At least 883 records · Page 49

Advanced Microbial Check Valve development

The Microbial Check Valve (MCV) is a flight qualified assembly that provides bacteriologically safe drinking water for the Space Shuttle. The 1-lb unit is basically a canister packed with an iodinated ion-exchange resin. The device is used to destroy organisms in a water stream as the water passes through it. It is equally effective for fluid flow in either direction and its primary method of disinfection is killing rather than filtering. The MCV was developed to disinfect the fuel cell water and to prevent back contamination of stored potable water on the Space Shuttle. This paper reports its potential for space applications beyond the basic Shuttle mission. Data are presented that indicate the MCV is suitable for use in advanced systems that NASA has under development for the reclamation of humidity condensate, wash water and human urine.

Colombo, G. V.↗

Elimination of a discrete frequency acoustical phenomenon associated with the Space Shuttle main engine oxidizer valve-duct system

In the development of the Space Shuttle Main Engines, various unpredictable dynamical phenomena were experienced which resulted in engine shutdown or failures, e.g., fires. One such dynamical phenomenon consisted of an acoustical buzz at 7200 Hz in the vicinity of the main oxidizer valve. The method of isolating the buzz phenomenon, identifying the mechanism, and developing a fix to eliminate the buzz is presented together with supporting data. These data, i.e., fluctuating pressure and acceleration data, were obtained from hot firing engine tests and from liquid nitrogen flow simulation tests conducted at Marshall Space Flight Center.

Schutzenhofer, L. A.↗

Use of thermocapillary migration in a controllable heat valve

In accordance with the Marangoni effect, immiscible droplets in a host fluid in which a temperature gradient exists move in the direction of increasing temperature. It is proposed that this thermocapillary migration could be used to construct a 'liquid wick' that would return the condensed vapor at the condenser end of a heat pipe back to the evaporator, thus completing the fluid circuit. The droplets would be formed by capillary pressure forcing the condensate through a perforated diaphragm whose temperature would control the droplet flux, and hence the heat flux between the two ends of the heat pipe, thus making it a controllable heat valve.

Schmid, L. A.↗

A Positive-Shutoff Fuel Valve

Pneumatically actuated ball valve utilizes continuous contact ball seat seals and dynamic delta seals in lieu of bellows to seal against low pressure leads in fuel supply lines.

Tolpen, J.↗

Kick-Free Pressure Release Valve

Release valve for smoothly venting buildup of gas pressure modified to reduce kickback of mechanism during discharge.

Killgrove, T. O.↗

Differential Pressure Helps Seal Ball Valve

Leakage suppressed despite O-ring wear. New design eliminates leakage in vacuum selector valve on Space Shuttle waste-control subsystem. Applied to improve sealing in laboratory and industrial vacuum systems and other plumbing involving switching among lines with pressure differentials of order of 1 atmosphere (0.1 MPa).

Mangialardi, J. K.↗

Optical pulse generator using liquid crystal light valve

Numerical optical computing is discussed. A design for an optical pulse generator using a Hughes Liquid crystal light valve and intended for application as an optical clock in a numerical optical computer is considered. The pulse generator is similar in concept to the familiar electronic multivibrator, having a flip-flop and delay units.

Collins, S. A., Jr.↗

Optical flip-flops and sequential logic circuits using a liquid crystal light valve

This paper is concerned with the application of optics to digital computing. A Hughes liquid crystal light valve is used as an active optical element where a weak light beam can control a strong light beam with either a positive or negative gain characteristic. With this device as the central element the ability to produce bistable states from which different types of flip-flop can be implemented is demonstrated. In this paper, some general comments are first presented on digital computing as applied to optics. This is followed by a discussion of optical implementation of various types of flip-flop. These flip-flops are then used in the design of optical equivalents to a few simple sequential circuits such as shift registers and accumulators. As a typical sequential machine, a schematic layout for an optical binary temporal integrator is presented. Finally, a suggested experimental configuration for an optical master-slave flip-flop array is given.

Fatehi, M. T.↗

Voyager 0.2-lbf thruster valve assembly short pulse test report

The short pulse width testing completed on the Voyager 0.2-lbf thruster value assemblies (T/VA's) and the disassembly and inspection of T/VA S/N 020 is reported. The purpose for performing the short pulse width testing on Voyager 0.2-lbf thruster valve assemblies (T/VA's) was to determine: (1) impulse bit versus electrical pulse width; (2) impulse bit variations versus electrical pulse width; and (3) whether the short pulses decrease thruster life.

Johnson, D. R.↗

Joule-Thomson valves for long term service in space cryocoolers

Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.

Lester, J. M.↗

Microprocessor-Based Valved Controller

New controller simpler, more precise, and lighter than predecessors. Mass-flow controller compensates for changing supply pressure and temperature such as occurs when gas-supply tank becomes depleted. By periodically updating calculation of mass-flow rate, controller determines correct new position for valve and keeps mass-flow rate nearly constant.

Norman, Arnold M., Jr.↗

Redundant Control for Air-Circulation Valves

Four computers that control airflow to "X-wing" helicopter rotor arranged in redundant configuration. Ensures circulation control of rotor continues to function even if two of computers fail. Rotor uses 48 valve actuators regulating distribution and quantity of air flowing from leading and trailing edges.

Johnson, R., Jr.↗

Flow Analysis of Space Shuttle Feed Line 17-inch Disconnect Valve

A steady incompressible three-dimensional viscous flow analysis has been conducted for the Space Shuttle External Tank/Orbiter propellant feed line disconnect flapper valves with upstream elbows. The full Navier-Stokes code, INS3D, is modified to handle interior obstacles. Grids are generated by SVTGD3D code. Two dimensional initial grids in the flow cross section with and without the flappers are improved by elliptic smoothing to provide better orthogonality, clustering and smoothness to the three dimensional grid. The flow solver is tested for stability and convergence in the presence of interior flappers. An under-relaxation scheme has been incorporated to improve the solution stability. Important flow characteristics such as secondary flows, recirculation, vortex and wake regions, and separated flows are observed. Computed values for forces, moments, and pressure drop are in satisfactory agreement with water flow test data covering a maximum tube Reynolds number of 3.5 x 10(exp 6). The results will serve as a guide to improved design and enhanced testing of the disconnect.

Kandula, Max↗

Pressure drop and temperature rise in He II flow in round tubes, Venturi flowmeters and valves

Pressure drops in highly turbulent He II flow were measured in round tubes, valves, and Venturi flowmeters. Results are in good agreement with single-phase flow correlations for classical fluids. The temperature rise in flow in a round tube was measured, and found to agree well with predictions for isenthalpic expansion. Cavitation was observed in the venturis under conditions of low back pressure and high flow rate. Metastable superheating of the helium at the venturi throat was observed before the helium made a transition to saturation pressure.

Walstrom, P. L.↗

Remotely-Controlled Variable-Orifice Valve

Remotely-controlled variable-orifice valve used to adjust back pressure in tests of flow of air in duct. Disk with holes rotated on fixed disk with similiar holes to adjust cross sectional area available to flow. Features include compactness and reduction of perturbation. Moved easily from one flow-test facility to another.

Hill, Olen E.↗

Real time optical edge enhancement using a Hughes liquid crystal light valve

The discovery of an edge enhancement effect in using a Hughes CdS liquid crystal light valve (LCLV) is reported. An edge-enhanced version of the input writing image can be directly obtained by operating the LCLV at a lower bias frequency and bias voltage. Experimental conditions in which this edge enhancement effect can be optimized are described. Experimental results show that the SNR of the readout image using this technique is superior to that obtained using high-pass filtering. The repeatability of this effect is confirmed by obtaining an edge enhancement result using two different Hughes LCLVs. The applicability of this effect to improve discrimination capability in optical pattern recognition is addressed. The results show that the Hughes LCLV can be used in both continuous tone and edge-enhancing modes by simply adjusting its bias conditions.

Chao, Tien-Hsin↗