Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “appendix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Design of a modified Halbach magnet for the CBETA Project

A modified Halbach magnet has been designed to be installed in the splitter/merger section of the CBETA project which is under construction at Cornell University. The splitter/merger of the CBETA consists of 4 beam lines and is shown in Fig. 1. Two of the functions of the splitter/merger lines are; first to match the beam parameters at the exit of the Energy Recovery Linac (ERL) to those at the entrance of the Fixed Field Alternating Gradient (FFAG) arc, and second to place the trajectories of the reference particles of the beam bunches at the entrance of the FFAG arc on specified trajectories as they determined by the beam optics of the FFAG arc. In this technical note we present results from the 2D and 3D electromagnetic analysis of the S4.BEN01 magnet which is one of the dipole magnets of the 150 MeV line of the splitter/merger. The present design of the S4.BEN01 magnet, is based on a modified Halbach-type permanent magnet. To justify our suggestion of using a Halbach type of magnet instead of an electromagnet for the S4.BEN01 magnet we devote an APPENDIX A in which we provide details on the design of an electromagnet for the S4.BEN01 magnet and in the section under conclusion will list the pros and cons of the two designs.

43 PARTICLE ACCELERATORS↗

ARM Aerosol Measurement Plan

Over the past decade, the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility has been working toward developing a comprehensive (defined here as Tiers I-III in Appendix A) and consistent set of aerosol measurements across each of the ARM ground-based observatories. Along the way, the facility has deployed wide-ranging instruments including some for which ARM has had many years of operating experience and some which represent more cutting-edge capabilities. While there has been a clear motivation for this instrument suite, the adoption of these instruments has not been uniform. The reasons for this vary and include operational challenges, measurement complexity, and alignment with active research.

54 ENVIRONMENTAL SCIENCES↗

Radiological Exposure Devices (RED) Technical Basis for Threat Profile

Facilities that manufacture, store or transport significant quantities of radiological material must protect against the risk posed by sabotage events. Much of the analysis of this type of event has been focused on the threat from a radiological dispersion device (RDD) or "dirty bomb" scenario, in which a malicious assailant would, by explosives or other means, loft a significant quantity of radioactive material into a plume that would expose and contaminate people and property. Although the consequences in cost and psychological terror would be severe, no intentional RDD terrorism events are on record. Conversely, incidents in which a victim or victims were maliciously exposed to a Radiological Exposure Device (RED), without dispersal of radioactive material, are well documented. This paper represents a technical basis for the threat profile related to the risk of nefarious use of an RED, including assailant and material characterization. Radioactive materials of concern are detailed in Appendix A.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Andhra Pradesh [PowerPoint]

This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Gujarat

This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Karnataka

This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Maharashtra

This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Rajasthan

This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Regional Study: Tamil Nadu

This chapter on Tamil Nadu is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plants for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2017

Report submitted to regulators (State of Nevada and EPA Region IV). Required to document compliance with 40 CFR 61 Subpart H. The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since nuclear testing ended in 1992, radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA in 2001 (EPA 2001a) and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations because no member of the public resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR 2010a). For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2017, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by air sampling data collected at the critical receptor air monitoring stations which had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from 0.2% to a maximum of 5.7% of the allowed NESHAP limit. Clean Air Package 1988 (CAP88) was used to model dose to the offsite public from all 2017 NNSS radionuclide emissions. The model showed the maximally exposed individual to be on the adjacent U.S. Air Force Nevada Test and Training Range; this individual received a dose of 0.07 mrem/y. The potential dose to the public from NLVF emissions was also very low at 0.0000098 mrem/y, over six orders of magnitude lower than the 10 mrem/y limit.

07 ISOTOPE AND RADIATION SOURCES↗

Conceptual Silicon Beta Cell Design

Silicon detectors have the potential to significantly improve the sensitivity limits for radioxenon detection. While silicon has beneficial attributes like improved energy resolution and memory effect, the sensitivity improvements will not occur without a properly designed beta cell that utilizes silicon detectors. This report details the key parameters that have been incorporated into the design of a silicon beta cell. Parameters that have the potential to change as a prototype silicon beta cell is developed and during the future commercialization process are also discussed. The design of the silicon beta cell has focused primarily on simulations and analytical models to optimize the mechanical properties. Additionally, a team of experts provided guidance and potential alternatives for the silicon detectors and electronics fabrication. A conceptual design for a silicon beta cell was completed, with an emphasis on the modularity of the system. The modularity allows for any potential changes that may be of interest during the prototyping phase or future spiral development to be implemented with minimal impact on the complete system. The impact of the silicon based beta cell is discussed in the conclusions, along with potential next steps. Mechanical design drawings for the beta cell could be used to manufacture a prototype beta cell and are available in an appendix document.

36 MATERIALS SCIENCE↗

Response to External Peer Review Team Report for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada, Revision 1

The Underground Test Area (UGTA) Corrective Action Unit (CAU) 97, Yucca Flat/Climax Mine (YF/CM), in the northeast part of the Nevada National Security Site (NNSS) requires environmental corrective action activities to assess contamination resulting from underground nuclear testing. These activities are necessary to comply with the UGTA corrective action strategy defined in Appendix VI, Revision No. 4, of the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Phase I Flow and Transport Model Document for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada (N-I, 2013a) was developed and subjected to an external peer review as required by the corrective action investigation (CAI) stage of the UGTA strategy. The YF/CM Peer Review Committee (PRC) raised a number of questions and provided recommendations for supplemental analyses (in the External Peer Review Team Report for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada [N-I, 2015]). The purpose of this document is to provide responses to the PRC recommendations addressing the uncertainties identified by the PRC so that sufficient confidence in the contaminant boundary forecasts is established to advance to the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) stage and initiate model evaluations. The PRC summarized their concerns and recommendations, and presented discussions of each of these uncertainties in their report (N-I, 2015). The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) responses are summarized in Table ES-1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology for SNL Nuclear Facility Categorization

This administrative operating procedure (AOP) provides the process for performing the initial and final hazard categorization for a nuclear facility or activity to ensure compliance with 10 CFR 830.202. This AOP provides guidance on the application of the PHS process (refer to MN471017, Safety Basis Manual, Appendix NF-01,"Nuclear Facility Hazard Categorization") and describes the analyses that might be required to finalize a facility's hazard categorization.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Security on the Move: An Eligibility Assessment of the Manhattan Project National Historical Park's Portable Guard Shack (TA-8-172)

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (Field Office) proposes to assess, stabilize, and eventually restore a Manhattan Project-era guard shack to its original wartime condition. TA-8-172, a portable building, is a Manhattan Project National Historical Park property located in Technical Area (TA) 8 at Los Alamos National Laboratory (LANL). In compliance with Section 106 and Section 110 of the National Historic Preservation Act of 1966, as amended, LANL’s cultural resources staff completed the evaluation of Building TA-8- 172 for inclusion in the National Register of Historic Places (Register). A LANL historic building inventory form for the guard shack is included in Appendix A. The Field Office has determined that Building TA-8-172 is Register-eligible under Criteria A, B and C based on the findings in this assessment report. The Field Office is requesting concurrence from the State Historic Preservation Officer for TA- 8-172. The guard station will undergo a full condition assessment, and rehabilitation and repairs. These undertakings will receive future documentation and consultation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Calendar Year 2017 Underground Test Area Annual Sampling Report Nevada National Security Site, Nevada, Revision 1

This report presents the analytical data for the 2017 calendar year (CY) (January 1 through December 31, 2017) and an evaluation of the data to ensure that the Sampling Plan’s objectives are achieved. Data from samples collected in 2016 that were not reported in the UGTA CY 2016 Annual Sampling Analysis Report (DOE/EMNV, 2018b) are presented in Appendix D.

54 ENVIRONMENTAL SCIENCES↗

Final Report for the Contractor Readiness Assessment of the Transient Reactor Test Facility Resumption of Transient Testing Activity at the Idaho National Laboratory

The purpose of this review was to verify readiness for the TREAT restart of transient testing activity at the INL and inform the startup authorization authority decision-making for startup authorization by providing a deliberate and managed determination of the state of readiness preparation and determination of whether operations can be performed safely. Verification of readiness included assuring that equipment operability, procedure viability, and personnel knowledge, skills, and performance are adequate for operations. Because the TREAT (including restart of transient testing activity) is a hazard category-2 nuclear facility and because reactor operation and transient testing activities were suspended for programmatic and funding reasons in excess of a year, DOE O 425.1D required that both a contractor and DOE RA be satisfactorily completed prior to startup of the TREAT and restart of transient testing activity. To this end, DOE directed that a CRA and federal RA be conducted. The CRA IP defined the depth of the CRA through the objectives and CRADs, delineated in Appendix A of the IP; established roles and responsibilities for CRA team activities; and established processes, practices, and protocols for preparation, conduct, documentation, and reporting of the CRA. The approaches and methodologies identified in the IP were used to verify that the BEA management team has established SSCs, developed personnel capabilities and competencies, and implemented safety features, programs, and procedures in a manner that provides reasonable assurance for adequate protection of workers, the public, and the environment in preparation for and execution of the TREAT restart of transient testing activity. This CRA was intended to confirm that (1) the facility is in a state of readiness to safely conduct operations in accordance with the safety basis; and (2) the management control programs are in place to ensure safe operations can be sustained. This equated to mature implementation of the integrated safety management (ISM) in conjunction with implementation of the individual facility authorization basis. This CRA was structured to verify the readiness to conduct restart of transient testing activity safely, and that facility programs were in place to support the restart of transient testing activity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Particle Mass Flow Control for High-Temperature Concentrating Solar Receivers

This report summarizes the results of a two-year project funded by the U.S. Department of Energy's Solar Energy Technologies Office (SuNLaMP 1506) to evaluate the performance of high-temperature (>700 °C) particle receivers for concentrating solar power (see Appendix A for project information). In the first year, novel particle release patterns were designed and tested to increase the effective solar absorptance of the particle curtain. Modeling results showed that increasing the magnitude and frequency of different wave-like patterns increased the effective absorptance and thermal efficiency by several percentage points, depending on the mass flow rate. Tests showed that triangular-wave, square-wave, and parallel-curtain particle release patterns could be implemented and maintained at flow rates of ~10 kg/s/m. The second year of the project focused on the development and testing of particle mass-flow control and measurement methods. An automated slide gate controlled by the outlet temperature of the particles was designed and tested. Testing demonstrated that the resolution accuracy of the slide-gate positioning was less than ~1 mm, and the speed of the slide gate enabled rapid adjustments to accommodate changes in the irradiance to maintain a desired outlet temperature range. Different in-situ particle mass-flow measurement techniques were investigated, and two were tested. The in-situ microwave sensor was found to be unreliable and sensitive to variations in particle flow patterns. However, the in-situ weigh hopper using load cells was found to provide reliable and repeatable measurements of real-time in-situ particle mass flow. On-sun tests were performed to determine the thermal efficiency of the receiver as a function of mass flow rate, particle temperature, and irradiance. Models of the tests were also developed and compared to the tests.

14 SOLAR ENERGY↗

Off-Gas Condensate and Cast Stone Analysis Results

A sample of off-gas condensate produced during a demonstration test of the direct-feed low-activity waste (DFLAW) Radioactive Waste Test Platform using waste retrieved from Hanford storage tank AP-105 waste was analyzed for major cations, anions, total cyanide, Resource Conservation and Recovery Act (RCRA) metals, selected radionuclides, and selected organic compounds. The remaining off-gas condensate was concentrated through evaporation and then used to produce Cast Stone waste forms. After the solid waste forms cured for 28 days, U.S. Environmental Protection Agency (EPA) Method 1311 (EPA 1992) Toxicity Characteristic Leach Procedure (TCLP) tests were conducted on two samples. The TCLP leachates were analyzed for RCRA metals, fluoride, and total cyanide. These chemical analyses were conducted to collect data on the waste form performance and to determine if the waste form will meet the disposal requirements of the Waste Control Specialists LLC (WCS) Federal Waste Disposal Facility (FWF) in Texas (WCS 2015) and the Integrated Disposal Facility at Hanford. The radionuclide results in the off-gas condensate were used to estimate concentrations in the Cast Stone waste forms; these estimates were then compared to Class C limits (30 TAC 336.362 Appendix E). With the possible exception of U-232, all measured radionuclides were determined to be below their respective Class C limits. Inductively coupled plasma-mass spectrometry (ICP-MS) was used to measure most of the radionuclides. It is not possible to differentiate the isotope measured at mass 232 between U 232 and Th-232 by mass spectroscopy. Class C limit comparisons were made by assuming two maximum possible scenarios; one in which all the isotope at mass 232 occurred as Th-232, and another assigning the entire mass contribution to U-232. If the isotope at mass 232 is all Th-232 then the waste form is well below its Class C limit; however, if the isotope at mass 232 is all U-232, then the Class C limit would be exceeded by more than a factor of 8. A chemical procedure to separate uranium from thorium followed by reanalysis by ICP-MS would be required to resolve this issue. A similar issue occurs at mass 238, which could be U-238 or Pu-238; however, in this case Pu-238 can be ruled out as a contributor to the isotope measured at mass 238 for the following reasons. Pu-238 has a half-life of 87.7 years and its daughter product (U-234) has a half-life of 2.5 × 105 years and a measured concentration of < 0.002 µg/L. If significant concentrations of Pu-238 were present in this waste, then the amount of measurable U 234 would have increased over the decades of storage in the Hanford tanks. Because this was not observed, it is concluded that the isotope measured at mass 238 is all U-238. A total of 68 organic compounds were targeted for analysis in the off-gas condensate. Of these compounds, only nine were measured above their respective minimum reportable concentration. These compounds were acenaphthene, acetone, n-butyl alcohol, p,p’-DDT, methyl ethyl ketone, nitrobenzene, o nitrophenol, pyridine, and toluene. Of the detectable compounds, only acenaphthene, acetone, o nitrophenol, and pyridine were above wastewater standards (40 CFR 268.48 - Universal Treatment Standards). None of the organic compounds exceeded the non-wastewater standards (40 CFR 268.48 - Universal Treatment Standards). Analysis of the TCLP leachates from the Cast Stone waste forms indicated that none of the analytes exceeded the Universal Treatment Standard and, in general, all were well below the standards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗