Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tensile testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Tensile mechanical properties and fracture behaviors of nickel-based superalloy 718 in the presence of hydrogen

Hydrogen embrittlement of a nickel-based superalloy IN718 was investigated using slow strain rate tensile tests. Post-mortem observation of fractured samples was performed to explore hydrogen-assisted failure mechanisms of the alloy. The results reveal that hydrogen charging reduces yield strength, tensile strength, fracture strain and work hardening rate. With increasing current density, yield strength and tensile strength reduce linearly and fracture strain decreases exponentially. Furthermore, the crack initiation and propagation in hydrogen-charged region depends on the distribution of δ phase in the alloy. For needle-shaped δ phase within the grains, the nucleation of voids takes place at the intersections between dislocation slip bands and δ phase due to the hydrogen-enhanced localized plasticity (HELP)-assisted shear localization and possible hydrogen agglomeration. For δ phase along the grain boundaries, the impingement of slip bands and local hydrogen accumulation at γ-matrix/δ phase interfaces as well as hydrogen-enhanced decohesion (HEDE)-assisted decohesion lead to the void nucleation at the interfaces. Because of the decoration of δ phase at the grain boundaries, hydrogen-assisted cracking preferentially propagates along the grain boundaries. It is therefore suggested that the synergistic interplay of HELP mechanism and HEDE mechanism can be used to explain the embrittlement of the alloy.

08 HYDROGEN↗

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon(r) FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon(R) FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were X-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, X-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25 intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

deGroh, Kim K.↗

Alternative PWHT to Improve High-Temperature Mechanical Properties of Advanced 9Cr Steel Welds

Creep-resistant 9Cr steels are extremely important in thermal power generation industry due to their marked resistance to creep and corrosion. The weldability of these alloys is critical since they are used in welded construction equipment. The required mechanical properties are achieved after post-weld heat treatment. This study examined the effect of different post-weld heat treatments on microstructure and mechanical properties of creep strength-enhanced 9Cr steel welding deposits. It was obtained with an experimental flux-cored arc welding wire used under protective gas (Ar-20% CO{sub 2}). The heat treatments used were: (1) tempering (760 °C × 2 h), (2) solubilizing (1050 °C × 1 h) + tempering (760 °C × 2 h) and (3) solubilizing (1150 °C × 1 h) + first tempering (660 °C × 3 h) + second tempering (660 °C × 3 h). All-weld metal chemical composition was analyzed, and hot tensile tests were carried out at different temperatures. Charpy-V impact tests and Vickers microhardness measurements were also performed. Microstructures were studied using x-ray diffraction and optical and scanning electron microscopy. In all cases, a martensitic matrix with intergranular and intra-granular precipitates was detected. In the as-welded condition, δ-ferrite was also found. Microhardness dropped, and the impact energy increased with post-weld heat treatments. The highest hot tensile strength result was achieved with samples submitted to austenization at 1150 °C and double tempering at 660 °C.

36 MATERIALS SCIENCE↗

Comparison of High-Performance Fiber Materials Properties in Simulated and Actual Space Environments

A variety of high-performance fibers, including Kevlar, Nomex, Vectran, and Spectra, have been tested for durability in the space environment, mostly the low Earth orbital environment. These materials have been tested in yarn, tether/cable, and fabric forms. Some material samples were tested in a simulated space environment, such as the Atomic Oxygen Beam Facility and solar simulators in the laboratory. Other samples were flown on the International Space Station as part of the Materials on International Space Station Experiment. Mass loss due to atomic oxygen erosion and optical property changes due to ultraviolet radiation degradation are given. Tensile test results are also presented, including where moisture loss in a vacuum had an impact on tensile strength.

Finckenor, M. M.↗

Effect of Retrogression Heat Treatment Time on Microstructure and Mechanical Properties of AA7010

The effect of retrogression time during retrogression and re-aging (RRA) treatment of AA7010 is evaluated by performing tensile tests and characterizing the microchemistry of the grain boundary precipitates (GBPs) using transmission electron microscope coupled with the energy-dispersive spectroscopy. Retrogression time is evaluated so that the ultimate tensile strength of the RRA-treated sample is equal to that of the T6-treated sample and the grain boundary microstructure similar to that of the over-aged (T7451) condition. The investigation reveals that the sample retrogressed at 200 °C for 20 min has UTS of 586 MPa which is equivalent to that of the T6 sample and 11.5% higher than that of the T7451 condition. The fracture toughness of the RRA-treated sample was 41 MPa√m. Microstructure of the RRA-treated sample is similar to T7451, along the grain boundaries and in the grain interior similar to that of the T6-treated sample. Energy-dispersive spectroscopy confirmed the increment of Cu content on the GBP’s with increase in the retrogression time, which is expected to improve the stress corrosion cracking resistance of the alloy.

36 MATERIALS SCIENCE↗

The Effect of Weld Metal Composition on Microstructural and Mechanical Properties of Dissimilar Welds Between Monel 400 and Inconel 600

The current work was carried out to characterize welding of Inconel 600 superalloy and Monel 400. In the present study, gas tungsten arc welding (GTAW) with four types of filler metals (ENiCu, ENiCu-7, ENiCr-3 and ENiCrFe-3) was utilized. The filler metals were categorized into two groups based on the presence of Cr and Nb in their chemical composition. This paper describes the selection and application of welding consumables in manufacturing dissimilar metal combinations. It was found that (Nb/Cr) ratio and Fe content can affect on the size and amount of carbides. During solidification of ENiCr-3 and ENiCrFe-3 filler metals, Nb leaves dendritic cores and is rejected to inter-dendritic regions because of its high tendency for segregation. However, No brittle Laves phase was detected in the welds. The interface between weld metal and base metal and gradual changes in alloying elements were also investigated by scanning electron microscopy. EDX analysis was also applied for different samples. Microhardness measurements and tensile test were performed on the joints. The average hardness value in the weld metal obtained from ENiCrFe-3 is higher than the other welds. ENiCu-7 weld exhibited the highest tensile strength of 540 MPa and percent elongation of 53% in contrast to ENiCrFe-3 weld with the lowest tensile strength (518 MPa) and percent elongation (39%).

36 MATERIALS SCIENCE↗

Refining whisker size of 2024Al/Al18B4O33w composite through extrusion and its effects on the material's micro-structures and mechanical properties

Highlights: • The nonuniform distributions of stress and velocity along whisker lead to whisker breakage. • The microcrack between broken whiskers can propagate into interface or matrix, related to the wedge angle of broken whisker. • The whisker breakage and staggered result in the decreasing distance between neighboring whiskers. • The smaller distance between neighboring whiskers reduces the resistance to the propagation of crack resulting in the lower ultimate tensile strength of extruded composite. - Abstract: Hot extrusion is used to improve the distribution of whiskers and refine the whisker sizes of 2024Al/Al{sub 18}B{sub 4}O{sub 33}w composite. The grain size and the ultimate tensile strength of the extruded 2024Al/Al{sub 18}B{sub 4}O{sub 33}w composite are analyzed. The results show that the average length of whiskers decreases due to the whisker breakage. The nonuniform distributions of stress and velocity along the whisker lead to whisker breakage. The microcrack between the broken whiskers can propagate into the interface or the matrix, related to the wedge angle of the broken whisker. The extrusion is beneficial to the whisker staggered and makes it easy for the microcracks filled with matrix. The whisker breakage and the whisker staggered result in the decreasing distance between the neighboring whiskers. Due to the dislocation motion constrained by matrix and the overlap of the deformation areas, the decreasing distance between the neighboring whiskers promoting the recrystallization results in the smaller grain size. During tensile tests, due to the smaller resistance with the smaller distance between the neighboring whiskers, the cracks between the progressive broken whiskers are easy to coalesce resulting in the lower ultimate tensile strength of the extruded composite.

36 MATERIALS SCIENCE↗

Influence of processing conditions on the morphology of expanded perlite/polypropylene composites

Perlite is an oversaturated, volcanic, glassy rock, which has chemically bound water from 2 to 5 wt%. Upon heating, perlite can be expanded up to 20 times of its original volume. Important applications are in the field of building industry, in refrigeration engineering or the pharmaceutical industry. As mineral filler in polymers, expanded perlite can increase the thermal conductivity, the viscosity and the mechanical properties of polypropylene composites. But there are still many challenges that must be analyzed to reach the full potential of those composites. This research work focuses on the morphology of expanded perlite/polypropylene (PP) compounds and the interactions between filler and polymer. To achieve good performance a homogenous dispersion of the filler in the polymer matrix is needed because the enhancement of the material correlates strongly with the morphology of the composite. Therefore it is necessary to characterize the microstructure of these materials in order to establish adequate structure-process-property relationships. The expanded perlite/PP composites were compounded with a co-rotating twin screw extruder Theysohn TSK 30/40D. For producing the closed cell expanded perlite a new technology, the bublon process, was used. For the material characterization two particles sizes were chosen and the filler content was varied at 5, 10 and 15 wt%. For the analysis of the effects of the screw geometry, two setups have been chosen for the processing of the materials. The produced materials were analyzed by scanning electron microscope (SEM) and tensile testing. The results show a reinforcement effect of the filler and differences in the inner structure of expanded perlite and in the morphology.

36 MATERIALS SCIENCE↗

Effects of particle inclusions on cracking in ultrathin barrier films

Here, the effects of particle inclusions with different mechanical properties on the development of cracks in ultra-thin barrier films have been studied. Two types of particles, alumina and poly(styrene-b-methyl methacrylate) with large differences in their elastic modulus were used, representing both hard and soft inclusions. Particles were seeded onto polyethylene naphthalate substrates and subsequently coated with atomic layer deposited Al 2 O 3 as a barrier film. Ca corrosion tests used to determine the performance of the barrier films revealed that soft polymer particle inclusions severely affect the development of cracking in barrier films as compared to stiff ceramic particles. Tensile tests also confirmed that the barrier films with polymer particle inclusions have the lowest value of critical onset strain. Parametric simulations, conducted by varying the elastic modulus of the particle inclusions over a wide range, resulted in a larger strain energy release rate near particle inclusions which promotes crack formation and negatively impacts the performance of barrier films with softer particle inclusions. Thus, the combination of high residual stresses in the barrier films with the presence of soft particle inclusions is found the most detrimental for the development of high-performance ultrathin barrier films.

36 MATERIALS SCIENCE↗

The Initiation of Long-Term Creep Rupture Tests on the First Alloy 709 Commercial Heat

A systematic creep tests were conducted as part of a multi-lab effort to identify the material conditions for Alloy 709 Code Case Project. Nine candidate material conditions were studied with three melt conditions each with three S/A temperatures 1050, 1100 and 1150°C. The three melt conditions included AOD, ESR and ESR + Homogenization. The screening creep rupture tests were conducted under 600°C, 330MPa. AOD 1100 and ESR 1100 have been identified to be the top two material conditions for the Code Case project after a comprehensive evaluation. Long-term creep tests were initiated on AOD 1100 at the ORNL. The six creep tests were started at temperatures from 550 to 800°C, stresses from 38 to 309 MPa to target rupture time 60,000 hours. The loading strains agreed with those obtained from tensile tests at the corresponding temperatures.

36 MATERIALS SCIENCE↗

Characterization of Alloy 709 Commercial Heats

The creep-resistant austenitic stainless steel Alloy 709 (Fe-20Cr-25Ni (wt%) based steel) is being investigated as a candidate structural material for the next generation of advanced reactors. Unlike conventional solid solution strengthened austenitic stainless steels, Alloy 709 develops a variety of precipitates during aging at different temperatures and times. In this study, precipitate evolution during short-term aging at 775°C was characterized. The effect of aging time (e.g., 10 vs. 100 hours) and cooling after aging (e.g., water quench vs. air cool) on grain size and precipitates have been investigated using light optical microscopy (OM), electron backscatter diffraction (EBSD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). MX (Ni,Tb)(C,N) and M23C6 (Cr,Mo)C precipitates were observed in all the statically-aged samples. The grain size distribution in the sample aged for 10 hours and water quenched (10Q) versus the one aged for 100 hours and air cooled (100A) were comparable. This indicates that grain structure was fairly stable when aging at 775°C for up to 100 hours. In contrast, the sample aged for 10 hours and air cooled (10A) showed the smallest and the most uniform grain size distribution. This phenomenon was observed in only one sample. More studies on duplicate samples are needed to confirm the results obtained. The cooling medium (e.g., water quench vs. air cool) was not observed to impact the size nor the distribution of the MX and M23C6 precipitates. Increasing the aging time resulted in the following: (1) a decrease in dislocations as well as the number density of small precipitates; (2) an increase in the ratio of free precipitates that were not pinning dislocations; (3) relatively higher N, Nb, and Ti concentration in MX precipitate; (4) some increase in length of M23C6 carbides which were located on the coherent boundaries; and (5) the introduction of Sienriched M6X precipitates. The tensile tests at room temperature showed similar properties for each of the static aging treatments, indicating that the differences observed in the microstructural analysis did not have a significant impact on the tensile properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tensile Properties of Molybdenum and Tungsten from 2500 to 3700 F

Specimens of commercially pure sintered tungsten, arc-cast unalloyed molybdenum, and two arc-cast molybdenum-base alloys (one with 0.5 percent titanium, the other with 0.46 percent titanium and 0.07 percent zirconium) were fabricated from 1/2-inch-diameter rolled or swaged bars. All specimens were evaluated in short-time tensile tests in the as-received condition, and all except the molybdenum-titanium-zirconium alloy were tested after a 30-minute recrystallization anneal at 3800 F in a vacuum of approximately 0.1 micron. Results showed that the tungsten was considerably stronger than either the arc-cast unalloyed molybdenum or the molybdenum-base alloys over the 2500 to 3700 F temperature range. Recrystallization of swaged tungsten at 3800 F considerably reduced its tensile strength at 2500 F. However, above 3100 F, the as-swaged tungsten specimens recrystallized during testing, and had about the same strength as when recrystallized at 3800 F before evaluation. The ductility of molybdenum-base materials was very high at all test temperatures; the ductility of tungsten decreased sharply above about 3120 F.

Hall, Robert W.↗

Analysis of Tensile Deformation and Failure in Austenitic Stainless Steels: Part II- Irradiation Dose Dependence

Irradiation effects on stable and unstable deformations and fracture behaviors in irradiated austenitic stainless steels (SSs) have been studied in detail based on the equivalent true stress versus true strain curves. An iterative technique in finite element simulation was used to obtain the equivalent true stress-true strain data from experimental tensile curves. It was shown that the strain hardening rate was retained at a high level on unstable deformation after significant irradiation and was independent of the irradiation dose up to the initiation of a localized necking. The equivalent fracture stress was nearly independent of irradiation dose before the damage (embrittlement) mechanism changed. In low dose range (< ~ 2dpa), the fracture strain and tensile fracture energy decreased rapidly with dose and at higher doses they decreased gradually to saturated levels, which were still high for irradiated materials. It was also found that the fracture properties for EC316LN SS were less sensitive to irradiation dose than those for 316 SS, although their uniform tensile properties showed almost the same dose dependencies. It was confirmed that the dose dependence of tensile fracture properties evaluated by the linear approximation model for nominal stress was accurate enough for practical use without elaborate calculations.

36 MATERIALS SCIENCE↗

Tailoring properties and processing of Sylgard 184: Curing time, adhesion, and water affinity

The curing time, surface adhesion, and water absorption characteristics of Sylgard 184 were modified through the addition of catalysts and fillers. Incorporation of small amounts of a platinum-based Karstedt catalyst greatly decreased curing time at room temperature, whereas the addition of talcum powder (talc), polytetrafluoroethylene (PTFE), and NaY zeolite fillers changed surface adhesion and functionality of Sylgard 184. Fourier-transform infrared spectroscopy (FT-IR), rheological and mechanical tests (tensile strength and hardness) were used to quantify the acceleration in the curing time. The surface adhesion was evaluated for aluminum and glass-like substrates using a 90° peel-off test. The interaction between fillers and Sylgard was studied by molecular dynamics simulations, which showed the interaction between NaY and Sylgard is greater than that for PTFE. Finally, water absorption studies indicated that 10 wt% NaY added to Sylgard 184 helped to improve water absorption, whereas incorporation of talc had the opposite effect.

36 MATERIALS SCIENCE↗

Time-Dependent 600 °C Post-Weld Heat Treatment Response of Laser-Wire-Directed Energy Deposited Austenitic Stainless Steel Claddings on Carbon Steel

Austenitic stainless steel overlay claddings are often used to protect nuclear reactor pressure vessels from corrosion. Arc welding processes are traditionally employed, which require a high heat input to bond the dissimilar metals, creating a large heat-affected zone and high residual stress that demands a lengthy stress-relieving post-weld heat treatment, up to 48 hours. High energy beam (e.g., laser, electron beam) directed energy deposition-based overlay cladding processes show promise for fabricating claddings with superior performance compared to arc welded ones because of their localized heat input; however, their necessity and time of post-weld heat treatment are currently unclear. In this research, we investigate the time dependence of a 600 C stress-relieving post-weld heat treatment of austenitic stainless steel clad on low carbon steel by laser-wire-directed energy deposition, comparing the microstructure and mechanical properties of the as-fabricated condition to 2-, 10-, and 48-hour heat treatment times. Diffusion simulations and microscopy show a gradual carburization of the stainless steel cladding and decarburization of the heat-affected zone/base metal. Nanoindentation testing shows up to a 1.8–2.69 embrittlement in the cladding and a 0.33 to 0.69 softening in the heat-affected zone after the 48-hour post-weld heat treatment. Tensile testing of the cladding composites reveals that increasing post-weld heat treatment time raises clad cracking susceptibility due to intergranular carbide formation and shows that laser-wire-directed energy deposition claddings may not require post-weld heat treatment.

Coating↗

Precipitation hardening of laser powder bed fusion Ti-6Al-4V

Here, the laser powder bed fusion (PBF-L) additive manufacturing (AM) community has dedicated significant efforts into process optimization and control for defect-free Ti-6Al-4V. As defects become less of an issue for PBF-L Ti-6Al-4V, the processing-structure-properties (PSP) relationships between AM microstructures can now be explored to optimize mechanical properties. Lower temperature aging treatments around 550 °C in wrought Ti-6A-4V have been historically understood to precipitation harden the α phase with an ordered, hexagonal close packed (HCP) α 2 phase. The α 2 phase existed as nanoscale Ti 3 Al precipitates coherent with the parent α phase. The goal of the present investigation was to implement a vacuum heat treatment of 545 °C for 100 hours on PBF-L Ti-6Al-4V. This vacuum heat treatment took place after an initial hot isostatic pressure (HIP) treatment that decomposed the as-built, martensitic microstructure. The vacuum aging successfully produced nanoscale precipitates of α 2 phase within α-laths, confirmed via atom probe tomography (APT). Microstructural-length scale and quasi-static mechanical properties were investigated by nanoindentation and uniaxial tensile tests of miniaturized test specimens. Given the sensitivity of Ti-6Al-4V mechanical properties to small changes in chemistry, all test specimens originated from the same build. The α 2 precipitation resulted in significantly harder α-laths (≈ 2 GPa) as measured via nanoindentation, as well as a relative yield and ultimate tensile strength increase of 60 MPa and 38 MPa, respectively. Analysis of Variance (ANOVA) of the datasets revealed no statistical differences in total elongation between the HIPed and HIPed + aged specimens, indicative of the aging treatment producing a net benefit of strength with no loss in ductility.

36 MATERIALS SCIENCE↗

ASSESSMENT OF DEFORMATION MECHANISMS IN NEUTRON-IRRADIATED ACCIDENT-TOLERANT FeCrAl ALLOYS VIA IN SITU MECHANICAL TESTING AND TEM ANALYSIS

Iron-chromium-aluminum (FeCrAl) alloys are promising as an accident-tolerant fuel cladding for loss-of-coolant accident scenarios; however, limited data are available on acting deformation mechanisms for this class of materials after neutron irradiation. Here, in situ tensile test experiments were conducted with specimens irradiated at ~1.8 dpa at typical light water reactor temperatures. Selected regions of interest were examined at different strain levels, aiming to investigate the impact of irradiation on acting deformation mechanisms. The fine material microstructure was investigated via transmission electron microscopy. Dislocation structure, radiation-induced defects, and α'-phase morphology were investigated in detail and compared with scanning electron microscopy-electron backscatter diffraction and mechanical test results.

Gussev, Maxim N.↗

Influence of plasticizers on thermal and mechanical properties of biocomposite filaments made from lignin and polylactic acid for 3D printing

Polylactic acid (PLA) and organosolv lignin were mixed at different ratios and extruded to obtain PLA-lignin composite filaments. PLA was replaced with lignin up to 20 wt%. Two plasticizers (polyethylene glycol (PEG) 2000 and struktol TR451) were added in varying concentrations to enhance the properties of PLA_L20 (20% lignin in PLA) composite filaments. Furthermore, the effect of lignin in PLA, and PEG, and struktol in PLA_L20 composites was investigated via tensile test, differential scanning calorimetry, thermogravimetric analysis, scanning electron microscopy, Fourier transform infrared spectroscopy of the filaments, and dynamic mechanical analysis of 3D printed samples. A 2 wt% PEG was able to enhance both tensile stress and elongation at maximum load of PLA_L20 composite by 19% and 35%, respectively, whereas struktol TR451 was able to improve elongation at maximum load by 24%.

3D printing↗