Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Security Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

System-Level Integration of Modular Language Models for Real-Time Risk Assessment in Third-Party Risk Management Systems

Large enterprises typically rely on dedicated teams to govern and implement security measures throughout their supply chains, ensuring compliance with enterprise security procedures. There is a significant reliance on Third-Party Risk Management (TPRM) platforms, which often require complete, highly structured information from potential vendors. The review and compliance assurance processes are time- and labor intensive, often requiring several rounds of review between the supply chain security risk management teams, business users, and potential vendors, leading to delays in the supply chain processing and consumer experience. Significant challenges in the risk management paradigm include handling unstructured data in various formats and providing real-time feedback to users to reduce the required review time. This paper presents a novel solution to these challenges. A modular multi-step system architecture is proposed using advances in language processing, specifically for unstructured responses and provides real-time feedback (i.e., 3 seconds) so that users can improve their responses before the TPSRM team review. This novel system architecture will increase information accuracy and significantly reduce time and labor during the review process.

99 - GENERAL AND MISCELLANEOUS↗

Performance Analysis: Work Control Events Identified January - August 2010

This performance analysis evaluated 24 events that occurred at LLNL from January through August 2010. The analysis identified areas of potential work control process and/or implementation weaknesses and several common underlying causes. Human performance improvement and safety culture factors were part of the causal analysis of each event and were analyzed. The collective significance of all events in 2010, as measured by the occurrence reporting significance category and by the proportion of events that have been reported to the DOE ORPS under the ''management concerns'' reporting criteria, does not appear to have increased in 2010. The frequency of reporting in each of the significance categories has not changed in 2010 compared to the previous four years. There is no change indicating a trend in the significance category and there has been no increase in the proportion of occurrences reported in the higher significance category. Also, the frequency of events, 42 events reported through August 2010, is not greater than in previous years and is below the average of 63 occurrences per year at LLNL since 2006. Over the previous four years, an average of 43% of the LLNL's reported occurrences have been reported as either ''management concerns'' or ''near misses.'' In 2010, 29% of the occurrences have been reported as ''management concerns'' or ''near misses.'' This rate indicates that LLNL is now reporting fewer ''management concern'' and ''near miss'' occurrences compared to the previous four years. From 2008 to the present, LLNL senior management has undertaken a series of initiatives to strengthen the work planning and control system with the primary objective to improve worker safety. In 2008, the LLNL Deputy Director established the Work Control Integrated Project Team to develop the core requirements and graded elements of an institutional work planning and control system. By the end of that year this system was documented and implementation had begun. In 2009, training of the workforce began and as of the time of this report more than 50% of authorized Integration Work Sheets (IWS) use the activity-based planning process. In 2010, LSO independently reviewed the work planning and control process and confirmed to the Laboratory that the Integrated Safety Management (ISM) System was implemented. LLNL conducted a cross-directorate management self-assessment of work planning and control and is developing actions to respond to the issues identified. Ongoing efforts to strengthen the work planning and control process and to improve the quality of LLNL work packages are in progress: completion of remaining actions in response to the 2009 DOE Office of Health, Safety, and Security (HSS) evaluation of LLNL's ISM System; scheduling more than 14 work planning and control self-assessments in FY11; continuing to align subcontractor work control with the Institutional work planning and control system; and continuing to maintain the electronic IWS application. The 24 events included in this analysis were caused by errors in the first four of the five ISMS functions. The most frequent cause was errors in analyzing the hazards (Function 2). The second most frequent cause was errors occurring when defining the work (Function 1), followed by errors during the performance of work (Function 4). Interestingly, very few errors in developing controls (Function 3) resulted in events. This leads one to conclude that if improvements are made to defining the scope of work and analyzing the potential hazards, LLNL may reduce the frequency or severity of events. Analysis of the 24 events resulted in the identification of ten common causes. Some events had multiple causes, resulting in the mention of 39 causes being identified for the 24 events. The most frequent cause was workers, supervisors, or experts believing they understood the work and the hazards but their understanding was incomplete. The second most frequent cause was unclear, incomplete or confusing documents directing the work. Together, these two causes were mentioned 17 times and contributed to 13 of the events. All of the events with the cause of ''workers, supervisors, or experts believing they understood the work and the hazards but their understanding was incomplete'' had this error in the first two ISMS functions: define the work and analyze the hazard. This means that these causes result in the scope of work being ill-defined or the hazard(s) improperly analyzed. Incomplete implementation of these functional steps leads to the hazards not being controlled. The causes are then manifested in events when the work is conducted. The process to operate safely relies on accurately defining the scope of work. This review has identified a number of examples of latent organizational weakness in the execution of work control processes.

99 GENERAL AND MISCELLANEOUS↗

Video performance for high security applications.

The complexity of physical protection systems has increased to address modern threats to national security and emerging commercial technologies. A key element of modern physical protection systems is the data presented to the human operator used for rapid determination of the cause of an alarm, whether false (e.g., caused by an animal, debris, etc.) or real (e.g., a human adversary). Alarm assessment, the human validation of a sensor alarm, primarily relies on imaging technologies and video systems. Developing measures of effectiveness (MOE) that drive the design or evaluation of a video system or technology becomes a challenge, given the subjectivity of the application (e.g., alarm assessment). Sandia National Laboratories has conducted empirical analysis using field test data and mathematical models such as binomial distribution and Johnson target transfer functions to develop MOEs for video system technologies. Depending on the technology, the task of the security operator and the distance to the target, the Probability of Assessment (PAs) can be determined as a function of a variety of conditions or assumptions. PAs used as an MOE allows the systems engineer to conduct trade studies, make informed design decisions, or evaluate new higher-risk technologies. This paper outlines general video system design trade-offs, discusses ways video can be used to increase system performance and lists MOEs for video systems used in subjective applications such as alarm assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

The Federal Radiological Monitoring and Assessment Center (FRMAC) is an operational center, available on request by the Department of Homeland Security (DHS) to respond to nuclear and radiological incidents as described in the National Response Framework (NRF). Under the Federal Interagency Operational Plan for Response and Recovery’s Nuclear/Radiological Annex, the U.S. Department of Energy (DOE) has the responsibility to maintain the operational readiness of the FRMAC during the emergency phase of an event. FRMAC is initially established and managed by the Nuclear Emergency Support Team (NEST) and serves as an interagency operations center with representatives from various federal, state, and local radiological response organizations. The purpose of the FRMAC is to assist state, local, tribal, and territorial governments (SLTT) in their mission to protect the health and well-being of their citizens with: • Verified radiation measurements. • Interpretations of radiation distributions based on Environmental Protection Agency (EPA), Food and Drug Administration (FDA), or local Protective Action Guidelines (PAGs). • Characterization of overall radiological conditions. Once a declaration to respond to a radiological emergency has been made, the National Nuclear Security Administration (NNSA) Headquarters will coordinate the response in consultation with the cognizant NNSA Regional Coordinating Office (RCO). Each of the eight RCOs maintain a 24-hour response capability for radiological emergencies that may occur in states served by its region. When a FRMAC is established, it operates under the parameters of the Incident Command System (ICS), as defined in the National Incident Management Systems (NIMS) construct. The Consequence Management Home Team (CMHT) will be activated immediately during normal business hours (Pacific Time Zone), and within two hours otherwise. The Consequence Management Response Team (CMRT) is prepared for deployment within six hours after activation. Along with the assets, FRMAC provides an operational framework for coordinating of all federal off-site radiological monitoring and assessment activities during a response to a radiological emergency to support the coordinating agency and SLTT governments. Potential radiological emergencies that fall within FRMAC vary widely in terms of the area affected, the nature of the contamination, and the scope of the government’s response. Detonation of a nuclear device, accidental release of radiation from a nuclear power plant, and a terrorist threat are just a few of the many possible scenarios FRMAC must be prepared to address. Through all this, supporting the state, local, and tribal organizations in the protection of the public remains the primary goal of the federal response.

54 ENVIRONMENTAL SCIENCES↗

Plant-specific Model and Data Analysis using Dynamic Security Modeling and Simulation

The requirements for U.S. nuclear power plants to maintain a large on-site physical security force contribute to their high operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability (LWRS) program’s physical security pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. The conservatisms built into current security postures may be analyzed and minimized in order to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within LWRS program’s physical security pathway has successfully developed a dynamic force-on-force modeling framework using various computer simulation tools and integrating them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This document provides an update on the progress in applying a dynamic computational framework that links results from a commercially available force-on-force simulation tool, a commercially available thermal-hydraulic tool, and EMRALD to an operating commercial nuclear power plant. This report is only a summary of the progress and does not contain specific modeling results as those contain sensitive security information. This process of including plant procedures and multiple analysis results is being called Modeling and Analysis for Safety Security using Dynamic EMRALD Framework or MASS-DEF. Previous reports described how a user could integrate their plant-specific force-on-force models with the dynamic simulation tool EMRALD, model operator actions, integrate with probabilistic risk assessment tools, such as CAFTA (Computer Aided Fault Tree Analysis System) or SAPHIRE (Systems Analysis Programs for Hands-on Integrated Reliability Evaluations), and with thermal-hydraulic tools, such as RELAP-5. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report documents the results of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. This report does not contain any plant's sensitive information and/or Safeguards Information. The purpose of this study was to verify that results achieved using generic models are similar to actual plant results and to refine our guidance on the use of the framework. This assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase II Documentation Overview of Corrective Action Unit 98: Frenchman Flat, Nevada Test Site, Nye County, Nevada, Revision 1

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Underground Test Area (UGTA) Subproject to assess and evaluate radiologic groundwater contamination resulting from underground nuclear testing at the NTS. These activities are overseen by the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended March 2010). For Frenchman Flat, the UGTA Subproject addresses media contaminated by the underground nuclear tests, which is limited to geologic formations within the saturated zone or 100 meters (m) or less above the water table. Transport in groundwater is judged to be the primary mechanism of migration for the subsurface contamination away from the Frenchman Flat underground nuclear tests. The intent of the UGTA Subproject is to assess the risk to the public from the groundwater contamination produced as a result of nuclear testing. The primary method used to assess this risk is the development of models of flow and contaminant transport to forecast the extent of potentially contaminated groundwater for the next 1,000 years, establish restrictions to groundwater usage, and implement a monitoring program to verify protectiveness. For the UGTA Subproject, contaminated groundwater is that which exceeds the radiological standards of the Safe Drinking Water Act (CFR, 2009) the State of Nevada’s groundwater quality standard to protect human health and the environment. Contaminant forecasts are expected to be uncertain, and groundwater monitoring will be used in combination with land-use control to build confidence in model results and reduce risk to the public. Modeling forecasts of contaminant transport will provide the basis for negotiating a compliance boundary for the Frenchman Flat Corrective Action Unit (CAU). This compliance boundary represents a regulatory-based distinction between groundwater contaminated or not contaminated by underground testing. Transport modeling simulations are used to compute radionuclide concentrations in time and space within the CAU for the 1,000-year contaminant boundary. These three-dimensional (3-D) concentration simulations are integrated into probabilistic forecasts of the likelihood of groundwater exceeding or remaining below the radiological standards of the Safe Drinking Water Act (CFR, 2009) defined as the contaminant boundary. Contaminant boundaries are not discrete predictions of the location or concentration of contaminants, but instead are spatial representations of the probability of exceeding Safe Drinking Water Act radiological standards. The forecasts provide planning tools to facilitate regulatory decisions designed to protect the health and safety of the public.

54 ENVIRONMENTAL SCIENCES↗

Security Verification Techniques Applied to PatchLink COTS Software

Verification of the security of software artifacts is a challenging task. An integrated approach that combines verification techniques can increase the confidence in the security of software artifacts. Such an approach has been developed by the Jet Propulsion Laboratory (JPL) and the University of California at Davis (UC Davis). Two security verification instruments were developed and then piloted on PatchLink's UNIX Agent, a Commercial-Off-The-Shelf (COTS) software product, to assess the value of the instruments and the approach. The two instruments are the Flexible Modeling Framework (FMF) -- a model-based verification instrument (JPL), and a Property-Based Tester (UC Davis). Security properties were formally specified for the COTS artifact and then verified using these instruments. The results were then reviewed to determine the effectiveness of the approach and the security of the COTS product.

patch↗

High-Octane Mid-Level Ethanol Blend Market Assessment

The United States government has been promoting increased use of biofuels, including ethanol from non-food feedstocks, through policies contained in the Energy Independence and Security Act of 2007. The objective is to enhance energy security, reduce greenhouse gas (GHG) emissions, and provide economic benefits. However, the United States has reached the ethanol blend wall, where more ethanol is produced domestically than can be blended into standard gasoline. Nearly all ethanol is blended at 10 volume percent (vol%) in gasoline. At the same time, the introduction of more stringent standards for fuel economy and GHG tailpipe emissions is driving research to increase the efficiency of spark ignition (SI) engines. Advanced strategies for increasing SI engine efficiency are enabled by higher octane number (more highly knock-resistant) fuels. Ethanol has a research octane number (RON) of 109, compared to typical U.S. regular gasoline at 91-93. Accordingly, high RON ethanol blends containing 20 vol% to 40 vol% ethanol are being extensively studied as fuels that enable design of more efficient engines. These blends are referred to as high-octane fuel (HOF) in this report. HOF could enable dramatic growth in the U.S. ethanol industry, with consequent energy security and GHG emission benefits, while also supporting introduction of more efficient vehicles. HOF could provide the additional ethanol demand necessary for more widespread deployment of cellulosic ethanol. However, the potential of HOF can be realized only if it is adopted by the motor fuel marketplace. This study assesses the feasibility, economics, and logistics of this adoption by the four required participants--drivers, vehicle manufacturers, fuel retailers, and fuel producers. It first assesses the benefits that could motivate these participants to adopt HOF. Then it focuses on the drawbacks and barriers that these participants could face when adopting HOF and proposes strategies--including incentives and policies--to curtail these barriers. These curtailment strategies are grouped into scenarios that are then modeled to investigate their feasibility and explore the dynamics involved in HOF deployment. This report does not advocate for or against incentives or policies, but presents simulations of their effects.

09 BIOMASS FUELS↗

Cyber-Physical System Security of a Power Grid: State-of-the-Art

Here, as part of the smart grid development, more and more technologies are developed and deployed on the power grid to enhance the system reliability. A primary purpose of the smart grid is to significantly increase the capability of computer-based remote control and automation. As a result, the level of connectivity has become much higher, and cyber security also becomes a potential threat to the cyber-physical systems (CPSs). In this paper, a survey of the state-of-the-art is conducted on the cyber security of the power grid concerning issues of: the structure of CPSs in a smart grid; cyber vulnerability assessment; cyber protection systems; and testbeds of a CPS. At Washington State University (WSU), the Smart City Testbed (SCT) has been developed to provide a platform to test, analyze and validate defense mechanisms against potential cyber intrusions. A test case is provided in this paper to demonstrate how a testbed helps the study of cyber security and the anomaly detection system (ADS) for substations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical System Security of Smart Grids

Abstract—This panel presentation will provide perspectives of cyber-physical system security of smart grids. As smart grid technologies are deployed, the interconnected nature of these systems is becoming more prevalent and more complex, and the cyber component of this cyber-physical system is increasing in importance. Studying system behavior in the face of failures (e.g., cyber attacks) allows a characterization of the systems’ response to failure scenarios, loss of communications, and other changes in system environment (such as the need for emergent updates and rapid reconfiguration). The impact of such failures on the availability of the system can be assessed and mitigation strategies considered. Scenarios associated with confidentiality, integrity, and availability are considered. The cyber security implications associated with the American Recovery and Reinvestment Act of 2009 in the United States are discussed.

Dagle, Jeffery E.↗

Assessing and mitigating cybersecurity risks of traffic light systems in smart cities

Intelligent traffic lights are critical cyber‐physical systems that help smart cities to cut road congestion and vehicle emissions. However, they also open a new frontier of cybersecurity. Security researchers have demonstrated ways to compromise the traffic lights to cause potential traffic disruption and public safety degradation. This study aims to raise the public awareness of the cybersecurity issues in traffic light systems. The authors present a bi‐level game‐theoretic framework for assessing cybersecurity risks of traffic light systems, as the first step towards understanding and mitigating the security vulnerabilities. Additionally, they propose a minimax‐regret‐based methodology to guide the deployment of defensive measures in traffic light systems against cyberattacks.

Li, Zhiyi↗

Vadose zone monitoring at the radioactive waste management sites at the Nevada national security site - 15294

Two lysimeter facilities continuously monitor the vadose zone at the radioactive waste disposal sites at the Nevada National Security Site. The time-series data collected at these facilities support the performance assessments of the radioactive waste disposal sites, the closure cover designs, and the long-term monitoring decisions for these sites. The Weighing Lysimeter Facility at the Area 5 Radioactive Waste Management Site (RWMS) consists of a bare-soil weighing lysimeter and a vegetated weighing lysimeter. The upper surfaces of both weighing lysimeters are exposed to precipitation. The Drainage Lysimeter Facility at the Area 3 RWMS includes bare-soil lysimeters that receive precipitation or precipitation supplemented with irrigation equal to double precipitation and vegetated lysimeters that have the same upper boundary conditions as the bare-soil lysimeters. Lysimeter sensors are connected to data-loggers that are accessed remotely for data acquisition. Lysimeter water balance measurements show the arid climate and native vegetation at the NNSS provide a natural sustainable system to effectively prevent transport of contaminants from the RWMSs through the vadose zone to groundwater. Transport by infiltration and percolation of present day precipitation at the RWMSs is prevented. The native desert vegetation is adapted to extract moisture from very dry soils and maintains negative matric potentials at the base of the root zone effectively buffering the deep vadose zone from episodic precipitation events at the surface. The very negative matric potential at the base of the root zone effectively intercepts all infiltration from precipitation and draws moisture upward from the vadose zone below the root zone. This system is sustainable because it does not rely on engineered features and mimics the stable landscapes and no groundwater recharge of the current condition surrounding the RWMSs. The system depends on establishing native vegetation in the covers above the waste cells and a stable climate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification of the accident-related critical digital assets based on probabilistic safety analysis results - 225

Digital I and C systems have been developed and installed in nuclear power plants, and due to installation of the digital I and C systems, cyber security concerns are increasing in nuclear industry. However, there are too many critical digital assets (CDAs) to be inspected in digitalized NPPs. In order to reduce the inefficiency of regulation in nuclear facilities, the critical digital assets that are directly related to an accident are elicited by using the probabilistic safety assessment results. Target initial events are selected, and their heading are analyzed through event tree analysis. Among the headings, the headings that can be proceeded directly to the core damage by the cyber-attack are finally selected as the target of deriving the minimum cut-sets. Based on success criteria of each heading, we analyze the fault trees and derive the minimum set-cuts. In terms of original PSA, the value of probability for the cut-sets is important but the probability is not important in terms of cyber security of NPPs. The important factors is the number of basic events consisting of the minimal cut-sets that is proportional to vulnerability. Finally, the process for identifying accident-related CDAs is suggested based on PSA results. The results of this study are expected to be used to derive the linkage between cyber-attack and accident, and to develop the final core digital asset identification methodology and effective regulatory method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MY EXES and EDM for Automated Remediation Data Quality Assessments - 19053

MY Electronic data exchange and Evaluation System (EXES) is a new web-based technology providing external admin access and full control to the Web-based EXES tool developed by GD for EPA for automated environmental remediation data quality assessments. EXES replaces most manual assessment processes, reducing remediation data review time and costs and ensuring that data are of known and documented quality. This tool is available from EPA to federal agencies and remediation firms and has successfully been used to support over 190 site investigations, 105 Remedial investigations and over 20 compliance monitoring efforts. The new MY EXES functionality has been developed for project managers and decision makers to setup projects, track receipt of environmental remediation monitoring data, assess data quality, and manage data. It is designed to be flexible and configurable to meet any government agency's data review and data management needs. It is accessible 24/7 through a secure portal. MY EXES efficiently evaluates analytical data regardless of the underlying method and data reporting requirements. It is a centralized project and data assessment tool that is scalable, flexible and configurable; improving data quality while reducing cost through the following: - Provides users with the ability to create a project and to specify the analytical methods corresponding to the data that will be submitted for that project. A project can be modified and managed anytime during the project's life cycle. - Allows users to manage a library of analytical methods that can be made available for association to their projects. - Users can specify the automated tests and assessment that needs to be performed on the analytical data deliverables based on specific requirements in the project's Quality Assurance Project Plan (QAPP). - Users specify: - The format of the incoming data deliverables from the laboratory; - The type and level of review services to be performed; - The assessment deliverables to be generated - output spreadsheets and reports; - Project owner sets up system access and permissions for members of the project team. - A faster (600%) and less expensive (85%) process than the traditional data usability/validation. The EXES Data Manager application (EDM) provides a centralized data repository to view and retrieve generated reports, spreadsheets, and other data deliverables as defined by the client, eliminating the need for data transfer between project team members. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Multidimensional Holistic Framework for the Security of Distributed Energy and Control Systems

The digitization of smart grid distributed generation and industrial control systems has prompted utilities to deploy tools with ubiquitous communications that potentially widen the attack surface. The utilities still continue to rely on the traditional cybersecurity technologies, such as firewalls, anti-malware tools, and passwords that do not ensure security across all dimensions of the information assurance model required for a strong cybersecurity business process. This paper proposes a multidimensional holistic framework that addresses this gap through advanced technologies, intelligent algorithms, and continued assessments. To show proof, the layered defense model, a solution dimension of the framework, is integrated into the National Renewable Energy Laboratory's Security and Resilience Testbed to replicate a utility's enterprise and substation networks. The model is used to evaluate the security and resilience of microgrid control systems, and, based on the insights gathered, recommend best practices for utility cybersecurity analysts for a strong business process. Here, with this baseline, the paper conceptually introduces intelligence-driven solutions comprising contextual data analysis and machine learning to respond to advanced persistent threats sponsored by campaign efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensemble-based flood vulnerability assessment for probable maximum flood in a changing environment

The magnitude and frequency of hydro-meteorological extremes are expected to increase in a changing environment in ways that threaten the security of US energy-water assets. These include probable maximum precipitation (PMP) and probable maximum flood (PMF), which are used as hydraulic design standards for highly sensitive infrastructures such as nuclear power plants and main dams. To assess the flood vulnerability due to PMP/PMF, an integrated high-resolution process-based hydro-meteorologic modeling framework was used to develop ensemble-based probabilistic flood maps based on best-available historic observations and future climate projections. A graphics processing unit–accelerated 2-dimensional hydrodynamic model was used to simulate the surface inundation areas corresponding to a total of 120 PMF hydrographs. These ensemble-based PMF maps were compared with flood maps obtained from the conventional deterministic PMP/PMF approach, revealing added information about conditional probability of flooding. Further, a relative sensitivity test was conducted to explore the effects of various factors in the framework, such as meteorological forcings, antecedent hydrologic conditions, reservoir storage, and flood model input resolution and parameters. In conclusion, the proposed framework better illustrates the uncertainties associated with model inputs, parameterization, and hydro-meteorological factors, allowing more informed decision-making for future emergency preparation.

58 GEOSCIENCES↗