Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

NSTX-U Digital Coil Protection System Software Detailed Design

The National Spherical Torus Experiment (NSTX) currently uses a collection of analog signal processing solutions for coil protection. Part of the NSTX Upgrade (NSTX-U) entails replacing these analog systems with a software solution running on a conventional computing platform. The new Digital Coil Protection System (DCPS) will replace the old systems entirely, while also providing an extensible framework that allows adding new functionality as desired.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pairwise Sequence Alignment Library

Vector extensions, such as SSE, have been part of the x86 CPU since the 1990s, with applications in graphics, signal processing, and scientific applications. Although many algorithms and applications can naturally benefit from automatic vectorization techniques, there are still many that are difficult to vectorize due to their dependence on irregular data structures, dense branch operations, or data dependencies. Sequence alignment, one of the most widely used operations in bioinformatics workflows, has a computational footprint that features complex data dependencies. The trend of widening vector registers adversely affects the state-of-the-art sequence alignment algorithm based on striped data layouts. Therefore, a novel SIMD implementation of a parallel scan-based sequence alignment algorithm that can better exploit wider SIMD units was implemented as part of the Parallel Sequence Alignment Library (parasail). Parasail features: Reference implementations of all known vectorized sequence alignment approaches. Implementations of Smith Waterman (SW), semi-global (SG), and Needleman Wunsch (NW) sequence alignment algorithms. Implementations across all modern CPU instruction sets including AVX2 and KNC. Language interfaces for C/C++ and Python.

Jeff Daily, PNNL↗

Guided wave opto-acoustic device

The various technologies presented herein relate to various hybrid phononic-photonic waveguide structures that can exhibit nonlinear behavior associated with traveling-wave forward stimulated Brillouin scattering (forward-SBS). The various structures can simultaneously guide photons and phonons in a suspended membrane. By utilizing a suspended membrane, a substrate pathway can be eliminated for loss of phonons that suppresses SBS in conventional silicon-on-insulator (SOI) waveguides. Consequently, forward-SBS nonlinear susceptibilities are achievable at about 3000 times greater than achievable with a conventional waveguide system. Owing to the strong phonon-photon coupling achievable with the various embodiments, potential application for the various embodiments presented herein cover a range of radiofrequency (RF) and photonic signal processing applications. Further, the various embodiments presented herein are applicable to applications operating over a wide bandwidth, e.g. 100 MHz to 50 GHz or more.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for noninvasive determination of acoustic properties of fluids inside pipes

A method for determining the composition of fluids flowing through pipes from noninvasive measurements of acoustic properties of the fluid is described. The method includes exciting a first transducer located on the external surface of the pipe through which the fluid under investigation is flowing, to generate an ultrasound chirp signal, as opposed to conventional pulses. The chirp signal is received by a second transducer disposed on the external surface of the pipe opposing the location of the first transducer, from which the transit time through the fluid is determined and the sound speed of the ultrasound in the fluid is calculated. The composition of a fluid is calculated from the sound speed therein. The fluid density may also be derived from measurements of sound attenuation. Several signal processing approaches are described for extracting the transit time information from the data with the effects of the pipe wall having been subtracted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and apparatus for detecting dilute concentrations of radioactive xenon in samples of xenon extracted from the atmosphere

A method and apparatus for measuring the concentrations of radioxenon isotopes in a gaseous sample wherein the sample cell is surrounded by N sub-detectors that are sensitive to both electrons and to photons from radioxenon decays. Signal processing electronics are provided that can detect events within the sub-detectors, measure their energies, determine whether they arise from electrons or photons, and detect coincidences between events within the same or different sub-detectors. The energies of detected two or three event coincidences are recorded as points in associated two or three-dimensional histograms. Counts within regions of interest in the histograms are then used to compute estimates of the radioxenon isotope concentrations. The method achieves lower backgrounds and lower minimum detectable concentrations by using smaller detector crystals, eliminating interference between double and triple coincidence decay branches, and segregating double coincidences within the same sub-detector from those occurring between different sub-detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Compact radiation detector

An apparatus for detecting radiation is provided. In embodiments, at least one sensor is disposed on a surface of a wafer-like substrate. At least one sensor medium is fixed relative to the substrate, optically or electrically coupled to the sensor, and separated from the sensor by no more than the substrate thickness. An electronic signal-processing circuit is connected to the sensor and configured to produce an output when the sensor is stimulated by a product of an interaction between the sensor medium and impinging radiation. The sensor is configured to collect, from the sensor medium, charge and/or light produced within the sensor medium by interactions with impinging radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guided wave opto-acoustic device

The various technologies presented herein relate to various hybrid phononic-photonic waveguide structures that can exhibit nonlinear behavior associated with traveling-wave forward stimulated Brillouin scattering (forward-SBS). The various structures can simultaneously guide photons and phonons in a suspended membrane. By utilizing a suspended membrane, a substrate pathway can be eliminated for loss of phonons that suppresses SBS in conventional silicon-on-insulator (SOI) waveguides. Consequently, forward-SBS nonlinear susceptibilities are achievable at about 3000 times greater than achievable with a conventional waveguide system. Owing to the strong phonon-photon coupling achievable with the various embodiments, potential application for the various embodiments presented herein cover a range of radiofrequency (RF) and photonic signal processing applications. Further, the various embodiments presented herein are applicable to applications operating over a wide bandwidth, e.g. 100 MHz to 50 GHz or more.

Rakich, Peter Thomas↗

Nondestructive Testing Research and Development Efforts at Argonne National Laboratory—An Overview

The Nuclear Engineering (NE) Division of Argonne National Laboratory (ANL) has been involved for many years with research and development efforts associated with the nondestructive testing/evaluation (NDT/NDE) of critical components and structures in power generation (nuclear and fossil plants), aerospace, defense, homeland security, medical, and scientific applications. A wide range of NDT methods including electromagnetic, thermal, radiographic, acoustic and ultrasonic methods have been used for a wide range of material evaluation applications. Argonne’s expertise in analytical and numerical modeling of thermal, acoustic and electromagnetic interaction with complex media as well as advanced signal processing and data analysis have been utilized extensively for NDT applications. Three active areas of research, all in connection with NDT of materials and systems utilized in nuclear energy applications, are discussed in detail in this paper.

Eddy current testing↗

Acoustic camera

Apparatus for generating accurate 3-dimensional images of objects immersed in liquids including optically opaque liquids which may also have significant sound attenuation, is described. Sound pulses are caused to impinge on the object, and the time-of-flight of the reflected sound is used to create a 3-dimensional image of the object in almost real-time. The apparatus is capable of creating images of objects immersed in fluids that are optically opaque and have high sound attenuation at resolutions less than about 1 mm. The apparatus may include a piezoelectric transducer for generating the acoustic pulses; a high-density polyethylene compound acoustic lens, a 2-dimensional segmented piezoelectric detecting array positioned behind the lens for receiving acoustic pulses reflected by the object, the electric output of which is directed to digital signal processing electronics for generating the image.

47 OTHER INSTRUMENTATION↗

Continuous Light Absorption Photometer (CLAP) Final Campaign Report

The Continuous Light Absorption Photometer (CLAP) measures the aerosol absorption of radiation at three visible wavelengths; 461, 522 and 653 nanometers (nm). Data from this measurement is used in radiative forcing calculations, atmospheric heating rates, and as a prediction of the amount of equivalent black carbon in atmospheric aerosol and in models of aerosol semi-direct forcing. Aerosol absorption measurements are essential to modeling the energy balance of the atmosphere. Current direct measurements of wavelength-dependent aerosol absorption include filter-based techniques such as CLAP, the aethelometer and particle soot absorption photometer (PSAP), and the in-situ, absorption of aerosols with the photoacoustic absorption spectrometer (PAAS). The laser instability, high noise as well as high cost of the PAAS make it difficult to deploy for long-term measurements. Filterbased absorption techniques are inexpensive, robust, and easy to operate, yet have known problems with secondary scattering and liquid aerosols spreading into the filter matrix. The current PSAP and aethelometer measurements have problems with water condensation on the filter and ambiguous internal signal processing, which make them difficult to evaluate

Aerosol Observing System, ARM Mobile Facility, Sou↗

Tracking of moving radioactive sources

A system for detecting unsecured nuclear materials. Whereas current portal monitors rely in part on physical prominence to deter materials from entering the country, their application at intra-modal transport points may actually serve to divert the movement of nuclear materials rather than aid in interception. A flexible and low-profile system has been developed for unobtrusive detection and tracking of radioactive sources in transit suited for deployment at traffic choke points such as rest stops, toll collection plazas, truck stops, and bridges. The system includes gamma radiation detectors, networking for linking these detectors, signal processing algorithms, and a central processing and control unit.

Klann, Raymond↗

FERMILAB PIP-II BOOSTER LLRF UPGRADE

A proposed upgrade to the Fermilab Booster synchrotron is presented. A new LLRF system is required for interfac-ing to the PIP-II Linac that is currently under construction. The present feedback system has legacy analog hardware interleaved with updated digital components for control. A prototype of a new digital system using an FPGA controller is presented along with the RF hardware to handle up and down conversion of RF signals. A prototype FPGA con-troller is implemented using an Altera Cyclone V System on Chip, with 14-bit ADC’s and DAC’s running at 66 MHz. The controller theory and implementation are described in this paper, along with a description of the RF signal processing scheme.

43 PARTICLE ACCELERATORS↗

Spatiotemporal Pattern Recognition in the PMU Signals in the WECC system

Phasor measurement unit (PMU) data has been used by multiple power system applications, including state estimation, post event analysis, oscillation detection, model validation, and many others. Still, due to its big data nature and availability to general research institutions, comprehensive understanding of the spatiotemporal patterns and underlying mechanisms are incomplete. This study applies a set of signal processing and machine learning approaches aiming at deciphering the characteristic behaviors of multiple phasor measurement units (PMUs) attributes (e.g., voltage, frequency, rate of change of frequency, phase angle), including their auto-correlation, cross-dependence, similarities and discrepancies across units and temporal scales, and distributions of anomalies and their linkages to potential external factors such as weather events. Data analytics are applied to PMUs from the U.S. Western Electricity Coordinating Council (WECC) system. The PMU measurements, recorded events, outages, and weather extremes are all from real world datasets. The findings from the study and mechanistic understanding of the PMU dynamics help provide guidance on system control or preventing blackouts. The derived metrics can be directly used for adjusting or filtering simulated PMU data used for advanced algorithm development.

Hou, Zhangshuan↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) – Performance Characterization

Design and performance of a digital signal processing platform for enhancing off-the-shelf voltage and current sensors are presented. The platform was developed for enabling advanced distribution grid applications with existing low-cost sensors. This digital sensor system leverages a variety of off-the-shelf voltage and current sensing technologies, analog-to-digital conversion, and sensor correction algorithms to yield more accurate and reliable digital measurements that support a multitude of applications and use cases. Sample performance and accuracy results are provided, including measurements at power frequency and higher harmonics. The system extends the native performance of the medium voltage sensors used in the system, for example, broadening measurement bandwidth beyond a few kHz, appropriate for measuring switching surges and harmonics on medium voltage distribution systems. The digital sensor system is installed and characterized in the field with a high-bandwidth optical calibration system to determine site-dependent calibration and performance issues.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmitters for animals and methods for transmitting from animals

Animal transmitters are provided that can include: a transducer configured to transmit a signal; process circuitry coupled to the transducer; and an energy harvesting element coupled to the process circuitry. Animals having a transmitter coupled thereto are also provided with the transmitter including an energy harvesting element in operational alignment with the animal's musculoskeletal system. Methods for transmitting the location of an animal are also provided with the methods including: coupling a transmitter powered by an energy harvesting element to the animal; and monitoring the transmissions of the transmitter.

Deng, Z. Daniel↗

A Vector Control and Data Acquisition System for the Multicavity LLRF System for Cryomodule1 at Fermilab

A LLRF control and data acquisition system for the 8-cavity Cryo-Module 1 at the ILCTA has been implemented using three , 33-channel MFC boards in a VXI mainframe. One card each is dedicated for the cavity probes for vector control , forward power and reverse power measurements. The system is scalable to 24 cavities or more with the commissioning of Cryo-Modules 2 and 3 without additional hardware. The signal processing and vector control of the cavities is implemented in a FPGA and a high speed data acquisition system with upto 100 channels stores data in external SDRAM memory. The system supports both pulsed and CW modes with a pulse rate of 5Hz. Acquired data is transferred between pulses to auxiliary systems such as the piezo controller through the slot0 controller. The design of the system is described and the performance of the vector control system is evaluated.

43 PARTICLE ACCELERATORS↗

Cavity Control Algorithms

A LLRF system typically incorporates either a heterodyne or direct sampling technique, followed by fast ADCs, then an FPGA and finally a transmitting DAC. An ultra low jitter clock system (sub-picoseconds) is required for fast sampling ADCs/DACs to preserve necessary signal to noise ratio. As a result we have universal hardware able to accommodate a variety of firmware for the specific application. The cavity control algorithm, greatly released from hardware constraints, can be developed much faster for very specific and demanding requirements. Based on the type of the accelerator (Pulsed, CW) and nature of the cavity field disturbances ( Lorentz Forces, microphonics, helium drift, temperature drift, beam load etc.) one can select a suitable controller. A generic PID feedback mechanism may be the first and easiest choice for most cases, while Kalman filtering or Adaptive control require more involved system modeling, and extra computational effort. A pulse system usually requires an additional feed forward mechanism while for a CW machine an SEL (Self Excited Loop) can be an excellent approach. Selecting the correct gains for effective control can be challenging and it depends on the beam energy spread requirements, system stability and control system scheme ( I&Q, Amplitude & Phase, SEL). Finally, the computational capability of the FPGA allows it to incorporate digital signal processing (for instance CIC(Cascaded Integrator-Comb filter), tunable IIR) as well as CORDIC ( COordinate Rotation DIgital Computer) to calculate trigonometric quantities. In this talk, a summary of popular algorithms is presented along with an example of the Jefferson Lab 12 GeV cavity field control system.

Plawski, Tomasz↗