Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Modulation by orexin A of spontaneous excitatory and inhibitory transmission in adult rat spinal substantia gelatinosa neurons

Highlights: • Orexin A produced membrane depolarization in substantia gelatinosa neurons. • Orexin A increased spontaneous l-glutamate release in substantia gelatinosa neurons. • Orexin A facilitated GABAergic transmission in substantia gelatinosa neurons. • Orexin A facilitated glycinergic transmission in substantia gelatinosa neurons. • All of orexin A activities were due to orexin-1 but not orexin-2 receptor activation. Hypothalamic neuropeptides, orexins A and B, differently inhibit nociceptive behavior. This difference is possibly due to a distinction between orexins A and B in modulating synaptic transmission in spinal substantia gelatinosa (SG) neurons that play a pivotal role in regulating nociceptive transmission. Although we previously reported a modulatory action of orexin B on synaptic transmission in adult rat SG neurons, it has not been fully examined how the transmission is affected by orexin A. The present study examined the effects of orexin A on spontaneous excitatory and inhibitory transmission in SG neurons of adult rat spinal cord slices by using the whole-cell patch-clamp technique. Like orexin B, orexin A produced an inward current at −70 mV and/or increased the frequency of spontaneous excitatory postsynaptic current without changing its amplitude. Half-maximal effective concentration values for their effects were 0.0045 and 0.030 μM, respectively; the former value was four-fold smaller than that of orexin B while the latter value was comparable to that of orexin B. Orexin A enhanced not only glycinergic but also GABAergic transmission, although only glycinergic transmission was facilitated by orexin B in the majority of neurons tested. Orexin A activities were inhibited by an orexin-1 receptor antagonist (SB334867) but not an orexin-2 receptor antagonist (JNJ10397049), as different from orexin B whose activation was depressed by JNJ10397049 but not SB334867. These results indicate that orexin A has a different action from orexin B in SG neurons in efficacy for inward current production and in GABAergic transmission enhancement, possibly owing to orexin-1 but not orexin-2 receptor activation. This difference could contribute to at least a part of the distinction between orexins A and B in antinociceptive effects.

60 APPLIED LIFE SCIENCES↗

Activation of galanin receptor 1 inhibits locus coeruleus neurons via GIRK channels

The noradrenergic neurons of the locus coeruleus (LC) are associated with various brain functions and psychiatric disorders, such as addiction and depression. It has been shown that neuropeptide galanin (GAL) inhibits neuronal excitability in LC, but the mechanisms remain unclear. In the present study, we investigated the ionic and signal transduction mechanisms underlying inhibitory effect of GAL on LC neurons using whole-cell patch clamp recording in rat brain slices. Bath application of GAL decreased the spontaneous firings and induced a dose-dependent hyperpolarization of LC neurons and this effect was attenuated by knockdown of Galr1, but not Galr2, confirming that mainly GALR1 mediates the inhibition effect of GAL. The inhibitory effect of GAL was also blocked by treatments of pertussis toxin (PTX), GTP-γ-s or GDP-β-s, respectively, indicating that the functions of PTX sensitive G{sub i/o} protein are required for GAL-induced hyperpolarization. Moreover, the blockers of GIRK (tertiapin-Q or SCH2 3390 hydrochloride) attenuated the GAL response while blocker of BK/SK/K{sub ATP} channels or TASK-1/3 channels did not affect it significantly, suggesting that GIRK channels play an important role in GAL-induced hyperpolarization in LC neurons. Taken together, the inhibitory effect of GAL on LC neurons is mediated by GALR1 via PTX-sensitive G{sub i/o} proteins, which activate GIRK channels.

60 APPLIED LIFE SCIENCES↗

Point containment algorithms for constructive solid geometry with unbounded primitives

Here, we present several algorithms for evaluating point containment in constructive solid geometry (CSG) trees with unbounded primitives. Three algorithms are presented based on postfix, prefix, and infix notations of the CSG binary expression tree. We show that prefix and infix notations enable short-circuiting logic, which reduces the number of primitives that must be checked during point containment. To evaluate the performance of the algorithms, each algorithm was implemented in the OpenMC Monte Carlo particle transport code, which relies on CSG to represent solid bodies through which subatomic particles travel. Two sets of tests were carried out. First, the execution time to generate a rasterized image of a 2D slice of three CSG models of varying complexity was measured. Use of both prefix and infix notations offered significant speedup over the postfix notation that has traditionally been used in particle transport codes, with infix resulting in a 6 x reduction in execution time relative to postfix for a model of a tokamak fusion device. We then measured the execution time of neutron transport simulations of the same three models using each of the algorithms. The results and performance improvements reveal the same trends as for the rasterization test, with a 5.52 x overall speedup using the infix notation relative to the original postfix notation in OpenMC for the tokamak model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of early hydration temperature on hydration product and strength development of magnesium phosphate cement (MPC)

This paper investigates the effect of early hydration temperatures on hydration products and strength development of magnesium phosphate cement (MPC). MPC paste specimens with borate contents of 3%, 6%, 9% and 12% are prepared and cured in different air temperatures and in the adiabatic condition. The internal hydration temperatures are measured by pre-embedded temperature probes. MPC samples with different hydration temperatures are also obtained by using thin slice samples. The hydration products in MPC samples with different hydration temperatures are analyzed by X-ray diffractometer (XRD) and scanning electron microscope (SEM) and the strength development is also measured. The results show that NH{sub 4}MgPO{sub 4}·6H{sub 2}O is the major hydration product and beneficial to strength development of MPC at hydration temperature below 70 °C. NH{sub 4}MgPO{sub 4}·H{sub 2}O is another major product, which significantly decreases the strength, when the temperature is higher than a critical temperature between 70 °C and 75 °C. NH{sub 4}MgPO{sub 4}·H{sub 2}O can directly form in the MPC paste, and comes from the decomposition of NH{sub 4}MgPO{sub 4}·6H{sub 2}O when the temperature is above 75 °C. With temperature elevation and duration extension, NH{sub 4}MgPO{sub 4}·6H{sub 2}O decomposes rapidly, and even entirely when the temperature is above 100 °C. The borate content has no effect on the types of major hydration products and the critical temperature.

36 MATERIALS SCIENCE↗

Micro- and nano-structural evolutions in white Portland cement/pulverized fuel ash cement pastes due to deionized-water leaching

Thin slices of white Portland cement-low calcium pulverized fuel ash (pfa) blended cement pastes containing 30 or 50% pfa were leached progressively in de-ionized water. The paste with 50% pfa was aged 13 years prior to leaching and those with 30% pfa were aged 1 and 13 years. Pastes were leached for up to 75 days and were characterized using thermal analysis, X-ray diffraction, analytical scanning and transmission electron microscopy, and solid-state nuclear magnetic resonance spectroscopy. Leaching affected the pastes in the following sequence: (i) crystals of Ca(OH){sub 2} large enough to be resolved by backscattered electron imaging were removed completely prior to any effect on C-A-S-H; (ii) the Ca/Si ratio of C-A-S-H reduced from ≈ 1.4 to ≈ 1.0 whilst the aluminosilicate structure was unaffected; (iii) further reduction in the Ca/Si ratio of C-A-S-H was accompanied by lengthening of the aluminosilicate chains; (iv) the Ca/Si ratio of C-A-S-H reduced ultimately to ≈ 0.6.

36 MATERIALS SCIENCE↗

Experimental analysis of an oblique turbulent flame front propagating in a stratified flow

This paper details the experimental study of a turbulent V-shaped flame expanding in a nonhomogeneous premixed flow. Its aim is to characterize the effects of stratification on turbulent flame characteristics. The setup consists of a stationary V-shaped flame stabilized on a rod and expanding freely in a lean premixed methane-air flow. One of the two oblique fronts interacts with a stratified slice, which has an equivalence ratio close to one and a thickness greater than that of the flame front. Several techniques such as PIV and CH{sup *} chemiluminescence are used to investigate the instantaneous fields, while laser Doppler anemometry and thermocouples are combined with a concentration probe to provide information on the mean fields. First, in order to provide a reference, the homogeneous turbulent case is studied. Next, the stratified turbulent premixed flame is investigated. Results show significant modifications of the whole flame and of the velocity field upstream of the flame front. The analysis of the geometric properties of the stratified flame indicates an increase in flame brush thickness, closely related to the local equivalence ratio. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical explosive mode analysis for a turbulent lifted ethylene jet flame in highly-heated coflow

The recently developed method of chemical explosive mode (CEM) analysis (CEMA) was extended and employed to identify the detailed structure and stabilization mechanism of a turbulent lifted ethylene jet flame in heated coflowing air, obtained by a 3-D direct numerical simulation (DNS). It is shown that CEM is a critical feature in ignition as well as extinction phenomena, and as such the presence of a CEM can be utilized in general as a marker of explosive, or pre-ignition, mixtures. CEMA was first demonstrated in 0-D reactors including auto-ignition and perfectly stirred reactors, which are typical homogeneous ignition and extinction applications, respectively, and in 1-D premixed laminar flames of ethylene–air. It is then employed to analyze a 2-D spanwise slice extracted from the 3-D DNS data. The flame structure was clearly visualized with CEMA, while it is more difficult to discern from conventional computational diagnostic methods using individual species concentrations or temperature. Auto-ignition is identified as the dominant stabilization mechanism for the present turbulent lifted ethylene jet flame, and the contribution of dominant chemical species and reactions to the local CEM in different flame zones is quantified. A 22-species reduced mechanism with high accuracy for ethylene–air was developed from the detailed University of Southern California (USC) mechanism for the present simulation and analysis.

Energy & Fuels↗

Energy efficiency in industrial drying: A hybrid ultrasonic system with a novel dynamic optimization framework

Drying processes are among the most energy-consuming operations in industrial and manufacturing settings, demanding strategic selection, design, and control for enhanced efficiency. Advancing drying technologies is critical for improving sustainability, lowering energy use, reducing carbon emissions, and minimizing waste. This study explores two innovative strategies aimed at transforming drying processes into sustainable, low-carbon systems by reducing energy consumption, minimizing waste, and maintaining a strong emphasis on preserving product quality. The first strategy showcases a sub-pilot scale hybrid ultrasonic-convective dryer for agrifood products. This technology, powered by electricity (process electrification), integrates non-thermal ultrasonic dehydration with convective heating and is presented as a sustainable and energy-efficient solution that enhances eco-friendly practices. The second strategy involves introducing and implementing a novel, multiobjective, mixed integer dynamic optimization technique to determine the optimal time-dependent process parameter values for the drying operation. This optimization technique yields operating conditions that are piecewise constant in time aiming to maximize the energy efficiency of the hybrid ultrasonic-convective dryer while ensuring strict adherence to product quality constraints. By adopting the hybrid ultrasonic-convective dryer, a notable 35% improvement in energy efficiency was achieved compared to conventional hot-air drying systems for drying apple slices. The proposed optimization framework further enhanced energy efficiency by nearly 14% over the most efficient process on the identical testbed, under static operating conditions. The reported enhancements have been experimentally validated. Regarding drying time (thereby improving production yield), the developed hybrid ultrasonic-convective dryer demonstrates as much as a 41% reduction in total processing time, which is further optimized by an additional 10% using our proposed optimization framework. The research outcomes have profound implications for the design and operation of drying systems, encompassing crucial aspects such as process electrification, cost-effectiveness, energy savings, time efficiency, product yield, product quality, and process automation.

Dynamic optimization↗

An experimental investigation of gas fuel injection with X-ray radiography

In this paper, an outward-opening compressed natural gas, direct injection fuel injector has been studied with single-shot x-ray radiography. Three dimensional simulations have also been performed to compliment the x-ray data. Argon was used as a surrogate gas for experimental and safety reasons. This technique allows the acquisition of a quantitative mapping of the ensemble-average and standard deviation of the projected density throughout the injection event. Two dimensional, ensemble average and standard deviation data are presented to investigate the quasi-steady-state behavior of the jet. Upstream of the stagnation zone, minimal shot-to-shot variation is observed. Downstream of the stagnation zone, bulk mixing is observed as the jet transitions to a subsonic turbulent jet. From the time averaged data, individual slices at all downstream locations are extracted and an Abel inversion was performed to compute the radial density distribution, which was interpolated to create three dimensional visualizations. The Abel reconstructions reveal that upstream of the stagnation zone, the gas forms an annulus with high argon density and large density gradients. Inside this annulus, a recirculation region with low argon density exists. Downstream, the jet transitions to a fully turbulent jet with Gaussian argon density distributions. This experimental data is intended to serve as a quantitative benchmark for simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Split radiographic tracer technique to measure the full width of a high energy density mixing layer

In this work, we describe a new radiography–based technique for measuring the width of the mixing layer that develops when high–energy–density (HED) fluids of different density mix at an interface. In a traditional radiography target, the denser material includes an embedded, density–matched, high opacity, tracer layer to focus the radiograph on a 2D slice of the 3D flow field. The high opacity layer enhances the contrast between the dense and light materials that permits a clear identification of the spike front, i.e. penetration of the dense material into the light material, but obscures the bubble front, i.e. penetration of the light material into the heavy when the fluids are highly interpenetrated, as in a turbulent mixing layer. On the other hand, removing the tracer layer makes it difficult to identify the interface at all, due to poor contrast and an increased susceptibility to edge effects. Our solution is a split tracer approach where half the target uses the traditional geometry while the other half utilizes a special tracer layer in the light material to produce a radiograph with inverse x-ray opacity characteristics when backlit at a specified x–ray energy. Hydrodynamic equivalency is maintained between the two halves of the target. By making a single target with the traditional and inverse material pairs set side-by-side, we are able to simultaneously measure the penetration of bubbles and spikes in a deeply nonlinear flow, yielding the full mix width. We discuss this new target concept and present our first experiments at the National Ignition Facility (NIF) demonstrating the viability of this technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative wood–adhesive penetration with X-ray computed tomography

Micro X-ray computed tomography (XCT) was used to analyze the 3D adhesive penetration behavior of different wood–adhesive bondlines. Three adhesives, a phenol formaldehyde (PF), a polymeric diphenylmethane diisocyanate (pMDI), and a hybrid polyvinyl acetate (PVA), all tagged with iodine for enhanced X-ray attenuation, were used to prepare single-bondline laminates in two softwoods, Douglas-fir and loblolly pine, and one hardwood, a hybrid polar. Adhesive penetration depth was measured with two separate calculations, and results were compared with 2D fluorescent micrographs. A total of 54 XCT scans were collected, representing six replicates of each treatment type; each replicate, however, consisted of approximately 1500 individual, cross-section slices stacked along the specimen length. As these adhesives were highly modified, the presented results do not indicate typical behavior for their broader adhesive classes. Still, clear penetration differences were observed between each adhesive type, and between wood species bonded with both the PF and pMDI adhesives. Furthermore, penetration results depended on the calculation method used. Two adhesive types with noticeably different resin distributions in the cured bondline, showed relatively similar penetration depths when calculated with a traditional effective penetration equation. However, when the same data was calculated with a weighted penetration calculation, which accounts for both adhesive area and depth, the results appeared to better represent the different distributions depicted in the photomicrographs and tomograms. Additionally, individual replicate comparisons showed variation due to specimen anatomy, not easily observed or interpreted from 2D images. Finally, 3D views of segmented 3D adhesive phases offered unique, in-situ views of the cured adhesive structures. In particular, voids formed by CO 2 bubbles generated during pMDI cure were clearly visible in penetrated columns of the solidified adhesive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Perfusion Computed Tomography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Rectal Cancer

Purpose: To compare pretreatment scans with perfusion computed tomography (pCT) vs. dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in rectal tumors. Methods and Materials: Nineteen patients diagnosed with rectal cancer were included in this prospective study. All patients underwent both pCT and DCE-MRI. Imaging was performed on a dedicated 40-slice CT-positron emission tomography system and a 3-T MRI system. Dynamic contrast enhancement was measured in tumor tissue and the external iliac artery. Tumor perfusion was quantified in terms of pharmacokinetic parameters: transfer constant K{sup trans}, fractional extravascular-extracellular space v{sub e}, and fractional plasma volume v{sub p}. Pharmacokinetic parameter values and their heterogeneity (by 80% quantile value) were compared between pCT and DCE-MRI. Results: Tumor K{sup trans} values correlated significantly for the voxel-by-voxel-derived median (Kendall's tau correlation, tau = 0.81, p < 0.001) and 80% quantile (tau = 0.54, p = 0.04), as well as for the averaged uptake (tau = 0.58, p = 0.03). However, no significant correlations were found for v{sub e} and v{sub p} derived from the voxel-by-voxel-derived median and 80% quantile and derived from the averaged uptake curves. Conclusions: This study demonstrated for the first time that pCT provides K{sup trans} values comparable to those of DCE-MRI. However, no correlation was found for the v{sub e} and v{sub p} parameters between CT and MRI. Computed tomography can serve as an alternative modality to MRI for the in vivo evaluation of tumor angiogenesis in terms of the transfer constant K{sup trans}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Respiratory-Gated and Respiratory-Ungated Planning in Scattered Carbon Ion Beam Treatment of the Pancreas Using Four-Dimensional Computed Tomography

Purpose: We compared respiratory-gated and respiratory-ungated treatment strategies using four-dimensional (4D) scattered carbon ion beam distribution in pancreatic 4D computed tomography (CT) datasets. Methods and Materials: Seven inpatients with pancreatic tumors underwent 4DCT scanning under free-breathing conditions using a rapidly rotating cone-beam CT, which was integrated with a 256-slice detector, in cine mode. Two types of bolus for gated and ungated treatment were designed to cover the planning target volume (PTV) using 4DCT datasets in a 30% duty cycle around exhalation and a single respiratory cycle, respectively. Carbon ion beam distribution for each strategy was calculated as a function of respiratory phase by applying the compensating bolus to 4DCT at the respective phases. Smearing was not applied to the bolus, but consideration was given to drill diameter. The accumulated dose distributions were calculated by applying deformable registration and calculating the dose-volume histogram. Results: Doses to normal tissues in gated treatment were minimized mainly on the inferior aspect, which thereby minimized excessive doses to normal tissues. Over 95% of the dose, however, was delivered to the clinical target volume at all phases for both treatment strategies. Maximum doses to the duodenum and pancreas averaged across all patients were 43.1/43.1 GyE (ungated/gated) and 43.2/43.2 GyE (ungated/gated), respectively. Conclusions: Although gated treatment minimized excessive dosing to normal tissue, the difference between treatment strategies was small. Respiratory gating may not always be required in pancreatic treatment as long as dose distribution is assessed. Any application of our results to clinical use should be undertaken only after discussion with oncologists, particularly with regard to radiotherapy combined with chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atlas-Based Semiautomatic Target Volume Definition (CTV) for Head-and-Neck Tumors

Purpose: To develop a new semiautomatic method to improve target delineation in head-and-neck cancer. Methods and Materials: We implemented an atlas-based software program using fourteen anatomic landmarks as well as the most superior and inferior computerd tomography slices for automatic target delineation, using an advanced laryngeal carcinoma as an example. Registration was made by an affine transformation. Evaluation was performed with manually drawn contours for comparison. Three physicians sampled and further applied a target volume atlas to ten other computer tomography data sets. In addition, a rapid three-dimensional (3D) correction program was developed. Results: The mean time to the first semiautomatic target delineation proposal was 2.7 minutes. Manual contouring required 20.2 minutes per target, whereas semiautomatic target volume definition with the rapid 3D correction was completed in only 9.7 minutes. The net calculation time for image registration of the target volume atlas was negligible (approximately 0.6 seconds). Our method depicted a sufficient adaptation of the target volume atlas on the new data sets, with a mean similarity index of 77.2%. The similarity index increased up to 85% after 3D correction performed by the physicians. Conclusions: We have developed a new, feasible method for semiautomatic contouring that saves a significant amount (51.8%) of target delineation time for head-and-neck cancer patients. This approach uses a target volume atlas and a landmark model. The software was evaluated by means of laryngeal cancer but has important implications for various tumor types whereby target volumes remain constant in form and do not move with respiration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer

Purpose: The aim of this study was to characterize the levels of artifacts and distortions of titanium applicators on 3.0-Tesla magnetic resonance imaging (MRI). Methods and Materials: Fletcher-Suit-Delclos-style tandem and ovoids (T and O) and tandem and ring applicator (T and R) were examined. The quality assurance (QA) phantoms for each applicator were designed and filled with copper sulphate solution (1.5 g/l). The artifacts were quantified with the registration of corresponding computed tomography (CT) images. A favorable MR sequence was searched in terms of artifacts. Using the sequence, the artifacts were determined. The geometric distortions induced by the applicators were quantified through each registration of CT and MRI without applicators. The artifacts of T and O were also evaluated on in vivo MRI datasets of 5 patients. Results: T1-weighted MRI with 1-mm slice thickness was found as a favorable MR sequence. Applying the sequence, the artifacts at the tandem tip of T and O and T and R were determined as 1.5 {+-} 0.5 mm in a superior direction in phantom studies. In the ovoids of T and O, we found artifacts less than 1.5 {+-} 0.5 mm. The artifacts of a T and O tandem in vivo were found as less than 2.6 {+-} 1.3 mm on T1-weighted MRI, whereas less than 6.9 {+-} 3.4 mm on T2-weighted MRI. No more than 1.2 {+-} 0.6 mm (3.0 {+-} 1.5 mm) of distortions, due to a titanium applicator, were measured on T1-weighted MRI (T2-). Conclusion: In 3.0-Tesla MRI, we found the artifact widths at the tip of tandem were less than 1.5 {+-} 0.5 mm for both T and O and T and R when using T1-weighted MRI in phantom studies. However, exclusive 3.0-Tesla MRI-guided brachytherapy planning with a titanium applicator should be cautiously implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Microscopic Disease in Oral Tongue Cancer Using Whole-Mount Histopathologic Techniques: Implications for the Management of Head-and-Neck Cancers

Purpose: To map the distribution of microscopic disease (MD) in head-and-neck cancer by analyzing digital images of whole-mounted serial sections of tongue cancer specimens. Methods and Materials: Ten T1-3 oral tongue cancer specimens were evaluated. The specimens were sliced into 3-mm blocks from which one or more 4-{mu}m slides were taken and digitized to create whole-mounted serial sections. Gross tumor and microscopic disease were digitally contoured on each slide. Lines perpendicular to the gross tumor volume (GTV) edge were created at 0.05-mm intervals and the distance between GTV and MD measured. Results: Of 88 slides assessed, 44 (50%) had evidence of MD. Of the 63,809 perpendicular lines drawn along the GTV edges, 2320 (3.6%) encountered microscopic disease along their path. The majority of MD abutted the GTV, and only 26.7% was noncontiguous with the GTV edge. The maximum distance from the border was 7.8 mm. Ninety-nine percent of all MD was within 4.75 mm and 95% was within 3.95 mm of the GTV. Conclusion: In this study we were able to assess the distribution of MD more accurately than has been possible with routine pathologic techniques. The results indicate that when the GTV is correctly identified, there is very little MD to be found outside this volume. This has implications for the volume of tissue resected at surgery and the volume included in the clinical target volume in conformal radiotherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progression of Non-Small-Cell Lung Cancer During the Interval Before Stereotactic Body Radiotherapy

Purpose: To investigate the relationship between waiting time (WT) and disease progression in patients undergoing stereotactic body radiotherapy (SBRT) for lung adenocarcinoma (AD) or squamous cell carcinoma (SQ). Methods and Materials: 201 patients with Stage I AD or SQ undergoing SBRT between January 2004 and June 2010 were analyzed. The WT was defined as the interval between diagnostic computed tomography before referral and computed tomography for treatment planning or positioning before SBRT. Tumor size was measured on the slice of the longest tumor diameter, and tumor volume was calculated from the longest diameter and the diameter perpendicular to it. Changes in tumor volume and TNM stage progression were evaluated, and volume doubling time (VDT) was estimated. Results: The median WT was 42 days (range, 5-323 days). There was a correlation between WT and rate of increase in volume in both AD and SQ. The median VDTs of AD and SQ were 170 and 93 days, respectively. Thirty-six tumors (23%) did not show volume increase during WTs >25 days. In 41 patients waiting for {<=}4 weeks, no patient showed T stage progression, whereas in 25 of 120 (21%) patients waiting for >4 weeks, T stage progressed from T1 to T2 (p = 0.001). In 10 of 110 (9.1%) T1 ADs and 15 of 51 (29%) T1 SQs, T stage progressed (p = 0.002). N stage and M stage progressions were not observed. Conclusion: Generally, a WT of {<=}4 weeks seems to be acceptable. The WT seems to be more important in SQ than in AD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Macroscopic Pathology Measurements With Magnetic Resonance Imaging and Assessment of Microscopic Pathology Extension for Colorectal Liver Metastases

Purpose: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. Methods and Materials: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapy treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. Results: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (r{sub s} = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (r{sub s} = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (r{sub s} = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (r{sub s} = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. Conclusions: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗