Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Clinical Outcomes and Late Endocrine, Neurocognitive, and Visual Profiles of Proton Radiation for Pediatric Low-Grade Gliomas

Purpose/Objective(s): Primary low-grade gliomas are common brain tumors of childhood, many of which require radiation therapy (RT) as definitive treatment. Increased conformality of RT could decrease the incidence and severity of late effects. We report our experience with 32 pediatric patients treated with proton RT. Methods and Materials: Thirty-two pediatric patients with low-grade gliomas of the brain or spinal cord were treated with proton RT from 1995 to 2007. Sixteen patients received at least 1 regimen of chemotherapy before definitive RT. The median radiation dose was 52.2 Gy{sub RBE} (48.6-54 Gy{sub RBE}). Results: The median age at treatment was 11.0 years (range, 2.7-21.5 years), with a median follow-up time of 7.6 years (range, 3.2-18.2 years). The 6-year and 8-year rates of progression-free survival were 89.7% and 82.8%, respectively, with an 8-year overall survival of 100%. For the subset of patients who received serial neurocognitive testing, there were no significant declines in Full-Scale Intelligence Quotient (P=.80), with a median neurocognitive testing interval of 4.5 years (range, 1.2-8.1 years) from baseline to follow-up, but subgroup analysis indicated some significant decline in neurocognitive outcomes for young children (<7 years) and those with significant dose to the left temporal lobe/hippocampus. The incidence of endocrinopathy correlated with a mean dose of ≥40 Gy{sub RBE} to the hypothalamus, pituitary, or optic chiasm. Stabilization or improvement of visual acuity was achieved in 83.3% of patients at risk for radiation-induced injury to the optic pathways. Conclusions: This report of late effects in children with low-grade gliomas after proton RT is encouraging. Proton RT appears to be associated with good clinical outcome, especially when the tumor location allows for increased sparing of the left temporal lobe, hippocampus, and hypothalamic-pituitary axis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Clinical Implementation of a Universal Bolus to Maintain Spot Size During Delivery of Base of Skull Pencil Beam Scanning Proton Therapy

Purpose: To report on a universal bolus (UB) designed to replace the range shifter (RS); the UB allows the treatment of shallow tumors while keeping the pencil beam scanning (PBS) spot size small. Methods and Materials: Ten patients with brain cancers treated from 2010 to 2011 were planned using the PBS technique with bolus and the RS. In-air spot sizes of the pencil beam were measured and compared for 4 conditions (open field, with RS, and with UB at 2- and 8-cm air gap) in isocentric geometry. The UB was applied in our clinic to treat brain tumors, and the plans with UB were compared with the plans with RS. Results: A UB of 5.5 cm water equivalent thickness was found to meet the needs of the majority of patients. By using the UB, the PBS spot sizes are similar with the open beam (P>.1). The heterogeneity index was found to be approximately 10% lower for the UB plans than for the RS plans. The coverage for plans with UB is more conformal than for plans with RS; the largest increase in sparing is usually for peripheral organs at risk. Conclusions: The integrity of the physical properties of the PBS beam can be maintained using a UB that allows for highly conformal PBS treatment design, even in a simple geometry of the fixed beam line when noncoplanar beams are used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Usefulness of {sup 18}F-Fluorodeoxyglucose-Positron Emission Tomography in Patients With Locally Advanced Pancreatic Cancer Planned to Undergo Concurrent Chemoradiation Therapy

Purpose: To assess the role of coregistered {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) in detecting radiographically occult distant metastasis (DM) at staging in patients with locally advanced pancreatic cancer (LAPC) and to study whether FDG-PET parameters can predict relatively long-term survival in patients who are more likely to benefit from chemoradiation therapy (CRT). Methods and Materials: From our institutional database, we identified 388 LAPC patients with M0 on conventional computed tomography (CT) who were planned to undergo CRT. Coregistered FDG-PET staging was offered to all patients, and follow-up FDG-PET was used at the clinical discretion of the physician. Results: FDG-PET detected unsuspected CT-occult DM in 33% of all 388 patients and allowed them to receive systemic therapy immediately. The remaining 260 patients (PET-M0) underwent CRT selectively as an initial treatment. Early DM arose in 13.1% of 260 patients, and the 1-year estimated locoregional recurrence rate was 5.4%. Median overall survival (OS) and progression-free survival (PFS) were 14.6 and 9.3 months, respectively, at a median follow-up time of 32.3 months (range, 10-99.1 months). Patients with a baseline standardized uptake value (SUV) <3.5 and/or SUV decline ≥60% had significantly better OS and PFS than those having none, even after adjustment for all potential confounding variables (all P<.001). Conclusions: FDG-PET can detect radiographically occult DM at staging in one-third of patients and spare them from the potentially toxic therapy. Additionally, FDG-PET parameters including baseline SUV and SUV changes may serve as useful clinical markers for predicting the prognosis in LAPC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Patterns After Hemithoracic Pleural Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma

Purpose: We previously reported our technique for delivering intensity modulated radiation therapy (IMRT) to the entire pleura while attempting to spare the lung in patients with malignant pleural mesothelioma (MPM). Herein, we report a detailed pattern-of-failure analysis in patients with MPM who were unresectable or underwent pleurectomy/decortication (P/D), uniformly treated with hemithoracic pleural IMRT. Methods and Materials: Sixty-seven patients with MPM were treated with definitive or adjuvant hemithoracic pleural IMRT between November 2004 and May 2013. Pretreatment imaging, treatment plans, and posttreatment imaging were retrospectively reviewed to determine failure location(s). Failures were categorized as in-field (within the 90% isodose line), marginal (<90% and ≥50% isodose lines), out-of-field (outside the 50% isodose line), or distant. Results: The median follow-up was 24 months from diagnosis and the median time to in-field local failure from the end of RT was 10 months. Forty-three in-field local failures (64%) were found with a 1- and 2-year actuarial failure rate of 56% and 74%, respectively. For patients who underwent P/D versus those who received a partial pleurectomy or were deemed unresectable, the median time to in-field local failure was 14 months versus 6 months, respectively, with 1- and 2-year actuarial in-field local failure rates of 43% and 60% versus 66% and 83%, respectively (P=.03). There were 13 marginal failures (19%). Five of the marginal failures (38%) were located within the costomediastinal recess. Marginal failures decreased with increasing institutional experience (P=.04). Twenty-five patients (37%) had out-of-field failures. Distant failures occurred in 32 patients (48%). Conclusions: After hemithoracic pleural IMRT, local failure remains the dominant form of failure pattern. Patients treated with adjuvant hemithoracic pleural IMRT after P/D experience a significantly longer time to local and distant failure than patients treated with definitive pleural IMRT. Increasing experience and improvement in target delineation minimize the incidence of avoidable marginal failures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fat Composition Changes in Bone Marrow During Chemotherapy and Radiation Therapy

Purpose: To quantify changes in bone marrow fat fraction and determine associations with peripheral blood cell counts. Methods and Materials: In this prospective study, 19 patients received either highly myelotoxic treatment (radiation therapy plus cisplatin, 5-fluorouracil mitomycin C [FU/MMC], or cisplatin/5-FU/cetuximab) or less myelotoxic treatment (capecitabine-radiation therapy or no concurrent chemotherapy). Patients underwent MR imaging and venipuncture at baseline, midtreatment, and posttreatment visits. We performed mixed effects modeling of the mean proton density fat fraction (PDFF[%]) by linear time, treatment, and vertebral column region (lumbar [L]4-sacral [S]2 vs thoracic [T]10-L3 vs cervical[C]3-T9), while controlling for cumulative mean dose and other confounders. Spearman rank correlations were performed by white blood cell (WBC) counts versus the differences in PDFF(%) before and after treatment. Results: Cumulative mean dose was associated with a 0.43% per Gy (P=.004) increase in PDFF(%). In the highly myelotoxic group, we observed significant changes in PDFF(%) per visit within L4-S2 (10.1%, P<.001) and within T10-L3 (3.93%, P=.01), relative to the reference C3-T9. In the less myelotoxic group, we did not observe significant changes in PDFF(%) per visit according to region. Within L4-S2, we observed a significant difference between treatment groups in the change in PDFF(%) per visit (5.36%, P=.04). Rank correlations of the inverse log differences in WBC versus the differences in PDFF(%) overall and within T10-S2 ranged from 0.69 to 0.78 (P<.05). Rank correlations of the inverse log differences in absolute neutrophil counts versus the differences in PDFF(%) overall and within L4-S2 ranged from 0.79 to 0.81 (P<.05). Conclusions: Magnetic resonance imaging fat quantification is sensitive to marrow composition changes that result from chemoradiation therapy. These changes are associated with peripheral blood cell counts. This study supports a rationale for bone marrow-sparing treatment planning to reduce the risk of hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiobiological Determination of Dose Escalation and Normal Tissue Toxicity in Definitive Chemoradiation Therapy for Esophageal Cancer

Purpose: This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. Methods and Materials: Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm{sup 3}. A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5 Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA{sub 62.5}) was compared to a standard dose plan of 50 Gy/25 fractions (RA{sub 50}). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. Results: Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA{sub 50}) to 56.3% (RA{sub 62.5}), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA{sub 50}) versus 5.6% (RA{sub 62.5}) P<.001 and median lung NTCP 6.5% (RA{sub 50}) versus 7.5% (RA{sub 62.5}) P<.001. Conclusions: Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Modeling of CTV Motion and Deformation for IMRT of Early-Stage Rectal Cancer

Purpose: To derive and validate a statistical model of motion and deformation for the clinical target volume (CTV) of early-stage rectal cancer patients. Methods and Materials: For 16 patients, 4 to 5 magnetic resonance images (MRI) were acquired before each fraction was administered. The CTV was delineated on each MRI. Using a leave-one-out methodology, we constructed a population-based principal component analysis (PCA) model of the CTV motion and deformation of 15 patients, and we tested the model on the left-out patient. The modeling error was calculated as the amount of the CTV motion-deformation of the left-out-patient that could not be explained by the PCA model. Next, the PCA model was used to construct a PCA target volume (PCA-TV) by accumulating motion-deformations simulated by the model. A PCA planning target volume (PTV) was generated by expanding the PCA-TV by uniform margins. The PCA-PTV was compared with uniform and nonuniform CTV-to-PTV margins. To allow comparison, geometric margins were determined to ensure adequate coverage, and the volume difference between the PTV and the daily CTV (CTV-to-PTV volume) was calculated. Results: The modeling error ranged from 0.9 ± 0.5 to 2.9 ± 2.1 mm, corresponding to a reduction of the CTV motion-deformation between 6% and 60% (average, 23% ± 11%). The reduction correlated with the magnitude of the CTV motion-deformation (P<.001, R=0.66). The PCA-TV and the CTV required 2-mm and 7-mm uniform margins, respectively. The nonuniform CTV-to-PTV margins were 4 mm in the left, right, inferior, superior, and posterior directions and 8 mm in the anterior direction. Compared to uniform and nonuniform CTV-to-PTV margins, the PCA-based PTV significantly decreased (P<.001) the average CTV-to-PTV volume by 128 ± 20 mL (49% ± 4%) and by 35 ± 6 mL (20% ± 3.5%), respectively. Conclusions: The CTV motion-deformation of a new patient can be explained by a population-based PCA model. A PCA model-generated PTV significantly improved sparing of organs at risk compared to uniform and nonuniform CTV-to-PTV margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Cerebellum Radiation Dosimetry on Cognitive Outcomes in Children With Infratentorial Ependymoma

Purpose: Cognitive decline is a recognized effect of radiation therapy (RT) in children treated for brain tumors. The importance of the cerebellum and its contribution to cognition have been recognized; however, the effect of RT on cerebellum-linked neurocognitive deficits has yet to be explored. Methods and Materials: Seventy-six children (39 males) at a median 3.3 years of age (range, 1-17 years old) were irradiated for infratentorial ependymoma from 1997 to 2008. The total prescribed dose was 54 to 59.4 Gy administered to the postoperative tumor bed with 5- or 10-mm clinical target volume margin. Age-appropriate cognitive and academic testing was performed prior to the start of RT and was then repeated at 6 months and annually throughout 5 years. The anterior and posterior cerebellum and other normal brain volumes were contoured on postcontrast, T1-weighted postoperative magnetic resonance images registered to treatment planning computed tomography images. Mean doses were calculated and used with time after RT and other clinical covariates to model their effect on neurocognitive test scores. Results: Considering only the statistically significant rates in longitudinal changes for test scores and models that included mean dose, there was a correlation between mean infratentorial dose and intelligence quotient (IQ; −0.190 patients/Gy/year; P=.001), math (−0.164 patients/Gy/year; P=.010), reading (−0.137 patients/Gy/year; P=.011), and spelling scores (−0.147 patients/Gy/year; P=.012), where Gy was measured as the difference between the mean dose received by an individual patient and the mean dose received by the patient group. There was a correlation between mean anterior cerebellum dose and IQ scores (−0.116 patients/Gy/year; P=.042) and mean posterior cerebellum dose and IQ (−0.150 patients/Gy/year; P=.002), math (−0.120 patients/Gy/year; P=.023), reading (−0.111 patients/Gy/year; P=.012), and spelling (−0.117 patients/Gy/year; P=.015) scores. Conclusions: Sparing portions of the cerebellum should be considered in RT planning for children with infratentorial ependymoma because of the potential impact of radiation dose on cognitive function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of an Online Adaptive Plan-of-the-Day Protocol for Nonrigid Motion Management in Locally Advanced Cervical Cancer IMRT

Purpose: To evaluate the clinical implementation of an online adaptive plan-of-the-day protocol for nonrigid target motion management in locally advanced cervical cancer intensity modulated radiation therapy (IMRT). Methods and Materials: Each of the 64 patients had four markers implanted in the vaginal fornix to verify the position of the cervix during treatment. Full and empty bladder computed tomography (CT) scans were acquired prior to treatment to build a bladder volume-dependent cervix-uterus motion model for establishment of the plan library. In the first phase of clinical implementation, the library consisted of one IMRT plan based on a single model-predicted internal target volume (mpITV), covering the target for the whole pretreatment observed bladder volume range, and a 3D conformal radiation therapy (3DCRT) motion-robust backup plan based on the same mpITV. The planning target volume (PTV) combined the ITV and nodal clinical target volume (CTV), expanded with a 1-cm margin. In the second phase, for patients showing >2.5-cm bladder-induced cervix-uterus motion during planning, two IMRT plans were constructed, based on mpITVs for empty-to-half-full and half-full-to-full bladder. In both phases, a daily cone beam CT (CBCT) scan was acquired to first position the patient based on bony anatomy and nodal targets and then select the appropriate plan. Daily post-treatment CBCT was used to verify plan selection. Results: Twenty-four and 40 patients were included in the first and second phase, respectively. In the second phase, 11 patients had two IMRT plans. Overall, an IMRT plan was used in 82.4% of fractions. The main reasons for selecting the motion-robust backup plan were uterus outside the PTV (27.5%) and markers outside their margin (21.3%). In patients with two IMRT plans, the half-full-to-full bladder plan was selected on average in 45% of the first 12 fractions, which was reduced to 35% in the last treatment fractions. Conclusions: The implemented online adaptive plan-of-the-day protocol for locally advanced cervical cancer enables (almost) daily tissue-sparing IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot Scanning Proton Therapy for Malignancies of the Base of Skull: Treatment Planning, Acute Toxicities, and Preliminary Clinical Outcomes

Purpose: To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. Methods and Materials: From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. Results: Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. Conclusions: In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic Malignancies

Purpose: Intensity modulated proton therapy (IMPT) can improve dose conformality and better spare normal tissue over passive scattering techniques, but range uncertainties complicate its use, particularly for moving targets. We report our early experience with IMPT for thoracic malignancies in terms of motion analysis and management, plan optimization and robustness, and quality assurance. Methods and Materials: Thirty-four consecutive patients with lung/mediastinal cancers received IMPT to a median 66 Gy(relative biological equivalence [RBE]). All patients were able to undergo definitive radiation therapy. IMPT was used when the treating physician judged that IMPT conferred a dosimetric advantage; all patients had minimal tumor motion (<5 mm) and underwent individualized tumor-motion dose-uncertainty analysis and 4-dimensional (4D) computed tomographic (CT)-based treatment simulation and motion analysis. Plan robustness was optimized by using a worst-case scenario method. All patients had 4D CT repeated simulation during treatment. Results: IMPT produced lower mean lung dose (MLD), lung V{sub 5} and V{sub 20}, heart V{sub 40}, and esophageal V{sub 60} than did IMRT (P<.05) and lower MLD, lung V{sub 20}, and esophageal V{sub 60} than did passive scattering proton therapy (PSPT) (P<.05). D{sub 5} to the gross tumor volume and clinical target volume was higher with IMPT than with intensity modulated radiation therapy or PSPT (P<.05). All cases were analyzed for beam-angle-specific motion, water-equivalent thickness, and robustness. Beam angles were chosen to minimize the effect of respiratory motion and avoid previously treated regions, and the maximum deviation from the nominal dose-volume histogram values was kept at <5% for the target dose and met the normal tissue constraints under a worst-case scenario. Patient-specific quality assurance measurements showed that a median 99% (range, 95% to 100%) of the pixels met the 3% dose/3 mm distance criteria for the γ index. Adaptive replanning was used for 9 patients (26.5%). Conclusions: IMPT using 4D CT-based planning, motion management, and optimization was implemented successfully and met our quality assurance parameters for treating challenging thoracic cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

[{sup 18}F]FDG-PET Standard Uptake Value as a Metabolic Predictor of Bone Marrow Response to Radiation: Impact on Acute and Late Hematological Toxicity in Cervical Cancer Patients Treated With Chemoradiation Therapy

Purpose: To quantify the relationship between bone marrow (BM) response to radiation and radiation dose by using {sup 18}F-labeled fluorodeoxyglucose positron emission tomography [{sup 18}F]FDG-PET standard uptake values (SUV) and to correlate these findings with hematological toxicity (HT) in cervical cancer (CC) patients treated with chemoradiation therapy (CRT). Methods and Materials: Seventeen women with a diagnosis of CC were treated with standard doses of CRT. All patients underwent pre- and post-therapy [{sup 18}F]FDG-PET/computed tomography (CT). Hemograms were obtained before and during treatment and 3 months after treatment and at last follow-up. Pelvic bone was autosegmented as total bone marrow (BM{sub TOT}). Active bone marrow (BM{sub ACT}) was contoured based on SUV greater than the mean SUV of BM{sub TOT}. The volumes (V) of each region receiving 10, 20, 30, and 40 Gy (V{sub 10}, V{sub 20}, V{sub 30}, and V{sub 40}, respectively) were calculated. Metabolic volume histograms and voxel SUV map response graphs were created. Relative changes in SUV before and after therapy were calculated by separating SUV voxels into radiation therapy dose ranges of 5 Gy. The relationships among SUV decrease, radiation dose, and HT were investigated using multiple regression models. Results: Mean relative pre-post-therapy SUV reductions in BM{sub TOT} and BM{sub ACT} were 27% and 38%, respectively. BM{sub ACT} volume was significantly reduced after treatment (from 651.5 to 231.6 cm{sup 3}, respectively; P<.0001). BM{sub ACT} V{sub 30} was significantly correlated with a reduction in BM{sub ACT} SUV (R{sup 2}, 0.14; P<.001). The reduction in BM{sub ACT} SUV significantly correlated with reduction in white blood cells (WBCs) at 3 months post-treatment (R{sup 2}, 0.27; P=.04) and at last follow-up (R{sup 2}, 0.25; P=.04). Different dosimetric parameters of BM{sub TOT} and BM{sub ACT} correlated with long-term hematological outcome. Conclusions: The volumes of BM{sub TOT} and BM{sub ACT} that are exposed to even relatively low doses of radiation are associated with a decrease in WBC counts following CRT. The loss in proliferative BM SUV uptake translates into low WBC nadirs after treatment. These results suggest the potential of intensity modulated radiation therapy to spare BM{sub TOT} to reduce long-term hematological toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Replanning to Account for Lumpectomy Cavity Change in Sequential Boost After Whole-Breast Irradiation

Purpose: To evaluate the efficiency of standard image-guided radiation therapy (IGRT) to account for lumpectomy cavity (LC) variation during whole-breast irradiation (WBI) and propose an adaptive strategy to improve dosimetry if IGRT fails to address the interfraction LC variations. Methods and Materials: Daily diagnostic-quality CT data acquired during IGRT in the boost stage using an in-room CT for 19 breast cancer patients treated with sequential boost after WBI in the prone position were retrospectively analyzed. Contours of the LC, treated breast, ipsilateral lung, and heart were generated by populating contours from planning CTs to boost fraction CTs using an auto-segmentation tool with manual editing. Three plans were generated on each fraction CT: (1) a repositioning plan by applying the original boost plan with the shift determined by IGRT; (2) an adaptive plan by modifying the original plan according to a fraction CT; and (3) a reoptimization plan by a full-scale optimization. Results: Significant variations were observed in LC. The change in LC volume at the first boost fraction ranged from a 70% decrease to a 50% increase of that on the planning CT. The adaptive and reoptimization plans were comparable. Compared with the repositioning plans, the adaptive plans led to an improvement in target coverage for an increased LC case (1 of 19, 7.5% increase in planning target volume evaluation volume V{sub 95%}), and breast tissue sparing for an LC decrease larger than 35% (3 of 19, 7.5% decrease in breast evaluation volume V{sub 50%}; P=.008). Conclusion: Significant changes in LC shape and volume at the time of boost that deviate from the original plan for WBI with sequential boost can be addressed by adaptive replanning at the first boost fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Head-and-Neck Cancer: Potential to Improve Tumor Control and Late Toxicity

Purpose: To evaluate the potential benefit of 4π radiation therapy in recurrent, locally advanced, or metastatic head-and-neck cancer treated with stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty-seven patients with 29 tumors who were treated using SBRT were included. In recurrent disease (n=26), SBRT was delivered with a median 44 Gy (range, 35-44 Gy) in 5 fractions. Three patients with sinonasal mucosal melanoma, metastatic breast cancer, and primary undifferentiated carcinoma received 35 Gy, 22.5 Gy, and 40 Gy in 5 fractions, respectively. Novel 4π treatment plans were created for each patient to meet the objective that 95% of the planning target volume was covered by 100% of the prescription dose. Doses to organs at risk (OARs) and 50% dose spillage volumes were compared against the delivered clinical SBRT plans. Local control (LC), late toxicity, tumor control probability (TCP), and normal tissue complication probability were determined. Results: Using 4π plans, mean/maximum doses to all OARs were reduced by 22% to 89%/10% to 86%. With 4π plans, the 50% dose spillage volume was decreased by 33%. Planning target volume prescription dose escalation by 10 Gy and 20 Gy were achieved while keeping doses to OARs significantly improved or unchanged from clinical plans, except for the carotid artery maximum dose at 20-Gy escalation. At a median follow-up of 10 months (range, 1-41 months), crude LC was 52%. The 2-year LC of 39.2% approximated the predicted mean TCP of 42.2%, which increased to 45.9% with 4π plans. For 10-Gy and 20-Gy dose escalation, 4π plans increased TCP from 80.1% and 88.1% to 85.5% and 91.4%, respectively. The 7.4% rate of grade ≥3 late toxicity was comparable to the predicted 5.6% mean normal tissue complication probability for OARs, which was significantly reduced by 4π planning at the prescribed and escalated doses. Conclusions: 4π plans may allow dose escalation with significant and consistent improvements in critical organ sparing, tumor control, and coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Online/Offline Image Guidance/Adaptation Approaches for Prostate Cancer Radiation Therapy

Purpose: To evaluate online/offline image-guided/adaptive treatment techniques for prostate cancer radiation therapy with daily cone-beam CT (CBCT) imaging. Methods and Materials: Three treatment techniques were evaluated retrospectively using daily pre- and posttreatment CBCT images on 22 prostate cancer patients. Prostate, seminal vesicles (SV), rectal wall, and bladder were delineated on all CBCT images. For each patient, a pretreatment intensity modulated radiation therapy plan with clinical target volume (CTV) = prostate + SV and planning target volume (PTV) = CTV + 3 mm was created. The 3 treatment techniques were as follows: (1) Daily Correction: The pretreatment intensity modulated radiation therapy plan was delivered after online CBCT imaging, and position correction; (2) Online Planning: Daily online inverse plans with 3-mm CTV-to-PTV margin were created using online CBCT images, and delivered; and (3) Hybrid Adaption: Daily Correction plus an offline adaptive inverse planning performed after the first week of treatment. The adaptive plan was delivered for all remaining 15 fractions. Treatment dose for each technique was constructed using the daily posttreatment CBCT images via deformable image registration. Evaluation was performed using treatment dose distribution in target and critical organs. Results: Treatment equivalent uniform dose (EUD) for the CTV was within [85.6%, 100.8%] of the pretreatment planned target EUD for Daily Correction; [98.7%, 103.0%] for Online Planning; and [99.2%, 103.4%] for Hybrid Adaptation. Eighteen percent of the 22 patients in Daily Correction had a target dose deficiency >5%. For rectal wall, the mean ± SD of the normalized EUD was 102.6% ± 2.7% for Daily Correction, 99.9% ± 2.5% for Online Planning, and 100.6% ± 2.1% for Hybrid Adaptation. The mean ± SD of the normalized bladder EUD was 108.7% ± 8.2% for Daily Correction, 92.7% ± 8.6% for Online Planning, and 89.4% ± 10.8% for Hybrid Adaptation. Conclusions: Both Online Planning and Hybrid Adaptation can achieve comparable target coverage and normal tissue sparing and are superior to the Daily Correction technique. The Daily Correction technique using a 3-mm target margin in the pretreatment plan is not appropriate to compensate for residual variations in CBCT image-guided prostate cancer radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Toxicity in Patients Treated With Postoperative Proton Therapy for Locally Advanced Breast Cancer

Purpose: To report dosimetry and early toxicity data in breast cancer patients treated with postoperative proton radiation therapy. Methods and Materials: From March 2013 to April 2014, 30 patients with nonmetastatic breast cancer and no history of prior radiation were treated with proton therapy at a single proton center. Patient characteristics and dosimetry were obtained through chart review. Patients were seen weekly while on treatment, at 1 month after radiation therapy completion, and at 3- to 6-month intervals thereafter. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Frequencies of toxicities were tabulated. Results: Median dose delivered was 50.4 Gy (relative biological equivalent [RBE]) in 5 weeks. Target volumes included the breast/chest wall and regional lymph nodes including the internal mammary lymph nodes (in 93%). No patients required a treatment break. Among patients with >3 months of follow-up (n=28), grade 2 dermatitis occurred in 20 patients (71.4%), with 8 (28.6%) experiencing moist desquamation. Grade 2 esophagitis occurred in 8 patients (28.6%). Grade 3 reconstructive complications occurred in 1 patient. The median planning target volume V95 was 96.43% (range, 79.39%-99.60%). The median mean heart dose was 0.88 Gy (RBE) [range, 0.01-3.20 Gy (RBE)] for all patients, and 1.00 Gy (RBE) among patients with left-sided tumors. The median V20 of the ipsilateral lung was 16.50% (range, 6.1%-30.3%). The median contralateral lung V5 was 0.34% (range, 0%-5.30%). The median maximal point dose to the esophagus was 45.65 Gy (RBE) [range, 0-65.4 Gy (RBE)]. The median contralateral breast mean dose was 0.29 Gy (RBE) [range, 0.03-3.50 Gy (RBE)]. Conclusions: Postoperative proton therapy is well tolerated, with acceptable rates of skin toxicity. Proton therapy favorably spares normal tissue without compromising target coverage. Further follow-up is necessary to assess for clinical outcomes and cardiopulmonary toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of [{sup 11}C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Predictors of Radiation-Induced Vaginal Stenosis After Pelvic Radiation Therapy for Rectal and Anal Cancer

Purpose: Although vaginal stenosis (VS) is a recognized toxicity in women who receive pelvic radiation therapy (RT), the relationship between RT dose and the volume and extent of toxicity has not been analyzed. We modeled this relationship to identify predictors of VS. Methods and Materials: We evaluated 54 women, aged 29 to 78 years, who underwent pelvic RT for rectal or anal cancer during 2008 to 2011 and were enrolled in a prospective study evaluating vaginal dilator use. Maximum dilator size was measured before RT (baseline) and 1 month and 12 months after RT. Dilator use was initiated at 1 month. The difference (D) in dilator size before and after RT was recorded. Those with D ≤−1 were classified as having VS (n=35); those with D ≥0 were classified as having no VS (n=19 at 1 month). Dose-volume parameters were extracted, and the generalized equivalent uniform dose (gEUD) was used to build a predictive model. Results: The mean vaginal doses were 50.0 Gy and 36.8 Gy for anal and rectal cancer patients, respectively. One month after RT, a gEUD model using a wide range of a values suggests that sparing of vaginal volume to a low dose may be important. When gEUD (a = −1) was <35 Gy and the mean vaginal dose was <43 Gy, severe VS was reduced (P=.02). A 1-year analysis suggests increasingly negative D values with increasing mean dose. However, patients with compliance <40% were more likely to have toxicity. Conclusions: Vaginal stenosis is influenced by multiple RT dose-volume characteristics. Mean dose and gEUD constraints together may reduce the risk of severe VS. Patients receiving higher mean vaginal doses should have greater compliance with dilator therapy to minimize risk of toxicity. Further validation with independent datasets is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗