Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Rules of Peak Multiplicity and Peak Alignment in Multiexcitonic Spectra of (In,Ga)As Quantum Dots

A simple model - the single-configuration perturbation theory - has traditionally been used to explain the main features of the multiexcitonic spectra of quantum dots, where an electron and a hole recombine in the presence of other N{sub e}-1 electrons and N{sub h}-1 holes. The model predicts the (N{sub h},N{sub e}) values for which such spectra consist of a single line or multiple lines and whether singlet lines of different (N{sub h},N{sub e}) values are energetically aligned. Here we use a nonperturbative, correlated approach that shows when such simple rules work and when they fail, thereby establishing a basis for the appropriate use of such rules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flavor symmetry breaking and vacuum alignment on orbifolds

Flavor symmetry has been widely studied for figuring out the masses and mixing angles of standard model fermions. In this paper we present a framework for handling flavor symmetry breaking where the symmetry breaking is triggered by boundary conditions of scalar fields in extra-dimensional space. The alignment of scalar expectation values is achieved without referring to any details of scalar potential and its minimization procedure. As applications to non-Abelian discrete flavor symmetries, illustrative lepton mass models are constructed where the S{sub 3} and A{sub 4} flavor symmetries are broken down to the directions leading to the tribimaximal form of lepton mixing and realistic mass patterns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Alignment of sample position and rotation during in situ synchrotron X-ray micro-diffraction experiments using a Laue cross-correlation approach

Laue micro-diffraction has proven to be able to reveal material properties at the sub-grain scale for many polycrystalline materials and is now routinely available at several synchrotron facilities, providing an approach for nondestructive three-dimensional probing of the microstructures and mechanical states of materials. However, for in situ experiments, maintaining the positioning of the sample throughout the experiment, to achieve a good alignment of the characterized volumes, is a challenging issue. The aim of the present work is to address this problem by developing an approach based on digital image correlation of focused-beam Laue diffraction patterns. The method uses small changes in the diffraction signal as a focused X-ray beam is scanned over a surface region to allow corrections to be made for both sample lateral movement and rotation. The method is demonstrated using a tensile deformation experiment on an Al sample with 2.5 µm average grain size. The results demonstrate an accuracy of 0.5 µm for sample position registration and a precision in sample rotation of ~0.01°. Finally, the proposed method is fast to implement and does not require the use of additional surface markers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

A Multithreaded Algorithm for Network Alignment Via Approximate Matching

Network alignment is an optimization problem to find the best one-to-one map between the vertices of a pair of graphs that overlaps in as many edges as possible. It is a relaxation of the graph isomorphism problem and is closely related to the subgraph isomorphism problem. The best current approaches are entirely heuristic, and are iterative in nature. They generate real-valued heuristic approximations that must be rounded to find integer solutions. This rounding requires solving a bipartite maximum weight matching problem at each step in order to avoid missing high quality solutions. We investigate substituting a parallel, half-approximation for maximum weight matching instead of an exact computation. Our experiments show that the resulting difference in solution quality is negligible. We demonstrate almost a 20-fold speedup using 40 threads on an 8 processor Intel Xeon E7-8870 system (from 10 minutes to 36 seconds).

network alignment, matching, multicore↗

Intrinsic Performance Variability in Aligned Array CNFETs

Here, the I-V characteristic of carbon nanotube (CNT) transistors is dictated by the Schottky barrier (SB) at metal-nanotube interface. The SB is defined by the diameter of the CNT along with the source/drain metal and is presumed a device constant for single CNT transistors. Given the wide distribution of diameter of CVD-grown nanotubes, the presumption of single SB, however, is inappropriate for transistors with aligned array of CNTs. Indeed, array transistors with similar geometries and contact material can still exhibit considerable variation in threshold voltage (V T ), on current (I ON ), and device resistance (R d ). We use measured diameter distribution within the framework of detailed numerical simulations to demonstrate that the diameter distribution of CNTs (in CNT FETs) plays a dominant role in defining the fluctuation of array transistors. Besides, it is argued that the large-scale integration of these devices within an IC would be feasible only if the distribution of diameter is considerably narrowed.

42 ENGINEERING↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Effects of oxygen on low-temperature growth and band alignment of ZnO/GaN heterostructures

Continuous ZnO thin films have been grown at low temperature (400 deg. C) on GaN/c-sapphire substrates in a radio-frequency magnetron-sputtering chamber employing a substoichiometric ZnO target with and without extra oxygen feeding. The effects of oxygen on the growth and band alignment of the ZnO/GaN heterostructures were investigated by using scanning-electron microscopy, x-ray diffraction, photoluminescence and transmittance/absorbance, ultraviolet-resonant Raman scattering, and x-ray photoelectron spectroscopy. Very remarkable changes of the structural and optical properties resulted from the introduction of oxygen: the surface hexahedral facets were diminished; the size of the surface islands and, hence, the compressive strains were reduced; ultraviolet transparency of the ZnO film was enhanced, together with an increased band gap due to the reduced intrinsic shallow-donor defects; and hence, the free-electron concentration. The offset in valence bands of the ZnO/GaN heterostructure was increased by {approx}90 meV at certain conditions. This is likely due to the increased Ga-O bonds at the ZnO/GaN interface by the incorporation of extra oxygen at the initial growth of ZnO.

36 MATERIALS SCIENCE↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Ridge effect and alignment phenomenon

It is assumed that the ridge effect observed by the CMS Collaboration in proton-proton collisions at the LHC and the phenomenon observed by the Pamir Collaboration in emulsion experiments with cosmic rays and characterized by the alignment of spots on a film is a manifestation of the same as-yet-unknown mechanism of the emergence of a coplanar structure of events. A large coplanar effect at the LHC in the region of forward rapidities is predicted on the basis of this hypothesis and an analysis of experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Protein Functional Surfaces: Global Shape Matching and Local Spatial Alignments of Ligand Binding Sites

Background: Protein surfaces comprise only a fraction of the total residues but are the most conserved functional features of proteins. Surfaces performing identical functions are found in proteins absent of any sequence or fold similarity. While biochemical activity can be attributed to a few key residues, the broader surrounding environment plays an equally important role. Results: We describe a methodology that attempts to optimize two components, global shape and local physicochemical texture, for evaluating the similarity between a pair of surfaces. Surface shape similarity is assessed using a three-dimensional object recognition algorithm and physicochemical texture similarity is assessed through a spatial alignment of conserved residues between the surfaces. The comparisons are used in tandem to efficiently search the Global Protein Surface Survey (GPSS), a library of annotated surfaces derived from structures in the PDB, for studying evolutionary relationships and uncovering novel similarities between proteins. Conclusion: We provide an assessment of our method using library retrieval experiments for identifying functionally homologous surfaces binding different ligands, functionally diverse surfaces binding the same ligand, and binding surfaces of ubiquitous and conformationally flexible ligands. Results using surface similarity to predict function for proteins of unknown function are reported. Additionally, an automated analysis of the ATP binding surface landscape is presented to provide insight into the correlation between surface similarity and function for structures in the PDB and for the subset of protein kinases.

59 BASIC BIOLOGICAL SCIENCES↗

MiNAA: Microbiome Network Alignment Algorithm

A microbial network is a mathematical representation of a microbial community where nodes represent microbes and edges represent interactions. It is well-recognized that microbes are among the main drivers of biological phenotypes in soil, plants, and animals alike, and thus, their study has vast implications for soil, plant and human health. In particular, recognizing the microbial, environmental, and agricultural factors that drive plant and soil phenotypes is crucial to comprehend processes connected to plant and soil health, to identify global practices of sustainable agriculture, as well as to predict plant and soil responses to environmental perturbations such as climate change. The adaptability of microbes to thrive in every environment poses challenges for scientists who try to understand their communities. Indeed, two microbial communities with the exact same players can interact differently depending on the environmental conditions. It is thus desirable to identify commonalities and differences on two microbial networks, hence the need for computational tools that can match (or align) them.

97 MATHEMATICS AND COMPUTING↗

Alignment of leading-edge and peak-picking time of arrival methods to obtain accurate source locations

The location of a radiating source can be determined by time-tagging the arrival of the radiated signal at a network of spatially distributed sensors. The accuracy of this approach depends strongly on the particular time-tagging algorithm employed at each of the sensors. If different techniques are used across the network, then the time tags must be referenced to a common fiducial for maximum location accuracy. In this report we derive the time corrections needed to temporally align leading-edge, time-tagging techniques with peak-picking algorithms. We focus on broadband radio frequency (RF) sources, an ionospheric propagation channel, and narrowband receivers, but the final results can be generalized to apply to any source, propagation environment, and sensor. Our analytic results are checked against numerical simulations for a number of representative cases and agree with the specific leading-edge algorithm studied independently by Kim and Eng (1995) and Pongratz (2005 and 2007).

97 MATHEMATICS AND COMPUTING↗

An efficient and broadly applicable method for transient transformation of plants using vertically aligned carbon nanofiber arrays

Transient transformation in plants is a useful process for evaluating gene function. However, there is a scarcity of minimally perturbing methods for gene delivery that can be used on multiple organs, plant species, and non-excised tissues. We pioneered and demonstrated the use of vertically aligned carbon nanofiber (VACNF) arrays to efficiently perform transient transformation of different tissues with DNA constructs in multiple plant species. The VACNFs permeabilize plant tissue transiently to allow molecules into cells without causing a detectable stress response. We successfully delivered DNA into leaves, roots and fruit of five plant species (Arabidopsis, poplar, lettuce, Nicotiana benthamiana , and tomato) and confirmed accumulation of the encoded fluorescent proteins by confocal microscopy. Using this system, it is possible to transiently transform plant cells with both small and large plasmids. The method is successful for species recalcitrant to Agrobacterium -mediated transformation. VACNFs provide simple, reliable means of DNA delivery into a variety of plant organs and species.

59 BASIC BIOLOGICAL SCIENCES↗

Recent Advances in Vertically Aligned Nanocomposites with Tunable Optical Anisotropy: Fundamentals and Beyond

Developing reliable and tunable metamaterials is fundamental to next-generation optical-based nanodevices and computing schemes. In this review, an overview of recent progress made with a unique group of ceramic-based functional nanocomposites, i.e., vertically aligned nanocomposites (VANs), is presented, with the focus on the tunable anisotropic optical properties. Using a self-assembling bottom-up deposition method, the as-grown VANs present great promise in terms of structural flexibility and property tunability. Such broad tunability of functionalities is achieved through VAN designs, material selection, growth control, and strain coupling. The as-grown multi-phase VAN films also present enormous advantages, including wafer scale integration, epitaxial quality, sharp atomic interface, as well as designable materials and geometries. This review also covers the research directions with practical device potentials, such as multiplex sensing, high-temperature plasmonics, magneto-optical switching, as well as photonic circuits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertically Aligned Single-Crystalline CoFe 2 O 4 Nanobrush Architectures with High Magnetization and Tailored Magnetic Anisotropy

Micrometer-tall vertically aligned single-crystalline CoFe 2 O 4 nanobrush architectures with extraordinarily large aspect ratio have been achieved by the precise control of a kinetic and thermodynamic non-equilibrium pulsed laser epitaxy process. Direct observations by scanning transmission electron microscopy reveal that the nanobrush crystal is mostly defect-free by nature, and epitaxially connected to the substrate through a continuous 2D interface layer. In contrast, periodic dislocations and lattice defects such as anti-phase boundaries and twin boundaries are frequently observed in the 2D interface layer, suggesting that interface misfit strain relaxation under a non-equilibrium growth condition plays a critical role in the self-assembly of such artificial architectures. Further, magnetic property measurements have found that the nanobrushes exhibit a saturation magnetization value of 6.16 μB/f.u., which is much higher than the bulk value. The discovery not only enables insights into an effective route for fabricating unconventional high-quality nanostructures, but also demonstrates a novel magnetic architecture with potential applications in nanomagnetic devices.

36 MATERIALS SCIENCE↗