Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Comet nucleus sample return mission

A comet nucleus sample return mission in terms of its relevant science objectives, candidate mission concepts, key design/technology requirements, and programmatic issues is discussed. The primary objective was to collect a sample of undisturbed comet material from beneath the surface of an active comet and to preserve its chemical and, if possible, its physical integrity and return it to Earth in a minimally altered state. The secondary objectives are to: (1) characterize the comet to a level consistent with a rendezvous mission; (2) monitor the comet dynamics through perihelion and aphelion with a long lived lander; and (3) determine the subsurface properties of the nucleus in an area local to the sampled core. A set of candidate comets is discussed. The hazards which the spacecraft would encounter in the vicinity of the comet are also discussed. The encounter strategy, the sampling hardware, the thermal control of the pristine comet material during the return to Earth, and the flight performance of various spacecraft systems and the cost estimates of such a mission are presented.

Source record↗

Conic sectors for sampled-data feedback systems

The conic-sector analysis of the closed-loop stability and robustness of a multivariable-analog-system controller based on sampled-data feedback compensation is investigated. Conic sectors and sampled-data feedback systems are defined, and the existence of a conic sector containing a sampled-data operator is established mathematically. An example is presented to prove that the conic sector is computable and gives sufficient conditions of closed-loop stability. A procedure for determining sampled-data-operator gain is also derived.

Thompson, P. M.↗

Optical effects module and passive sample array

The Optical Effects Module (OEM) has the objective to monitor the effects of the deposition and adhesion of both molecular species and particles on optical surfaces in the Shuttle cargo bay environment. The OEM performs inflight measurements of the ultraviolet (253.7 nm) transmittance and diffuse reflectance of five optical samples at regular intervals throughout the orbital mission. Most of the obtained results indicates or implies the absence of a significant accumulation of contamination other than particulates on the samples. The contaminant species (or particulates) adhering to the samples of the Passive Sample Array (PSA) were identified by means of Auger and X-ray energy dispersive analyses. The elements silicon, chlorine, and phosphorus were discovered.

Linton, R. C.↗

Ultrahigh-Vacuum Sample-Transfer System

Ultrahigh-vacuum (UHV) sample-transfer system developed features short-term (less than 30 minutes) transfer of samples from atmospheric pressure into sample manipulator within UHV analysis system without significantly degrading system pressure. New system is austere approach to sample transfer, involving no automation. Total cost of system is factor of 10 less than commercially available instruments.

Outlaw, R.↗

Study of proton and neutron activation of metal samples in low Earth orbit

The analysis of the gamma-ray spectra taken from samples flown in Spacelab 1; the search for and review of neutron and proton activation cross-sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; additional calculations of neutron induced activation for the LDEF samples; the data analysis plan for the LDEF and Spacelab 2 samples; the measurement of relevant cross-sections with activation of samples of V, Co, In, and Ta at the Indiana University Cyclotron Facility; and the preparation of an extended gamma-ray calibration source through the development of a proper technique to accurately deposit equal quantities of radioactive material onto a large number of point on the source are discussed.

Laird, C. E.↗

Mossbauer spectroscopy and X-ray diffraction of samples from the Santa Catharina iron meteorite

Conversion electron Mossbauer spectroscopy (CEMS) of samples from the Santa Catharina iron meteorite shows the presence of the ordered iron-nickel phase with 50% Ni, tetrataenite, and of the paramagnetic iron-nickel phase with 25% Ni. The FeNi phase with 50% Ni amounts to 70% of the iron-nickel alloys. Futhermore, the CEM spectra show the presence of small peaks from one or more spinel compounds. These small peaks are more pronounced when regions near the rim of the samples are analyzed. The X-ray diffraction of different areas of the samples, both optically dark and optically light areas, shows the presence of a diffraction pattern from a single f.c.c. lattice with a lattice parameter of a=3.58A This means that the two different Fe-Ni phases seen in the CEMS analysis occupy the same lattice. The X-ray photographs also show the presence of super-structure reflections from the ordered FeNi phase, and that the orientation of the f.c.c. lattice is the same within the whole sample.

Roy-Poulsen, H.↗

Sample return from a comet flyby

Sample collection and return to the Earth from a fast fly through of a cometary coma is the simplest sample return mission possible from any extraterrestrial body. The mission can provide valuable laboratory samples from a known cometary body and it can do it at low cost, within our lifetimes. The method and the merits of the sample collection process from a comet flyby are discussed.

Brownlee, D. E.↗

Moisture content and gas sampling device

An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.

Krieg, H. C., Jr.↗

A medium-bright quasar sample - New quasar surface densities in the magnitude range from 16.4 to 17.65 for B

A new medium-bright quasar sample (MBQS) is constructed from spectroscopic observations of 140 bright objects selected for varying degrees of blue and ultraviolet excess (B-UVX) in five Palomar 1.2 m Schmidt fields. The MBQS contains 32 quasars with B less than 17.65 mag. The new integral surface densities in the B range from 16.45 to 17.65 mag are approximately 40 percent (or more) higher than expected. The MBQS and its redshift distribution increase the area of the Hubble diagram covered by complete samples of quasars. The general spectroscopic results indicate that the three-color classification process used to catalog the spectroscopic candidates (1) has efficiently separated the intrinsically B-UVX stellar objects from the Population II subdwarfs and (2) has produced samples of B-UVX objects which are more complete than samples selected by (U - B) color alone.

Mitchell, K. J.↗

Acoustic Translation of an Acoustically Levitated Sample

Acoustic-levitation apparatus uses only one acoustic mode to move sample from one region of chamber to another. Sample heated and cooled quickly by translation between hot and cold regions of levitation chamber. Levitated sample is raised into furnace region by raising plunger. Frequency of sound produced by transducers adjusted by feedback system to maintain (102) resonant mode, which levitates sample midway between transducers and plunger regardless of plunger position.

Barmatz, M. B.↗

Planetary sample rapid recovery and handling

Methods for recovering and cost effectively handling planetary samples following return to the vicinity of Earth were designed for planetary mission planners. Three topics are addressed: (1) a rough cost estimate was produced for each of a series of options for the handling of planetary samples following their return to the vicinity of Earth; (2) the difficulty of quickly retrieving planetary samples from low circular and high elliptical Earth orbit is assessed; and (3) a conceptual design for a biological isolation and thermal control system for the returned sample and spacecraft is developed.

Source record↗

Samples at the Apollo 15 landing site: Types and distribution

Samples, consisting of more than 350 individually numbered samples of rock and regolith, were collected during the three EVAs on the Apollo 15 mission. Samples consisted of rock specimens, and scooped, trenched, and cored regolith samples. Petrographic and chemical analysis are discussed.

Ryder, G.↗

The stability of a sample in a diamond anvil cell

A theoretical analysis of the stability of a gasketed sample in a diamond anvil cell is reported, demonstrating that the stability of the sample depends principally on the yield strength and the thickness of the gasket, the bulk modulus and the radius of the sample, and the geometry of the culet. The results yield a simple methodology that can be used to obtain stable samples in a diamond anvil cell.

Moss, William C.↗

Shock effects and argon loss in samples of the Leedey L6 chondrite experimentally shocked to 29-70 GPa pressures

The recovery of polished 600-micron-thick 7-mm-diameter disk samples and powder samples of the Leedey L6 chondrite from 29-70-GPa experimental shocks is investigated experimentally under vacuum conditions, with a focus on the possible direct shock loss of radiogenic Ar. The results of petrographic examination of the shocked samples and Ar isotope measurements are presented in tables, graphs, and micrographs and characterized in detail. The principal damage mechanisms are identified as mechanical disaggregation and increasing cataclasis, with little melting. The degassing of radiogenic Ar is found to be relatively modest and to increase with shock pressure and sample porosity; it is attributed to a combination of mechanical grain disruption and feldspar melting. It is inferred that Ar loss in naturally shocked materials (especially those showing few signs of melting) probably occurs during extended exposure to high temperatures during impact formation.

Bogard, Donald↗

Mineralogical studies of sulfide samples and volatile concentrations of basalt glasses from the southern Juan de Fuca Ridge

Sulfide samples obtained from Alvin dives on the southern Juan de Fuca Ridge were examined, showing the presence of two previously undiscovered minerals, both formed at low temperatures. The first detection of lizardite, starkeyite, and anatase in such an environment is also reported. Sulfide geothermometry involving the Cu-Fe-S system shows a vent temperature of less than 328 C for one sample. Ice-melting temperatures on inclusions from this sample are about -2.8 C, and fluid inclusion studies on crystals near this sample show pressure-corrected homogenization temperatures of 268 and 285 C. Volatile concentrations from vesicle-free basalt glass from the vent field are found to be about 0.0013 wt pct CO2 and 0.16 wt pct H2O.

Brett, Robin↗

A model study of potential sampling errors due to data scatter around expendable bathythermograph transects in the tropical Pacific

A linear multiple vertical-mode model described by McPhaden et al. (1988) is used to examine potential errors due to data scatter around expendable bathythermograph (XBT) transects in the tropical Pacific. Two methods of sampling are compared. In the first, the model was sampled along approximately straight lines of grid points corresponding to the mean positions of XBT tracks in the eastern, central, and western Pacific; in the second, the model was sampled again at the dates and locations of actual XTB casts for 1979-1983. The model indicates that the data scattered zonally around XBT transects in general can lead to about 2 dyn cm error in dynamic height in composite sections of XBT data. Errors larger than 2 dyn cm occurred in regions where XBT sample spacing in the zonal direction was insufficient to resolve Rossby wave variations in the model.

Mcphaden, Michael J.↗

Fluid inclusions in Martian samples: Clues to early crustal development and the hydrosphere

Major questions about Mars that could be illuminated by examining fluid inclusions in Martian samples include: (1) the nature, extent and timing of development (and decline) of the hydrosphere that existed on the planet; and (2) the evolution of the crust. Fluid inclusion analyses of appropriate samples could provide critical data to use in comparison with data derived from analogous terrestrial studies. For this study, sample handling and return restrictions are unlikely to be as restrictive as the needs of other investigators. The main constraint is that the samples not be subjected to excessively high temperatures. An aqueous fluid inclusion trapped at elevated pressure and temperature will commonly consist of liquid water and water vapor at room temperature. Heating (such as is done in the laboratory to fix P-V-T data for the inclusion) results in moderate pressure increases up to the liquid-vapor homogenization temperature followed by a sharp increase in pressure with continued heating because the inclusion is effectively a fixed volume system. This increased pressure can rupture the inclusion; precise limits are dependent on size, shape, and composition as well as the host material.

Brown, Philip E.↗

Mars sampling strategy and aeolian processes

It is critical that the geological context of planetary samples (both in situ analyses and return samples) be well known and documented. Apollo experience showed that this goal is often difficult to achieve even for a planet on which surficial processes are relatively restricted. On Mars, the variety of present and past surface processes is much greater than on the Moon and establishing the geological context of samples will be much more difficult. In addition to impact hardening, Mars has been modified by running water, periglacial activity, wind, and other processes, all of which have the potential for profoundly affecting the geological integrity of potential samples. Aeolian, or wind, processes are ubiquitous on Mars. In the absence of liquid water on the surface, aeolian activity dominates the present surface as documented by frequent dust storms (both local and global), landforms such as dunes, and variable features, i.e., albedo patterns which change their size, shape, and position with time in response to the wind.

Greeley, Ronald↗