Recommended practice for solar simulation for thermal balance testing of spacecraft
Test requirements and instrumentation are discussed together with a review of general procedures, safety, and maintenance. A term definition listing is included.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Test requirements and instrumentation are discussed together with a review of general procedures, safety, and maintenance. A term definition listing is included.
It is proposed that the source for solar hard X-ray bursts may consist of a distribution of many small impulsively-heated kernels, each cooled by anomalous conduction, with lifetimes shorter than current burst data temporal resolution. The dynamic spectra of bursts are governed by the dynamic evolution of the kernel production process, such as magnetic-field dissipation in the tearing mode. An integral equation is formulated, the solution of which yields information on this kernel production process from dynamic burst spectra, for any kernel model.
An HPSR Stirling engine generator system featuring latent heat thermal energy storge, excellent thermal stability and self regulating, effective thermal transport at low system delta T is described. The system was supported by component technology testing of heat pipes and of thermal storage and energy transport models which define the expected performance of the system. Preliminary and detailed design efforts were completed and manufacturing of HPSR components has begun.
The receiver is a once-through monotube boiler designed for steam/electric and process steam applications at pressures up to 17.24 MPa (2500 psia) and temperatures up to 704 C (1300 F). The unit is 76.2 cm (30.0 in.) in diameter and 95.8 cm (37.7 in.) in length; it weighs 220 kg (485 lb). Its heat transfer surface, which is 45.7 cm (18 in.) in diameter by 57 cm (22.4 in.) long, is an Inconel 625, cylindrical, tube-coil assembly composed of primary and reheat sections. A test unit was successfully operated at up to 6.9 MPa (1000 psia) and 704 C (1300 F) with solar input from a 11-m-dia parabolic dish concentrator.
EUV spectra of three active region loops observed above the solar limb with the SO55 spectrometer on Skylab are analyzed. It is noted that the lengths, peak temperatures, and pressures of the loops are typical of the X-ray coronal loops to which static models have been applied. It is found that the physical parameters of the coronal loop plasma derived from EUV spectra and raster pictures are not well represented by the static models. Although the loops also contain a significant quantity of cool plasma, no physical reason is found to differentiate them from other active region loops of similar length, pressure, and temperature. Several line ratios in the loop spectrum suggest departures from ionization equilibrium caused by rapid cooling. The source of this cooling material is discussed with reference to several models of loop dynamics.
The tracking mechanism for a point-focusing concentrator may be subject to failure. If this should occur, the solar image will travel across the aperture plate, and it may also impinge on the adjacent support structure. Such an event is called 'sun walk-off'. The present investigation is concerned with the transient response of different aperture plate materials to the intense heating produced in a typical walk-off situation for parabolic dish concentrators. Receivers for two solar module systems are considered, including a high-temperature receiver that utilizes a 2-milliradian (mrad) concentrator, and a lower-temperature receiver which is coupled with a 4-mrad concentrator. It is found that during a walk-off situation the solar image travels in a straight line in the radial direction. The results obtained for a copper aperture plate were disappointing. It appears that passive metallic plates without cooling or other protective support cannot withstand the intense heating.
Solutions of the time dependent Fokker-Planck equation was found for accelerated electrons undergoing Coulomb collisions in a magnetized, fully ionized plasma. An exact solution was found for arbitrary pitch angle and energy distribution in a uniform background plasma. Then, for an inhomogeneous plasma, a solution was found for particles with small pitch angles. These solutions were used to calculate the temporal evolution of bremsstrahlung x-rays from short bursts of nonthermal electron beams, and these spectra were compared with observed high time resolution spectra of short timescale solar hard x-ray bursts. It is shown that the observed softening in time of the spectra rules out a homogeneous background and therefore the possibility of electrons being confined to the corona either because of converging magnetic field or high densities. The inhomogeneous solution was also applied to a model with constant coronal density and exponentially rising chromospheric density. The spectra are shown to be consistent with that produced by a collimated beam of electrons accelerated in the corona with certain given conditions. These conditions could be violated if large pitch angle electrons are present.
The propagation of energetic electrons through a flaring flux tube is studied in an attempt to determine how the energy of the electrons is deposited in the flux tube. One-dimensional electrostatic particle simulations are used in the present investigation. As the energetic electrons propagate into the system, a return current of ambient plasma electrons and some of the energetic electrons is drawn into the energetic electron source. It is found that, as the ambient temperature relative to the ion temperature increases above about 3, the heated return-current electrons can excite ion-sound waves.
Physical parameters obtained for a flaring solar atmosphere in an earlier paper are used here to predict time-dependent emission-line profiles and integrated intensities as a function of position for two spectral lines commonly observed during solar flares: the X-ray resonance lines of Ca XIX and Mg XI. Considerations of ionization nonequilibrium during the rise phase of the flare are addressed, and the effects on the predicted spectral-line characteristics are discussed. It is concluded that some spectroscopic diagnostics favor the nonlocal model, but other long-standing discrepancies between the numerical models and the observations remain unresolved.
Thermal control surfaces, solar arrays, and optical devices may be adversely affected by a small quantity of molecular and/or particulate contamination. What is rarely discussed is how one: (1) quantifies the level of contamination that must be maintained in order for the system to function properly, and (2) enforces contamination control to ensure compliance with requirements. This document is designed to address these specific issues and is intended to serve as a handbook on contamination control for the reader, illustrating process and methodology while providing direction to more detailed references when needed. The effects of molecular contamination on reflecting and transmitting surfaces are examined and quantified in accordance with MIL STD 1246C. The generation, transportation, and deposition of molecular contamination is reviewed and specific examples are worked to illustrate the process a design engineer can use to estimate end of life cleanliness levels required by solar arrays, thermal control surfaces, and optical surfaces. A similar process is used to describe the effect of particulate contamination as related to percent area coverage (PAC) and bi-directional reflectance distribution function (BRDF). Relationships between PAC and surface cleanliness, which include the effects of submicron sized particles, are developed and BRDF is related to specific sensor design parameters such as Point Source Transmittance (PST). The pros and cons of various methods of preventing, monitoring, and cleaning surfaces are examined and discussed.
The work carried out under this contract attempts a better understanding of whistler wave generation and associated scattering of electrons in the solar wind. This task is accomplished through simulations using a particle-in-cell code and a Vlasov code. In addition, the work is supported by the utilization of a linear kinetic dispersion solver. Previously, we have concentrated on gaining a better understanding of the linear mode properties, and have tested the simulation codes within a known parameter regime. We are now in a new phase in which we implement, execute, and analyze production simulations. This phase is projected to last over several reporting periods, with this being the second cycle. In addition, we have started to research to what extent the evolution of the pertinent instabilities is two-dimensional. We are also continuing our work on the visualization aspects of the simulation results, and on a code version that runs on single-user Alpha-processor based workstations.
Explore the source record for details and available documents.
Concentrating solar power (CSP) plants convert energy from sunlight into electricity. Generally, a heliostat field is used to reflect sunlight and concentrate it onto a receiver, which heats the receiver and/or the media flowing through it. A flow loop transports the media through the system to a heat exchanger before returning the media back to the receiver to be reheated. The heat extracted by the heat exchanger is then converted into electricity using a conventional heat engine.
The physical properties of impact features in the Solar Max main electronics box thermal blanket are consistent with hypervelocity impacts of particles in the near-earth space environment. The majority of particles are orbital debris and include spacecraft paints and bismuth-rich particles. At least 30 percent of all impact features are caused by micrometeorites, which include silicates and sulfides. Some micrometeorites survive impact with only minor shock-metamorphic effects or chemical fractionation. Currently calibration experiments are under way to relate flux to particle diameter (or mass).
Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.
Thermal control elements applicable to the solar electric propulsion stage are discussed along with thermal control concepts. Boundary conditions are defined, and a thermal analysis was conducted with special emphasis on the power processor and equipment compartment thermal control system. Conclusions and recommendations are included.
A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.
Low thermal efficiencies in solar receivers are discussed in terms of system design. It is recommended that careful attention be given to the overall thermal systems design, especially to conductive losses about the window and areas of relatively thin insulation. If the cavity design is carefully managed to insure a small, minimally reradiating aperture, the goal of a very high efficiency cavity receiver is a realistic one.