Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Ultrasonic nondestructive evaluation of additively manufactured wear coatings

Here, this work pertains to the nondestructive evaluation of additively deposited coatings using ultrasound measurements. The specific objective was to evaluate using ultrasound surface wave measurements the quality of Stellite 21 coatings deposited on Inconel 718 substrates by the directed energy deposition (DED) additive manufacturing (AM) process. The surface wave speed and diffuse backscatter amplitude of the ultrasound waves were correlated with both cracking and warpage of the coating. This research is important, because, the integrity of DED-processed coatings currently requires a combination of destructive metallographic studies and X-ray computed tomography analysis, which are both expensive and time consuming. Instead of using a normal incidence configuration for the ultrasound measurements, the surface-wave approach allows the inspection of the near surface coating integrity. Three different frequencies were used to excite surface waves because each frequency has a different penetration depth. The signals obtained were used to quantify and compare the surface wave speed and surface wave-diffuse ultrasonic backscatter amplitude from five different DED-processed Stellite coated samples. Considering destructive metallurgical characterization as a reference, surface wave measurements were found to be effective for examining coating integrity. Further, the backscatter amplitude of the surface waves was correlated with the crack density and warpage. These flaws also change the stress state of the Stellite coating and consequently the surface wave propagation speed and its scattering behavior.

36 MATERIALS SCIENCE↗

Radial modes of laterally stiffened piezoelectric disc transducers for ultrasonic collimated beam generation

Here, we numerically investigate the resonance and vibration characteristics of radial modes of laterally stiffened piezoelectric disc transducers. Lateral stiffening is modeled using a spring and vibration characteristics of the piezo-disc are investigated with increasing lateral stiffness. It is found that the resonant frequency response of the radial modes follows an asymptotic behavior approaching that of a clamped disc with increasing lateral stiffness. The radial mode vibration pattern of the discs is also found to be affected by lateral stiffness. While the vibration pattern of a free disc corresponds to a Bessel function, laterally stiffened discs show edge-effects where they depart from the Bessel-like behavior. In addition, a fully clamped piezo-disc is found to have an extra side-lobe when compared to a free disc. Ultrasonic beam profiles generated from radial modes of laterally stiffened discs are numerically investigated. It is found that the free piezo-disc generates a Bessel beam that has multiple side-lobes. Increasing the lateral stiffness results in a significant reduction of side-lobes in the beam profile. This technique of generating a collimated beam with side-lobe reduction finds significant applications in imaging through concrete, drilling mud, and other highly attenuating materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasonic Velocity of Diopside Liquid at High Pressure and Temperature: Constraints on Velocity Reduction in the Upper Mantle Due to Partial Melts

Sound velocities of diopside liquid were determined at high pressures and temperatures up to 3.8 GPa and 2375 K, using the ultrasonic technique combined with synchrotron X–ray diffraction and imaging in a multianvil apparatus. Our results show that the sound velocity increases with pressure but is nearly independent of temperature. Using a Monte Carlo approach, the measured high–pressure sound velocities combined with ambient–pressure density provide tight constraints for the equation of state of diopside liquid, with a best–fit adiabatic bulk modulus (K S ) of 23.8 ± 0.4 GPa and its pressure derivative (K S ') of 7.5 ± 0.5. The calculated adiabatic temperature and density profile of diopside liquid suggest that a melt layer with diopside composition in the upper mantle would be gravitationally unstable and start to crystallize from the bottom of the layer during cooling. By comparing our results with previous acoustic measurements on silicate glasses, we demonstrate the important differences in sound velocities between silicate liquids and glasses and conclude that silicate glasses may not work as a good analog material for studying the acoustic properties of silicate liquids, as measurements on unrelaxed glasses do not capture the entropic contribution to the compressional properties of liquids. Here, we modeled velocity reductions due to partial melts in the upper mantle using our results and found that for a given velocity reduction, the deeper the low–velocity region, the larger the melt fraction is required. Using silicate glass data for such estimation would result in a significant underestimation of melt fractions at high pressures.

58 GEOSCIENCES↗

ULTRASONIC DETECTION OF SURFACE-BREAKING RAILHEAD DEFECTS

We recently presented measurements of defects on the railhead, using a novel pitch-catch ultrasonic system comprising of two electro-magnetic acoustic transducers (EMATs) generating and detecting Rayleigh waves. Current systems used on the UK rail network for detecting surface breaking defects are limited in speed (<30 mph) and accuracy (depths >5 mm). The non-contact EMAT system has the potential to operate at higher line speed, improving network inspection coverage. The current system detects signals and performs an FFT in less than 1 ms, and changes in the detected signal amplitude and frequency content are used to characterise defects. A new set of simulated defects on sections of rail have been produced, including half-face slots machined normal to the railhead surface, clusters of angled slots, and pocket defects more typical of real defects. The smallest pocket defects are difficult to detect, with changes in signal amplitude and cut-off falling close to the noise level. However, at chosen higher frequencies a drop in FFT magnitude indicates the presence of a defect, and this indicator can be logically combined with amplitude and cut-off measurements to provide a more reliable result. Preparation for testing on a rotating rail rig at high speeds is ongoing.

36 MATERIALS SCIENCE↗

Tomographic Imaging of Glass/Epoxy Composite with a Laser Based Ultrasonics Setup

The present work is an attempt to augment the classical laser-based-ultrasonics setup for tomographic imaging purposes. A Glass/epoxy composite with steel insert is the test specimen and time-of-flight data has been used for tomographic reconstruction. Multiplicative algebraic reconstruction technique is used for this limited-view experiment. The resulting image is able to bring out the strong metal features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ULTRASONIC AND RADIOGRAPHIC IMAGING OF NIOBIUM TARGET CAPSULES FOR RADIOISOTOPE PRODUCTION

In the case of proton-irradiated radioisotope production, niobium target capsules containing gallium are exposed to intense radiation, thermally induced stress, for extended periods. The structural integrity of the target capsules is of crucial importance for containing the accelerator-produced radioisotopes and target material. The capsule window should be as thin and transparent to the proton beam as possible, and preferably should not become significantly activated under proton irradiation. In addition, the material for the capsule needs to be as defect-free as possible. Niobium encapsulated gallium targets have a history of unpredictable failure under intense irradiation with 100 MeV protons. This study illustrates the utility of non-destructive testing in order to detect defects that may result in mechanical failure of the capsules during irradiation. Prior to this work, it was not known if the gallium initially wets the niobium capsule that encapsulates it, and if it does, it is not known to what degree. However, the imaging techniques used in this work show that local areas of wetting do occur. We used ultrasonic images from various lots of niobium capsule material to assess the integrity of the capsules. Digital radiography is also used to detect any voids in the gallium that will tend to cause local heating in the capsules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ULTRASONIC IMAGING USING A FLEXIBLE ARRAY: IMPROVEMENTS TO THE MAXIMUM CONTRAST AUTOFOCUS ALGORITHM

In previous work, we have presented the maximum contrast autofocus algorithm for estimating unknown imaging parameters, e.g., for imaging through complicated surfaces using a flexible ultrasonic array. This paper details recent improvements to the algorithm. The algorithm operates by maximizing the image contrast metric with respect to the imaging parameters. For a flexible array, the relative positions of the array elements are parameterized using a cubic spline function and the spline control points are estimated by iterative maximisation of the image contrast via simulated annealing. The resultant spline gives an estimate of the array geometry and the profile of the surface that it has conformed to, allowing the generation of a well-focused image. A pre-processing step is introduced to obtain an initial estimate of the array geometry, reducing the time taken for the algorithm to convergence. Experimental results are demonstrated using a flexible array prototype.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous measurement of ultrasonic longitudinal wave velocities and thicknesses of a two layered media in the absence of an interface echo

A measurement technique has been developed to extract the phase information of successive echoes for the simultaneous estimation of thicknesses and ultrasonic velocities of individual layers in a two layered media. The proposed method works in the absence of an interface echo and requires the total thickness of the sample to be known. Experiments have been carried out on two layered samples of white cast iron and gray cast iron with layer thickness variation in the range of 2-8 mm for total thickness variation in the range of 12-13 mm. Comparison with micrographs of a few samples confirmed the model predictions. The model is found to be sensitive to the total sample thickness but fairly insensitive to noise in the data.

36 MATERIALS SCIENCE↗

Note: Ultrasonic gas flowmeter based on optimized time-of-flight algorithms

A new digital signal processor based single path ultrasonic gas flowmeter is designed, constructed, and experimentally tested. To achieve high accuracy measurements, an optimized ultrasound driven method of incorporation of the amplitude modulation and the phase modulation of the transmit-receive technique is used to stimulate the transmitter. Based on the regularities among the received envelope zero-crossings, different received signal's signal-to-noise ratio situations are discriminated and optional time-of-flight algorithms are applied to take flow rate calculations. Experimental results from the dry calibration indicate that the designed flowmeter prototype can meet the zero-flow verification test requirements of the American Gas Association Report No. 9. Furthermore, the results derived from the flow calibration prove that the proposed flowmeter prototype can measure flow rate accurately in the practical experiments, and the nominal accuracies after FWME adjustment are lower than 0.8% throughout the calibration range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of waviness in wind turbine blades using air coupled ultrasonics

Waviness in glass fiber reinforced composite is of great interest in composite research, since it results in the loss of stiffness. Several NDE techniques have been used previously to detect waviness. This work is concerned with waves normal to the plies in a composite. Air-coupled ultrasonics was used to detect waviness in thick composites used in the manufacturing of wind turbine blades. Composite samples with different wave aspect ratios were studied. Different wavy samples were characterized, and a three step process was developed to make sure the technique is field implementable. This gives us a better understanding of the effect of waviness in thick composites, and how it affects the life and performance of the composite.

42 ENGINEERING↗

Ultrasonic properties of low solvus high refractory (LSHR) super alloy disk material

Measurements are made for ultrasonic linear and nonlinear properties of the powder metallurgy disk alloy LSHR material designed with a relatively low {gamma}' precipitate solvus temperature and high refractory element content. This allows versatile heat treatment processing which results in high tensile, creep and fatigue properties depending on the grain size controlled through proper selection of solution heat treatment temperatures relative to the {gamma}' precipitate solvus temperature. Sound velocity and attenuation for both longitudinal and shear modes at various frequencies from 5 to 20 MHz help to identify and quantify the size of transition zone nondestructively between the small grain ({approx}10 {mu}m) and the large grain ({approx}100 {mu}m) zones. The shear wave velocity measurements taken by aligning the transducer polarization direction parallel and perpendicular to the grain transition direction reveal some results that we do not fully understand at this time and will be the basis of future research. Similarly, measurements of the acoustic nonlinearity parameter show some variations that may originate from uncertain sources.

36 MATERIALS SCIENCE↗

Measurement of irradiation effects in precipitate hardened aluminum using nonlinear ultrasonic principles (in-situ)

Currently nuclear power plants are reaching the end of their initial design life. Yet, in order to meet the energy demands, twenty year extensions have been granted to many nuclear reactor facilities. These extensions will be ending by the year 2035, leaving a large gap in the available energy supply. In order to extend the life of these facilities it will imperative to develop techniques capable detecting damage in the aging nuclear facilities. However, the high temperature and high neutron flux environment limits the materials available for use in the nuclear reactor. Because of this limitation little NDE based inspection has been implemented in high radiation environments. Yet recent developments in the understanding of Aluminum Nitride (AlN) piezoelectric sensors high temperature and radiation dependent behavior have opened the door for in-situ experimentation. An experiment was designed to monitor the propagation of an ultrasonic wave in a precipitate hardened aluminum specimen while being subjected to radiation at the Pennsylvania State Universities Breazeale Reactor. Measurements of harmonic generation were made up to 1.85x10{sup 18} fluence with significant spectral difference between the pre-irradiated state and the post irradiated state. The connection between micro-structural material changes and harmonic measurements are addressed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a novel ultrasonic temperature probe for long-term monitoring of dry cask storage systems

With the recent cancellation of the Yucca Mountain repository and the limited availability of wet storage utilities for spent nuclear fuel (SNF), more attention has been directed toward dry cask storage systems (DCSSs) for long-term storage of SNF. Consequently, more stringent guidelines have been issued for the aging management of dry storage facilities that necessitate monitoring of the conditions of DCSSs. Continuous health monitoring of DCSSs based on temperature variations is one viable method for assessing the integrity of the system. In the present work, a novel ultrasonic temperature probe (UTP) is being tested for long-term online temperature monitoring of DCSSs. Its performance was evaluated and compared with type N thermocouple (NTC) and resistance temperature detector (RTD) using a small-scale dry storage canister mockup. Our preliminary results demonstrate that the UTP system developed at Argonne is able to achieve better than 0.8 Degree-Sign C accuracy, tested at temperatures of up to 400 Degree-Sign C. The temperature resolution is limited only by the sampling rate of the current system. The flexibility of the probe allows conforming to complex geometries thus making the sensor particularly suited to measurement scenarios where access is limited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced photocatalytic performance of ZnO-reduced graphene oxide hybrid synthesized via ultrasonic probe-assisted study

A facile ultrasonic horn-assisted reaction has been used to synthesize zinc oxide-reduced graphene oxide (ZnO-RGO) hybrids in dimethylformamide. The incorporation of graphene oxide prevents the cluster formation of ZnO nanoparticles. The photocatalytic performance in degradation of methylene blue has been investigated with ZnO and ZnO-RGO hybrids and the results show that the RGO plays an important role in the enhancement of photocatalytic performance of ZnO-RGO. A direct evidence of electron exchange between ZnO and RGO is confirmed by zeta potentials measurements, which is an established reason for photocatalytic degradation of organic dyes.

36 MATERIALS SCIENCE↗

Ultrasonic wave-based structural health monitoring embedded instrument

Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials

Capacitive Micromachined Ultrasonic Transducers (CMUTs) operating in immersion support dispersive evanescent waves due to the subwavelength periodic structure of electrostatically actuated membranes in the array. Evanescent wave characteristics also depend on the membrane resonance which is modified by the externally applied bias voltage, offering a mechanism to tune the CMUT array as an acoustic metamaterial. The dispersion and tunability characteristics are examined using a computationally efficient, mutual radiation impedance based approach to model a finite-size array and realistic parameters of variation. The simulations are verified, and tunability is demonstrated by experiments on a linear CMUT array operating in 2-12 MHz range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrasonic guided waves in eccentric annular pipes

This paper studies the feasibility of using ultrasonic guided waves to rapidly inspect tubes and pipes for possible eccentricity. While guided waves are well established in the long range inspection of structures such as pipes and plates, studies for more complex cross sections are limited and analytical solutions are often difficult to obtain. Recent developments have made the Semi Analytical Finite Element (SAFE) method widely accessible for researchers to study guided wave properties in complex structures. Here the SAFE method is used to study the effect of eccentricity on the modal structures and velocities of lower order guided wave modes in thin pipes of diameters typically of interest to the industry. Results are validated using experiments. The paper demonstrates that even a small eccentricity in the pipe can strongly affect guided wave mode structures and velocities and hence shows potential for pipe eccentricity inspection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Leaky guided waves in generic bars: Numerical prediction and experimental validation by means of ultrasonic underwater testing

Guided Ultrasonic Waves (GUWs) are used in several industrial and civil applications for the non-destructive tests and inspection of mechanical waveguides immersed in fluids. As well known, the impedance mismatch at the fluid-structure interface causes the bulk waves traveling inside the waveguide to be partially refracted in the surrounding fluid. The leakage of bulk waves involves continuous energy radiation along the propagation direction, resulting in high attenuation rates and, consequently, reduced inspection ranges. In this work, the dispersion behaviour of leaky guided waves that propagate in immersed waveguides of general cross-section is investigated. To this end, a Semi-Analytical Finite Element (SAFE) method coupled with a 2.5D Boundary Element method (BEM) is used to extract the wave dispersion equation. The proposed formulation avoids the well known limitations of analytical methods in treating complex geometries as well as those of Finite Element-based methods in representing propagation processes in unbounded domains. Numerical and experimental results are presented, in which the dispersion curves are extracted for different bars of arbitrary shape immersed in water. The results obtained in this paper can be useful for the design of testing conditions in practical applications and to tune experimental set up.

42 ENGINEERING↗