalc software with 3% difference threshold. Beyond 3% differences, treatment plans were copied onto (homogeneous) Scanditronix phantom for non-lung patients and copied onto (heterogeneous) CIRS phantom for lung patients and the corresponding plan dose was measured using a cc01 ion chamber. The difference between the planed and measured dose was recorded. For the past 3 years, we have treated 180 patients with 315 targets. Out of these patients, 99 targets treatment plan RadCalc calculation exceeded 3% threshold and phantom based measurements were performed with 26 plans using Scanditronix phantom and 73 plans using CIRS phantom. Mean and standard deviation of the dose differences were obtained and presented. Results: For all patient RadCalc calculations, the mean dose difference is 0.76% with a standard deviation of 5.97%. For non-lung patient plan Scanditronix phantom measurements, the mean dose difference is 0.54% with standard deviation of 2.53%; for lung patient plan CIRS phantom measurements, the mean dose difference is −0.04% with a standard deviation of 1.09%; The maximum dose difference is 3.47% for Scanditronix phantom measurements and 3.08% for CIRS phantom measurements. Conclusion: Limitations in secondary MU check software lead to perceived large dose discrepancies for some of the lung patient SBRT treatment plans. Homogeneous and heterogeneous phantoms were used in plan quality assurance for non-lung patients and lung patients, respectively. Phantom based QA showed the relative good agreement between iPlan calculated dose and measured dose.

60 APPLIED LIFE SCIENCES↗

Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The information acquired for repositioning using combined MV-kV images was found to have submillimeter accuracy. Conclusions: This work demonstrated with a current clinical setup that substantial reduction of adverse targeting effects of intrafraction prostate motion can be realized. The proposed adaptive imaging strategy incurs minimal imaging dose to the patient as compared to other stereoscopic imaging techniques.

60 APPLIED LIFE SCIENCES↗

Validity of the Wannier threshold law for angular correlation width in double photoionization of atoms

We calculated using the ab initio method the three-fold differential cross section of a single-photon double photoionization of helium at equal energy sharing and derived the Gaussian width parameter {gamma}, describing the angular interelectron correlations, for the total electron energy E ranging from 0.1 to 100 eV. The results are in perfect agreement with experimental data. Contrary to common expectations, the results demonstrate that the Wannier threshold law for the Gaussian width parameter {gamma}{proportional_to}E{sup 1/4} is not correct at energies attainable in modern experiments. It is shown that the {gamma} dependence on the energy is much better described by the modified threshold law, obtained by Kazansky and Ostrovsky [J. Phys. B 26, 2231 (1993)]. Also, we explored the Gaussian width parameter for double photoionization of targets with strongly asymmetrical initial-state configuration: the atomic hydrogen negative ion H{sup -} and the helium atom in the 2s {sup 1}S and 3s {sup 1}S excited states. We found that the Gaussian width dependence on the total ejected electron energy for these targets has a maximum at low energies. We also show that the correlation parameter dependence on the interelectron angle for these targets is essentially non-Gaussian and has a number of peaks equal to the number of the initial-state radial nodes, which provide new facilities for the qualitative analysis of the electron structure of the target atom.

74 ATOMIC AND MOLECULAR PHYSICS↗

Highly Contrasting Static Charging and Bias Stress Effects in Pentacene Transistors with Polystyrene Heterostructures Incorporating Oxidizable N , N '-Bis(4-methoxyphenyl)aniline Side Chains as Gate Dielectrics

Charge storage and trapping properties of polymer dielectrics govern the charge densities of adjacent semiconductors and greatly influence the on-off switching voltage (threshold voltage, V th ) of organic field-effect transistors (OFETs) when the polymers are used as gate insulators. Intentional charging of polymer dielectrics in OFETs can change V th and affect the bias stress. We describe a chemical design and fabrication protocol to construct multilayer-stack dielectrics for pentacene-based OFETs using different polystyrene (PS)-based polymers in each layer, with oxidizable N,N-bis(4-methoxyphenyl)anilino (TPAOMe)-substituted styrene copolymers in arbitrary vertical positions in the stacks. Thermal, byproduct-free crosslinking of benzocyclobutene subunits provides integrity to the multilayer structure by preventing dissolution of the previous deposited layer. Neutron reflectivity data verified the multilayer morphology. We compared the Vth shift before and after charging the stacks by application of ±100V across 0.5-1 µm total film thicknesses. Bias stress was the dominant effect in bilayer devices with a TPAOMe layer in contact with the pentacene, indicated by the direction of V th shift associated with either polarity of external electric field. In structures with no TPAOMe subunit in contact with the pentacene, when charging with -100V on top of the source and drain electrodes, electron injection from pentacene to dielectric was the major charging mechanism, again consistent with the bias stress direction. When charging with +100V, bilayer devices without TPAOMe showed little change in V th , suggesting there was no bias stress effect or charge injection in these devices for this charging polarity. For the bilayer devices with the TPAOMe layer in the bottom, and the trilayer devices with TPOMe in the middle, when +100V was applied, the V th shifts were opposite those expected from bias stress. Dipole formation or partial ionization of chargeable groups at the interface between the dielectric layers are likely polarization mechanisms in these cases. A simple analytical model supports the plausibility of these mechanisms. This work provides examples of both stabilization and shifting of V th , and therefore controlling charge carrier density, in semiconductors overlying the dielectric multilayers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure-dependent transition from atoms to nanoparticles in magnetron sputtering: Effect on WSi{sub 2} film roughness and stress

We report on the transition between two regimes from several-atom clusters to much larger nanoparticles in Ar magnetron sputter deposition of WSi{sub 2}, and the effect of nanoparticles on the properties of amorphous thin films and multilayers. Sputter deposition of thin films is monitored by in situ x-ray scattering, including x-ray reflectivity and grazing incidence small-angle x-ray scattering. The results show an abrupt transition at an Ar background pressure P{sub c}; the transition is associated with the threshold for energetic particle thermalization, which is known to scale as the product of the Ar pressure and the working distance between the magnetron source and the substrate surface. Below P{sub c} smooth films are produced while above P{sub c} roughness increases abruptly, consistent with a model in which particles aggregate in the deposition flux before reaching the growth surface. The results from WSi{sub 2} films are correlated with in situ measurement of stress in WSi{sub 2}/Si multilayers, which exhibits a corresponding transition from compressive to tensile stress at P{sub c}. The tensile stress is attributed to coalescence of nanoparticles and the elimination of nanovoids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rovibrationally selected ion-molecule collision study using the molecular beam vacuum ultraviolet laser pulsed field ionization-photoion method: Charge transfer reaction of N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2; N{sup +}= 0-9) + Ar

We have developed an ion-molecule reaction apparatus for state-selected absolute total cross section measurements by implementing a high-resolution molecular beam vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) ion source to a double-quadrupole double-octopole ion-guide mass spectrometer. Using the total cross section measurement of the state-selected N{sub 2}{sup +}(v{sup +}, N{sup +}) + Ar charge transfer (CT) reaction as an example, we describe in detail the design of the VUV laser PFI-PI ion source used, which has made possible the preparation of reactant N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}, v{sup +}= 0-2, N{sup +}= 0-9) PFI-PIs with high quantum state purity, high intensity, and high kinetic energy resolution. The PFI-PIs and prompt ions produced in the ion source are shown to have different kinetic energies, allowing the clean rejection of prompt ions from the PFI-PI beam by applying a retarding potential barrier upstream of the PFI-PI source. By optimizing the width and amplitude of the pulsed electric fields employed to the VUV-PFI-PI source, we show that the reactant N{sub 2}{sup +} PFI-PI beam can be formed with a laboratory kinetic energy resolution of {Delta}E{sub lab}={+-} 50 meV. As a result, the total cross section measurement can be conducted at center-of-mass kinetic energies (E{sub cm}'s) down to thermal energies. Absolute total rovibrationally selected cross sections {sigma}(v{sup +}= 0-2, N{sup +}= 0-9) for the N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2, N{sup +}= 0-9) + Ar CT reaction have been measured in the E{sub cm} range of 0.04-10.0 eV, revealing strong vibrational enhancements and E{sub cm}-dependencies of {sigma}(v{sup +}= 0-2, N{sup +}= 0-9). The thermochemical threshold at E{sub cm}= 0.179 eV for the formation of Ar{sup +} from N{sub 2}{sup +}(X; v{sup +}= 0, N{sup +}) + Ar was observed by the measured {sigma}(v{sup +}= 0), confirming the narrow {Delta}E{sub cm} spread achieved in the present study. The {sigma}(v{sup +}= 0-2; N{sup +}) values obtained here are compared with previous experimental and theoretical results. The theoretical predictions calculated based on the Landau-Zener-Stueckelberg formulism are found to be in fair agreement with the present measured {sigma}(v{sup +}= 1 or 2; N{sup +}). Taking into account of the experimental uncertainties, the measured {sigma}(v{sup +}= 1 or 2, N{sup +}) for N{sup +}= 0-9 at E{sub cm}= 0.04-10.0 eV are found to be independent of N{sup +}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Structure of {sup 12}C from Break-up Studies in Complete Kinematics

A complete kinematics study of the {sup 10}B({sup 3}He,palphaalphaalpha) and {sup 11}B({sup 3}He,dalphaalphaalpha) reactions has been performed to study the multi-particle break-up of {sup 12}C resonances above the triple-alpha threshold. Four-particle coincidence detection gives us complete information on the direction and energy of the individual alpha particles from the decay of {sup 12}C, allowing us to extract new information on the structure of {sup 12}C which we shall present in this contribution. We have observed gamma de-excitation of the T = 1 15.11 MeV resonance using charged particle detectors, and have constructed Dalitz plots of the individual resonances in {sup 12}C using the complete kinematics information of the alpha particles which come from their break-up.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interaction of vacuum ultraviolet excimer laser radiation with fused silica. I. Positive ion emission

We report time- and mass-resolved measurements of Si{sup +} and O{sup +} emission from ultraviolet-grade fused silica during exposure to pulsed 157 nm excimer laser radiation at fluences below the threshold for optical breakdown. The emission intensities are increased by treatments that increase the density of surface defects, such as abrasion, and are reduced by treatments that reduce the density of surface defects, such as annealing. Ion emission is a sensitive probe of mechanical damage on silica surfaces. The mean ion kinetic energies are typically several eV: 8-9 eV for Si{sup +} and about 4 eV for O{sup +}. Hartree-Fock studies of candidate defect sites suggest that antibonding states excited by 157 nm photons play a critical role in the release of these ions. We propose that positive ion emission from fused silica under these conditions is best explained by a hybrid mechanism involving (a) the excitation of an antibonding chemical state (Menzel-Gomer-Redhead mechanism) and (b) the acceleration of the positive ion by repulsive electrostatic forces due to the photoionization of nearby electron traps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structure and three-body decay of {sup 9}Be resonances

The complex-rotated hyperspherical adiabatic method is used to study the decay of low-lying {sup 9}Be resonances into one neutron and two {alpha} particles. We investigate the six resonances above the breakup threshold and below 6 MeV: 1/2{sup {+-},} 3/2{sup {+-},} and 5/2{sup {+-}.} The short-distance properties of each resonance are studied, and the different angular momentum and parity configurations of the {sup 8}Be and {sup 5}He two-body substructures are determined. We compute the branching ratio for sequential decay via the {sup 8}Be ground state, which qualitatively is consistent with measurements. We extract the momentum distributions after decay directly into the three-body continuum from the large-distance asymptotic structures. The kinematically complete results are presented as Dalitz plots as well as projections on given neutron and {alpha} energy. The distributions are discussed and, in most cases, found to agree with available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonant Raman scattering of polarized and unpolarized x-ray radiation from Mg, Al, and Si

The x-ray resonant Raman scattering (RRS) effect of polarized and unpolarized radiation in the vicinity of the 1s absorption threshold of low-Z elements such as magnesium, aluminum, and silicon is investigated. For the polarized and tunable exciting x-ray radiation the plane grating monochromator (PGM) beam line at the PTB laboratory in the BESSY II synchrotron radiation facility was employed, while unpolarized x-ray beams were induced by 1-MeV proton beam irradiation on various pure thick targets. For the latter case, a novel proton-induced x-ray fluorescence scattering chamber was designed and installed at the Tandem accelerator laboratory of the Institute of Nuclear Physics at N.C.S.R. 'Demokritos'. The total RRS cross sections deduced from both independent excitation modes were found to be in a good agreement, within the experimental uncertainties. The predictions of the existing theory with respect to the dependence of the RRS to the incident beam polarization state is calculated and discussed with respect to the experimental results.

36 MATERIALS SCIENCE↗

Low-threshold anti-Stokes frequency conversion in Zn{sub 0.6}Cd{sub 0.4}S microcrystals with adsorbed metal-organic nanoclusters

We demonstrate the feasibility of low-threshold (10{sup -4} to 10{sup -2} W cm{sup -2}) anti-Stokes conversion of photons in the range 1.72 - 2.00 eV to luminescence at 2.14 - 2.38eV at temperatures from 77 to 300 K in Zn{sub 0.6}Cd{sub 0.4}S crystals with nanoscale complexes of dye molecules and silver subnanoclusters adsorbed on their surface. The spectral characteristics of the centres involved in anti-Stokes frequency conversion indicate that this process in the crystals studied is due to sequential two-photon interband optical transitions. The absorption of a photon by a dye molecule and electron excitation transfer to an adsorbed silver subnanocluster produce a free hole in the valence band. Subsequent photoionisation of the subnanocluster produces a free electron. The last step of the anti-Stokes frequency conversion process is radiative recombination of the electron with a hole localised at an emission centre. (nonlinear-optics phenomena)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE PROPERTIES OF X-RAY COLD FRONTS IN A STATISTICAL SAMPLE OF SIMULATED GALAXY CLUSTERS

We examine the incidence of cold fronts in a large sample of galaxy clusters extracted from a (512 h {sup -1} Mpc) hydrodynamic/N-body cosmological simulation with adiabatic gas physics computed with the Enzo adaptive mesh refinement code. This simulation contains a sample of roughly 4000 galaxy clusters with M {>=}10{sup 14} M{sub sun} at z = 0. For each simulated galaxy cluster, we have created mock 0.3-8.0 keV X-ray observations and spectroscopic-like temperature maps. We have searched these maps with a new automated algorithm to identify the presence of cold fronts in projection. Using a threshold of a minimum of 10 cold front pixels in our images, corresponding to a total comoving length L{sub cf}>156 h {sup -1} kpc, we find that roughly 10%-12% of all projections in a mass-limited sample would be classified as cold front clusters. Interestingly, the fraction of clusters with extended cold front features in our synthetic maps of a mass-limited sample trends only weakly with redshift out to z = 1.0. However, when using different selection functions, including a simulated flux limit, the trending with redshift changes significantly. The likelihood of finding cold fronts in the simulated clusters in our sample is a strong function of cluster mass. In clusters with M>7.5 x 10{sup 14} M{sub sun} the cold front fraction is 40%-50%. We also show that the presence of cold fronts is strongly correlated with disturbed morphology as measured by quantitative structure measures. Finally, we find that the incidence of cold fronts in the simulated cluster images is strongly dependent on baryonic physics.

79 ASTRONOMY AND ASTROPHYSICS↗

VMAT QA: Measurement-guided 4D dose reconstruction on a patient

Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of the 4D MGDR with global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

60 APPLIED LIFE SCIENCES↗

Structure of {sup 30}S with {sup 32}S(p,t){sup 30}S and the thermonuclear {sup 29}P(p,{gamma}){sup 30}S reaction rate

The structure of proton unbound {sup 30}S states is important for determining the {sup 29}P(p,{gamma}){sup 30}S reaction rate, which influences explosive hydrogen burning in classical novae and type I x-ray bursts. The reaction rate in this temperature regime had been previously predicted to be dominated by two low-lying, unobserved, J{sup {pi}=} 3{sup +} and 2{sup +} resonances above the proton threshold in {sup 30}S. To search for these levels, the structure of {sup 30}S was studied using the {sup 32}S(p,t){sup 30}S transfer reaction with a magnetic spectrograph. We have confirmed a previous detection of a state near 4700 keV, which had tentatively been assigned J{sup {pi}=}3{sup +}. We have also discovered a new state at 4814(3) keV, which is a strong candidate for the other important resonance (J{sup {pi}=}2{sup +}). The new {sup 29}P(p,{gamma}){sup 30}S reaction rate is up to 4-20 times larger than previously determined rates over the relevant temperature range. The uncertainty in the reaction rate due to uncertainties in the resonance energies has been significantly reduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE IMPACT OF COLD GAS ACCRETION ABOVE A MASS FLOOR ON GALAXY SCALING RELATIONS

Using the cosmological baryonic accretion rate and normal star formation (SF) efficiencies, we present a very simple model for star-forming galaxies that accounts for the mass and redshift dependences of the star formation rate (SFR)-mass and Tully-Fisher (TF) relations from z {approx} 2 to the present. The time evolution follows from the fact that each modeled galaxy approaches a steady state where the SFR follows the (net) cold gas accretion rate. The key feature of the model is a halo mass floor M {sub min} {approx_equal} 10{sup 11} M{sub sun} below which accretion is quenched in order to simultaneously account for the observed slopes of the SFR-mass and TF relations. The same successes cannot be achieved via an SF threshold (or delay) nor by varying the SF efficiency or the feedback efficiency. Combined with the mass ceiling for cold accretion due to virial shock heating, the mass floor M{sub min} explains galaxy 'downsizing', where more massive galaxies formed earlier and over a shorter period of time. It turns out that the model also accounts for the observed galactic baryon and gas fractions as a function of mass and time, and the cosmic SFR density, which are all resulting from the mass floor M {sub min}. The model helps us to understand that it is the cosmological decline of accretion rate that drives the decrease of cosmic SFR density between z {approx} 2 and z = 0 and the rise of the cosmic SFR density from z {approx} 6 to z {approx} 2 that allows us to put a constraint on our main parameter M {sub min} {approx_equal} 10{sup 11} M{sub sun}. Among the physical mechanisms that could be responsible for the mass floor, our view is that photoionization feedback (from first in situ hot stars) lowering the cooling efficiency is likely to play a large role.

79 ASTRONOMY AND ASTROPHYSICS↗