Cobalt-base alloy

A microstructurally stable, high strength cobalt based alloy for use at elevated temperatures to 2125 F was developed. The alloys are particularly directed for use in stators and other low stress components in advanced gas turbines.

Dreshfield, R. L.↗

Advanced two-stage compressor program design of inlet stage

The aerodynamic design of an inlet stage for a two-stage, 10/1 pressure ratio, 2 lb/sec flow rate compressor is discussed. Initially a performance comparison was conducted for an axial, mixed flow and centrifugal second stage. A modified mixed flow configuration with tandem rotors and tandem stators was selected for the inlet stage. The term conical flow compressor was coined to describe a particular type of mixed flow compressor configuration which utilizes axial flow type blading and an increase in radius to increase the work input potential. Design details of the conical flow compressor are described.

Bryce, C. A.↗

Aviation Forecasting in ICAO

Opinions or plans of qualified experts in the field are used for forecasting future requirements for air navigational facilities and services of international civil aviation. ICAO periodically collects information from Stators and operates on anticipated future operations, consolidates this information, and forecasts the future level of activity at different airports.

Mcmahon, J.↗

Performance of transonic fan stage with weight flow per unit annulus area of 178 kilograms per second per square meter (6.5(lb/sec)/(sq ft))

The overall and blade-element performances are presented over the stable flow operating range from 50 to 100 percent of design speed. Stage peak efficiency of 0.834 was obtained at a weight flow of 26.4 kg/sec (58.3 lb/sec) and a pressure ratio of 1.581. The stall margin for the stage was 7.5 percent based on weight flow and pressure ratio at stall and peak efficiency conditions. The rotor minimum losses were approximately equal to design except in the blade vibration damper region. Stator minimum losses were less than design except in the tip and damper regions.

Moore, R. D.↗

Development of a mercury electromagnetic centrifugal pump for the SNAP-8 refractory boiler development program

An electromagnetic pump, in which pressure is developed in mercury because of the interaction of the magnetic field and current which flows as a result of the voltage induced in the mercury contained in the pump duct, was developed for the SNAP-8 refractory boiler test facility. Pump performance results are presented for ten duct configurations and two stator sizes. These test results were used to design and fabricate a pump which met the SNAP-8 criteria of 530 psi developed pressure at 12,500 lb/hr. The pump operated continuously for over 13,000 hours without failure or performance degradation. Included in this report are descriptions of the experimental equipment, measurement techniques, all experimental data, and an analysis of the electrical losses in the pump.

Fuller, R. A.↗

Particle flow in blade passages of turbomachinery with application to laser-Doppler velocimetry

A theoretical analysis was conducted of the dynamic behavior of micron size particles entrained in gas flow on the two-dimensional blade-to-blade surface of a circular stationary cascade of turbine stator blades. The particle velocity lag and angular deviation relative to the gas was determined as a function of particle diameter and mass density. Particles size and density were varied over ranges selected to correspond to typical laser-Doppler velocimeter (LDV) flow field mapping applications. It was found that velocity lag and angular deviation increased whenever particle size or mass density increased, and that particle tracking was more sensitive to a change in particle diameter than to a change in mass density. Results indicated that LDV applications employing 1 gm/cc tracer particles with diameters greater than approximately 1 micron, or 0.5 micron diameter particles with mass densities greater than 4 gm/cc would experience velocity and angular deviations generally greater than 2 percent and 1 degree, respectively.

Maxwell, B. R.↗

Determination of life for a polyimide-epoxy alternator insulation system

Tests were conducted to predict remaining electrical insulation life of a polyimide epoxy insulated 60 KW, 208 volt homopolar inductor alternator, following completion of 23,130 hours of turbo-alternator endurance tests. The sectioned armature winding of this alternator stator was used as means to evaluate and measure end-life at several aging temperatures for development of an Arrhenius plot. A one-half life rate of 11.3 C was established from these data with a predicted remaining life of 60,000 hours at an armature winding temperature of 248 C and a total life, including endurance test time, of 61,645 hours.

Penn, W. B.↗

Investigation of the large scale coherent structure in a jet and its relevance to jet noise

A study was conducted to determine the causes of aircraft noise in large jet aircraft. It was determined that jet noise varies strongly with velocity and that significant pure tones are generated by rotor-stator interaction in the jet engines. An objective method for deducing the large eddy structure in a large jet is described. The provisions of lighthill's theory are analyzed and applied to investigating the nature of jet noise. There is considerable evidence that a large scale coherent structure exists in a jet and that this structure can play a major role in sound radiation. Mathematical models are developed to define the parameters of orthogonal decomposition, finite extent velocity field, homogeneous fields, and periodic velocity fields.

Arndt, R. E. A.↗

Performance of a 1.15-pressure-ratio axial-flow fan stage with a blade tip solidity of 0.5

The overall and blade-element performance of a low-solidity, low-pressure-ratio, low-tip-speed fan stage is presented over the stable operating range at rotative speeds from 90 to 120 percent of design speed. At design speed a stage peak efficiency of 0.836 was obtained at a weight flow of 30.27 kilograms per second and a pressure ratio of 1.111. The pressure ratio was less than design pressure ratio, and the design energy input into the rotor was not achieved. A mismatch of the rotor and stator blade elements resulted due to the lower than design pressure ratio of the rotor.

Osborn, W. M.↗

Analytic models of ducted turbomachinery tone noise sources. Volume 1: Analysis

The analytic models developed for computing the periodic sound pressure of subsonic fans and compressors in an infinite, hardwall annular duct with uniform flow are described. The basic sound-generating mechanism is the scattering into sound waves of velocity disturbances appearing to the rotor or stator blades as a series of harmonic gusts. The models include component interactions and rotor alone.

Clark, T. L.↗

Effects of forward velocity and acoustic treatment on inlet fan noise

Flyover and static noise data from several engines are presented that show inlet fan noise measured in flight can be lower than that projected from static tests for some engines. The differences between flight and static measurements appear greatest when the fan fundamental tone due to rotor-stator interaction or to the rotor alone field is below cutoff. Data from engine and fan tests involving inlet treatment on the walls only are presented that show the attenuation from this treatment is substantially larger than expected from previous theories or flow duct experience. Data showing noise shielding effects due to the location of the engine on the airplane are also presented. These observations suggest that multiringed inlets may not be necessary to achieve the desired noise reduction in many applications.

Feiler, C. E.↗

Performance of a highly loaded two stage axial-flow fan

A two-stage axial-flow fan with a tip speed of 1450 ft/sec (442 m/sec) and an overall pressure ratio of 2.8 was designed, built, and tested. At design speed and pressure ratio, the measured flow matched the design value of 184.2 lbm/sec (83.55kg/sec). The adiabatic efficiency at the design operating point was 85.7 percent. The stall margin at design speed was 10 percent. A first-bending-mode flutter of the second-stage rotor blades was encountered near stall at speeds between 77 and 93 percent of design, and also at high pressure ratios at speeds above 105 percent of design. A 5 deg closed reset of the first-stage stator eliminated second-stage flutter for all but a narrow speed range near 90 percent of design.

Ruggeri, R. S.↗

Two stage low noise advanced technology fan. 1: Aerodynamic, structural, and acoustic design

A two-stage fan was designed to reduce noise 20 db below current requirements. The first-stage rotor has a design tip speed of 365.8 m/sec and a hub/tip ratio of 0.4. The fan was designed to deliver a pressure ratio of 1.9 with an adiabatic efficiency of 85.3 percent at a specific inlet corrected flow of 209.2kg/sec/sq m. Noise reduction devices include acoustically treated casing walls, a flowpath exit acoustic splitter, a translating centerbody sonic inlet device, widely spaced blade rows, and the proper ratio of blades and vanes. Multiple-circular-arc rotor airfoils, resettable stators, split outer casings, and capability to go to close blade-row spacing are also included.

Messenger, H. E.↗

Aerodynamic performance of a 1.25-pressure-ratio axial-flow fan stage

Aerodynamic design parameters and overall and blade-element performances of a 1.25-pressure-ratio fan stage are reported. Detailed radial surveys were made over the stable operating flow range at rotative speeds from 70 to 120 percent of design speed. At design speed, the measured stage peak efficiency of 0.872 occurred at a weight flow of 34.92 kilograms per second and a pressure ratio of 1.242. Stage stall margin is about 20 percent based on the peak efficiency and stall conditions. The overall peak efficiency for the rotor was 0.911. The overall stage performance showed no significant change when the stators were positioned at 1, 2, or 4 chords downstream of the rotor.

Moore, R. D.↗

Effects of forward velocity and acoustic treatment on inlet fan noise

Flyover and static noise data from several engines are presented that show inlet fan noise measured in flight can be lower than that projected from static tests for some engines. The differences between flight and static measurements appear greatest when the fan fundamental tone due to rotor-stator interaction or to the rotor-alone field is below cutoff. Data from engine and fan tests involving inlet treatment on the walls only are presented that show the attenuation from this treatment is substantially larger than expected from previous theories or flow duct experience. Data showing noise shielding effects due to the location of the engine on the airplane are also presented. These observations suggest that multiringed inlets may not be necessary to achieve the desired noise reduction in many applications.

Feiler, C. E.↗

Highly loaded multi-stage fan drive turbine: Performance of final three configurations

Results for a three-stage highly loaded fan drive turbine follow-on test program are presented. The effects of combinations of tandem and leaned bladerows on three-stage turbine performance were tested. The three-stage turbine with a tandem stator in stage two exhibited a total-to-total efficiency of approximately 0.887 as compared to 0.886 for the plain blade turbine base case.

Cherry, D. G.↗

Two-stage fan. 2: Data and performance with redesigned second stage rotor uniform and distorted inlet flows

A two-stage fan with a first rotor tip speed of 1450 ft/sec (441.96 m/sec) and no inlet guide vanes was tested with uniform and distorted inlet flows, with a redesigned second rotor having a part span shroud to prevent flutter, with variable-stagger stators set in nominal positions, and without rotor casing treatment. The fan achieved a pressure ratio 2.8 at a corrected flow of 185.4 lbm/sec (84.0 kg/sec), an adiabatic efficiency of 85.0 percent, and a stall margin of 12 percent. The redesigned second rotor did not flutter. Tip radial distortion reduced the stall margin at intermediate speed, but had little effect on stall margin at high or low speeds. Hub radial distortion reduced the stall margin at design speed but increased stall margin at low speed. Circumferential distortion reduced stall pressure ratio and flow to give approximately the same stall lines with uniform inlet flow. Distortions were attenuated by the fan. For Vol. 1, see N74-11421.

Messenger, H. E.↗

Compressibility effects in the Kemp-Sears Problem

The effects of including compressibility in the Kemp-Sears problem of aerodynamic interference between moving blade rows are examined. Methods of linearized, subsonic, plane, unsteady flow are adopted. The major new effect is that a resonance appears at certain combinations of flow Mach number, tip Mach number, and blade vane ratios. The resonance is at exactly the Tyler-Sofrin cutoff condition for rotor-stator interaction. At such conditions the unsteady lift on a blade row due to externally imposed nonstationary upwash vanishes. However, the resonance appears to be very sharp and seems to be more significant as an indication that around this condition the unsteady lift changes very rapidly.

Mani, R.↗