Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Strategies for mitigating the ionization-induced beam head erosion problem in an electron-beam-driven plasma wakefield accelerator

Strategies for mitigating ionization-induced beam head erosion in an electron-beam-driven plasma wakefield accelerator (PWFA) are explored when the plasma and the wake are both formed by the transverse electric field of the beam itself. Beam head erosion can occur in a preformed plasma because of a lack of focusing force from the wake at the rising edge (head) of the beam due to the finite inertia of the electrons. When the plasma is produced by field ionization from the space charge field of the beam, the head erosion is significantly exacerbated due to the gradual recession (in the beam frame) of the 100% ionization contour. Beam particles in front of the ionization front cannot be focused (guided) causing them to expand as in vacuum. When they expand, the location of the ionization front recedes such that even more beam particles are completely unguided. Eventually this process terminates the wake formation prematurely, i.e., well before the beam is depleted of its energy. Ionization-induced head erosion can be mitigated by controlling the beam parameters (emittance, charge, and energy) and/or the plasma conditions. In this paper we explore how the latter can be optimized so as to extend the beam propagation distance and thereby increase the energy gain. In particular we show that, by using a combination of the alkali atoms of the lowest practical ionization potential (Cs) for plasma formation and a precursor laser pulse to generate a narrow plasma filament in front of the beam, the head erosion rate can be dramatically reduced. Simulation results show that in the upcoming “two-bunch PWFA experiments” on the FACET facility at SLAC national accelerator laboratory the energy gain of the trailing beam can be up to 10 times larger for the given parameters when employing these techniques. Comparison of the effect of beam head erosion in preformed and ionization produced plasmas is also presented.

43 PARTICLE ACCELERATORS↗

Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics

The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.

Yadav, M. [University of California, Los Angeles, ↗

Linac Coherent Light Source data analysis using psana

Psana ( Photon Science Analysis ) is a software package that is used to analyze data produced by the Linac Coherent Light Source X-ray free-electron laser at the SLAC National Accelerator Laboratory. The project began in 2011, is written primarily in C++ with some Python, and provides user interfaces in both C++ and Python. Most users use the Python interface. The same code can be run in real time while data are being taken as well as offline, executing on many nodes/cores using MPI for parallelization. It is publicly available and installable on the RHEL5/6/7 operating systems.

Damiani, D.↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

A new synchrotron rapid-scanning X-ray fluorescence (SRS-XRF) imaging station at SSRL beamline 6-2

This paper describes a new large-range rapid-scan X-ray fluorescence (XRF) imaging station at beamline 6-2 at the Stanford Synchrotron Radiation Lightsource at SLAC National Accelerator Laboratory. This station uses a continuous rapid-scan system with a scan range of 1000 × 600 mm and a load capacity of up to 25 kg, capable of 25–100 µm resolution elemental XRF mapping and X-ray absorption spectroscopy (XAS) of a wide range of objects. XRF is measured using a four-element Hitachi Vortex ME4 silicon drift detector coupled to a Quantum Detectors Xspress3 multi-channel analyzer system. A custom system allows the X-ray spot size to be changed quickly and easily via pinholes ranging from 25 to 100 µm, and the use of a poly-capillary or axially symmetric achromatic optic may achieve a <10 µm resolution in the future. The instrument is located at wiggler beamline 6-2 which has an energy range of 2.1–17 keV, creating K emission for elements up to strontium, and L or M emission for all other elements. XAS can also be performed at selected sample positions within the same experiment, allowing for a more detailed chemical characterization of the elements of interest. Furthermore, sparse excitation energy XRF imaging can be performed over a wide range of incident X-ray energies. User friendliness has been emphasized in all stages of the experiment, including versatile sample mounts, He purged chambers for low- Z analyses, and intuitive visualization hardware and software. The station provides analysis capabilities for a wide range of materials and research fields including biological, chemical, environmental and materials science, paleontology, geology and cultural heritage.

47 OTHER INSTRUMENTATION↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Expression, purification and crystallization of CTB-MPR, a candidate mucosal vaccine component against HIV-1

CTB-MPR is a fusion protein between the B subunit of cholera toxin (CTB) and the membrane-proximal region of gp41 (MPR), the transmembrane envelope protein of Human immunodeficiency virus 1 (HIV-1), and has previously been shown to induce the production of anti-HIV-1 antibodies with antiviral functions. To further improve the design of this candidate vaccine, X-ray crystallography experiments were performed to obtain structural information about this fusion protein. Several variants of CTB-MPR were designed, constructed and recombinantly expressed in Escherichia coli . The first variant contained a flexible GPGP linker between CTB and MPR, and yielded crystals that diffracted to a resolution of 2.3 Å, but only the CTB region was detected in the electron-density map. A second variant, in which the CTB was directly attached to MPR, was shown to destabilize pentamer formation. A third construct containing a polyalanine linker between CTB and MPR proved to stabilize the pentameric form of the protein during purification. The purification procedure was shown to produce a homogeneously pure and monodisperse sample for crystallization. Initial crystallization experiments led to pseudo-crystals which were ordered in only two dimensions and were disordered in the third dimension. Nanocrystals obtained using the same precipitant showed promising X-ray diffraction to 5 Å resolution in femtosecond nanocrystallography experiments at the Linac Coherent Light Source at the SLAC National Accelerator Laboratory. The results demonstrate the utility of femtosecond X-ray crystallography to enable structural analysis based on nano/microcrystals of a protein for which no macroscopic crystals ordered in three dimensions have been observed before.

Lee, Ho-Hsien↗

Correlation analysis on real-time tab-delimited network monitoring data

End-End performance monitoring in the Internet, also called PingER is a part of SLAC National Accelerator Laboratory’s research project. It was created to answer the growing need to monitor network both to analyze current performance and to designate resources to optimize execution between research centers, and the universities and institutes co-operating on present and future operations. The monitoring support reflects the broad geographical area of the collaborations and requires a comprehensive number of research and financial channels. The data architecture retrieval and methodology of the interpretation have emerged over numerous years. Analyzing this data is the main challenge due to its high volume. Finally, by using correlation analysis, we can make crucial conclusions about how the network data affects the performance of the hosts and how it depends from countries to countries.

97 MATHEMATICS AND COMPUTING↗

Detecting Anomalies from End-to-End Internet Performance Measurements (PingER) Using Cluster Based Local Outlier Factor

PingER (Ping End-to-End Reporting) is a worldwide end-to-end Internet performance measurement framework. It was developed by the SLAC National Accelerator Laboratory, Stanford, USA and running from the last 20 years. It has more than 700 monitoring agents and remote sites which monitor the performance of Internet links around 170 countries of the world. At present, the size of the compressed PingER data set is about 60 GB comprising of 100,000 flat files. The data is publicly available for valuable Internet performance analyses. However, the data sets suffer from missing values and anomalies due to congestion, bottleneck links, queuing overflow, network software misconfiguration, hardware failure, cable cuts, and social upheavals. Therefore, the objective of this paper is to detect such performance drops or spikes labeled as anomalies or outliers for the PingER data set. In the proposed approach, the raw text files of the data set are transformed into a PingER dimensional model. The missing values are imputed using the k-NN algorithm. The data is partitioned into similar instances using the k-means clustering algorithm. Afterward, clustering is integrated with the Local Outlier Factor (LOF) using the Cluster Based Local Outlier Factor (CBLOF) algorithm to detect the anomalies or outliers from the PingER data. Lastly, anomalies are further analyzed to identify the time frame and location of the hosts generating the major percentage of the anomalies in the PingER data set ranging from 1998 to 2016.

97 MATHEMATICS AND COMPUTING↗

Internet Performance Analysis of South Asian Countries Using End-to-End Internet Performance Measurements

Internet performance is highly correlated with key economic development metrics of a region. According to World Bank, the economic growth of a country increases 1.3% with a 10% increase in the speed of the Internet. Therefore, it is necessary to monitor and understand the performance of the Internet links in the region. It helps to figure out the infrastructural inefficiencies, poor resource allocation, and routing issues in the region. Moreover, it provides healthy suggestions for future upgrades. Therefore, the objective of this paper is to understand the Internet performance and routing infrastructure of South Asian countries in comparison to the developed world and neighboring countries using end-to-end Internet performance measurements. The South Asian countries comprise nearly 32% of the Internet users in Asia and nearly 16% of the world. The Internet performance metrics in the region are collected through the PingER framework. The framework is developed by the SLAC National Accelerator Laboratory, USA and is running for the last 20 years. PingER has 16 monitoring nodes in the region, and in the last year PingER monitors about 40 sites in South Asia using the ubiquitous ping facility. The collected data is used to estimate the key Internet performance metrics of South Asian countries. The performance metrics are compared with the neighboring countries and the developed world. Particularly, the TCP throughput of the countries is also correlated with different development indices. Further, worldwide Internet connectivity and routing patterns of the countries are investigated to figure out the inconsistencies in the region. Furthermore, the performance analysis revealed that the South Asia region is 7-10 years behind the developed regions of North America (USA and Canada), Europe, and East Asia.

97 MATHEMATICS AND COMPUTING↗

Retrofitting the 5045 Klystron for Higher Efficiency

The 5045 klystron has been in production and accelerating particles at SLAC National Accelerator Laboratory for over 25 years. Although the design has undergone some changes there are still significant opportunities for improvement in performance. Retrofitting the 5045 for higher efficiencies and a more mono-energetic spent beam profile is presented.

43 PARTICLE ACCELERATORS↗

Advances in Multi-Physics Modeling for Parallel Finite Element Code Suite ACE3P

SLAC developed ACE3P code suite is a comprehensive set of parallel finite-element codes for multi-physics modeling of particle accelerators. Running on massively parallel computer platforms for high fidelity and high accuracy simulation, ACE3P enables rapid virtual prototyping of accelerator and RF component design, optimization and analysis. Furthermore, recent advances of ACE3P have been focused on the implementation of advanced numerical algorithms, enhancement of multi-physics capabilities, and improvement of code performance on state-of-the-art high performance computing (HPC) platforms for large-scale RF modeling in accelerator applications and beyond. In this paper, we will present a nonlinear electromagnetic (EM) eigensolver for damping calculation of resonant modes for cavities coupled with waveguides, the thermal solver for accurate evaluation of heat loads in superconducting RF (SRF) cavity power coupler, the elastic solver for investigation of SRF cavity cryomodule (CM) bowing due to thermal effect, the frequency domain mechanical solver for studying SRF cavity mechanical oscillation modes, the particle tracking code for dark current simulation in SRF CM using a hybrid MPI+OpenMP parallel programing model, the time domain solver for high fidelity modeling of EM wave propagation for medical device in human body.

97 MATHEMATICS AND COMPUTING↗

First Soft X-ray Quantum Efficiency Measurements on Microwave Annealed Thin-Entrance Window Sensors

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. In addition, there are other light sources such as the FERMI, EuXFEL, and FLASH XFELs, as well as numerous synchrotrons such as the ALS, where soft x-ray science would benefit from detectors with higher quantum efficiency in the 20 eV to 1.5KeV range.A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. Previously, SRP and SIMS measurements were used to characterize the shallow dopant profile, and sensors with the new entrance window process were deployed successfully to measure an Fe-55 x-ray spectrum. For the first time, we present quantum efficiency measurement for soft x-rays. Furthermore, the resulting estimate of the entrance window is 20nm for an arsenic implanted entrance window and 55nm for a boron implanted entrance window.

47 OTHER INSTRUMENTATION↗

Thin-Entrance Window Sensors for Soft X-rays at LCLS-II

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. Here, a new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high resistivity silicon sensors.

47 OTHER INSTRUMENTATION↗