Effect of inlet temperature on rotating stall and blade vibrations in a multistage axial-flow compressor
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The compressor case of a 13-stage axial-flow compressor was modified to incorporate air-bleed systems over the fifth and tenth rotor stages. Rotating stall-exited rotor-blade vibrations were measured in the first and second stages at 60 and 68 percent of rated speed, respectively. Either the fifth- or the tenth-stage bleeds satisfactorily eliminated the peak vibratory stresses.
Triaxial and uniaxial random vibration was applied to a typical item of aerospace equipment, and.
Abstract Not Provided
Abstract Not Provided
An unstable asynchronous vibration problem in a high pressure centrifugal compressor and the remedial actions against it are described. Asynchronous vibration of the compressor took place when the discharge pressure (Pd) was increased, after the rotor was already at full speed. The typical spectral data of the shaft vibration indicate that as the pressure Pd increases, pre-unstable vibration appears and becomes larger, and large unstable asynchronous vibration occurs suddenly (Pd = 5.49MPa). A computer program was used which calculated the logarithmic decrement and the damped natural frequency of the rotor bearing systems. The analysis of the log-decrement is concluded to be effective in preventing unstable vibration in both the design stage and remedial actions.
Discussed here is the suggested installation of the 'unbalanced' 8-cylinder VE-engine. The suggestion was that a flexible mounting be used instead of bolting the engine rigidly to the airplane structure. It was concluded that a flexible connection between the engine and the airplane is probably possible. A flexible connection primarily diminishes the vibrations due to inertia and, to a lesser degree, those due to torque variation. However, engines vibrate more when freely suspended than when rigidly mounted, and this vibration has a detrimental effect on all connections between the engine and the airplane. Therefore, in view of the relatively insignificant advantages which may be derived from the elastic suspension of the engine, the present rigid mounting is to be preferred. Vibration reduction can be achieved by incorporating in the fuselage as many of the rigid airplane parts as possible.
A computer program was developed for designing a low vibration gearbox. The code is based on a finite element shell analysis, a modal analysis, and a structural optimization method. In the finite element analysis, a triangular shell element with 18 degrees-of-freedom is used. In the optimization method, the overall vibration energy of the gearbox is used as the objective function and is minimized at the exciting frequency by varying the finite element thickness. Modal analysis is used to derive the sensitivity of the vibration energy with respect to the design variable. The sensitivity is representative of both eigenvalues and eigenvectors. The optimum value is computed by the gradient projection method and a unidimensional search procedure under the constraint condition of constant weight. The computer code is applied to a design problem derived from an experimental gearbox in use at the NASA Lewis Research Center. The top plate and two side plates of the gearbox are redesigned and the contribution of each surface to the total vibration is determined. Results show that optimization of the top plate alone is effective in reducing total gearbox vibration.
Modern automotive applications demand lightweight, multifunctional materials to reach mileage goals and natural fiber reinforced composites (NFRCs) are one of the classes of materials proposed as a solution. NFRCs exhibit good vibration damping properties and have low density, but are often limited by processing challenges, poor-fiber matrix compatibility and variable performance. Herein, we investigate non-woven wet-lay of comingled banana fiber (BF), recycled glass fiber (rGF), and polypropylene (PP) fibers to in situ sizing and preparation of composite feedstocks for compression molding. BF and rGF hybrids were prepared by stacking rGF layers during compression molding to produce composites with various fiber ratios. The effect of fiber content, in-situ sizing and ratio of BF to rGF on tensile, flexural and vibration damping performance are investigated. Key results are the significant increase in tensile strength by in situ sizing (40 % sized at 60 wt% BF) and in flexural modulus (+58 % sized at 60 wt% BF) and flexural strength (+41 % sized 60 wt% BF) compared to the unsized equivalent. For BF-rGF hybrid composites with40 wt% total fiber content, flexural strength and modulus were improved by 51 % and 231 % respectively for a 1:1 ratio BF:rGF compared to BF reinforced system. Lastly, identifying the cross-over point where damping and stiffness are optimized for a hybrid composite. These findings demonstrate that these composites can be used as alternative to synthetic fiber or mineral filled composites in automotive applications, particularly where weight reduction, vibration damping and stiffness are desired.
This study proposes an optimized frequency adjustment method that uses a micro-cantilever beam-based piezoelectric vibration generator based on a combination of added mass and capacitance. The most important concept of the proposed method is that the frequency adjustment process is divided into two steps: the first is a rough adjustment step that changes the size of the mass added at the end of cantilever to adjust the frequency in a large-scale and discontinuous manner; the second step is a continuous but short-range frequency adjustment via the adjustable added capacitance. Experimental results show that when the initial natural frequency of a micro piezoelectric vibration generator is 69.8 Hz, then this natural frequency can be adjusted to any value in the range from 54.2 Hz to 42.1 Hz using the combination of the added mass and the capacitance. This method simply and effectively matches a piezoelectric vibration generator’s natural frequency to the vibration source frequency.
Ionic liquids (ILs) are attractive media for CO 2 capture but remain limited by viscosity and cost. Blending ILs with ethylene glycol (EG) is a practical route to mitigate these constraints, yet the molecular origins of cosolvent effects and their dependence on composition are not well resolved. We combine Fourier-transform infrared (FT-IR) spectroscopy with quantum-chemical (DFT) analysis to elucidate how the IL:EG molar ratio modulates intermolecular interactions and electronic structure. Computed vibrational frequencies enable mode assignment and deconvolution of overlapping bands, revealing systematic, ratio-dependent shifts and broadenings in (i) EG O–H stretching, (ii) cation and EG C–H stretchings (imidazolium C2–H, C4–H, C5–H, methyl and ethyl groups, -CH2 of EG), (iii) anion signature modes (e.g., CN motifs), and (iv) EG C–O and C–C stretchings, consistent with the redistribution of hydrogen-bonding networks. Molecular electrostatic potential (MESP) maps quantify attenuation of extreme potential regions with increasing EG, indicating progressive screening of cation–anion electrostatic interactions. Quantum Theory of Atoms in Molecules (QTAIM) identifies emergent bond critical points between EG and the IL ions, while Reduced Density Gradient–Noncovalent Interaction (RDG–NCI) analysis differentiates strong directional hydrogen bonds from dispersive contacts across compositions. Together, these results show that EG fraction controls a switch from predominantly ion–ion to mixed ion–EG coordination, altering local polarity and polarizability that underlie the observed FT-IR trends. The framework provides composition–structure–spectrum relationships that can guide rational selection of IL:EG ratios to balance favorable molecular interactions with practical performance targets in scalable CO 2 capture systems.
A multiple shaker placement methodology is developed and tested using a topology optimization technique. Current multiple shaker placement methodology requires optimum accelerometer placement and optimum single-shaker placement techniques. The proposed methodology is tested using a finite element model of the X-59 Low Boom Flight Demonstrator aircraft. The effective independence and the driving point acceleration transfer function (DPATF) methods are used for the accelerometer placement study. In this study, four shakers are used to excite each mode more effectively during the ground vibration test; all the modes of interest thus are separated into four groups. Each shaker takes care of a separate group of modes. Grouping the modes of interest is performed utilizing topology optimization. The number of modes for each group therefore will be automatically decided during grouping. For each group of modes, perform the following two steps to determine optimal location of four shakers: 1) At each accelerometer location, compare the magnitude of DPATF values at natural frequencies, select the minimum value, and make a vector with these minimum values of the DPATF magnitudes for each group; and 2) Select the degrees of freedom corresponding to the maximum value of this vector. The objective function value is the maximum value of the vector with minimum value of the magnitude of the superposed acceleration transfer function. This objective function value is maximized by changing the modes for each group. Forty accelerometers are enough to have good correlation between mode shapes obtained from the reduced order model and the simulated ground vibration test.
NASA Ames Research Center is responsible for the development of the Space Station Biological Research Project (SSBRP) which will support non-human life sciences research on the International Space Station Alpha (ISSA). The SSBRP is designed to support both basic research to understand the effect of altered gravity fields on biological systems and applied research to investigate the effects of space flight on biological systems. The SSBRP will provide the necessary habitats to support avian and reptile eggs, cells and tissues, plants and rodents. In addition a habitat to support aquatic specimens will be provided by our international partners. Habitats will be mounted in ISSA compatible racks at u-g and will also be mounted on a 2.5 m diameter centrifuge except for the egg incubator which has an internal centrifuge. The 2.5 m centrifuge will provide artificial gravity levels over the range of 0.01 G to 2 G. The current schedule is to launch the first rack in 1999, the Life Sciences glovebox and a second rack early in 2001, a 4 habitat 2.5 in centrifuge later the same year in its own module, and to upgrade the centrifuge to 8 habitats in 2004. The rodent habitats will be derived from the Advanced Animal Habitat currently under development for the Shuttle program and will be capable of housing either rats or mice individually or in groups (6 rats/group and at least 12 mice/group). The egg incubator will be an upgraded Avian Development Facility also developed for the Shuttle program through a Small Business and Innovative Research grant. The Space Tissue Loss cell culture apparatus, developed by Walter Reed Army Institute of Research, is being considered for the cell and tissue culture habitat. The Life Sciences Glovebox is crucial to all life sciences experiments for specimen manipulation and performance of science procedures. It will provide two levels of containment between the work volume and the crew through the use of seals and negative pressure. The glovebox will accommodate use by two crew persons simultaneously and the capability for real time video down-link and data acquisition. In house testbeds and Phase B studies of the centrifuge validated the concepts of vibration isolation and autobalancing systems to meet the ISSA microgravity requirements. The vibration isolation system is effective above the centrifuge rotation frequency while the autobalancing system on the rotor removes vibration at and below the rotation rate. Torque of the Station, induced by spin-up/spindown of the centrifuge, can be minimized by controlling spin-up/spin-down rates. The SSBRP and ISSA will provide the opportunity to perform long-term, repeatable and high quality science. The long duration increments available on the Station will permit multigeneration studies of both plants and animals which have not previously been possible. The u-g habitat racks and the eight habitat centrifuge will accommodate sufficient number of specimens to permit statistically significant sampling of specimens to investigate the time course of adaptation to altered gravity environments. The centrifuge will, for the first time, permit investigators to use gravity itself as a tool to investigate fundamental processes, to investigate the intensity and duration of gravity to maintain normal structure and function, to separate the effects of u-g from other environmental factors and to examine artificial gravity as a potential countermeasure for the physical deconditioning observed during space flight.
The CN (B {sup 2}{sigma}{sup +}-X {sup 2}{sigma}{sup +}) molecular emission spectrum is used to measure both the vibrational and rotational temperatures in atmospheric pressure arc jet discharges. The vibrational and rotational temperature effects on the synthetic diatomic molecular spectra were investigated from the (v{sup '},v{sup ''})=(0,0) band to the (5,5) band. The temperatures obtained from the synthetic spectra compared with the experimental result of a low-frequency arc discharge show a vibrational temperature of (4250-5010) K and a rotational temperature of (3760-3980) K for the input power in the range of (80-280) W. As the (0,0) band is isolated from other vibrational transition bands, determination of the rotational temperature is possible based only on the (0,0) band, which simplifies the temperature measurement. From the result, it was found that the CN molecular spectrum can be used as a thermometer for atmospheric pressure plasmas containing carbon and nitrogen.
We have numerically investigated the effect of an underdamped intra-pigment vibrational mode on an exciton's quantum coherence and energy transfer efficiency. Our model describes a bacteriochlorophyll a pigment-protein dimer under the conditions at which photosynthetic energy transfer occurs. The dimer is modeled using a theoretical treatment of a vibronic exciton, and its dynamics are numerically analyzed using a non-Markovian and non-perturbative method. We examined the system's response to various values of the Huang-Rhys factor, site energy difference, reorganization energy, and reorganization energy difference. We found that the inclusion of the intra-pigment vibronic mode allows for long-lived oscillatory quantum coherences to occur. This excitonic coherence is robust against static site-energy disorder. The vibrational mode also promotes exciton transfer along the site-energy landscape thus improving the overall energy transfer efficiency.
The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.
The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.