Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Sources, frequency, and chemical nature of dust events impacting the United States East Coast

This study examines 14 years (2004–2017) of surface aerosol composition data from the EPA IMPROVE network with a focus on the monthly profile, sources, and chemical nature of extreme dust events (>92nd percentile of fine soil concentration each month) impacting ten sites along the United States East Coast ranging in latitude from Florida to Maine. Based on trajectory, remote sensing, and reanalysis data, dust events were categorized into four source categories: African, Asian, Mix (African + Asian), and Other (anything other than African and Asian). The results reveal that extreme dust events account for between 3.3% and 4.6% of total available days depending on the site. March-April-May (MAM) had the most (174) dust events, followed by June-July-August (JJA) with 172, and then by September-October-November (SON) with 160 and December-January-February (DFJ) with 150. There is a variability in the predominant dust sources based on latitude, with African and Other sources more influential from North Carolina to the south, while Asian and Other were most important from New Jersey to the north. The Mix category is consistently the least frequent dust category at all sites. The African dust category was linked to the highest fine soil levels across the entire East Coast relative to other sources regardless of location. JJA is mostly impacted by African dust for sites ranging from Florida to New Jersey, while MAM is dominated by Asian dust for all sites. Mix events occurred mostly between April and October and Other events were most common outside of MAM and JJA seasons. Seven out of ten sites had Other as the most dominant source. Aerosol constituents organic carbon (OC) and elemental carbon (EC) had higher average concentrations in Other events (2.39 ± 0.78 μg m -3 and 0.79 ± 0.81 μg m -3 , respectively) as compared to the other three source categories, suggestive of regional anthropogenic emissions. Moreover, the ratios of elements (Si:Al, K:Fe, Fe:Ca, Al:Ca) contributing to fine soil and PM 2.5 :PM 10 exhibited distinct values depending on the dust source category and the site. This study builds on the growing evidence of the importance of long-range transport of dust in impacting distant regions and how a variety of sources can impact the U.S. East Coast at all times of the year.

Abdulmonam M. Aldhaif↗

Sensitivity studies of nighttime top-of-atmosphere radiances from artificial light sources using a 3-D radiative transfer model for nighttime aerosol retrievals

By accounting for surface-based light source emissions and top-of-atmosphere (TOA) downward lunar fluxes, we adapted the spherical harmonics discrete ordinate method (SHDOM) 3-dimensional (3-D) radiative transfer model (RTM) to simulate nighttime 3-D TOA radiances as observed from the Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) on board the Suomi-NPP satellite platform. Used previously for daytime 3-D applications, these new SHDOM enhancements allow for the study of the impacts of various observing conditions and aerosol properties on simulated VIIRS-DNB TOA radiances. Observations over Dakar, Senegal, selected for its bright city lights and a large range of aerosol optical depth (AOD), were investigated for potential applications and opportunities for using observed radiances containing VIIRS-DNB “bright pixels” from artificial light sources to conduct aerosol retrievals. We found that using the standard deviation (SD) of such bright pixels provided a more stable quantity for nighttime AOD retrievals than direct retrievals from TOA radiances. Further, both the mean TOA radiance and SD of TOA radiances over artificial sources are significantly impacted by satellite viewing angles. Light domes, the enhanced radiances adjacent to artificial light sources, are strong functions of aerosol properties and especially aerosol vertical distribution, which may be further utilized for retrieving aerosol layer height in future studies. Through inter-comparison with both day- and nighttime Aerosol Robotic Network (AERONET) data, the feasibility of retrieving nighttime AODs using 3-D RTM SHDOM over artificial light sources was demonstrated. Our study shows strong potential for using artificial light sources for nighttime AOD retrievals, while also highlighting larger uncertainties in quantifying surface light source emissions. This study underscores the need for surface light emission source characterizations as a key boundary condition, which is a complex task that requires enhanced input data and further research. We demonstrate how quality-controlled nighttime light data from NASA’s Black Marble product suite could serve as a primary input into estimations of surface light source emissions for nighttime aerosol retrievals.

Jianglong Zhang↗

Acceleration of Monte Carlo Criticality Calculations Using Deterministic-Based Starting Sources

A new automatic approach that uses approximate deterministic solutions for providing the starting fission source for Monte Carlo eigenvalue calculations was evaluated in this analysis. By accelerating the Monte Carlo source convergence and decreasing the number of cycles that has to be skipped before the tally's estimation, this approach was found to increase the efficiency of the overall simulation, even with the inclusion of the extra computational time required by the deterministic calculation. This approach was also found to increase the reliability of the Monte Carlo criticality calculations of loosely coupled systems because the use of the better starting source reduces the likelihood of producing an undersampled k eff due to the inadequate source convergence. The efficiency improvement was demonstrated using two of the standard test problems devised by the OECD/NEA Expert Group on Source Convergence in Criticality-Safety Analysis to measure the source convergence in Monte Carlo criticality calculations. For a fixed uncertainty objective, this approach increased the efficiency of the overall simulation by factors between 1.2 and 3 depending on the difficulty of the source convergence in these problems. The reliability improvement was demonstrated in a modified version of the 'k eff of the world' problem that was specifically designed to demonstrate the limitations of the current Monte Carlo power iteration techniques. For this problem, the probability of obtaining a clearly undersampled k eff decreased from 5% with a uniform starting source to zero with a deterministic starting source when batch sizes with more than 15,000 neutron/cycle were used.

42 ENGINEERING↗

Detecting fission from special nuclear material sources

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a graphing component that displays the plot of the neutron distribution from the unknown source over a Poisson distribution and a plot of neutrons due to background or environmental sources. The system further includes a known neutron source placed in proximity to the unknown source to actively interrogate the unknown source in order to accentuate differences in neutron emission from the unknown source from Poisson distributions and/or environmental sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems [Abstract]

The equivalent fundamental-mode source refers to a “source” which is identically distributed in space, energy, and angle as that of a fundamental-mode fission source distribution. It has previously been shown that the system fixed source multiplication ($M_{fs}$) relates to the effective multiplication factor ($\kappa_{eff}$) as $M_{fs} = \frac{g^*}{1-k_{eff}}$ The term $\mathcal{g}$* therefore relates the system source distribution to the system equivalent fundamental-mode source. As previously shown, the $\mathcal{g}$* term is approximately 1 for deeply subcritical systems and then diverges as the system multiplication increases. For a system with a point source located in the center of an assembly (such a sphere), $\mathcal{g}$* will be greater than 1; this happens because there is a higher probability of induced fission when all of the starter neutrons originate from the center of the sphere. For a uniform source, $\mathcal{g}$* is less than 1, but does not diverge from 1 as dramatically as seen by a point source. One reason that $\mathcal{g}$* is an important parameter is that it is used in measurement methods to infer reactor kinetics parameters ($β_{eff}$ being one example). This work will discuss multiple ways to simulate $\mathcal{g}$* using MCNP®6.2, which include use of traditional methods versus a single input file method that was recently published. A discussion related to methods to simulate $M_{fs}$ will be presented. Spherical systems of Highly Enriched Uranium (HEU) will be compared with previous works. In addition, results of plutonium including multiple reflector materials will be investigated. Simulated systems will include both parametric studies as well as configurations used in recent experiments performed at the National Criticality Experiments Research Center (NCERC). These studies will include subtleties associated with system geometry that have not been previously shown. Last, this work will investigate the relationship between $\mathcal{g}$* and reactor kinetics parameters (such as $β_{eff}$).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Classification Analytics of Pu-239 and U-235 Source Signatures Using Gamma Spectral Regions

Machine learning detection methods using gamma signatures from spectral measurements of low-intensity Pu-239 and U-235 sources are studied. NaI detectors located at different distances fromthe source have been used to collect the training and independent testing data sets. The source is introduced via a shielded conduit into the facility where it is surrounded by 21 NaI detectors deployed over 6 x 6 meters area in the formation of two concentric circles and a spiral. The counts in gamma spectral regions associated with these two sources are estimated at 1 second intervals for each NaI detector, and are used as classifier features for detecting the source presence. Eight different classifiers with five basic properties — namely, smooth, non-smooth, statistical, structural, and hyper-parameter tuning — are trained and tested using the background and source measurements collected over multiple experimental runs. While the overall classifier performance improved as detectors closer to the source are used, some identically produced detectors under-performed but differently between two sources. Some classifiers achieved lower training error but their testing error based on independent measurements is higher for both sources. Overall, these results indicate significant over-fitting by these methods, and illustrate the complexity of training and selecting the machine learning methods to solve these detection problems.

Rao, Nageswara↗

Extreme high vacuum for polarized electron sources

Nuclear physics experiments often require highly polarized electron beams to do precise measurements of the structure and size of nucleons and the nucleus, as well as for searches for physics beyond the standard model. Jefferson Lab?s electron source, with polarization near 90%, has been providing polarized electron beams for CEBAF for over two decades. Development is underway for polarized electron sources at MESA at Mainz and the Electron Ion Collider at Brookhaven National Lab, and there is potential for polarized electron beam in the future at facilities including the International Linear Collider, an electron upgrade at CERN, and the SuperKEKB collider in Japan. At Jefferson Lab there are even plans to make use of polarized electrons to make a polarized positron source for experimental nuclear physics. High polarization electron beams are generated using photoemission from strained superlattice GaAs based photocathodes, and photocathode lifetime is limited by the ionization of residual gas in the system, which is then accelerated into the photocathode. Extreme high vacuum (near 1x10-10 Pa) is required to operate the Jefferson Lab polarized electron source with an acceptable lifetime, and the upcoming projects will need various combinations of higher current, higher bunch charge and longer photocathode lifetimes. To meet the vacuum requirements for polarized electron sources, every component for a polarized electron source must be optimized, including chamber materials, pumps, bakeout procedure and the high voltage electrode geometry and processing. Each change in these components must be evaluated offline before being used in the accelerator, and effects on pressure are difficult to evaluate even using XHV-optimized hot filament ionization gauges. In fact, we do not get a final evaluation of system modifications until an electron source is built, installed and lifetime measurements are made over the course of months or years of operation. I will be discussing the evolution of vacuum in the Jefferson Lab polarized source system toward XHV pressures and discuss the characterization and limitations measured for commercially available XHV vacuum gauges. Finally, I?ll present the effect of system pressure on photocathode lifetime and highlight how XHV pressure standards can benefit the ongoing efforts to improve vacuum for the next generation of polarized electron sources.

Stutzman, Marcy↗

A Grid Intensity Map-Based Source Model for Monte Carlo Modeling of IMRT Field Irradiation - Paper 5

An accurate source model is important for TPS (Treatment Planning System) dose calculation and verification, especially for IMRT (Intensity Modulated Radiotherapy) irregular and inhomogeneous fields. Monte Carlo simulation is the most accurate way to calculate dose distributions in the heterogeneous media like human bodies. A full radiotherapy modeling generally includes Linac modeling and phantom dose calculation. Full Linac modeling is very time-consuming and requires highly detailed knowledge of the accelerator composition and structure, however, which is very difficult to obtain for commercial interests. Often all relevant parameters are not known with sufficient accuracy, and thus a time-consuming tuning of e.g. the electron beam spot size and energy must be performed. A multiple source model (MSM) regards particles coming from different parts of an accelerator as if they are coming from different virtual sources. MSM uses a set of virtual sources representing the treatment beam (e.g. primary photons, head scatter, electron contamination) by a set of analytic functions or histograms with parameters derived from dosimetric measurements or a full MC simulation. Tillikainen et al built a three sub-source model by matching with measurement data using an automatic process to optimize the free model parameters for a Varian 2100 C/D accelerator. Lin et al have built a convenient five-photon-sub-source model for Varian 2300C 6 MV-X beam based on Monte Carlo simulated Linac for ARTS (Accurate Radiotherapy System). The particle generation of MSM is very fast compared to full Linac simulation, and its sampling efficiency is not limited by the size of the phase space file (PSF). However, generally MSM is generated based on regular field PSF and needs an irregular component to form the beam shape meanwhile apt to bringing error Linac modeling and MSM producing from PSF analysis actually both are multi-freedom optimization process by adjusting several parameters (e.g. electron energy and angular divergence). Linac modeling adjusts its parameters from the beginning of electron hitting target through all components to fit the simulation to the measurement. MSM tunes its PSF-derived parameters by optimizing to minimize the deviations between the simulation and the measurement. Since the full Linac modeling and the MSM model both need to fine tune their parameters to match the simulation to the measurement, and sometimes maybe offsets the real accelerator for its multi-parameter optimization process. So, why not fine tune directly all source model parameters just behind all Linac components to fit the simulation to the measurement? A grid intensity-based surface source model was suggested here, which assumed the particle emitting from the bottom surface of Linac last beam trimmer MLC (Multi Leaf Collimator). The particle emitting position is sampled on the grid intensity map optimized by TPS, and the particle weight is adjusted by its original grid intensity. This source model not only takes advantage of the Monte Carlo method in the heterogeneous media, but also avoids effectively the transportation speed shortcoming of Monte Carlo simulation through Linac components. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. The {approx}1 ms-long, 60 Hz, {approx}50 mA H{sup -} beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of {approx}99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

07 ISOTOPE AND RADIATION SOURCES↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid model of the sheath in front of a floating electrode immersed in a magnetized plasma with oblique magnetic field: Some comments on ion source terms and ion temperature effects

A one-dimensional fluid model of the magnetized plasma-wall transition region in front of a floating electrode immersed in a magnetized plasma with oblique magnetic field is presented. The Boltzmann relation is assumed for the electrons, while the positive ions obey the ion continuity and momentum exchange equation. The ions are assumed to be isothermal. By comparison with a two-fluid model, it is shown that assuming the Boltzmann relation for the electrons implies that there is no creation or annihilation of the electrons. Consequently, there should not be any creation and annihilation of the positive ions either. The models that assume the Boltzmann relation for the electrons and a non-zero ion source term at the same time are therefore inconsistent, but such models have nevertheless been used extensively by many authors. So, in this work, an extensive comparison of the results obtained using the zero source term on one hand and three different non-zero source terms on the other hand is made. Four different ion source terms are considered in total: the zero source term and three different non-zero ion source terms. When the zero source term is used, the model becomes very sensitive to the boundary conditions, and in some cases, the solutions exhibit large amplitude oscillations. If any of the three non-zero ion source terms is used, those problems are eliminated, but also the consistency of the model is broken. The model equations are solved numerically in the entire magnetized plasma-wall transition region. For zero ion temperature, the model can be solved even if a very small ion velocity is selected as a boundary condition. For finite ion temperature, the system of equations becomes stiff, unless the ion velocity at the boundary is increased slightly above the ion thermal velocity. A simple method how to find a solution with a very small ion velocity at the boundary also for finite ion temperature in the entire magnetized plasma-wall transition region is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment on security system of radioactive sources used in hospitals of Thailand

Unsecured radioactive sources have caused deaths and serious injuries in many parts of the world. In Thailand, there are 17 hospitals that use teletherapy with cobalt-60 radioactive sources. They need to be secured in order to prevent unauthorized removal, sabotage and terrorists from using such materials in a radiological weapon. The security system of radioactive sources in Thailand is regulated by the Office of Atoms for Peace in compliance with Global Threat Reduction Initiative (GTRI), U.S. DOE, which has started to be implemented since 2010. This study aims to perform an assessment on the security system of radioactive sources used in hospitals in Thailand and the results can be used as a recommended baseline data for development or improvement of hospitals on the security system of a radioactive source at a national regulatory level and policy level. Results from questionnaires reveal that in 11 out of 17 hospitals (64.70%), there were a few differences in conditions of hospitals using radioactive sources with installation of the security system and those without installation of the security system. Also, personals working with radioactive sources did not clearly understand the nuclear security law. Thus, government organizations should be encouraged to arrange trainings on nuclear security to increase the level of understanding. In the future, it is recommended that the responsible government organization issues a minimum requirement of nuclear security for every medical facility using radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

CHANDRA AND HST STUDIES OF THE X-RAY SOURCES IN GALACTIC GLOBULAR CLUSTER M92

We present the analysis of two observations of M92 taken with the Chandra X-Ray Observatory. We combined the two data sets with a total exposure of {approx}52 ks. With the combined observation, we detected 10 X-ray sources inside the half-mass radius (1.'02), five of which are inside the core radius (0.'26) of M92. The luminosities of the 10 sources are roughly within the range of 10{sup 30}-10{sup 32} erg s{sup -1} assuming cluster memberships. The background estimation suggests 7-8 cluster members and 2-3 background galaxies in M92. We identified the 10 sources by using Hubble Space Telescope Advanced Camera for Surveys observations of M92. Based on the X-ray and optical characteristics, we classified 4-5 possible candidates for cataclysmic variables within the half-mass radius. We discussed the possible formation mechanisms of the X-ray sources in M92 by comparing the predicted X-ray source number and observational results. Under the assumption that the number of X-ray sources scales with the encounter rate and the mass of the globular cluster, we expected eight X-ray sources formed from dynamical interactions and four from primordial binaries inside M92, which is consistent with the background estimation and comparable with the observational results. We therefore suggest that the X-ray sources in M92 may be contributed from both dynamical origin and primordial binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-NEWTON OBSERVATIONS OF THE TeV {gamma}-RAY SOURCE HESS J1804-216

We have analyzed three XMM-Newton observations of the central part of the unidentified TeV {gamma}-ray source HESS J1804-216. We focus on two X-ray sources, 2XMMi J180442.0-214221 (Src 1) and 2XMMi J180432.5-214009 (Src 2), which were suggested to be the possible X-ray counterparts to the TeV source. We discover a 2.93 hr X-ray periodicity from Src 1, with the pulse profile explained with a self-eclipsing pole in an eclipsing polar. Src 2 exhibits a strong Fe emission line (FWHM {approx} 0.3 keV and equivalent width {approx}0.8 keV) and large X-ray variability on timescales of hours and is probably an intermediate polar. Thus Src 1 and Src 2 are probably two field sources not responsible for the TeV emission. The observations were contaminated by strong stray light from a nearby bright source, and we see no clear extended X-ray emission that can be attributed to the supernova remnant G8.7-0.1, a popular possible association with the TeV source. The other possible association, the pulsar wind nebula candidate PSR J1803-2137, shows little long-term variability compared with a previous Chandra observation. Many point sources were serendipitously detected, but most of them are probably normal stars. Three new candidate compact object systems (other than Src 1, Src 2, and PSR J1803-2137) are also found. They are far away from the TeV source and are probably also magnetic cataclysmic variables, thus unlikely to be responsible for the TeV emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of a highly variable dipping ultraluminous X-ray source in M94

We report the discovery of a new ultraluminous X-ray source (ULX) 2XMM J125048.6+410743 within the spiral galaxy M94. The source has been observed by ROSAT, Chandra, and XMM-Newton on several occasions, exhibiting as a highly variable persistent source or a recurrent transient with a flux variation factor of ≳100, a high duty cycle (at least ∼70%), and a peak luminosity of L {sub X} ∼ 2 × 10{sup 39} erg s{sup –1} (0.2-10 keV, absorbed). In the brightest observation, the source is similar to typical low-luminosity ULXs, with the spectrum showing a high-energy cutoff but harder than that from a standard accretion disk. There are also sporadical short dips, accompanied by spectral softening. In a fainter observation with L {sub X} ∼ 3.6 × 10{sup 38} erg s{sup –1}, the source appears softer and is probably in the thermal state seen in Galactic black hole X-ray binaries (BHBs). In an even fainter observation (L {sub X} ∼ 9 × 10{sup 37} erg s{sup –1}), the spectrum is harder again, and the source might be in the steep-power-law state or the hard state of BHBs. In this observation, the light curve might exhibit ∼7 hr (quasi-)periodic large modulations over two cycles. The source also has a possible point-like optical counterpart from Hubble Space Telescope images. In terms of the colors and the luminosity, the counterpart is probably a G8 supergiant or a compact red globular cluster containing ∼2 × 10{sup 5} K dwarfs, with some possible weak UV excess that might be ascribed to accretion activity. Thus, our source is a candidate stellar-mass BHB with a supergiant companion or with a dwarf companion residing in a globular cluster. Our study supports that some low-luminosity ULXs are supercritically accreting stellar-mass BHBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental validation of a kilovoltage x-ray source model for computing imaging dose

Purpose: To introduce and validate a kilovoltage (kV) x-ray source model and characterization method to compute absorbed dose accrued from kV x-rays. Methods: The authors propose a simplified virtual point source model and characterization method for a kV x-ray source. The source is modeled by: (1) characterizing the spatial spectral and fluence distributions of the photons at a plane at the isocenter, and (2) creating a virtual point source from which photons are generated to yield the derived spatial spectral and fluence distribution at isocenter of an imaging system. The spatial photon distribution is determined by in-air relative dose measurements along the transverse (x) and radial (y) directions. The spectrum is characterized using transverse axis half-value layer measurements and the nominal peak potential (kVp). This source modeling approach is used to characterize a Varian{sup ®} on-board-imager (OBI{sup ®}) for four default cone-beam CT beam qualities: beams using a half bowtie filter (HBT) with 110 and 125 kVp, and a full bowtie filter (FBT) with 100 and 125 kVp. The source model and characterization method was validated by comparing dose computed by the authors’ inhouse software (kVDoseCalc) to relative dose measurements in a homogeneous and a heterogeneous block phantom comprised of tissue, bone, and lung-equivalent materials. Results: The characterized beam qualities and spatial photon distributions are comparable to reported values in the literature. Agreement between computed and measured percent depth-dose curves is ⩽2% in the homogeneous block phantom and ⩽2.5% in the heterogeneous block phantom. Transverse axis profiles taken at depths of 2 and 6 cm in the homogeneous block phantom show an agreement within 4%. All transverse axis dose profiles in water, in bone, and lung-equivalent materials for beams using a HBT, have an agreement within 5%. Measured profiles of FBT beams in bone and lung-equivalent materials were higher than their computed counterparts resulting in an agreement within 2.5%, 5%, and 8% within solid water, bone, and lung, respectively. Conclusions: The proposed virtual point source model and characterization method can be used to compute absorbed dose in both the homogeneous and heterogeneous block phantoms within of 2%–8% of measured values, depending on the phantom and the beam quality. The authors’ results also provide experimental validation for their kV dose computation software, kVDoseCalc.

61 RADIATION PROTECTION AND DOSIMETRY↗