Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Behavioral and Physiological Analyses of Parturition In Pregnant Rats: Insights Derived from Intrauterine Telemetry

During labor and birth, fetuses are exposed to considerable physical stimulation associated with labor contractions and expulsion from the womb These forces are important for the neonates' adaptation to tile extrauterine environment. To further our understanding of the relationship between labor and postpartum outcome, we developed a novel method for measuring intrauterine pressure (IUP) in freely-moving, late pregnant and parturient rats that enables us to make precise, reliable measures of the forces experienced by rat fetuses during parturition. A small (1.25 x 4 cm) telemetric blood pressure sensor was fitted within a fluid-filled balloon, similar in size to a full term rat fetus. On Gestational day (G) 19 of the rats' 22/23 day pregnancy, each dam was anesthetized and a balloon/sensor unit surgically implanted within the uterus following removal of two fetuses. Comparisons were made between sensor-implanted dams (IMPL) and a control conditions: 1) LAP-R, laparotomy with two fetuses removed or 2) LAP-NR, laparotomy with no fetuses removed. IUP signals were sampled at 10s intervals from the IMPL dams during labor and birth. Dams in all three conditions were videorecorded enabling us to analyze the effect of the implant on behavioral expressions of parturition. Contraction frequency, duration, pup-to-pup birth intervals and pup-oriented activities of the dams measured from one hour prior to the first pup birth until the birth of the third pup were unaffected by the sensor implant. Intrauterine telemetry of freely-moving dams offers significant advantages over conventional hardwired IUP measurement techniques. These findings establish and validate intrauterine telemetry as a reliable, non-invasive technique for quantifying pressures associated with parturition.

Villareal, J.↗

POINT: Partially Observable Imitation Network for Traffic Signal Control

Smart traffic signals bring together transportation infrastructure and advance technologies to improve the mobility and efficiency of urban transportation network. Adaptive traffic signal control studies can be categorized into modeling-based approaches and learning-based approaches. In order to take advantages of these two systems, this study developed an offline-online combined Partial Observable Imitation Network for Traffic signal control (POINT). In the offline system, the traffic signal timing optimization problem was formulated as a Mixed Integer Nonlinear Programming (MINLP) given complete traffic information, i.e., second-by-second speeds and locations of all vehicles. Furthermore, the objective of MINLP is to minimize total travel delays considering individual vehicle trajectories under Connected Vehicle (CV) environment. The calculated optimal solutions under various traffic conditions were considered as the ”expert” decisions. In the online system, an imitation neural network model was developed to learn the ”expert” signal plans generated from offline system. Given partial observable traffic conditions in real time, e.g., the aggregate-level of traffic volume, the POINT model can compute the signal timing parameters in the online system. The numerical results demonstrated that the proposed method outperformed other state-of-the-art signal control method under high and unbalanced traffic demand levels in terms of reducing travel delays and queue length.

33 ADVANCED PROPULSION SYSTEMS↗

Optical parametric amplification of spectrally incoherent pulses

The optical parametric amplification of spectrally incoherent signals is analyzed and simulated using a set of normalized equations describing phase-matched three-wave nonlinear mixing. Varying the amplifier’s properties and the seeding conditions reveals different amplification regimes. In particular, the relative temporal walk-off of the signal, idler, and pump has a strong impact on the temporal and spectral properties of the amplified signal. The amplification efficiency for spectrally incoherent signals is not significantly lower than that of a coherent monochromatic signal, provided that the phase-matching bandwidth is sufficient. Here, the results obtained with the normalized set of equations are in good agreement with simulations based on the full description of the crystals’ dispersion for high-gain LBO and BBO preamplifiers and a low-gain DKDP power amplifier.

47 OTHER INSTRUMENTATION↗

Flame Imaging System

A system for imaging a flame and the background scene is discussed. The flame imaging system consists of two charge-coupled-device (CCD) cameras. One camera uses a 800 nm long pass filter which during overcast conditions blocks sufficient background light so the hydrogen flame is brighter than the background light, and the second CCD camera uses a 1100 nm long pass filter, which blocks the solar background in full sunshine conditions such that the hydrogen flame is brighter than the solar background. Two electronic viewfinders convert the signal from the cameras into a visible image. The operator can select the appropriate filtered camera to use depending on the current light conditions. In addition, a narrow band pass filtered InGaAs sensor at 1360 nm triggers an audible alarm and a flashing LED if the sensor detects a flame, providing additional flame detection so the operator does not overlook a small flame.

Barnes, Heidi L.↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6A1-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 kHz to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. Methods used to reduce the effects of extraneous noises (i.e., machine noises, fretting) are described. A frequency spectrum analyzer was used to characterize the emissions and to evaluate methods used to acquire the signals (i.e., transducer location, bandwidth selection). The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions.

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6Al-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

On optimal soft-decision demodulation

A necessary condition is derived for optimal J-ary coherent demodulation of M-ary (M greater than 2) signals. Optimality is defined as maximality of the symmetric cutoff rate of the resulting discrete memoryless channel. Using a counterexample, it is shown that the condition derived is generally not sufficient for optimality. This condition is employed as the basis for an iterative optimization method to find the optimal demodulator decision regions from an initial 'good guess'. In general, these regions are found to be bounded by hyperplanes in likelihood space; the corresponding regions in signal space are found to have hyperplane asymptotes for the important case of additive white Gaussian noise. Some examples are presented, showing that the regions in signal space bounded by these asymptotic hyperplanes define demodulator decision regions that are virtually optimal.

Lee, L.-N.↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Can Zn isotopes in sediments record past eutrophication of freshwater lakes? A pilot study at Lake Baldegg (Switzerland)

In this study, the speciation and isotopic composition of Zn were traced across the sediments of a freshwater lake that experienced one hundred years of strong eutrophication, in order to assess the potential of sedimentary Zn isotopes to record such an environmental disturbance. Here, the results indicate that the sedimentary Zn isotope signal varied with the change from pre-eutrophic to eutrophic conditions in the investigated lake. The average δ 66 Zn JMC value of the dominantly allochthonous lithogenic sediments deposited during the pre-eutrophic period was +0.27‰ ±0.05‰ (i.e. similar to the δ 66 Zn JMC value of +0.28‰ ±0.05‰ proposed for Bulk Silicate Earth), while enhanced autochthonous biochemical sedimentation during the eutrophic period resulted in significantly lower δ 66 Zn JMC values down to +0.04‰ ±0.06‰. Synchrotron-based X-ray absorption spectroscopy data revealed a concomitant change in Zn speciation from a dominant fraction of Zn in clay minerals during the pre-eutrophic period to a major fraction of Zn in ZnS during the eutrophic period. A linear regression relating the sedimentary Zn isotope signal to the fraction of Zn in ZnS indicated δ 66 Zn JMC values of +0.27‰ ±0.06‰ and 0.00‰ ±0.08‰ for Zn in clay minerals and in ZnS, respectively. The enrichment of light Zn in ZnS in the eutrophic sediments is tentatively attributed to enhanced biological uptake of light Zn in the water column, which resulted in an enhanced flux of organic-bound Zn towards the sediments and further transformation of organic Zn into ZnS upon biomass mineralization during early diagenesis. This hypothesis is in agreement with the fractionation towards lighter Zn reported for both biological uptake of Zn and ZnS precipitation. The results of this study emphasize the potential of sedimentary Zn isotopes to register past eutrophic periods in freshwater lakes, and thus to serve as a probe of paleo-environmental conditions and/or past land use at the catchment scale.

58 GEOSCIENCES↗

Behavior of the Cadmium Pool in the INL Mk-IV Electrorefiner

The Mk-IV electrorefiner has been in service since 1996 recovering uranium from spent fuels from the Experimental Breeder Rector II and Fast Flux Test Facility sodium-cooled fast reactors. The electrorefiner vessel includes a cadmium pool beneath the salt. The voltage signal between the cadmium pool and reference electrode (Ag/AgCl type) provides information about the chemical condition of the cadmium pool with respect to uranium and zirconium saturation. This information is used to guide process control and sampling decisions. This paper describes how the voltage signal is related to chemistry by the analyses of data from Mk-IV operations and confirmatory experimentation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Particle size and velocity measurement in flames by laser anemometer

Simultaneous droplet size and velocity measurements by a particle counting Laser Doppler Anemometer (LDA) in kerosene fuel sprays under burning and non-burning conditions are presented. Particle sizes are derived from pulse height analysis of the mean LDA signals and velocities are simultaneously determined by measuring Doppler shift frequencies. The measurements show that droplet velocity is a function of droplet diameter for burning and non-burning conditions, and spatially averaged size distributions are derived from velocity data. A comparison of results obtained under burning and non-burning conditions show changes in size distribution due to preferential vaporization of small droplets, acceleration due to thermal expansion of gases, and corresponding changes in droplet momentum.

Chigier, N. A.↗

In-Situ Measurement of the Height of Condensed Water in Steam Pipes with Dynamic Flow

A method based on the use of enhanced filtered Hilbert envelope of the wave signal was developed in order to monitor the height of condensed water through the wall of steam pipes having dynamic flow conditions. A prototype testbed was designed and fabricated in this study to simulate the dynamic flow conditions including the air stream flowing above the water and bubble induced disturbance. A dual-transducer was used to perform the test as a basis for the multiple transducers system to facilitate the detectability and reliability for long term monitoring of the condensed water height in dynamic conditions. The results demonstrated that the method of measuring the water height using multiple-transducer system employing the developed novel signal processing technique is an efficient and accurate tool for practical applications.

water level in pipe↗

Pseudo-noise test set for communication system evaluation

A test set for communications systems is described which includes a pseudo noise sequence generator providing a test signal that is fed to a pair of signal channels. The first channel includes a spectrum shaping filter and a conditioning amplifier. The second channel includes a variable delay circuit, a spectrum shaping filter matched to the first filter, and an amplifier. The output of the first channel was applied to the system under test. The output of the system and the output of the second channel are compared to determine the degree of distortion suffered by the test signal due to the communications system.

Wallace, G. R.↗

Low-Shear modeled microgravity alters the Salmonella enterica serovar typhimurium stress response in an RpoS-independent manner

We have previously demonstrated that low-shear modeled microgravity (low-shear MMG) serves to enhance the virulence of a bacterial pathogen, Salmonella enterica serovar Typhimurium. The Salmonella response to low-shear MMG involves a signaling pathway that we have termed the low-shear MMG stimulon, though the identities of the low-shear MMG stimulon genes and regulatory factors are not known. RpoS is the primary sigma factor required for the expression of genes that are induced upon exposure to different environmental-stress signals and is essential for virulence in mice. Since low-shear MMG induces a Salmonella acid stress response and enhances Salmonella virulence, we reasoned that RpoS would be a likely regulator of the Salmonella low-shear MMG response. Our results demonstrate that low-shear MMG provides cross-resistance to several environmental stresses in both wild-type and isogenic rpoS mutant strains. Growth under low-shear MMG decreased the generation time of both strains in minimal medium and increased the ability of both strains to survive in J774 macrophages. Using DNA microarray analysis, we found no evidence of induction of the RpoS regulon by low-shear MMG but did find that other genes were altered in expression under these conditions in both the wild-type and rpoS mutant strains. Our results indicate that, under the conditions of these studies, RpoS is not required for transmission of the signal that induces the low-shear MMG stimulon. Moreover, our studies also indicate that low-shear MMG can be added to a short list of growth conditions that can serve to preadapt an rpoS mutant for resistance to multiple environmental stresses.

Non-NASA Center↗

Sorption‐Induced Fiber Optic Plasmonic Gas Sensing via Small Grazing Angle of Incidence

Abstract Sensing technologies based on plasmonic nanomaterials are of interest for various chemical, biological, environmental, and medical applications. In this work, an incorporation strategy of colloidal plasmonic nanoparticles (pNPs) in microporous polymer for realizing distinct sorption‐induced plasmonic sensing is reported. This approach is demonstrated by introducing tin‐doped indium oxide pNPs into a polymer of intrinsic microporosity (PIM‐1). The composite film (pNPs‐polymer) provides distinct and tunable optical features on the fiber optic (FO) platform that can be used as a signal transducer for gas sensing (e.g., CO 2 ) under atmospheric conditions. The resulting pNPs‐polymer composite demonstrates high sensitivity response on FO in the evanescent field configuration, provided by the dramatic response of modes above the total‐internal‐reflection angle. Furthermore, by varying the pNPs content in the polymer matrix, the optical behavior of the pNPs‐polymer composite film can be tuned to affect the operational wavelength by over several hundred nanometers and the sensitivity of the sensor in the near‐infrared range. It is also shown that the pNPs‐polymer composite film exhibits remarkable stability over a period of more than 10 months by mitigating the physical aging issue of the polymer.

Kim, Ki‐Joong↗

Colocalized Raman spectroscopy – scanning electrochemical microscopy investigation of redox flow battery dialkoxybenzene redoxmer degradation pathways

Non-aqueous redox flow batteries offer high voltages for grid-level energy storage technologies. However, decomposition of the redoxmers - redox-active molecules that make up the anolyte and catholyte in the negative and positive cell compartments - is an important challenge to overcome for long-term storage. Here, we present a spectroelectrochemical study of the catholyte candidate 2,3-dimethyl-1,4-dialkoxybenzene (C7) and its decomposition mechanisms in the presence of a model nucleophilic base, pyridine. We utilize colocalized Raman microscopy and scanning electrochemical microscopy (Raman-SECM) to quantify the chemical rates of decom-position and qualitatively identify the reaction intermediates and products. A detailed study on how the Raman-SECM parameters (electrode distance, substrate electrode, and laser focal height) influence the Raman signal of the charged catholyte C7 ∙+ is presented. Using optimized conditions, we monitored the deprotonation of C7 ∙+ via Raman spectroscopy and the subsequent hydrogen abstraction from solvent molecules to regenerate C7 via electrochemistry. Finite element modeling was used to fit electrochemical and spectroscopic data, quantifying the deprotonation rates as k dep = 2000 and 700 L mol -1 s -1 and abstraction rates as k abs = 0.5 and 0.2 s - 1 in propylene carbonate and acetonitrile solvents, respectively. Our results show the value of spatiotemporal reso-lution in evaluating the chemical and electrochemical behavior of materials for redox flow batteries.

25 ENERGY STORAGE↗

Towards the usage of quarry blasts as an active seismic source for subsurface characterization and imaging

SUMMARY Active or man-made seismic sources are often used to delineate subsurface geological structures via seismic imaging techniques. Although conventional controlled seismic sources have provided high-resolution subsurface images, the high cost of data acquisition necessitates improved use of cheaper alternative seismic sources for subsurface imaging, such as traffic noise, quarry blasts and earthquakes. Here, we explore the potential use of quarry blasts as an active seismic source for subsurface imaging. The goal of our study is to demonstrate the utility of quarry blasts as seismic sources for investigating subsurface structure with a field experiment in Mill Creek, southern Oklahoma. We deployed a 7455-m-long receiver line of 72 receivers (105 m spacing) extending away from a quarry, with a recording time of 28 d. We analyse similarities between blasts, wave types, origin time and excitation location of quarry blasts, which is important information for using such signal as an active source. Given a relative homogeneous geological condition in the study area, we could not observe clear reflected waves. However, the use of P- and S-wave velocities led to the delineation of a major basement damage zone in the study area, which further demonstrates the viability of quarry blasts as a useful seismic source for subsurface geological imaging.

58 GEOSCIENCES↗

The Dark Energy Survey Year 3 high-redshift sample: selection, characterization, and analysis of galaxy clustering

ABSTRACT The fiducial cosmological analyses of imaging surveys like DES typically probe the Universe at redshifts z < 1. We present the selection and characterization of high-redshift galaxy samples using DES Year 3 data, and the analysis of their galaxy clustering measurements. In particular, we use galaxies that are fainter than those used in the previous DES Year 3 analyses and a Bayesian redshift scheme to define three tomographic bins with mean redshifts around z ∼ 0.9, 1.2, and 1.5, which extend the redshift coverage of the fiducial DES Year 3 analysis. These samples contain a total of about 9 million galaxies, and their galaxy density is more than 2 times higher than those in the DES Year 3 fiducial case. We characterize the redshift uncertainties of the samples, including the usage of various spectroscopic and high-quality redshift samples, and we develop a machine-learning method to correct for correlations between galaxy density and survey observing conditions. The analysis of galaxy clustering measurements, with a total signal to noise S/N ∼ 70 after scale cuts, yields robust cosmological constraints on a combination of the fraction of matter in the Universe Ωm and the Hubble parameter h, $\Omega _m h = 0.195^{+0.023}_{-0.018}$, and 2–3 per cent measurements of the amplitude of the galaxy clustering signals, probing galaxy bias and the amplitude of matter fluctuations, bσ8. A companion paper (in preparation) will present the cross-correlations of these high-z samples with cosmic microwave background lensing from Planck and South Pole Telescope, and the cosmological analysis of those measurements in combination with the galaxy clustering presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗