Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

The Impact of Axillary Lymph Node Surgery on Breast Skin Thickening During and After Radiation Therapy for Breast Cancer

Purpose: This prospective study was conducted to determine predictors of epidermal thickening during and after whole-breast radiation therapy (XRT) using objective measurements acquired with ultrasound. Methods and Materials: After breast-conserving surgery, 70 women received a definitive course of whole-breast XRT (50 Gy plus boost). Prior to XRT, at week 6 of XRT, and 6 weeks after XRT, patients underwent objective ultrasound measurements of epidermal thickness over the lumpectomy cavity and all 4 quadrants of the treated breast. A skin thickness ratio (STRA) was then generated normalizing for corresponding measurements taken of the untreated breast. Results: Baseline measurements indicated that 87% of patients had skin thickening in the treated versus untreated breast (mean increase, 27%; SD, 0.29) prior to XRT. The STRA increased significantly by week 6 of XRT (mean, 25%; SD, 0.46) and continued to increase significantly 6 weeks after XRT (mean, 33%; SD, 0.46) above baseline measurements (P<.001 for both time points). On multivariate analysis, breast volume (P=.003) and surgical evaluation of the axilla with full lymph node dissection (P<.05) predicted for more severe changes in the STRA 6 weeks after XRT compared with baseline. STRA measurements correlated with physician ratings of skin toxicity according to Radiation Therapy Oncology Group grading criteria. Conclusions: This is one of the first studies to objectively document that lymph node surgery affects XRT-induced skin thickening in patients with breast cancer. Surgical evaluation of the axilla with complete lymph node dissection was associated with the most severe XRT-induced skin changes after XRT completion. These results may inform future studies aimed at minimizing side effects of XRT and surgery, particularly when surgical lymph node assessments may not alter breast cancer management or outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CTAB-assisted ultrasonic synthesis, characterization and photocatalytic properties of WO{sub 3}

Highlights: • WO{sub 3} 2D nanostructures were synthesized by ultrasound method assisted with CTAB. • WO{sub 3} morphology was mainly of rectangular nanoplates with a thickness of ∼50 nm. • The highest surface area value of WO{sub 3} was obtained to lowest concentration of CTAB. • WO{sub 3} activity was attributed to morphology, surface area and the addition of CTAB. • WO{sub 3} nanoplates were able to causing almost complete mineralization of rhB and IC. - Abstract: WO{sub 3} 2D nanostructures have been prepared by ultrasound synthesis method assisted with CTAB using different molar ratios. The formation of monoclinic crystal structure of WO{sub 3} was confirmed by X-ray powder diffraction (XRD). The characterization of the WO{sub 3} samples was complemented by analysis of scanning electron microscopy (SEM), which revealed morphology mainly of rectangular nanoplates with a thickness of around 50 nm and length of 100–500 nm. Infrared spectroscopy (FT-IR) was used to confirm the elimination of the CTAB in the synthesized samples. The specific surface area was determinate by the BET method and by means of diffuse reflectance spectroscopy (DRS) it was determinate the band-gap energy (E{sub g}) of the WO{sub 3} samples. The photocatalytic activity of the WO{sub 3} oxide was evaluated in the degradation reactions of rhodamine B (rhB) and indigo carmine (IC) under Xenon lamp irradiation. The highest photocatalytic activity was observed in the samples containing low concentration of CTAB with morphology of rectangular nanoplates and with higher surface area value than commercial WO{sub 3}. Photodegradation of rhB and IC were followed by means of UV–vis absorption spectra. The mineralization degree of organic dyes by WO{sub 3} photocatalyst was determined by total organic carbon analysis (TOC) reaching percentages of mineralization of 92% for rhB and 50% for IC after 96 h of lamp irradiation.

36 MATERIALS SCIENCE↗

Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methods was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of nonlinear ultrasonic waves behavior while interacting with poor interlayer bonds in large-scale additive manufactured materials

Over the past decades, researchers have developed several nonlinear ultrasonic techniques for quality control of materials commonly used in different applications. Owing to the superior sensitivity of nonlinear ultrasound waves to small defects such as micro-cracks, their applicability in different nondestructive testing (NDT) problems has been investigated in numerous studies. These studies utilize frequency domain analysis to detect the generation of higher harmonics because of the formation of defects in the inspected medium. Frequency domain analysis based on the Fourier transform is a significant approach used in linear systems; however, it may not perform adequately on nonlinear systems. Hence, studies on nonlinear dynamics and physics consider analyzing systems' behavior in the phase-space domain. In contrast to the frequency domain analysis, which can result in information loss, analysis in the phase-space domain retains all the information regarding a system's states. Here, we investigate the nonlinearities induced by poor interlayer bonding in polymer-based additive manufactured parts in the phase-space domain. It is convenient to characterize the nonlinearity in the phase-space domain because it provides a geometrical representation of a system's states. Two types of low quality interlayer bond are considered. The first type is simulated artificially while the second type is manufactured by reducing the bond quality during the printing process. The analysis verified that the received ultrasonic signals exhibit classical nonlinear behavior in the phase-space domain while interacting with simulated poor interlayer bonds. In addition, the results showed that the behavior of ultrasonic waves is amplitude-dependent and evolves into models that have not been previously reported. Furthermore, Largest Lyapunov Exponent (LLE) is used to quantify the behavior of nonlinear ultrasonic waves while interacting with poor interlayer bonds. Using LLE, it was observed that the divergence rate of the phase-space trajectories depends on the amplitude of the excitation. This observation quantitatively proves that nonlinear behavior of ultrasound while interacting with poor interlayer bonds can be amplitude-dependent. The results of both simulated and inherent poor interlayer bond cases showed that LLE can be used as a reliable quantitative damage-sensitive feature to detect and potentially characterize weak bonds, which are difficult to detect using conventional approaches. Additionally, the reported results in the phase-space domain provide a basis for proposing a new mathematical model for ultrasonic waves interacting with poor interlayer bonds.

36 MATERIALS SCIENCE↗

Co-digestion of cattle manure with food waste and sludge to increase biogas production

Highlights: Black-Right-Pointing-Pointer Small increase in methane production was observed applying sonication pretreatment. Black-Right-Pointing-Pointer Biogas productions between 720 and 1100 mL/Lreactor day were achieved. Black-Right-Pointing-Pointer Volatile solids removal efficiencies ranged between 53% and 60%. Black-Right-Pointing-Pointer Lower methane yields were obtained when operating under thermophilic conditions. Black-Right-Pointing-Pointer Optimum OLR in lab-scale CSTR was 1.2-1.3 g VS/L day (HRT: 20 days). - Abstract: Anaerobic co-digestion strategies are needed to enhance biogas production, especially when treating certain residues such as cattle/pig manure. This paper presents a study of co-digestion of cattle manure with food waste and sewage sludge. With the aim of maximising biogas yields, a series of experiments were carried out under mesophilic and thermophilic conditions using continuously stirred-tank reactors, operating at different hydraulic residence times. Pretreatment with ultrasound was also applied to compare the results with those obtained with non-pretreated waste. Specific methane production decreases when increasing the OLR and decreasing HRT. The maximum value obtained was 603 LCH{sub 4}/kg VS{sub feed} for the co-digestion of a mixture of 70% manure, 20% food waste and 10% sewage sludge (total solid concentration around 4%) at 36 Degree-Sign C, for an OLR of 1.2 g VS/L day. Increasing the OLR to 1.5 g VS/L day led to a decrease of around 20-28% in SMP. Lower methane yields were obtained when operating at 55 Degree-Sign C. The increase in methane production when applying ultrasound to the feed mixtures does not compensate for the energy spent in this pretreatment.

09 BIOMASS FUELS↗

Ultralow Thermal Conductivity in Diamond-Like Semiconductors: Selective Scattering of Phonons from Antisite Defects

In this work, we discover anomalously low lattice thermal conductivity (<0.25 W/mK at 300 degrees C) in the Hg-containing quaternary diamond-like semiconductors within the Cu2IIBIVTe4 (IIB: Zn, Cd, Hg) (IV: Si, Ge, Sn) set of compositions. Using high-temperature X-ray diffraction, resonant ultrasound spectroscopy, and transport properties, we uncover the critical role of the antisite defects HgCu and CuHg on phonon transport within the Hg-containing systems. Despite the differences in chemistry between Hg and Cu, the high concentration of these antisite defects emerges from the energetic proximity of the kesterite and stannite cation motifs. Our phonon calculations reveal that heavier group IIB elements not only introduce low-lying optical modes, but the subsequent antisite defects also possess unusually strong point defect phonon scattering power. The scattering strength stems from the fundamentally different vibrational modes supported by the constituent elements (e.g., Hg and Cu). Despite the significant impact on the thermal properties, antisite defects do not negatively impact the mobility (>50 cm2/(Vs) at 300 degrees C) in Hg-containing systems, leading to predicted zT > 1.5 in Cu2HgGeTe4 and Cu2HgSnTe4 under optimized doping. In addition to introducing a potentially new p-type thermoelectric material, this work provides (1) a strategy to use the proximity of phase transitions to increase point defect phonon scattering, and (2) a means to quantify the power of a given point defect through inexpensive phonon calculations.

14 SOLAR ENERGY↗

Structural and microscopic relaxations in glycerol: An inelastic x-ray scattering study

The THz dynamics of liquid glycerol has been probed by inelastic x-ray scattering at different pressure spanning the 0.66-3 Kbar range. A comparison with ultrasound absorption results available in literature leads us to identify the presence of two different relaxations, a structural (slow) relaxation and a microscopic (fast) one. Although the former has been already thoroughly studied in glycerol by lower frequency spectroscopic techniques, no hints on the latter are so far available in literature. We observe that the characteristic timescale of this fast relaxation ranges in the sub-picosecond, tends to decrease with increasing the wave-vector and seems rather insensitive to pressure changes. Finally, the timescale and strength of the fast relaxation have a direct link revealing the microscopic, single particle, nature of the involved process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An exploration of the utilities of terahertz waves for the NDE of composites

We report an investigation of terahertz waves for the nondestructive evaluation of composite materials and structures. The modalities of the terahertz radiation used were time domain spectroscopy (TDS) and continuous wave (CW). The composite materials and structures investigated include both non-conducting polymeric composites and carbon fiber composites. Terahertz signals in the TDS mode resembles that of ultrasound; however, unlike ultrasound, a terahertz pulse can detect a crack hidden behind a larger crack. This was demonstrated in thick GFRP laminates containing double saw slots. In carbon composites the penetration of terahertz waves is quite limited and the detection of flaws is strongly affected by the angle between the electric field vector of the terahertz waves and the intervening fiber directions. The structures tested in this study include both solid laminates and honeycomb sandwiches. The defects and anomalies investigated by terahertz waves were foreign material inclusions, simulated disbond and delamination, mechanical impact damage, heat damage, and water or hydraulic fluid ingression. The effectiveness and limitations of terahertz radiation for the NDE of composites are discussed.

36 MATERIALS SCIENCE↗

Inspection of Nickel Alloy Welds: Results from Five Year International Program

The U.S. Nuclear Regulatory Commission established and coordinated the international Program for the Inspection of Nickel alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive examination (NDE) techniques to detect and characterize primary water stress corrosion cracking (PWSCC) in dissimilar metal welds. Round-robin results showed that a combination of conventional and phased-array ultrasound provide the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in bottom-mounted instrumentation penetrations by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field.

36 MATERIALS SCIENCE↗

Materials Issues in High Temperature Ultrasonic Transducers for Under-Sodium Viewing

Liquid sodium is used as the coolant in some fast spectrum nuclear reactors. This material is optically opaque. To facilitate operations and maintenance activities, an ultrasonic under-sodium viewing system has been developed. In the USA, the technology was successfully demonstrated in the 1970's, and, over the intervening 30+ years the capability was lost. This paper reports materials challenges encountered in developing both single-element and linear phased array 2 MHz transducers that must operate at temperatures up to 260C. The critical issues are fundamentally material selection: the ability of a transducer to be immersed into liquid sodium and function at 260C, to achieve wetting and transmission of ultrasound into the sodium, and to be able to be removed and re-used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser thermoelastic generation in metals above the melt threshold

An approach is presented for calculating thermoelastic generation of ultrasound in a metal plate exposed to nanosecond pulsed laser heating, sufficient to cause melting but not ablation. Detailed consideration is given to the spatial and temporal profiles of the laser pulse, penetration of the laser beam into the sample, the appearance and subsequent growth and then contraction of the melt pool, and the time dependent thermal conduction in the melt and surrounding solid throughout. The excitation of the ultrasound takes place during and shortly after the laser pulse and occurs predominantly within the thermal diffusion length of a micron or so beneath the surface. It is shown how, because of this, the output of the thermal simulations can be expressed as axially symmetric transient radial and normal surface force distributions. The epicentral displacement response to these force distributions is obtained by two methods, the one based on the elastodynamic Green's functions for plate geometry determined by the Cagniard generalized ray method and the other using a finite element numerical method. The two approaches are in very close agreement. Numerical simulations are reported on the epicentral displacement response of a 3.12 mm thick tungsten plate irradiated with a 4 ns pulsed laser beam with Gaussian spatial profile, at intensities below and above the melt threshold.

36 MATERIALS SCIENCE↗

Damage detection technique by measuring laser-based mechanical impedance

This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

42 ENGINEERING↗

Two-phase air-water stratified flow measurement using ultrasonic techniques

In this paper, a time resolved ultrasound system was developed for investigating two-phase air-water stratified flow. The hardware of the system includes a pulsed wave transducer, a pulser/receiver, and a digital oscilloscope. The time domain cross correlation method is used to calculate the velocity profile along ultrasonic beam. The system is able to provide velocities with spatial resolution of around 1mm and the temporal resolution of 200μs. Experiments were carried out on single phase water flow and two-phase air-water stratified flow. For single phase water flow, the flow rates from ultrasound system were compared with those from electromagnetic flow (EM) meter, which showed good agreement. Then, the experiments were conducted on two-phase air-water stratified flow and the results were given. Compared with liquid height measurement from conductance probe, it indicated that the measured velocities were explainable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-contacting transfer of elastic energy into explosive simulants for dynamic property estimation

Non-contacting acoustical methods can be used to extract various material properties of liquid or solid samples without disturbing the sample. These methods are useful even in the lab since they do not involve coupling anything to the sample, which might change its properties. A forteriori, when dealing with potentially dangerous materials, non-contacting methods may be the only safe solutions to mechanical characterization. Here, we show examples of using laser ultrasound to remotely insonify and monitor the elastic properties of several granular explosive simulants. The relatively short near-infrared laser pulse length (a few hundred nanoseconds) provides a broad-band thermoelastic source of ultrasound; we intentionally stay in the thermoelastic regime to avoid damaging the material. Then, we use a scanning laser Doppler vibrometer to measure the ultrasonic response of the sample. LDV technology is well established and very sensitive at ultrasonic frequencies; atomic level motions can be measured with modest averaging. The resulting impulse response of the explosive simulant can be analyzed to determine decay rates and wave speeds, with stiffer samples showing faster wave speeds and lower decay rates. On the other hand, at the low-frequency end of the acoustic spectrum, we use an electronically phased array to couple into a freely suspended sample's normal modes. This allows us to gently heat up the sample (3 °C in just under 5 min, as shown with a thermal IR camera). In addition to the practical interest in making the sample more chemically visible through heat, these two measurements (low-frequency resonant excitation vs high-frequency wave propagation) bracket the frequency range of acoustic non-destructive evaluation methods available.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A feasibility study of in vivo applications of single beam acoustic tweezers

Tools that are capable of manipulating micro-sized objects have been widely used in such fields as physics, chemistry, biology, and medicine. Several devices, including optical tweezers, atomic force microscope, micro-pipette aspirator, and standing surface wave type acoustic tweezers have been studied to satisfy this need. However, none of them has been demonstrated to be suitable for in vivo and clinical studies. Single beam acoustic tweezers (SBAT) is a technology that uses highly focused acoustic beam to trap particles toward the beam focus. Its feasibility was first theoretically and experimentally demonstrated by Lee and Shung several years ago. Since then, much effort has been devoted to improving this technology. At present, the tool is capable of trapping a microparticle as small as 1 μm, as well as a single red blood cell. Although in comparing to other microparticles manipulating technologies, SBAT has advantages of providing stronger trapping force and deeper penetration depth in tissues, and producing less tissue damage, its potential for in vivo applications has yet been explored. It is worth noting that ultrasound has been used as a diagnostic tool for over 50 years and no known major adverse effects have been observed at the diagnostic energy level. This paper reports the results of an initial attempt to assess the feasibility of single beam acoustic tweezers to trap microparticles in vivo inside of a blood vessel. The acoustic intensity of SBAT under the trapping conditions that were utilized was measured. The mechanical index and thermal index at the focus of acoustic beam were found to be 0.48 and 0.044, respectively, which meet the standard of commercial diagnostic ultrasound system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress towards developing neutron tolerant magnetostrictive and piezoelectric transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-speed GPU-based finite element simulations for NDT

The finite element method solved with explicit time increments is a general approach which can be applied to many ultrasound problems. It is widely used as a powerful tool within NDE for developing and testing inspection techniques, and can also be used in inversion processes. However, the solution technique is computationally intensive, requiring many calculations to be performed for each simulation, so traditionally speed has been an issue. For maximum speed, an implementation of the method, called Pogo [Huthwaite, J. Comp. Phys. 2014, doi: 10.1016/j.jcp.2013.10.017], has been developed to run on graphics cards, exploiting the highly parallelisable nature of the algorithm. Pogo typically demonstrates speed improvements of 60-90x over commercial CPU alternatives. Pogo is applied to three NDE examples, where the speed improvements are important: guided wave tomography, where a full 3D simulation must be run for each source transducer and every different defect size; scattering from rough cracks, where many simulations need to be run to build up a statistical model of the behaviour; and ultrasound propagation within coarse-grained materials where the mesh must be highly refined and many different cases run.

36 MATERIALS SCIENCE↗