Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Atomic recombination rate determination through heat-transfer measurement.

A theoretical and experimental demonstration is presented which shows that under suitable conditions the volume recombination coefficient can be determined by measuring the heat transfer rate into the wall of a cylinder through which a dissociated stream is passing. The experimental results obtained are in agreement with those of other investigators.

Park, C.↗

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A(3): Astrometry

Wide field measurements, namely, measurements of relative angular separations between stars over a relatively wide field for parallax and proper motion determinations, were made with the third fine guidance sensor. Narrow field measurements, i.e., double star measurements, are accomplished primarily with the area photometer or faint object camera at f/96. The wavelength range required can be met by the fine guidance sensor which has a spectral coverage from 3000 to 7500 A. The field of view of the fine guidance sensor also exceeds that required for the wide field astrometric instrument. Requirements require a filter wheel for the wide field astrometer, and so one was incorporated into the design of the fine guidance sensor. The filter wheel probably would contain two neutral density filters to extend the dynamic range of the sensor and three spectral filters for narrowing effective double star magnitude difference.

Source record↗

Vaporization of droplets in premixing chambers

Detailed measurements were made of the structures of turbulent fuel sprays vaporizing in heated airstreams. The measurements show the size dependent vaporization and dispersion of the droplets and the important influence of the large eddies in the turbulence. The measurements form a data base for the development of models of fuel spray vaporization. Two laser techniques were specially developed for the investigation. A laser tomography technique converts line-of-sight light scattering measurements into time averaged 'point' measurements of droplet size distribution and volume concentration. A laser anemometer particle sizing technique was further developed to permit accurate measurements of individual particle sizes and velocities, with backscatter collection of light. The experiments are combined with heat transfer models to analyze the performance of miniature thermocouples in liquid sprays.

Yule, A. J.↗

Atmospheric radar sounding

Monostatic and bistatic radar techniques for the measurement of the structure of volume targets in the troposphere and lower stratosphere are reviewed. The targets considered are thin turbulent layers in the lower stratosphere and rain in the troposphere. The measurements of scattering from thin turbulent layers show that layers are generally detected at or near the tropopause, and in 31 out of 34 sets of measurements, layers were detected above the tropopause in the lower 10 km of the stratosphere. The threshold for turbulent layer detection corresponds to an equivalent thickness product of ten to the minus 13th power times the cube root of m at a range of 100 km and for layers with less than 1000 m thickness. The measurement of scattering by rain shows that in the New England area both convective and widespread rain consists of a number of small cells. On average, the cells appear to have a half-intensity width of 3 to 4 km as measured with a radar system with a 1.8 km resolution cell size for cells at 100 km range.

Crane, R. K.↗

Ocean experiments and remotely sensed images of chemically dispersed oil spills

A series of experiments was performed at sea where the effectiveness of dispersants applied from a helicopter was tested on fresh and weathered crude oils released from a surface research vessel. In conjunction with these experiments, remote sensing measurements using an array of airborne optical and microwave sensors were performed in order to aid in the interpretation of the dispersant effectiveness and to obtain quantitative images of oil on the sea under controlled conditions. Surface oil thickness and volume are inferred from airborne measurements using a dual-channel microwave imaging radiometer, aerial color photography, and an airborne oceanographic lidar. The remotely sensed measurements are compared with point sampled data obtained using a research vessel. The mass balance computations of surface versus subsurface oil volume using remotely sensed and point sampled data are consistent with each other and with the volumes of oil released. Data collected by the several techniques concur in indicating that, for the oils used and under the sea conditions encountered, the dispersant and application method are primarily useful when applied to fresh oil.

Croswell, W. F.↗

Validation of measurements of ventilation-to-perfusion ratio inequality in the lung from expired gas

The analysis of the gas in a single expirate has long been used to estimate the degree of ventilation-perfusion (Va/Q) inequality in the lung. To further validate this estimate, we examined three measures of Va/Q inhomogeneity calculated from a single full exhalation in nine anesthetized mongrel dogs under control conditions and after exposure to aerosolized methacholine. These measurements were then compared with arterial blood gases and with measurements of Va/Q inhomogeneity obtained using the multiple inert gas elimination technique. The slope of the instantaneous respiratory exchange ratio (R slope) vs. expired volume was poorly correlated with independent measures, probably because of the curvilinear nature of the relationship due to continuing gas exchange. When R was converted to the intrabreath Va/Q (iV/Q), the best index was the slope of iV/Q vs. volume over phase III (iV/Q slope). This was strongly correlated with independent measures, especially those relating to inhomogeneity of perfusion. The correlations for iV/Q slope and R slope considerably improved when only the first half of phase III was considered. We conclude that a useful noninvasive measurement of Va/Q inhomogeneity can be derived from the intrabreath respiratory exchange ratio.

NASA Discipline Cardiopulmonary↗

Characterization of Infrared Optical Motion Tracking System in NASA's Simulated Lunar Operations (SLOPE) Laboratory

This work characterizes the accuracy of a 16 camera OptiTrack motion tracking system installed in NASA Glenn Research Center's Simulated Lunar Operations (SLOPE) laboratory. The position of a rigid body mounted on a motorized linear stage is compared to its position reported by the motion tracking system as it travels through the facility's 777m$^3$ capture volume of interest. Experiments show that the mean error reported by the motion tracking system for the aggregate capture volume is in-line with independent measurements collected using the motion stage. Error within regions of the capture volume exceed the mean error reported by the motion tracking system, likely due to occlusion, and suggests that additional cameras should be used to increase measurement accuracy in these regions. Overall, results show that error values reported by the motion tracking system are representative of the measurement error in a collected data set and validates the system's use for characterizing the mobility and tractive performance of robots, rovers, and other vehicles for planetary exploration.

Motion capture↗

Anthropometric changes and fluid shifts

In an effort to obtain the most comprehensive and coherent picture of changes under weightlessness, a set of measurements on Skylab 2 was initiated and at every opportunity, additional studies were added. All pertinent information from ancillary sources were gleaned and collated. On Skylab 2, the initial anthropometric studies were scheduled in conjunction with muscle study. A single set of facial photographs was made in-flight. Additional measurements were made on Skylab 3, with photographs and truncal and limb girth measurements in-flight. Prior to Skylab 4, it was felt there was considerable evidence for large and rapid fluid shifts, so a series of in-flight volume and center of mass measurements and infrared photographs were scheduled to be conducted in the Skylab 4 mission. A number of changes were properly documented for the first time, most important of which were the fluid shifts. The following description of Skylab anthropometrics address work done on Skylab 4 primarily.

Thornton, W. E.↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Peer Review of X441A Fission Gas Release Data

The purpose of this document is to demonstrate completion of the independent peer review for the fission gas release measurement of fuel pins irradiated in the Experimental Breeder Reactor-II (EBR-II) as part of the X441A experiment. The specific data reviewed includes reported plenum volume and pressure from the measurement from the fuel pins. Fraction percent of fission gas release is derived in part from these measurements but is excluded from the data reviewed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Changes in leg volume during microgravity simulation

Little published information exists regarding the magnitude and time course of cephalad fluid shift resulting from microgravity simulations. Six subjects were exposed to 150 min each at horizontal bed rest, 6-deg head-down tilt, and horizontal water immersion. Fluid shift was estimated by calculating leg volumes from eight serial girth measurements from groin to ankle before, during, and after exposure. Results were compared with data from the first 3 h of spacecraft. By the end of exposure, total leg volume for the six subjects decreased by 2.6 +/- 0.8 percent, 1.7 +/- 1.2 percent, and 4.0 +/- 1.6 percent for horizontal, head-down, and immersion, respectively. Changes had plateaued for horizontal and head-down and had slowed for immersion. Relatively more fluid was lost from the lower leg than the thigh for all three conditions, particularly head-down. During the first 3 h of spaceflight, total leg volume decreased by 8.6 percent, and relatively more fluid was lost from the thigh than the lower leg. The difference in volume changes in microgravity and simulated microgravity may be caused by the small transverse pressures still present in ground-based simulations and the extremely nonlinear compliance of tissue.

Thornton, William E.↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Thermal equation of state for zoisite: Implications for the transportation of water into the upper mantle and the high-velocity anomaly in the Farallon plate

Seismic tomography studies have revealed a high-velocity anomaly at depths between 100 km and 300 km in the Farallon plate. However, the reasons for the high-velocity anomaly continue to be debated. An analysis of the mineral proportions of eclogites exhumed from the Farallon plate shows that the average amount of zoisite in eclogite is ∼16.0 vol%. Therefore, the presence of zoisite eclogite needs to be considered to explain the high-velocity anomaly of the Farallon plate. However, the thermal equation of state and stability of zoisite have not been fully investigated under high pressure−temperature (P-T) conditions. We investigated the high-pressure and high-temperature behavior of natural zoisite utilizing synchrotron single crystal-X-ray diffraction (XRD). The results indicate that zoisite is metastable up to 24.8 GPa and 700 K. We obtained the ambient unit-cell volume V0 = 901.26(3) Å3 by synchrotron single crystal-XRD measurement. We also fitted the pressure-volume-temperature data to a high-temperature Birch-Murnaghan equation of state and obtained the zero-pressure bulk modulus K0 = 134.7(8) GPa, the temperature derivative of the bulk modulus (∂K/∂T)P = −0.011(4) GPa/K, and the thermal expansion coefficients α0V = 1.9(7) × 10−5 K−1 and α1V = 3(2) × 10−8 K−2 when the pressure derivative of bulk modulus (K′0) is fixed at 4. By incorporating the results from previous studies, we calculated the density and bulk sound velocity profiles of zoisite eclogite along the Farallon plate geotherm. Finally, we infer that zoisite could carry water to depths of ∼300 km within cold subducting slabs and that the bulk sound velocity of typical zoisite eclogite with ∼61.0 vol% omphacite, ∼23.0 vol% garnet, and ∼16.0 vol% zoisite could cause the high-velocity anomalies at depths of 100−300 km in the Farallon plate.

Geology↗

Aerogel Track Morphology: Measurement, Three Dimensional Reconstruction and Particle Location using Confocal Laser Scanning Microscopy

The Stardust spacecraft returned the first undoubted samples of cometary dust, with many grains embedded in the silica aerogel collector . Although many tracks contain one or more large terminal particles of a wide range of mineral compositions , there is also abundant material along the track walls. To help interpret the full particle size, structure and mass, both experimental simulation of impact by shots and numerical modeling of the impact process have been attempted. However, all approaches require accurate and precise measurement of impact track size parameters such as length, width and volume of specific portions. To make such measurements is not easy, especially if extensive aerogel fracturing and discoloration has occurred. In this paper we describe the application and limitations of laser confocal imagery for determination of aerogel track parameters, and for the location of particle remains.

Kearsley, A. T.↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Instrumentation Working Group Summary

The Instrumentation Working Group compiled a summary of measurement techniques applicable to gas turbine engine aerosol precursors and particulates. An assessment was made of the limits, accuracy, applicability, and technology readiness of the various techniques. Despite advances made in emissions characterization of aircraft engines, uncertainties still exist in the mechanisms by which aerosols and particulates are produced in the near-field engine exhaust. To adequately assess current understanding of the formation of sulfuric acid aerosols in the exhaust plumes of gas turbine engines, measurements are required to determine the degree and importance of sulfur oxidation in the turbine and at the engine exit. Ideally, concentrations of all sulfur species would be acquired, with emphasis on SO2 and SO3. Numerous options exist for extractive and non-extractive measurement of SO2 at the engine exit, most of which are well developed. SO2 measurements should be performed first to place an upper bound on the percentage of SO2 oxidation. If extractive and non-extractive techniques indicate that a large amount of the fuel sulfur is not detected as SO2, then efforts are needed to improve techniques for SO3 measurements. Additional work will be required to account for the fuel sulfur in the engine exhaust. Chemical Ionization Mass Spectrometry (CI-MS) measurements need to be pursued, although a careful assessment needs to be made of the sampling line impact on the extracted sample composition. Efforts should also be placed on implementing non-intrusive techniques and extending their capabilities by maximizing exhaust coverage for line-of-sight measurements, as well as development of 2-D techniques, where feasible. Recommendations were made to continue engine exit and combustor measurements of particulates. Particulate measurements should include particle size distribution, mass fraction, hydration properties, and volatile fraction. However, methods to ensure that unaltered samples are obtained need to be developed. Particulate speciation was also assigned a high priority for quantifying the fractions of carbon soot, PAH, refractory materials, metals, sulfates, and nitrates. High priority was also placed on performing a comparison of particle sizing instruments. Concern was expressed by the workshop attendees who routinely make particulate measurements about the variation in number density measured during in-flight tests by different instruments. In some cases, measurements performed by different groups of researchers during the same flight tests showed an order of magnitude variation. Second priority was assigned to measuring concentrations of odd hydrogen and oxidizing species. Since OH, HO2, H2O2, and O are extremely reactive, non-extractive measurements are recommended. A combination of absorption and fluorescence is anticipated to be effective for OH measurements in the combustor and at the engine exit. Extractive measurements of HO2 have been made in the stratosphere, where the ambient level of OH is relatively low. Use of techniques that convert HO2 to OH for combustor and engine exit measurements needs to be evaluated, since the ratio of HO2/OH may be 1% or less at both the combustor and engine exit. CI-MS might be a viable option for H2O2, subject to sampling line conversion issues. However, H2O2 is a low priority oxidizing species in the combustor and at the engine exit. Two candidates for atomic oxygen measurements are Resonance Enhanced Multi-Photon Ionization (REMPI) and Laser-Induced Fluorescence (LIF). Particulate measurement by simultaneous extractive and non-extractive techniques was given equal priority to the oxidizer measurements. Concern was expressed over the ability of typical ground test sampling lines to deliver an unaltered sample to a remotely located instrument. It was suggested that the sampling probe and line losses be checked out by attempting measurements using an optical or non-extractive technique immediately upstream of the sampling probe. This is a possible application for Laser Induced Incandescence (LII) as a check on the volume fraction of soot. Optical measurements of size distribution are not well developed for ultrafine particles less than about 20 nm in diameter, so a non-extractive technique for particulate size distribution cannot be recommended without further development. Carbon dioxide measurements need to be made to complement other extractive measurement techniques. CO2 measurements enable conversion of other species concentrations to emission indices. Carbon monoxide, which acts as a sink for oxidizing species, should be measured using non-extractive techniques. CO can be rapidly converted to CO2 in extractive probes, and a comparison between extractive and non-extractive measurements should be performed. Development of non-extractive techniques would help to assess the degree of CO conversion, and might be needed to improve the concentration measurement accuracy. Measurements of NO(x) will continue to be critical due to the role of NO and NO2 in atmospheric chemistry, and their influence on atmospheric ozone. Time-resolved measurements of temperature, velocity, and species concentrations were included on the list of desired measurement. Thermocouples are typically adequate for engine exit measurements. PIV and LDV are well established for obtaining velocity profiles. The techniques are listed in the accompanying table; are divided into extractive and non-extractive techniques. Efforts were made to include a measurement uncertainty for each technique. An assessment of the technology readiness was included.

Zaller, Michelle↗

Wind Profiles Derived from Volume Imaging Lidar Data: Enhancements to the Algorithm and Comparisons with Insitu Observations

This paper presents wind measurements made with the University of Wisconsin Volume Imaging Lidar (VIL) during Aug. 1989 as part of the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment (FIFE). Enhancements to the algorithm are described. Comparisons of these results to aircraft, balloon, and surface based wind measurements are presented. Observations of the spatial variance of aerosol backscatter are also compared to measurements of the convective boundary layer depth. Measurements are based on two-dimensional cross correlations between horizontal image planes showing the spatial distribution of aerosol scattering observed by the lidar at intervals of approximately 3 minutes. Each image plane covers an area of 500-1000 sq km and the winds calculated represent area averages.

Piironen, A. K.↗