Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Dynamic posture analysis of Spacelab-1 crew members

Dynamic posture testing was conducted on the science crew of the Spacelab-1 mission on a single axis linear motion platform. Tests took place in pre- and post-flight sessions lasting approximately 20 min each. The pre-flight tests were widely spaced over the several months prior to the mission while the post-flight tests were conducted over the first, second, fourth, and sixth days after landing. Two of the crew members were also tested on the day of landing. Consistent with previous postural testing conducted on flight crews, these crew members were able to complete simple postural tasks to an acceptable level even in the first few hours after landing. Our tests were designed to induce dynamic postural responses using a variety of stimuli and from these responses, evaluate subtle changes in the postural control system which had occurred over the duration of the flight. Periodic sampling post-flight allowed us to observe the time course of readaptation to terrestrial life. Our observations of hip and shoulder position, when subjected to careful analysis, indicated modification of the postural response from pre- to post-flight and that demonstrable adjustments in the dynamic control of their postural systems were taking place in the first few days after flight. For transient stimuli where the platform on which they were asked to stand quickly moved a few centimeters fore or aft then stopped, ballistic or open loop 'programs' would closely characterize the response. During these responses the desired target position was not always achieved and of equal importance not always properly corrected some 15 seconds after the platform ceased to move. The persistent observation was that the subjects had a much stronger dependence on visual stabilization post-flight than pre-flight. This was best illustrated by a slow or only partial recovery to an upward posture after a transient base-of-support movement with eyes open. Postural responses to persistent wideband pseudorandom base-of-support translation were modeled as time invarient linear systems arrived at by Kalman adaptive filter techniques. Derived model parameters such as damping factor and fundamental frequency of the closed loop system showed significant modification between pre- and post-flight. This phenomenon is best characterized by movement of the poles toward increasing stability. While pre-flight data tended to show shoulders and hips moving in phase with each other, post-flight data showed a more disjoint behavior.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Electrocapturing flow cell

A flow cell for electrophoretically-assisted capturing analytes from a flow. The flow cell includes a specimen chamber, a first membrane, a second membrane, a first electrode chamber, and a second electrode chamber. The specimen chamber may have a sample inlet and a sample outlet. A first portion of the first membrane may be coupled to a first portion of the specimen chamber. A first portion of the second membrane may be coupled to a second portion of the specimen chamber. The first electrode chamber may be configured to accept a charge. A portion of the first electrode chamber may be coupled to a second portion of the first membrane. A second electrode chamber may be configured to accept an opposite charge. A portion of the second electrode chamber may be coupled to a second portion of the second membrane.

47 OTHER INSTRUMENTATION↗

Performance of a Light-Weight Ablative Thermal Protection Material for the Stardust Mission Sample Return Capsule

New tests and analyses are reported that were carried out to resolve testing uncertainties in the original development and qualification of a lightweight ablative material used for the Stardust spacecraft forebody heat shield. These additional arcjet tests and analyses confirmed the ablative and thermal performance of low density Phenolic Impregnated Carbon Ablator (PICA) material used for the Stardust design. Testing was done under conditions that simulate the peak convective heating conditions (1200 W/cm2 and 0.5 atm) expected during Earth entry of the Stardust Sample Return Capsule. Test data and predictions from an ablative material response computer code for the in-depth temperatures were compared to guide iterative adjustment of material thermophysical properties used in the code so that the measured and predicted temperatures agreed. The PICA recession rates and maximum internal temperatures were satisfactorily predicted by the computer code with the revised properties. Predicted recession rates were also in acceptable agreement with measured rates for heating conditions 37% greater than the nominal peak heating rate of 1200 W/sq cm. The measured in-depth temperature response data show consistent temperature rise deviations that may be caused by an undocumented endothermic process within the PICA material that is not accurately modeled by the computer code. Predictions of the Stardust heat shield performance based on the present evaluation provide evidence that the maximum adhesive bondline temperature will be much lower than the maximum allowable of 250 C and an earlier design prediction. The re-evaluation also suggests that even with a 25 percent increase in peak heating rates, the total recession of the heat shield would be a small fraction of the as-designed thickness. These results give confidence in the Stardust heat shield design and confirm the potential of PICA material for use in new planetary probe and sample return applications.

Covington, M. A.↗

CHAOS I. Direct chemical abundances for H II regions in NGC 628

The CHemical Abundances of Spirals (CHAOS) project leverages the combined power of the Large Binocular Telescope (LBT) with the broad spectral range and sensitivity of the Multi Object Double Spectrograph (MODS) to measure “direct” abundances (based on observations of the temperature-sensitive auroral lines) in large samples of H ii regions in spiral galaxies. We present LBT MODS observations of 62 H ii regions in the nearby spiral galaxy NGC 628, with an unprecedentedly large number of auroral lines measurements (18 [O iii] λ4363, 29 [N ii] λ5755, 40 [S iii]λ6312, and 40 [O ii] λλ7320, 7330 detections) in 45 H ii regions. Comparing derived temperatures from multiple auroral line measurements, we find: (1) a strong correlation between temperatures based on [S iii] λ6312 and [N ii] λ5755; and (2) large discrepancies for some temperatures based on [O ii] λλ7320, 7330 and [O iii] λ4363. Both of these trends are consistent with other observations in the literature, yet, given the widespread use and acceptance of [O iii] λ4363 as a temperature determinant, the magnitude of the T[O iii] discrepancies still came as a surprise. Based on these results, we conduct a uniform abundance analysis prioritizing the temperatures derived from [S iii] λ6312 and [N ii] λ5755, and report the gas-phase abundance gradients for NGC 628. Relative abundances of S/O, Ne/O, and Ar/O are constant across the galaxy, consistent with no systematic change in the upper IMF over the sampled range in metallicity. These alpha-element ratios, along with N/O, all show small dispersions (σ ∼ 0.1 dex) over 70% of the azimuthally averaged radius. We interpret these results as an indication that, at a given radius, the interstellar medium in NGC 628 is chemically well-mixed. Unlike the gradients in the nearly temperature-independent relative abundances, O/H abundances have a larger intrinsic dispersion of ∼0.165 dex. We posit that this dispersion represents an upper limit to the true dispersion in O/H at a given radius and that some of that dispersion is due to systematic uncertainties arising from temperature measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparing probabilistic and descriptive analyses of time–dose–toxicity relationship for determining no-observed-adverse-effect level in drug development

The no-observed-adverse-effect level (NOAEL) of a drug defined from animal studies is important for inferring a maximal safe dose in human. However, several issues are associated with its concept, determination and application. It is confined to the actual doses used in the study; becomes lower with increasing sample size or dose levels; and reflects the risk level seen in the experiment rather than what may be relevant for human. We explored a pharmacometric approach in an attempt to address these issues. We first used simulation to examine the behaviour of the NOAEL values as determined by current common practice; and then fitted the probability of toxicity as a function of treatment duration and dose to data collected from all applicable toxicology studies of a test compound. Our investigation was in the context of an irreversible toxicity that is detected at the end of the study. Simulations illustrated NOAEL's dependency on experimental factors such as dose and sample size, as well as the underlying uncertainty. Modelling the probability as a continuous function of treatment duration and dose simultaneously to data from multiple studies allowed the estimation of the dose, along with its confidence interval, for a maximal risk level that might be deemed as acceptable for human. The model-based data integration also reconciled between-study inconsistency and explicitly provided maximised estimation confidence. Such alternative NOAEL determination method should be explored for its more efficient data use, more quantifiable insight to toxic doses, and the potential for more relevant animal-to-human translation. - Highlights: • Simulations revealed issues with NOAEL concept, determination and application. • Probabilistic modelling was used to address these issues. • The model integrated time-dose-toxicity data from multiple studies. • The approach uses data efficiently and may allow more meaningful human translation.

60 APPLIED LIFE SCIENCES↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Some challenging points in the identification of defects in floating-zone n-type silicon irradiated with 8 and 15 MeV protons

Electrical properties of defects formed in n-Si(FZ) following 8 and 15 MeV proton irradiation are investigated by Hall effect measurements over the wide temperature range of T ≈ 25 to 300 K. Close attention is paid to the damaging factor of proton irradiation, leaving aside passivation effects by hydrogen. The concept of defect production and annealing processes being accepted in the literature so far needs to be reconsidered. Contrary to expectations the dominant impurity-related defects produced by MeV protons turn out to be electrically neutral in n-type material. Surprisingly, radiation acceptors appear to play a minor role. Annealing studies of irradiated samples of such complex defects as a divacancy tied to a phosphorus atom and a vacancy tied to two phosphorus atoms. The latter defect features high thermal stability. Identification of the dominant neutral donors, however, remains unclear and will require further, more detailed, studies. The electric properties of the material after proton irradiation can be completely restored at T = 800°C.

36 MATERIALS SCIENCE↗

PAVplotR

PAVplotR is an R package that accepts as input a haploid VCF and, for a user-specified bin size, calculates proportional presence-absence variation (PAV). First, all variants in the file are considered to calculate an expanded coordinate system that accounts for insertions relative to the reference sequence. Next, for each sample in the VCF, proportional PAV is summarized per bin in the expanded coordinate system and finally, PAV is plotted such that rows are samples and columns are bins with the x-axis (chromosome position) labeled according to the reference haplotype's original coordinate system.

Harder, Avril↗

Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sample results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub-Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D (Cs) ) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

H1 in RSA galaxies

The original Revised Shapley-Ames (RSA) galaxy sample of almost 1300 galaxies has been augmented with further bright galaxies from the RSA appendix as well as newer galaxy catalogs. A complete and homogeneous, strictly magnitude-limited all-sky sample of 2345 galaxies brighter than 13.4 in apparent blue magnitude was formed. New 21 cm H1 line observations for more than 600 RSA galaxies have been combined with all previously available H1 data from the literature. This new extentise data act allows detailed tests of widely accepted 'standard' reduction and analysis techniques.

Richter, OTTO-G.↗

The ROSAT spectrum of 3C 351 - A warm absorber in an X-ray-'quiet' quasar?

3C 351 is one of the most X-ray-quiet radio quasars (alpha(ox) about 1.6). We have observed 3C 351 with the ROSAT position sensitive proportional counter (PSPC) and find a complex X-ray spectrum which is not well reproduced by a power law plus low-energy cut-off model. Soft excess, partial covering, and 'warm absorber' models can all produce acceptable fits, although only the warm absorber model gives typical values for the high-energy continuum slope. The alpha(ox) measured by using quasi-simultaneous ROSAT, MMT, and HST observations is in the range 1.5-1.6, significantly above the average of 1.37 for a complete sample of 33 3CR quasars. If the soft excess or partial covering models are correct, 3C 351 appears X-ray-quiet in the PSPC band because it has an extremely steep or flat intrinsic high-energy spectral slope. However, if the warm absorber model is correct, the quasar is intrinsically X-ray-quiet; the normalization of the intrinsic (unabsorbed) X-ray emission is unusually low relative to the optical luminosity. We investigate the properties of our warm absorber model in some detail. The apparently complicated behavior of the fit parameters may be understood by considering the effects of changing absorbing column and ionization parameter on intrinsic power-law-spectra of different slopes.

Fiore, Fabrizio↗

STS 120 Return Samples: Assessment of Air Quality Aboard the Shuttle (STS-120) and International Space Station (10A)

The toxicological assessments of 2 grab sample canisters (GSCs) from the Shuttle are reported. Formaldehyde badges were not used. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 111, 82, and 78%, respectively. The Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

The Power of Many: An Ensemble Approach to Spectral Similarity

Quantifying the similarity between two mass spectra─a known reference mass spectrum and an unidentified sample mass spectrum─is at the heart of compound identification workflows in gas chromatography–mass spectrometry (GC-MS). The reference spectrum most like the sample is assigned as its identification (provided some quantitative similarity threshold is met, e.g., 80%) and thus accurately measuring similarity is essential. Significant research has gone toward developing metrics for this purpose, each of which has attempted to improve upon existing methods by incorporating GC-MS-specific information (e.g., peak ratios or retention times) or adopting various statistical and algorithmic frameworks. While this active development has led to a plethora of similarity metrics with demonstrated value across different contexts, the unfortunate consequence has been confusion surrounding which metric should be used as a global standard. No such metric is currently accepted as the standard method because different metrics have demonstrated optimal performance in different contexts. In this work, we propose an ensemble approach to spectral similarity scoring that combines the collective information from across existing similarity metrics to form an improved, globally representative similarity metric as a step toward establishing a global standard method. In conclusion, the resulting ensemble metrics are evaluated on over 88,000 spectra of varying complexity and demonstrate improved abilities to accurately rank the correct reference spectrum as the top-matching candidate for a sample relative to the rankings generated by individual similarity scores.

Carbohydrates↗

A modular approach for automated sample preparation and chemical analysis

Changes in international relations, especially within the past several years, have dramatically affected the programmatic thrusts of the U.S. Department of Energy (DOE). The DOE now is addressing the environmental cleanup required as a result of 50 years of nuclear arms research and production. One major obstacle in the remediation of these areas is the chemical determination of potentially contaminated material using currently acceptable practices. Process bottlenecks and exposure to hazardous conditions pose problems for the DOE. One proposed solution is the application of modular automated chemistry using Standard Laboratory Modules (SLM) to perform Standard Analysis Methods (SAM). The Contaminant Analysis Automation (CAA) Program has developed standards and prototype equipment that will accelerate the development of modular chemistry technology and is transferring this technology to private industry.

Clark, Michael L.↗

Uncertainty Quantification for the Reliability of the Analytical Analysis for the Simplified Model of CO2 Geological Sequestration

A hydro-mechanical model with analytical solutions including pressure evolution and geomechanical deformation for geological CO2 injection and sequestration were introduced in our previous work. However, the reliability and accuracy of the hydro-mechanical model and the companion analytical solution are uncertain because of the assumptions and simplifications in the analytical model, though it was validated by a few example cases. This study introduce the method to efficiently measure the accuracy of the analytical model, and specify the acceptable input parameters range that can guarantee the accuracy and reliability of the analytical solution. A coupled hydro-geomechanical subsurface transport simulator STOMP was adopted as a reference to justify the reliability of the hydro-mechanical model and the analytical solution. A quasi-Monte Carlo sampling method was applied to efficiently sample the input parameter space.

analytical analysis↗

Hormonal contraception alters vaginal microbiota and cytokines in South African adolescents in a randomized trial

Young women in sub-Saharan Africa are disproportionally affected by HIV infection and unintended pregnancies. However, hormonal contraceptive (HC) use may influence HIV risk through changes in genital tract microbiota and inflammatory cytokines. To investigate this, 130 HIV negative adolescent females aged 15–19 years were enrolled into a substudy of UChoose, an open-label randomized crossover study (NCT02404038), comparing acceptability and contraceptive product preference as a proxy for HIV prevention delivery methods. Participants were randomized to injectable norethisterone enanthate (Net-En), combined oral contraceptives (COC) or etonorgesterol/ethinyl estradiol combined contraceptive vaginal ring (CCVR) for 16 weeks, then crossed over to another HC for 16 weeks. Cervicovaginal samples were collected at baseline, crossover and exit for characterization of the microbiota and measurement of cytokine levels; primary endpoints were cervical T cell activation, vaginal microbial diversity and cytokine concentrations. Adolescents randomized to COCs had lower vaginal microbial diversity and relative abundance of HIV risk-associated taxa compared to Net-En or CCVR. Cervicovaginal inflammatory cytokine concentrations were significantly higher in adolescents randomized to CCVR compared to COC and Net-En. This suggests that COC use may induce an optimal vaginal ecosystem by decreasing bacterial diversity and inflammatory taxa, while CCVR use is associated with genital inflammation.

59 BASIC BIOLOGICAL SCIENCES↗

Monitoring Stock-Specific Abundance, Run Timing, and Straying of Chinook Salmon in the Columbia River Using Genetic Stock Identification (GSI)

Abstract Genetic stock identification (GSI) provides a method of characterizing stock-specific abundance, run timing, and straying as they pertain to the population demographics and behavior of both hatchery and wild fish and thus assists with fisheries management. In this study, tissues were collected and genotyped at 13 microsatellite loci from adult Chinook Salmon Oncorhynchus tshawytscha that passed Bonneville Dam during four consecutive migration years (2004–2007). GSI methods were used to estimate the proportions of stocks in a broad genetic baseline, with high-density coverage of Chinook Salmon across the eastern Pacific Rim. The estimates of abundance for interior Columbia River stocks showed widespread decline consistent with a shift to poor ocean conditions during the years when the fish in this study were at sea, but divergent stock- and age-specific patterns were also observed. For example, the upper Columbia River spring-run stock experienced a unique net gain in abundance during this period, and the interior Columbia River summer–fall-run stock experienced a delayed decline of 4-year-olds. Stocks with early run timing shifted to later migrations. However, run timing distributions did not shift unidirectionally for all stocks across years, and stock membership in three major run timing categories was maintained. Of 9,215 total adults sampled, 27 (0.3%) were out-of-basin strays and a quarter of the strays were putatively of wild origin. The general concordance of GSI results with those based on more traditional methods supports the effectiveness of GSI as a tool for fisheries management. Received May 5, 2013; accepted October 23, 2013 Published online February 10, 2014

Hess, Jon E.↗