Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

High-voltage space-plasma interactions measured on the PASP Plus test arrays

The Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment was developed by the Air Force's Phillips Laboratory with support from NASA's Lewis Research Center. It was launched on the Advanced Photovoltaic and Electronics EXperiments (APEX) satellite on August 3, 1994 into a 70 degree inclination, 363 km by 2550 km elliptical orbit. This orbit allows the investigation of space plasma effects on high-voltage operation (leakage current at positive voltages and arcing at negative voltages) in the perigee region. PASP Plus is testing twelve solar arrays. There are four planar Si arrays: an old standard type (used as a reference), the large-cell Space Station Freedom (SSF) array, a thin 'APSA' array, and an amorphous Si array. Next are three GaAs on Ge planar arrays and three new material planar arrays, including InP and two multijunction types. Finally, there are two concentrator arrays: a reflective-focusing Mini-Cassegrainian and a Fresnel-lens focusing Mini-Dome. PASP Plus's diagnostic sensors include: Langmuir probe to measure plasma density, an electrostatic analyzer (ESA) to measure the 30 eV to 30 KeV electron/ion spectra and determine vehicle negative potential during positive biasing, and a transient pulse monitor (TPM) to characterize the arcs that occur during the negative biasing. Through positive biasing of its test arrays, PASP Plus investigated the snapover phenomenon, which took place over the range of +100 to +300 V. It was found that array configurations where the interconnects are shielded from the space plasma (i.e., the concentrators or arrays with 'wrap-through' connectors) have lower leakage current. The concentrators exhibited negligible leakage current over the whole range up to +500 V. In the case of two similar GaAs on Ge arrays, the one with 'wrap-through' connectors had lower leakage current than the one with conventional interconnects. Through negative biasing, PASP Plus investigated the arcing rates of its test arrays. The standard Si array, with its old construction (exposed rough-surface interconnects), arced significantly over a wide voltage and plasma-density range. The other arrays arced at very low rates, mostly at voltages greater than -350 V and plasma densities near or greater than 10(exp 5)/cm(exp -3). AS expected according to theory, arcing was more prevalent when array temperatures were cold (based on biasing in eclipse).

Guidice, Donald A.↗

Thermal-Flow Code for Modeling Gas Dynamics and Heat Transfer in Space Shuttle Solid Rocket Motor Joints

A new, thermal-flow simulation code, called SFLOW. has been developed to model the gas dynamics, heat transfer, as well as O-ring and flow path erosion inside the space shuttle solid rocket motor joints by combining SINDA/Glo, a commercial thermal analyzer. and SHARPO, a general-purpose CFD code developed at Thiokol Propulsion. SHARP was modified so that friction, heat transfer, mass addition, as well as minor losses in one-dimensional flow can be taken into account. The pressure, temperature and velocity of the combustion gas in the leak paths are calculated in SHARP by solving the time-dependent Navier-Stokes equations while the heat conduction in the solid is modeled by SINDA/G. The two codes are coupled by the heat flux at the solid-gas interface. A few test cases are presented and the results from SFLOW agree very well with the exact solutions or experimental data. These cases include Fanno flow where friction is important, Rayleigh flow where heat transfer between gas and solid is important, flow with mass addition due to the erosion of the solid wall, a transient volume venting process, as well as some transient one-dimensional flows with analytical solutions. In addition, SFLOW is applied to model the RSRM nozzle joint 4 subscale hot-flow tests and the predicted pressures, temperatures (both gas and solid), and O-ring erosions agree well with the experimental data. It was also found that the heat transfer between gas and solid has a major effect on the pressures and temperatures of the fill bottles in the RSRM nozzle joint 4 configuration No. 8 test.

Wang, Qunzhen↗

Mixing and transient interface condensation of a liquid hydrogen tank

Experiments were conducted to investigate the effect of axial jet-induced mixing on the pressure reduction of a thermally stratified liquid hydrogen tank. The tank was nearly cylindrical, having a volume of about 0.144 cu m with 0.559 m in diameter and 0.711 m length. A mixer/pump unit, which had a jet nozzle outlet of 0.0221 m in diameter was located 0.178 m from the tank bottom and was installed inside the tank to generate the axial jet mixing and tank fluid circulation. Mixing tests began with the tank pressures at which the thermal stratification results in 4.9-6.2 K liquid subcooling. The mixing time and transient vapor condensation rate at the liquid-vapor interface are determined. Two mixing time correlations, based on the thermal equilibrium and pressure equilibrium, are developed and expressed as functions of system and buoyancy parameters. The limited liquid hydrogen data of the present study shows that the modified steady state condensation rate correlation may be used to predict the transient condensation rate in a mixing process if the instantaneous values of jet sub cooling and turbulence intensity at the interface are employed.

Lin, C. S.↗

Comparison of experimental rotor damping data-reduction techniques

The ability of existing data reduction techniques to determine frequency and damping from transient time-history records was evaluated. Analog data records representative of small-scale helicopter aeroelastic stability tests were analyzed. The data records were selected to provide information on the accuracy of reduced frequency and decay coefficients as a function of modal damping level, modal frequency, number of modes present in the time history record, proximity to other modes with different frequencies, steady offset in time history, and signal-to-noise ratio. The study utilized the results from each of the major U.S. helicopter manufacturers, the U.S. Army Aeroflightdynamics Directorate, and NASA Ames Research Center using their inhouse data reduction and analysis techniques. Consequently, the accuracy of different data analysis techniques and the manner in which they were implemented were also evaluated. It was found that modal frequencies can be accurately determined even in the presence of significant random and periodic noise. Identified decay coefficients do, however, show considerable variation, particularly for highly damped modes. The manner in which the data are reduced and the role of the data analyst was shown to be important. Although several different damping determination methods were used, no clear trends were evident for the observed differences between the individual analysis techniques. It is concluded that the data reduction of modal-damping characteristics from transient time histories results in a range of damping values.

Warmbrodt, William↗

Overview of Coupon Testing of an IM7/8552 Composite Required to Characterize High-Energy Impact Dynamic Material Models

As part of NASA’s Advanced Composites Project (ACP), a significant research effort was established to develop and mature analysis methods for composite materials particularly applicable to high-energy dynamic impact applications. An overall goal was to develop and advance analysis methods that can be characterized using fundamental coupon level tests. Based on this fundamental characterization, simulations at the higher levels of a building block approach can be purely predictive. The tests described in this report were performed on a unidirectional carbon fiber polymer matrix composite, IM7/8552 tape, as this material system is representative of a modern aerospace grade carbon fiber tape system. These tests were chosen to provide fundamental material characterization data for three representative progressive damage and failure analysis material models available within the LS-DYNA commercial transient dynamic finite element code for use in the simulation of the dynamic and impact response of composite materials. Two of the material models, MAT162 and MAT261, are well established material models within LS-DYNA. The third material model, MAT213, is under active development. Testing consisted primarily of ASTM-type standard tests, and the tests that were performed were consistent with the needs of all three models. Additionally, coupon level tests were performed that can be used to characterize a delamination model (e.g., cohesive zone or tie-break contact). While, the tests described in this report provide fundamental material characterization data for all three of the material models mentioned above, the data is applicable to additional material models not discussed.

Justusson, Brian P.↗

Thermal Performance of Biological Substance Systems in Vitro Under Static and Dynamic Conditions at the Cryogenic Test Laboratory, NASA Kennedy Space Center, USA

A unique research program, including a comprehensive study of thermal performance at cryogenic vacuum insulation systems, was performed at the NASA Kennedy Space Center. The main goal was to develop a new soft vacuum system (from 1 torr to 10 torr) that provides an intermediate level of performance (k-value below 4.8 mW/m-K). Liquid nitrogen boil-off methods were used to test conventional materials, novel materials, and certain combinations. The test articles included combinations of aluminum foil, fiberglass paper, polyester fabric, silica aerogel composite blanket, fumed silica, silica aerogel powder, and syntactic foam. A new LCI system was developed at the Cryogenics Test Laboratory. This system performs exceptionally well at soft vacuum levels and nearly as good as an MLI at high vacuum levels. Apparent thermal conductivities for the LCI range from 2 mW/m-K at soft vacuum to 0.1 mW/m-K at high vacuum. Several cryostats were designed, constructed, and calibrated by the Cryogenics Test Laboratory at KSC NASA as part of this research program. The cryostat test apparatus is a liquid nitrogen boil-off calorimeter system for direct measurement of the apparent thermal conductivity at a fixed vacuum level between 5 x 10(exp -5) and 760 torr. The apparatus is also used for transient measurements of temperature profiles. The development of efficient, robust cryogenic insulation systems has been a targeted area of research for a number of years. Improved methods of characterization, testing, and evaluation of complex biological substance systems for cryosurgery and cryobiology are the focus of this paper.

Augustynowicz, S. D.↗

Single Event Effects Testing of the Linfinity SG1525A Pulse Width Modulator Controller

Pulse Width Modulator (PWM) Controllers are the heart of switching power supply systems in development today. The PWMs considered here have the same integration advantages as many other controllers but it also includes the interface drivers for the follow-on power Field Effect Transistors (FET). Previous work on these types of devices looked into the required test methodologies [ 11 and the impact of radiation on the soft start and shutdown circuits of typically incorporated in the technology [2]. Taking advantage of this previous work this study was undertaken to determine the single event destructive and transient susceptibility of the Linfinity SG1525A Pulse Width Modulator Controller. The device was monitored for transient interruptions in the output signals and for destructive events induced by exposing it to a heavy ion beam at the Texas A&M University Cyclotron Single Event Effects Test Facility. After exposing these devices to the beam, a new upset mode has been identified that can lead to catastrophic power supply system failure if this event would occur while drive power FETs off the two device outputs. The devices and the test methods used will be described first. This will be followed by a brief description of the data collected to date (not all data can be presented with the length constraints of the summary) and a summary of the key results.

Howard, J. W., Jr.↗

Design, analysis, and tests of a shuttle-type heat-pipe-cooled leading edge

A one-half scale heat-pipe-cooled leading edge model was designed and fabricated to verify feasibility and performance of a full-scale Phase B shuttle orbiter design. Model performance was investigated experimentally by radiant heating and aerothermal tests and analytically by using a simple technique which predicts heat pipe start-up from the frozen state and also predicts transient and steady-state thermal behavior. Analytical results agree well with experimental results for start-up and steady-state heat pipe operation. The results indicate that variations in angle of attack and roll orientation had a negligible effect on heat pipe performance. The heat pipes effectively isothermalized the leading edge, and reduced peak temperatures to levels compatible with the use temperatures of superalloys. Results of these tests demonstrated the durability of the heat-pipe-cooled leading edge in withstanding earth-entry thermal and mechanical loads and indicate that the use of heat pipes in leading edge structures is a reliable concept for fully reusable hypersonic cruise and space transportation systems.

Camarda, C. J.↗

Identification of quasi-steady compressor characteristics from transient data

The principal goal was to demonstrate that nonlinear compressor map parameters, which govern an in-stall response, can be identified from test data using parameter identification techniques. The tasks included developing and then applying an identification procedure to data generated by NASA LeRC on a hybrid computer. Two levels of model detail were employed. First was a lumped compressor rig model; second was a simplified turbofan model. The main outputs are the tools and procedures generated to accomplish the identification.

Nunes, K. B.↗

Steady and transient performance calculation method for prediction, analysis, and identification

The detailed design and development of turbofans Involves the prediction and identification, by means of test analysis, of the performance of the engine and its components. The thermodynamic simulation and analysis codes integrate existing knowledge and Interpretations of the detailed operating procedure of the components of the engine being developed. The relevance of the predicted performance depends on the quality of the representation of the various physical phenomena affecting the characteristics of the components and, consequently, on the incorporation of experimental correlation in the modelling. In this context, the representation of compressor and turbine characteristics is particularly important. Firstly, we will analyze the ability of corrected parameters to represent MACH similitude at the component inlet under various conditions. The various measurements achieved on the engine during development are used to enhance the modelling. The methods of identifying the thermodynamic calculation code with the various measurements, considered here with their uncertainties, are then presented and described. The analysis of the tests performed on the powerplant, designed to Identify the real characteristics of the engine components, can be undertaken, considering one or more engine test points and incorporating knowledge acquired through experimentation or on the component test bench. There are many possible fields of use for these identification methods ranging from the rematching of components to the optimization of the control system.

Jean Pierre Duponchel↗

Development and Testing of a Sorbent-Based Atmosphere Revitalization System 2010/2011

Spacecraft being developed for future exploration missions incorporate Environmental Control and Life Support Systems (ECLSS) that limit weight, power, and volume thus requiring systems with higher levels of efficiency while maintaining high dependability and robustness. For air revitalization, an approach that meets those goals utilizes a regenerative Vacuum-Swing Adsorption (VSA) system that removes 100% of the CO2 from the cabin atmosphere as well as 100% of the water. A Sorbent Based Atmosphere Revitalization (SBAR) system is a VSA system that utilizes standard commercial adsorbents that have been proven effective and safe in spacecraft including Skylab and the International Space Station. The SBAR system is the subject of a development, test, and evaluation program that is being conducted at NASA s Marshall Space Flight Center. While previous testing had validated that the technology is a viable option, potential improvements to system design and operation were identified. Modifications of the full-scale SBAR test articles and adsorption cycles have been implemented and have shown significant performance gains resulting in a decrease in the consumables required for a mission as well as improved mission safety. Previous testing had utilized single bed test articles, during this period the test facility was enhanced to allow testing on the full 2-bed SBAR system. The test facility simulates a spacecraft ECLSS and allows testing of the SBAR system over the full range of operational conditions using mission simulations that assess the real-time performance of the SBAR system during scenarios that include the metabolic transients associated with extravehicular activity. Although future manned missions are currently being redefined, the atmosphere revitalization requirements for the spacecraft are expected to be quite similar to the Orion and the Altair vehicles and the SBAR test program addressed validation to the defined mission requirements as well as operation in other potential vehicle architectures. The development program, including test articles, the test facility, and tests and results through early 2011 is discussed.

Miller, Lee A.↗

Vertical axis wind turbine drive train transient dynamics

Start up of a vertical axis wind turbine causes transient torque oscillations in the drive train with peak torques which may be over two and one half times the rated torque of the turbine. A computer code, based on a lumped parameter model of the drive train, was developed and tested for the low cost 17 meter turbine; the results show excellent agreement with field data. The code was used to predict the effect of a slip clutch on transient torque oscillations. It was demonstrated that a slip clutch located between the motor and brake can reduce peak torques by thirty eight percent.

Clauss, D. B.↗

Thermal finite-element analysis of space shuttle main engine turbine blade

Finite-element, transient heat transfer analyses were performed for the first-stage blades of the space shuttle main engine (SSME) high-pressure fuel turbopump. The analyses were based on test engine data provided by Rocketdyne. Heat transfer coefficients were predicted by performing a boundary-layer analysis at steady-state conditions with the STAN5 boundary-layer code. Two different peak-temperature overshoots were evaluated for the startup transient. Cutoff transient conditions were also analyzed. A reduced gas temperature profile based on actual thermocouple data was also considered. Transient heat transfer analyses were conducted with the MARC finite-element computer code.

Abdul-Aziz, Ali↗

Characterization of the space shuttle reaction control system engine

A computer program was developed and written in FORTRAN 5 which predicts the transient and steady state performance and heat transfer characteristics of a pulsing GO2/GH2 rocket engine. This program predicts the dynamic flow and ignition characteristics which, when combined in a quasi-steady state manner with the combustion and mixing analysis program, will provide the thrust and specific impulse of the engine as a function of time. The program also predicts the transient and steady state heat transfer characteristics of the engine using various cooling concepts. The computer program, test case, and documentation are presented. The program is applicable to any system capable of utilizing the FORTRAN 4 or FORTRAN 5 language.

Wilson, M. S.↗

Experimental study of transient liquid motion in orbiting spacecraft

The results are presented of a twofold study of transient liquid motion such as that which will be experienced during orbital maneuvers by space tug. A test program was conducted in a low-g test facility involving twenty-two drops. Biaxial, low-g accelerations were applied to an instrumented, model propellant tank during free-fall testing, and forces exerted during liquid reorientation were measured and recorded. Photographic records of the liquid reorientation were also made. The test data were used to verify a mechanical analog which portrays the liquid as a point mass moving on an ellipsoidal constraint surface. The mechanical analog was coded into a FORTRAN IV digital computer program: LAMPS, Large AMPlitude Slosh. Test/analytical correlation indicates that the mechanical analog is capable of predicting the overall force trends measured during testing.

Berry, R. L.↗

Flight evaluation of modifications to a digital electronic engine control system in an F-15 airplane

The third phase of a flight evaluation of a digital electronic engine control system in an F-15 has recently been completed. It was found that digital electronic engine control software logic changes and augmentor hardware improvements resulted in significant improvements in engine operation. For intermediate to maximum power throttle transients, an increase in altitude capability of up to 8000 ft was found, and for idle to maximum transients, an increase of up to 4000 ft was found. A nozzle instability noted in earlier flight testing was investigated on a test engine at NASA Lewis Research Center, a digital electronic engine control software logic change was developed and evaluated, and no instability occurred in the Phase 3 flight evaluation. The backup control airstart modification was evaluated, and gave an improvement of airstart capability by reducing the minimum airspeed for successful airstarts by 50 to 75 knots.

Burcham, F. W., Jr.↗

Flight evaluation of modifications to a digital electronic engine control system in an F-15 airplane

The third phase of a flight evaluation of a digital electronic engine control system in an F-15 has recently been completed. It was found that digital electronic engine control software logic changes and augmentor hardware improvements resulted in significant improvements in engine operation. For intermediate to maximum power throttle transients, an increase in altitude capability of up to 8000 ft was found, and for idle to maximum transients, an increase of up to 4000 ft was found. A nozzle instability noted in earlier flight testing was investigated on a test engine at NASA Lewis Research Center, a digital electronic engine control software logic change was developed and evaluated, and no instability occurred in the Phase 3 flight evaluation. The backup control airstart modification was evaluated, and gave an improvement of airstart capability by reducing the minimum airspeed for successful airstarts by 50 to 75 knots.

Burcham, F. W., Jr.↗

Rotor response for transient unbalance changes in a nonlinear simulation

Transient unbalance shifts were determined not to excite a rotor instability in the high pressure turbomachinery of the Space Shuttle Main Engine using the current rotor dynamic models. Sudden unbalance changes of relatively small magnitudes during fast-speed ramps showed stable nonsynchronous motion depending on the resultant unbalance distribution at subsequent high speed dwells. Transient moment unbalance may initiate a limit cycle subsynchronous response that shortly decays, but a persistent subsynchronous with large amplitudes was never achieved. These limit cycle subsynchronous amplitudes appear to be minimized with lower unbalance magnitudes, which indicates improved rotor balancing would sustain synchronous motion only. The transient unbalance phenomenon was determined to be an explanation for synchronous response shifts often observed during engine tests.

Hine, M. J.↗