Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

THE K2-ESPRINT PROJECT. I. DISCOVERY OF THE DISINTEGRATING ROCKY PLANET K2-22b WITH A COMETARY HEAD AND LEADING TAIL

We present the discovery of a transiting exoplanet candidate in the K2 Field-1 with an orbital period of 9.1457 hr: K2-22b. The highly variable transit depths, ranging from ∼0% to 1.3%, are suggestive of a planet that is disintegrating via the emission of dusty effluents. We characterize the host star as an M-dwarf with T{sub eff} ≃ 3800 K. We have obtained ground-based transit measurements with several 1-m class telescopes and with the GTC. These observations (1) improve the transit ephemeris; (2) confirm the variable nature of the transit depths; (3) indicate variations in the transit shapes; and (4) demonstrate clearly that at least on one occasion the transit depths were significantly wavelength dependent. The latter three effects tend to indicate extinction of starlight by dust rather than by any combination of solid bodies. The K2 observations yield a folded light curve with lower time resolution but with substantially better statistical precision compared with the ground-based observations. We detect a significant “bump” just after the transit egress, and a less significant bump just prior to transit ingress. We interpret these bumps in the context of a planet that is not only likely streaming a dust tail behind it, but also has a more prominent leading dust trail that precedes it. This effect is modeled in terms of dust grains that can escape to beyond the planet's Hill sphere and effectively undergo “Roche lobe overflow,” even though the planet's surface is likely underfilling its Roche lobe by a factor of 2.

79 ASTRONOMY AND ASTROPHYSICS↗

An electrochemical cell for in operando studies of lithium/sodium batteries using a conventional x-ray powder diffractometer

An electrochemical cell has been designed for powder X-ray diffraction studies of lithium ion batteries (LIB) and sodium ion batteries (SIB) in operando with high time resolution using a conventional powder X-ray diffractometer. The cell allows for studies of both anode and cathode electrode materials in reflection mode. The cell design closely mimics that of standard battery testing coin cells and allows obtaining powder X-ray diffraction patterns under representative electrochemical conditions. In addition, the cell uses graphite as the X-ray window instead of beryllium, and it is easy to operate and maintain. Test examples on lithium insertion/extraction in two spinel-type LIB electrode materials (Li{sub 4}Ti{sub 5}O{sub 12} anode and LiMn{sub 2}O{sub 4} cathode) are presented as well as first results on sodium extraction from a layered SIB cathode material (Na{sub 0.84}Fe{sub 0.56}Mn{sub 0.44}O{sub 2})

36 MATERIALS SCIENCE↗

Development of picoseconds Time of Flight systems in Meson Test Beam Facility at Fermilab

The goal of the work is to develop time of flight (TOF) system with about 10 picosecond time resolution in real beam line when start and stop counters separated by some distance. We name the distance as 'base' for the TOF. This 'real' TOF setup is different from another one when start and stop counters located next to each other. The real TOF is sensitive to beam momentum spread, beam divergence, etc. Anyway some preliminary measurements are useful with close placement of start and stop counter. We name it 'close geometry'. The work started about 2 years ago at Fermilab Meson Test Beam Facility (MTBF). The devices tested in 'close geometry' were Microchannel Plate Photomultipliers (MCP PMT) with Cherenkov radiators. TOF counters based on Silicon Photomultipliers (SiPms) with Cherenkov radiators also in 'close geometry' were tested. We report here new results obtained with the counters in the MTBF at Fermilab, including beam line data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, multichannel, and low noise arbitrary waveform generator

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined nanoplasmonic and electrodeless quartz crystal microbalance setup

We have developed an instrument combining localized surface plasmon resonance (LSPR) sensing with electrodeless quartz crystal microbalance with dissipation monitoring (QCM-D). The two techniques can be run simultaneously, on the same sensor surface, and with the same time resolution and sensitivity as for the individual techniques. The electrodeless QCM eliminates the need to fabricate electrodes on the quartz crystal and gives a large flexibility in choosing the surface structure and coating for both QCM-D and LSPR. The performance is demonstrated for liquid phase measurements of lipid bilayer formation and biorecognition events, and for gas phase measurements of hydrogen uptake/release by palladium nanoparticles. Advantages of using the combined equipment for biomolecular adsorption studies include synchronized information about structural transformations and extraction of molecular (dry) mass and degree of hydration of the adlayer, which cannot be obtained with the individual techniques. In hydrogen storage studies the combined equipment, allows for synchronized measurements of uptake/release kinetics and quantification of stored hydrogen amounts in nanoparticles and films at practically interesting hydrogen pressures and temperatures.

08 HYDROGEN↗

Trends in on-road vehicle emissions of ammonia

Motor vehicle emissions of ammonia have been measured at a California highway tunnel in the San Francisco Bay area. Between 1999 and 2006, light-duty vehicle ammonia emissions decreased by 38 {+-} 6%, from 640 {+-} 40 to 400 {+-} 20 mg kg{sup -1}. High time resolution measurements of ammonia made in summer 2001 at the same location indicate a minimum in ammonia emissions correlated with slower-speed driving conditions. Variations in ammonia emission rates track changes in carbon monoxide more closely than changes in nitrogen oxides, especially during later evening hours when traffic speeds are highest. Analysis of remote sensing data of Burgard et al. (Environ Sci. Technol. 2006, 40, 7018-7022) indicates relationships between ammonia and vehicle model year, nitrogen oxides, and carbon monoxide. Ammonia emission rates from diesel trucks were difficult to measure in the tunnel setting due to the large contribution to ammonia concentrations in a mixed-traffic bore that were assigned to light-duty vehicle emissions. Nevertheless, it is clear that heavy-duty diesel trucks are a minor source of ammonia emissions compared to light-duty gasoline vehicles.

25 ENERGY STORAGE↗

Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis

We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISAR optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EVIDENCE FOR THE OSCILLATING TWO STREAM INSTABILITY AND SPATIAL COLLAPSE OF LANGMUIR WAVES IN A SOLAR TYPE III RADIO BURST

We present observational evidence for the oscillating two stream instability (OTSI) and spatial collapse of Langmuir waves in the source region of a solar type III radio burst. High time resolution observations from the STEREO A spacecraft show that Langmuir waves excited by the electron beam occur as isolated field structures with short durations {approx}3.2 ms and with high intensities exceeding the strong turbulence thresholds. These short duration events are identified as the envelope solitons which have collapsed to spatial scales of a few hundred Debye lengths. The spectra of these wave packets contain an intense peak and two sidebands, corresponding to beam-resonant Langmuir waves, and down-shifted and up-shifted daughter Langmuir waves, respectively, and low-frequency enhancements below a few hundred Hz. The frequencies and wave numbers of these spectral components satisfy the resonance conditions of the OTSI. The observed high intensities, short scale lengths, sideband spectral structures, and low-frequency enhancements strongly suggest that the OTSI and spatial collapse of Langmuir waves probably control the nonlinear beam-plasma interactions in type III radio bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of pressure-displacement kinetics of hemoglobin in normal breast tissue with near-infrared spectral imaging

Applying localized external displacement to the breast surface can change the interstitial fluid pressure such that regional transient microvascular changes occur in oxygenation and vascular volume. Imaging these dynamic responses over time, while different pressures are applied, could provide selective temporal contrast for cancer relative to the surrounding normal breast. In order to investigate this possibility in normal breast tissue, a near-infrared spectral tomography system was developed that can simultaneously acquire data at three wavelengths with a 15 s time resolution per scan. The system was tested first with heterogeneous blood phantoms. Changes in regional blood concentrations were found to be linearly related to recovered mean hemoglobin concentration (HbT) values (R{sup 2}=0.9). In a series of volunteer breast imaging exams, data from 17 asymptomatic subjects were acquired under increasing and decreasing breast compression. Calculations show that a 10 mm displacement applied to the breast results in surface pressures in the range of 0-55 kPa depending on breast density. The recovered human data indicate that HbT was reduced under compression and the normalized change was significantly correlated to the applied pressure with a p value of 0.005. The maximum HbT decreases in breast tissue were associated with body mass index (BMI), which is a surrogate indicator of breast density. No statistically valid correlations were found between the applied pressure and the changes in tissue oxygen saturation (StO2) or water percentage (H2O) across the range of BMI values studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parametric Study of X-ray Energy Modulation for Depth Sensitive Backscatter Imaging

The technique of X-ray backscatter imaging has been studied for its applications in both medical imaging and nondestructive testing. The geometry and dimensionality of the detector system and photon source affect acquisition time, resolution, and signal to noise ratio (SNR) but the end result is still, at most, a 2D image. This is similar to transmission radiography with the difference being that the backscatter image has the benefit of requiring only single sided access to the object. Despite these physical limitations to the dimensions of a backscatter image, Towe and Jacobs showed that it is possible to obtain depth sensitive information (the third dimension in this case) by acquiring multiple images, each at a different X-ray tube voltage. By changing the average energy of the X-ray source, the penetration depth and therefore the signal which is generated from a backscatter design changes depending on the materials present in the object of interest. In order to further investigate the capabilities of depth sensitive X-ray backscatter imaging, a parametric study has been conducted on X-ray energy and its associated backscatter signal depth for materials relevant to medical imaging and non-destructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-scale thermalhydraulic analyses performed in Nuresim and Nurisp projects

The NURESIM and NURISP successive projects of the 6. and 7. European Framework Programs joined the efforts of 21 partners for developing and validating a reference multi-physics and multi-scale platform for reactor simulation. The platform includes system codes, component codes, and also CFD or CMFD simulation tools. Fine scale CFD simulations are useful for a better understanding of physical processes, for the prediction of small scale geometrical effects and for solving problems that require a fine space and/or time resolution. Many important safety issues usually treated at the system scale may now benefit from investigations at a CFD scale. The Pressurized Thermal Shock is investigated using several simulation scales including Direct Numerical Simulation, Large Eddy Simulation, Very Large Eddy Simulation and RANS approaches. At the end a coupling of system code and CFD is applied. Condensation Induced Water-Hammer was also investigated at both CFD and 1-D scale. Boiling flow in a reactor core up to Departure from Nucleate Boiling or Dry-Out is investigated at scales much smaller than the classical subchannel analysis codes. DNS was used to investigate very local processes whereas CFD in both RANS and LES was used to simulate bubbly flow and Euler-Lagrange simulations were used for annular mist flow investigations. Loss of Coolant Accidents are usually treated by system codes. Some related issues are now revisited at the CFD scale. In each case the progress of the analysis is summarized and the benefit of the multi-scale approach is shown. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Femtosecond time-resolved XUV + UV photoelectron imaging of pure helium nanodroplets

Liquid helium nanodroplets, consisting of on average 2 × 10{sup 6} atoms, are examined using femtosecond time-resolved photoelectron imaging. The droplets are excited by an extreme ultraviolet light pulse centered at 23.7 eV photon energy, leading to states within a band that is associated with the 1s3p and 1s4p Rydberg levels of free helium atoms. The initially excited states and subsequent relaxation dynamics are probed by photoionizing transient species with a 3.2 eV pulse and using velocity map imaging to measure time-dependent photoelectron kinetic energy distributions. Significant differences are seen compared to previous studies with a lower energy (1.6 eV) probe pulse. Three distinct time-dependent signals are analyzed by global fitting. A broad intense signal, centered at an electron kinetic energy (eKE) of 2.3 eV, grows in faster than the experimental time resolution and decays in ∼100 fs. This feature is attributed to the initially excited droplet state. A second broad transient feature, with eKE ranging from 0.5 to 4 eV, appears at a rate similar to the decay of the initially excited state and is attributed to rapid atomic reconfiguration resulting in Franck-Condon overlap with a broader range of cation geometries, possibly involving formation of a Rydberg-excited (He{sub n})* core within the droplet. An additional relaxation pathway leads to another short-lived feature with vertical binding energies ≳2.4 eV, which is identified as a transient population within the lower-lying 1s2p Rydberg band. Ionization at 3.2 eV shows an enhanced contribution from electronically excited droplet states compared to ejected Rydberg atoms, which dominate at 1.6 eV. This is possibly the result of increased photoelectron generation from the bulk of the droplet by the more energetic probe photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A CHANDRA/HETGS CENSUS OF X-RAY VARIABILITY FROM Sgr A* DURING 2012

We present the first systematic analysis of the X-ray variability of Sgr A* during the Chandra X-ray Observatory's 2012 Sgr A* X-ray Visionary Project. With 38 High Energy Transmission Grating Spectrometer observations spaced an average of 7 days apart, this unprecedented campaign enables detailed study of the X-ray emission from this supermassive black hole at high spatial, spectral and timing resolution. In 3 Ms of observations, we detect 39 X-ray flares from Sgr A*, lasting from a few hundred seconds to approximately 8 ks, and ranging in 2-10 keV luminosity from {approx}10{sup 34} erg s{sup -1} to 2 Multiplication-Sign 10{sup 35} erg s{sup -1}. Despite tentative evidence for a gap in the distribution of flare peak count rates, there is no evidence for X-ray color differences between faint and bright flares. Our preliminary X-ray flare luminosity distribution dN/dL is consistent with a power law with index -1.9{sup +0.3}{sub -0.4}; this is similar to some estimates of Sgr A*'s near-IR flux distribution. The observed flares contribute one-third of the total X-ray output of Sgr A* during the campaign, and as much as 10% of the quiescent X-ray emission could be comprised of weak, undetected flares, which may also contribute high-frequency variability. We argue that flares may be the only source of X-ray emission from the inner accretion flow.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comprehensive Library of X-Ray Pulsars in the Small Magellanic Cloud: Time Evolution of Their Luminosities and Spin Periods

We have collected and analyzed the complete archive of XMM-Newton (116), Chandra (151), and RXTE (952) observations of the Small Magellanic Cloud (SMC), spanning 1997–2014. The resulting observational library provides a comprehensive view of the physical, temporal, and statistical properties of the SMC pulsar population across the luminosity range of L{sub X}=10{sup 31.2}--10{sup 38} erg s{sup −1}. From a sample of 65 pulsars we report ∼1654 individual pulsar detections, yielding ∼1260 pulse-period measurements. Our pipeline generates a suite of products for each pulsar detection: spin period, flux, event list, high time-resolution light curve, pulse profile, periodogram, and spectrum. Combining all three satellites, we generated complete histories of the spin periods, pulse amplitudes, pulsed fractions, and X-ray luminosities. Some pulsars show variations in pulse period due to the combination of orbital motion and accretion torques. Long-term spin-up/spin-down trends are seen in 12/11 pulsars, respectively, pointing to sustained transfer of mass and angular momentum to the neutron star on decadal timescales. Of the sample, 30 pulsars have a relatively very small spin period derivative and may be close to equilibrium spin. The distributions of pulse detection and flux as functions of spin period provide interesting findings: mapping boundaries of accretion-driven X-ray luminosity and showing that fast pulsars (P < 10 s) are rarely detected, which as of yet are more prone to giant outbursts. Accompanying this paper is an initial public release of the library so that it can be used by other researchers. We intend the library to be useful in driving improved models of neutron star magnetospheres and accretion physics.

79 ASTRONOMY AND ASTROPHYSICS↗