Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Re-Additization of Commercial Biodiesel Blends During Long-Term Storage

Commercial biodiesel blends representative of the U.S. market were aged following procedure ASTM D4625, Standard Test Method for Middle Distillate Fuel Storage Stability at 43°C (110°F), with periodic monitoring of fuel properties indicative of oxidation. The oxidation stability—or oxidation reserve expressed as Rancimat induction period (IP)—gradually decreased from its initial value, as expected. At a predetermined IP threshold, an antioxidant was used to restore IP to the ASTM D7467 specification minimum of 6 six hours, referred to as re-additization. At lower IP values, the amount of antioxidant required increased significantly, and the effectiveness tended to be reduced. Once IP fell to essentially zero, the acid content increased to above the allowable limit. Insoluble material was detectable after the acid number increased out of specification. Storage life was increased with re-additization relative to the as-received fuels, as evidenced by longer time to produce acids. Experience in the field may vary based on storage conditions; however, these results indicate re-additization can significantly increase the storage life of biodiesel blends when used with regular monitoring of IP and acid number. An assessment of property changes during long-term storage showed the initial IP did not predict storage behavior, although fuels above the specification minimum remained stable for greater than 12 weeks of D4625 accelerated aging (1 one year simulated).

09 BIOMASS FUELS↗

Results of the Analyses of SMECT Mercury Sample Collected During Mercury Pump (MB1) Functional Check

A pump added to remove mercury from the sump of the Slurry Mix Evaporator Condensate Tank (SMECT) in DWPF was successfully tested in 2020, resulting in a sample of contaminated mercury obtained from the Mercury Purification Process (MPP) cell. The mercury in the sump of the SMECT was present as a result of steam stripping of sludge slurry in the Sludge Receipt and Adjustment Tank (SRAT) at DWPF. A schematic of the MPP system provided by DWPF personnel is shown in Appendix A. DWPF personnel supplied the following detailed description of the Hg sampling: “The sample provided is the result of DWPF extraction of mercury by means of the Mercury Pump-Water Cart. The Mercury Pump extracted the sample from the SMECT mercury sump. The pump uses pressurized water to transfer a small amount of mercury to a leachate bucket located at the Lab Mercury cell. The mercury and water were allowed to be self separated, and mercury was gravity decanted from the leachate bucket.” DWPF personnel indicate that the leachate bucket is equipped with both a top stopcock/drain and a lower/bottom stopcock/drain from which the mercury was decanted or drained out, while the separated water layer remained above the mercury during draining. The DWPF customer requested SRNL to analyze the sample for the following: gross alpha/nonvolatile beta analysis and perform a Toxicity Characteristic Leaching Procedure (TCLP) per the Environmental Protection Agency's Test Methods for Evaluating Solid Waste: Physical/Chemical Methods, SW-846. While the TCLP was preferred, a Total Metals analysis of the eight Resource Conservation and Recovery Act (RCRA) metals was deemed acceptable.2 The analytical data collected on this mercury sample will be used in planning for sample disposition as well to start a profile for future Hg disposition of Hg collected from steam stripping.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Fidelity Tomographic Density Reconstructions [Slides]

Pressed high explosives have small density variations associated with the pressing process, from a few to sub percent depending on the material. Variations at these levels are known to have an impact on HE performance. Currently, a destructive testing method based on physical sectioning followed by immersion density measurements (slice and dice) is utilized. However, this method has poor spatial resolution limited by the the sectioning size, 1-2 cm. If possible, radiographic methods including Computed Tomography (CT) would be preferred, as they are non-destructive and have higher (less than .1 mm) spatial resolution. However, beam hardening, scattered radiation, and detector effects make density reconstructions at this level extremely challenging.

42 ENGINEERING↗

Deciphering dark matter in the Milky Way (Final Technical Report)

The goal of this research grant was to test new methods to test theories of dark matter, whether by detecting the dark matter in the Milky Way in underground experiments, or by tracing the stars in the Milky Way and beyond. This is a final technical report summarizing the research publications over the grant period.

79 ASTRONOMY AND ASTROPHYSICS↗

Safeguards-Informed Hybrid Imagery Dataset [Poster]

Deep Learning computer vision models require many thousands of properly labelled images for training, which is especially challenging for safeguards and nonproliferation, given that safeguards-relevant images are typically rare due to the sensitivity and limited availability of the technologies. Creating relevant images through real-world staging is costly and limiting in scope. Expert-labeling is expensive, time consuming, and error prone. We aim to develop a data set of both realworld and synthetic images that are relevant to the nuclear safeguards domain that can be used to support multiple data science research questions. In the process of developing this data, we aim to develop a novel workflow to validate synthetic images using machine learning explainability methods, testing among multiple computer vision algorithms, and iterative synthetic data rendering. We will deliver one million images – both real-world and synthetically rendered – of two types uranium storage and transportation containers with labelled ground truth and associated adversarial examples.

97 MATHEMATICS AND COMPUTING↗

Mersen Grade 2114: A Comparison of Tensile Strength Data

The ASTM Brazilian disc graphite strength (splitting tensile strength, σ sts ) test method (ASTM D8289) is of interest because the small-specimen geometry is compatible with that of environmental effects specimens, thus allowing for environmental effects such as irradiation, irradiation creep, or oxidation on tensile strength to be investigated. The Brazilian disc strength of Mersen grade 2114 graphite is reported and compared with strength data previously obtained using larger cylindrical ASTM dog-bone specimens.

36 MATERIALS SCIENCE↗

Additive Manufacturing Design Guidelines for Wind Industry

The purpose of this report is to equip wind industry professionals with the fundamental information needed to best leverage additive manufacturing techniques in their design and manufacturing decisions. Herein an overview of each of the seven families of additive manufacturing is provided, along with typical materials used in each process, current ranges on process speeds, materials and system costs, and examples of systems on the market today. Using the lens of large-scale additive to suit the needs of the wind industry, the processes that are well-suited to large-scale production are down selected from the seven families and additional information with design guidelines specific to each process are detailed. A companion document titled “Relevant Additive Manufacturing Materials for Wind Industry” elaborates on the specifics of relevant material properties and test methods for additive manufacturing materials.

17 WIND ENERGY↗

Performance Test Code for Determining and Reporting Annual Heat Rate and CO2 for Coal Fueled EGUs

This material is based upon work supported by the Department of Energy under Award Number DEFE0031933. The US Department of Energy (DOE) has retained the services of ASME Standards Technology LLC (ASME ST-LLC) to develop a standardized test method and calculation protocol for determining and reporting annual/long-term heat rate for coal-fueled plants electricity generating units. ASME ST-LLC has retained the services of McHale & Associates, Inc. and Licata Energy & Environmental Consultants, Inc. to provide the technical input to this study. This code applies to hydrocarbon fueled Rankine cycle power generating facilities of any size. It is intended to be used for the determination of continuous power output and heat rate of a generating facility in its operating load cycle and in its operational lineup during the reporting period.

01 COAL, LIGNITE, AND PEAT↗

International Benchmarking: A Global Perspective of Workplace Drug and Alcohol Testing

Workplace drug and alcohol testing has been widely implemented in diverse industries and is designed to detect the use of and deter the influence of legal and illegal substances that would impair the ability to perform work that has significant security and safety implications. Across the globe, patterns of drug and alcohol use and abuse and the regulations controlling drug and alcohol use vary by location (e.g., regions, countries, etc.). The prevalence of workplace drug and alcohol testing and protection of individuals’ rights in the workplace similarly tend to exhibit contextual differences. With the advancements in drug-testing technologies and the recent issuance of guidance for additional testing matrices (e.g., oral fluid, hair, etc.) by the U.S. Department of Health and Human Services, gaining a global perspective on the current state of drug and alcohol testing practices and regulations is important for leveraging such advancements to improve the effectiveness of drug and alcohol testing. The U.S. Nuclear Regulatory Commission (NRC) tasked the Pacific Northwest National Laboratory (PNNL) fitness for duty (FFD) team to conduct a benchmarking analysis of international drug and alcohol testing regulations and programs to identify similarities and differences in workplace testing programs and the basis for any differences. The benchmarking study focuses on a policy analysis and benchmarking metrics comparison among different countries and regions. The policy analysis includes the following three types of relevant international and national policies relevant to drug and alcohol testing in the nuclear industry: 1. National drug and alcohol policy 2. Workplace drug and alcohol testing 3. FFD regulations for Nuclear Power Plants The international drug and alcohol benchmarking metrics focusses on the use of blood, breath, urine, hair, and oral fluid in testing; drug and drug metabolite cutoff values; point-of-collection testing devices; roadside testing methodologies; innovations in drug testing; and the extent of availability of such data. Gaining an understanding of workplace drug and alcohol testing in other countries as well as information about new testing methods, matrices, tools, and technologies that other countries have adopted provides NRC with international comparative information regarding the technical basis for such programs and methods as it relates to the protection of worker and public health and safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Pozzolans for Replacement of Fly Ash in Grout: Literature Review for Continuous Improvement of Cement Waste Forms

The Department of Energy (DOE) is currently responsible for treating radioactive and mixed waste, performing environmental restoration, and closing contaminated tanks and facilities resulting from nuclear weapons production during the Cold War. Cementitious reagents are the most widely used materials for (1) chemically stabilizing and encapsulating radionuclides and hazardous metals and (2) solidifying radioactive wastewater. Cementitious grouts and flowable concretes are also the most widely used materials for tank and facility closures and are used extensively for physical as well as chemical stabilization in environmental restoration projects. Ambient temperature radioactive waste cementation is a widely used technology for producing waste forms for final disposal. The current practice of designing and testing waste forms is based on a mid to late 20th century technology approach (i.e., materials, characterization, and test methods) for generating parameters for risk assessments. DOE technology development is needed to address both current, long-term, and emerging issues in this area as new waste streams come online and as regulations, performance knowledge, and risk assessment methodology continue to evolve. Consequently, the use of cementation as a means of treating chemically challenging radioactive liquid waste streams and reactive debris requires an enduring effort.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation testing of AM materials [Slides]

This presentation discusses the combined irradiation testing methods, strategies, and high-level results of the Advanced Materials and Manufacturing Technologies program. Included are neutron irradiation, ion irradiation, and post-irradiation examination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 172A-1

Results of neutron dosimetry measurements in ATR for cycle 172A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

172A↗

Mersen Grade 2114: Tensile Strength from Brazilian Disc Testing

The ASTM Brazilian disc graphite strength (splitting tensile strength, σ sts ) test method (ASTM D8289) is of interest because the small-specimen geometry is compatible with that of environmental effects specimens, thus allowing for environmental effects such as irradiation, irradiation creep, or oxidation on tensile strength to be investigated. The Brazilian disc strength of Mersen grade 2114 graphite (billet 116310 slab 1) is reported and compared with strength data previously obtained using larger cylindrical ASTM dog-bone specimens and with Brazilian disc strength data obtained from billet 116310 slab 5.

36 MATERIALS SCIENCE↗

Evaluation of flame propagation of retrofit energy efficient wall assemblies

Leveraging safety science experience and industry relationships, UL Solutions and the International Association of Fire Fighters (IAFF) initiated a joint project in 2022 under an agreement with the US Department of Energy to evaluate the flame propagation of retrofit energy efficient wall assemblies. A draft of the protocol from the ASTM work was used to test and comparatively study various retrofit energy efficient designs to gain a better understanding of their fire behavior. The goals of this study were as follows: Develop an understanding of fire propagation across new, cost effective, and energy efficient exterior retrofit wall assemblies. Refine the flame propagation draft test method for exterior wall assemblies based on ASTM E2707. Identify conditions that create fire propagation hazards in exterior wall assemblies and educate the fire service on the findings.

42 ENGINEERING↗

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 173-C

Results of neutron dosimetry measurements in ATR for cycle 173-C are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗