Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Comparison of Supervised and Un-Supervised Machine Learning Algorithms for Threat Detection and Scintillator Performance for Radiation Portal Monitoring

Following the events of September 11, 2001, international border crossing have been equipped with radiation portal monitors (RPMs) to identify illicit radioactive material. Polyvinyl toluene (PVT) scintillators are commonly used due to their low cost and reasonable maintainability, however they offer low spectral resolution. Despite the fact that over twenty years has transpired since this event, radioisotopes are still typically identified by hand-crafted classification algorithms, e.g., total counts or energy windowing, and exhibit relatively poor performance in detecting threats at the low false alarm rates required to support the stream of commerce. While some improvement to performance has been realized via the use of supervised machine learning, these classification algorithms typically utilize simulations in lieu of real data due to the sparsity of data for one or more classes. Accordingly, the performance of these algorithms is somewhat less than optimal when examining experiments or simulations with model mismatch. Consequently, in this work, we examine the application of a number of unsupervised machine learning, anomaly detection based algorithms, to circumvent the inverse crime when analyzing spectroscopy data for RPMs. We also compare anomaly detection results with those obtained via the use of supervised classification detection ML algorithms when model mismatch is introduced between the simulated threat items utilized for training/testing. Finally, we compared the performance of the PVT scintillators to those obtained with higher resolution detectors using both anomaly detection and supervised classification algorithms.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Systematic study of radioluminescence and light propagation effects in scintillating nanoguide materials

Nanoguide optical waveguides are thermally processed materials based on polymers that have different refractive indices. Scintillating versions of these materials have been under development since 2019 and feature PMMA as the low refractive index constituent and Organic Glass Scintillator-polymer blends as the high index component. Characterization efforts to date have focused on the functional characteristics of nanoguide pertaining to its envisioned use in high-resolution transmission radiography applications.

36 MATERIALS SCIENCE↗

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

3D Projection Scintillator Tracker in the DUNE Near Detector

One of the main purposes of the Deep Underground Neutrino Experiment (DUNE) is to measure the CP-violationphase in long-baseline neutrino oscillations with a liquid argon detector of unprecedented size.In order to constrain the systematic uncertainties from the flux, neutrino interaction cross section, energy scale and so on, a near detector is needed to measure the un-oscillated neutrino spectra. In the near detector complex, a three dimensional projection scintillator tracker, also called 3DST, located downstream ofthe liquid-argon detector, is proposed and being studied. 3DST is comprisedof a large number of 1 cm x 1 cm x 1cm scintillator cubes. We expect this tracker to have full solidangle coverage for charged particles, as well as good energy and angular resolutions.3DST provides a unique opportunity of carbon cross section and flux measurements in DUNE,and a great potential of neutron tagging and nuclear effect extraction in the neutrino interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

C$^{7}$LYC: A New Scintillator for Fast Neutron Spectroscopy

The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI{sub 2}(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI{sub 2} crystals with volumes >10 cm{sup 3}. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI{sub 2}(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development of SrI{sub 2}(Eu) detectors for national security purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated readout of organic scintillator and ZnS:Ag/6LiF for segmented antineutrino detectors.

Antineutrino detection using inverse beta decay conversion has demonstrated the capability to measure nuclear reactor power and fissile material content for nuclear safeguards. Current efforts focus on aboveground deployment scenarios, for which highly efficient capture and identification of neutrons is needed to measure the anticipated antineutrino event rates in an elevated background environment. In this submission, we report on initial characterization of a new scintillation-based segmented design that uses layers of ZnS:Ag/{sup 6}LiF and an integrated readout technique to capture and identify neutrons created in the inverse beta decay reaction. Laboratory studies with multiple organic scintillator and ZnS:Ag/{sup 6}LiF configurations reliably identify {sup 6}Li neutron captures in 60 cm-long segments using pulse shape discrimination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated readout of organic scintillator and ZnS:Ag/6LiF for segmented antineutrino detectors.

Antineutrino detection using inverse beta decay conversion has demonstrated the capability to measure nuclear reactor power and fissile material content for nuclear safeguards. Current efforts focus on aboveground deployment scenarios, for which highly efficient capture and identification of neutrons is needed to measure the anticipated antineutrino event rates in an elevated background environment. In this submission, we report on initial characterization of a new scintillation-based segmented design that uses layers of ZnS:Ag/{sup 6}LiF and an integrated readout technique to capture and identify neutrons created in the inverse beta decay reaction. Laboratory studies with multiple organic scintillator and ZnS:Ag/{sup 6}LiF configurations reliably identify {sup 6}Li neutron captures in 60 cm-long segments using pulse shape discrimination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lithium-loaded liquid scintillators

The invention is directed to a liquid scintillating composition containing (i) one or more non-polar organic solvents; (ii) (lithium-6)-containing nanoparticles having a size of up to 10 nm and surface-capped by hydrophobic molecules; and (iii) one or more fluorophores. The invention is also directed to a liquid scintillator containing the above composition.

47 OTHER INSTRUMENTATION↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI2(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI2 crystals with volumes >10 cm3. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI2(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development

Sturm, Benjamin↗

Latest advances in large diameter SrI:Eu and CLYC:Ce scintillators for isotope identification

Scintillator crystal detectors form the basis for many radiation detection devices. Therefore, a search for high light yield single crystal scintillators with improved energy resolution, large volume, and the potential for low cost, is an ongoing process that has increased in recent years due to a large demand in the area of nuclear isotope identification. Alkaline earth halides, elpasolites and rare earth halides are very interesting because many compositions from these crystal families provide efficient Ce3+/ Eu2+ luminescence, good proportionality and good energy resolution. They also have small band-gap leading to higher light yields. Ce3+and Eu2+ are efficient, and the emission wavelengths in the 350-500 nm region matches well with PMTs and a new generation of Siphotodiodes. In this

Hawrami, Rastgo↗

High effective atomic number polymer scintillators for gamma ray spectroscopy

A scintillator material according to one embodiment includes a bismuth-loaded aromatic polymer having an energy resolution at 662 keV of less than about 10%. A scintillator material according to another embodiment includes a bismuth-loaded aromatic polymer having a fluor incorporated therewith and an energy resolution at 662 keV of less than about 10%. Additional systems and methods are also presented.

36 MATERIALS SCIENCE↗

Hygroscopicity Evaluation of Halide Scintillators

A collaborative study of relative hygroscopicity of anhydrous halide scintillators grown at various laboratories is presented. We have developed a technique to evaluate moisture sensitivity of both raw materials and grown crystals, in which the moisture absorption rate is measured using a gravimetric analysis. Degradation of the scintillation performance was investigated by recording gamma-ray spectra and monitoring the photopeak position, count rate and energy resolution. The accompanying physical degradation of the samples exposed to ambient atmosphere was photographically recorded as well. The results were compared with ben

Zhuravleva, M↗

Scintillators and applications thereof

Scintillators of various constructions and methods of making and using the same are provided. In some embodiments, a scintillator comprises at least one radiation absorption region and at least one spatially discrete radiative exciton recombination region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid metal organic scintillator materials system and particle detector

We describe the preparation and characterization of two zinc hybrid luminescent structures based on the flexible and emissive linker molecule, trans-(4-R,4'-R') stilbene, where R and R' are mono- or poly-coordinating groups, which retain their luminescence within these solid materials. For example, reaction of trans-4,4'-stilbenedicarboxylic acid and zinc nitrate in the solvent dimethylformamide (DMF) yielded a dense 2-D network featuring zinc in both octahedral and tetrahedral coordination environments connected by trans-stilbene links. Similar reaction in diethylformamide (DEF) at higher temperatures resulted in a porous, 3-D framework structure consisting of two interpenetrating cubic lattices, each featuring basic to zinc carboxylate vertices joined by trans-stilbene, analogous to the isoreticular MOF (IRMOF) series. We demonstrate that the optical properties of both embodiments correlate directly with the local ligand environments observed in the crystal structures. We further demonstrate that these materials produce high luminescent response to proton radiation and high radiation tolerance relative to prior scintillators. These features can be used to create sophisticated scintillating detection sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗