Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Integrating Cybersecurity with System Operations and Restoration

This presentation covers the interaction of the discipline of system operations with the discipline of cybersecurity. First, a common mental model for risk - both cybersecurity and all-hazards - is presented, followed by a discussion of high-level management strategies for different kinds of cyber harm facing system operators, based on the consequences and frequencies of the harm. The next section covers the importance of cybersecurity for a system operator organization and explains some general concepts to understand the relationships. Finally the role of system operators in the security of the grid as a larger system of systems is discussed over the framework of a resilience event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing against errors in an error correcting code (ECC) implemented in an automotive system

In general, data is susceptible to errors caused by faults in hardware (i.e. permanent faults), such as faults in the functioning of memory and/or communication channels. To detect errors in data caused by hardware faults, the error correcting code (ECC) was introduced, which essentially provides a sort of redundancy to the data that can be used to validate that the data is free from errors caused by hardware faults. In some cases, the ECC can also be used to correct errors in the data caused by hardware faults. However, the ECC itself is also susceptible to errors, including specifically errors caused by faults in the ECC logic. A method, computer readable medium, and system are thus provided for securing against errors in an ECC.

Saxena, Nirmal Raj↗

Quantifying Availability in SCADA Environments Using the Cyber Security Metric MFC

Supervisory Control and Data Acquisition (SCADA) systems are distributed networks dispersed over large geographic areas that aim to monitor and control industrial processes from remote areas and/or a centralized location. They are used in the management of critical infrastructures such as electric power generation, transmission and distribution, water and sewage, manufacturing/industrial manufacturing as well as oil and gas production. The availability of SCADA systems is tantamount to assuring safety, security and profitability. SCADA systems are the backbone of the national cyber-physical critical infrastructure. Herein, we explore the definition and quantification of an econometric measure of availability, as it applies to SCADA systems; our metric is a specialization of the generic measure of mean failure cost.

Availability↗

3He and BF3 Neutron Detector Pressure Effect and Model Comparison

Paper for SORMA conference Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor (RPM) systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in RPMs because 3He has a large neutron cross section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride (BF3) gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used, not enough to solve the shortage but perhaps enough to increase the amount of time available to find a working replacement. BF3 is not appropriate for all situations as these detectors are less sensitive than 3He, BF3 gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and BF3 as a function of tube pressure were made. The experimental results were also used to validate models of the RPMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Domestic Molten Salt Reactor: Security-by-Design

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. The past approach has often included implementing security features after a facility has been designed and without attention to optimization, which can lead to cost overruns. Incorporating security in the design process can provide robust, economical, and effective physical protection systems (PPS). The purpose of this work is both to develop a framework for the integration of security into the design phase of a molten salt reactor (MSR) and show how to effectively design a PPS with a reduced staffing headcount. Specifically, this work focuses on integrating PPS design features into a developed facility layout by making minor modifications to building structures. A suite of tools, including Scribe3D©, PathTrace©, and Blender©, were used to model a hypothetical, generic domestic MSR facility. Physical protection elements such as sensors, cameras, barriers, and responders were added into the model based on defending the hypothetical MSR facility against a hypothetical design basis threat (DBT). Multiple outsider sabotage scenarios were examined, with adversary team sizes ranging from 4–8 to determine security system effectiveness. The results of this work will influence PPS designs and facility designs for U.S. domestic MSRs. This work will also demonstrate how a series of experimental and modeling capabilities across the Department of Energy (DOE) complex can impact the design and completion of security-by-design (SeBD) for small modular reactors (SMRs). The conclusions and recommendations in this document may be applicable to all SMR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Small Modular Reactor and Microreactor Security-by-Design Lessons Learned: Integrated PPS Designs

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. The past approach has often included implementing security features after a facility has been designed and without attention to optimization, which can lead to cost overruns. Incorporating security into the design process can provide robust, cost-effective, and sufficient physical protection systems. The purpose of this report is to capture lessons learned by the Advanced Reactor Safeguards and Security (ARSS) program that may be beneficial for other advanced and small modular reactor (SMR) vendors to use when developing security systems and postures. This report will capture relevant information that can be used in the security-by-design (SeBD) process for SMR and microreactor vendors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

IBR Digital Supply Chain Gap Analysis and Recommendations

The adoption of clean energy technologies, including solar photovoltaics, continues to introduce non-traditional stakeholders to the operations and planning of the electric system. Stakeholders such as manufacturers, vendors, owners, aggregators, and others are enabling the adoption, integration, and optimum operations of solar technologies at accelerated rates. Inverters form the foundation of many digitally controlled energy sources for clean energy technologies, including Solar, Battery Energy Storage Systems, Hybrid Systems, and Hydrogen Fuel Cells. Their supply chain is complex, a series of microchips, electronic switches and other components making up its primary functions. The complexity of this space and the growing digitization associated with these components can create supply chain cyber risks. One measure to mitigate cybersecurity attacks is proper digital supply chain security. The U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), in partnership with the Cybersecurity, Energy, Security, and Emergency Response (CESER) office, is hosting a workshop to bring together solar vendors and services providers to discuss digital supply chain security for solar systems and challenges and opportunities in the transitioning to a fully domestic supply chain for solar energy in the U.S. This workshop will support the Securing Solar for the Grid (S2G) and Energy Cyber Sense program activities. During the workshop, industry experts and researchers from DOE National Laboratories will discuss the current solar supply chain landscape and the transition to domestic manufacturing of solar components in the U.S. Tools and techniques to better manage and secure the digital supply chain of solar devices and systems will be discussed.

cybersecurity↗

Microgrid Design, Development and Demonstration - Final Report for Phase I and Phase II

This document constitutes GE’s final report for the Microgrid Design, Development and Demonstration program for DOE’s Office of Electricity Delivery and Energy Reliability, Award DE-FC02-05CH11349. It contains the final report for Phase I in Appendix I, and the results the work performed in Phase II. The program goal was to develop and demonstrate a Microgrid Energy Management (MEM) framework for a broad set of Microgrid applications that provides unified controls, protection, and energy management. This project contributed to the achievement of the U.S. Department of Energy’s Renewable and Distributed Systems Integration Program goals by developing a fully automated power delivery microgrid network that: - Reduces carbon emissions and emissions of other air pollutants through increased use of optimally dispatched renewable energy, - Increases asset use through integration of distributed systems, - Enhances reliability, security, and resiliency from microgrid applications in critical infrastructure protection, constrained areas of the electric grid, etc. - Improves system efficiency with on-site, distributed generation and improved economic efficiency through demand-side management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building a Secure and Feature-rich Mobile Mapping Service App Using HTML5: Challenges and Best Practices

Managing a wide variety of mobile devices across multiple mobile operating systems is a security challenge for any organization [1, 2]. With the wide adoption of mobile devices to access work-related apps, there is an increase in third-party apps that might either misuse or improperly handle user s personal or sensitive data [3]. HTML5 has been receiving wide attention for developing cross-platform mobile apps. According to International Data Corporation (IDC), by 2015, 80% of all mobile apps will be based in part or wholly upon HTML5 [4]. Though HTML5 provides a rich set of features for building an app, it is a challenge for organizations to deploy and manage HTML5 apps on wide variety of devices while keeping security policies intact. In this paper, we will describe an upcoming secure mobile environment for HTML5 apps, called Sencha Space that addresses these issues and discuss how it will be used to design and build a secure and cross-platform mobile mapping service app. We will also describe how HTML5 and a new set of related technologies such as Geolocation API, WebGL, Open Layers 3, and Local Storage, can be used to provide a high end and high performance experience for users of the mapping service app.

Karthik, Rajasekar↗

Key Management Challenges in Smart Grid

Agenda Awarded in February 2011 Team of industry and research organizations Project Objectives Address difficult issues Complexity Diversity of systems Scale Longevity of solution Participate in standards efforts and working groups Develop innovative key management solutions Modeling and simulation ORNL Cyber Security Econometric Enterprise System Demonstrate effectiveness of solution Demonstrate scalability

99 GENERAL AND MISCELLANEOUS↗

Electro-mechanical Modeling of Wind Turbine and Energy Storage Systems with Enhanced Inertial Response

In this paper, a coordinated control scheme for wind turbine generator (WTG) and supercapacitor energy storage system (ESS) is proposed for temporary frequency supports. Inertial control is designed by using generator torque limit considering the security of WTG system, while ESS releases its energy to compensate the sudden active power deficit during the recovery process of turbine rotor. WTG is modeled using the fatigue, aerodynamic, structure, turbulence (FAST) code, which identifies the mechanical loadings of the turbine and addresses electro-mechanical interactions in the wind energy system. A damping controller is augmented to the inertial control to suppress severe mechanical oscillations in the shaft and tower of the turbine during frequency supports. Furthermore, the result of small-signal stability analysis shows that the WTG-ESS tends to improve the stability of the whole multi-energy power grid. The major contributions of this paper will be validated by utilizing the proposed control method that combines the grid support capability and maintaining the integrity of structural design of the turbine for normal operations.

17 WIND ENERGY↗

FY 2021 High Performance Computing Overall Systems Availability

INL HPC capabilities were utilized by individuals at universities, industry, and government laboratories for a wide range of research and engineering activities between October 1, 2020 and September 30, 2021. The HPC systems themselves experienced minimal downtime over the course of the fiscal year. Most downtime was planned to apply critical security patches to system software. The most serious of the unplanned downtime events occurred due to maintenance on the Kohler backup generator in July. Users were kept notified of all events, both planned and unplanned, via 36 total email notifications in FY-21. The INL HPC systems continue to provide high availability for collaboration and innovation in nuclear energy systems research.

99 GENERAL AND MISCELLANEOUS↗

Addressing tokens dynamic generation, propagation, storage and renewal to secure the GlideinWMS pilot based jobs and system

GlideinWMS has been one of the first middleware in the WLCG community to transition from X.509 to support also tokens. The first step was to get from the prototype in 2019 to using tokens in production in 2022. This paper will present the challenges introduced by the wider adoption of tokens and the evolution plans for securing the pilot infrastructure of GlideinWMS and supporting the new requirements. In the last couple of years, the GlideinWMS team supported the migration to tokens of experiments and resources. Inadequate support in the current infrastructure, more stringent requirements, and the higher spatial and temporal granularity forced GlideinWMS to revisit once more how credentials are generated, used, and propagated. The new credential modules have been designed to be used in multiple systems (GWMS, HC) and use a model where credentials have type, purpose, and different flows. Credentials are dynamically generated in order to customize the duration and limit the scope to the targeted resource. This allows to enforce the least privilege principle. Finally, we also considered adding credential storage, renewal, and invalidation mechanisms within the GlideinWMS infrastructure to serve better the experiments’ needs.

Mambelli, Marco↗

Addressing tokens dynamic generation, propagation, storage and renewal to secure the GlideinWMS pilot based jobs and system

GlideinWMS has been one of the first middleware in the WLCG community to transition from X.509 to support also tokens. The first step was to get from the prototype in 2019 to using tokens in production in 2022. This paper will present the challenges introduced by the wider adoption of tokens and the evolution plans for securing the pilot infrastructure of GlideinWMS and supporting the new requirements. In the last couple of years, the GlideinWMS team supported the migration of experiments and resources to tokens. Inadequate support in the current infrastructure, more stringent requirements, and the higher spatial and temporal granularity forced GlideinWMS to revisit once more how credentials are generated, used, and propagated. The new credential modules have been designed to be used in multiple systems (GlideinWMS, HEPCloud) and use a model where credentials have type, purpose, and different flows. Credentials are dynamically generated in order to customize the duration and limit the scope to the targeted resource. This allows to enforce the least privilege principle. Finally, we also considered adding credential storage, renewal, and invalidation mechanisms within the GlideinWMS infrastructure to better serve the experiments' needs.

Coimbra, Bruno Moreira [Fermilab] (ORCID:000900022↗

Validating a Dynamic PWR Safety and Security Model?

Nuclear power plants (NPPs) are assessed for safety and security using separate models that cannot capture how an attacker's decisions and a plant's response unfold together in real time, leaving regulators and operators without a complete picture of true plant vulnerability. Traditional probabilistic risk assessment (PRA) methods treat adversarial events as fixed initiators with predetermined outcomes, and are structurally incapable of representing the time-dependent interplay between physical security events, safety system response, and operator mitigative actions. At Idaho National Laboratory (INL), I contributed to the development and validation of Modeling and Analysis for Safety and Security using the Dynamic EMRALD Framework (MASS-DEF). Where static PRA relies on event-tree logic that cannot evolve mid-scenario, MASS-DEF couples a time-dependent dynamic PRA tool EMRALD (Event Modeling Risk Assessment using Linked Diagrams) with attack simulation software, allowing attacker behavior, plant system states, and operator actions to interact across time. My work focused on validating a general Pressurized Water Reactor (PWR) model. I traced model logic against PWR plant to identified errors in logic and confirm accuracy. I then built and tested attack scenarios against a general PWR model to verify that the model produced expected outcomes across all logical pathways. I also contributed a section to a related technical paper applying the same EMRALD platform to radiation dose modeling. Results show that MASS-DEF can quantitatively demonstrate that many plants exceed their regulatory security thresholds. This demonstrated margin provides a technically defensible basis for reducing the number of guards without compromising regulatory compliance. Physical security costs represent roughly 10% of annual operating budgets, making such reductions directly meaningful to INL's mission of sustaining existing commercial NPPs. This internship strengthened my understanding of nuclear systems, probabilistic modeling, and technical writing, and has solidified my pursuit of a career at a national laboratory.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗