Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Secondary Ion Mass Spectrometry Bias on Isotope Ratios in Dolomite-Ankerite, Part I: δ 18 O Matrix Effects

Here, we document the development of a suite of carbonate mineral reference materials for calibrating SIMS determinations of δ 18 O in samples with compositions along the dolomite–ankerite solid solution series [CaMg(CO 3 ) 2 –CaFe(CO 3 ) 2 ]. Under routine operating conditions for the analysis of carbonates for δ 18 O with an IMS 1280 instrument (at WiscSIMS, University of Wisconsin, Madison), the magnitude of instrumental bias along the dolomite–ankerite series decreased exponentially by ~ 10‰ with increasing Fe-content in the dolomite structure, but appeared insensitive to minor Mn substitution (< 2.6 mol% Mn/(Ca+Mg+Fe+Mn)). The compositional dependence of bias (i.e., the sample matrix effect) was calibrated using the Hill equation, which relates bias to the Fe# of dolomite–ankerite (i.e., molar Fe/(Mg+Fe)) for thirteen reference materials (Fe# = 0.004–0.789); for calibrations employing either 10 or 3 μm diameter spot size measurements, this yielded residual values ≤ 0.3–0.4‰ relative to CRM NBS 19 for most reference materials in the suite. Analytical precision was ± 0.3‰ (2s) for 10-μm spots and ± 0.7‰ (2s) for 3-μm spots, based on the spot-to-spot repeatability of a drift monitor material that ‘bracketed’ each set of ten sample spot analyses. Analytical uncertainty for individual sample analyses was approximated by a combination of precision and calibration residual values (propagated in quadrature), suggesting an uncertainty of ± 0.5‰ (2s) for 10-μm spots and ± 1‰ (2s) for 3-μm spots.

58 GEOSCIENCES↗

Algae Tile Data: 2004-2007, BPA-51; Preliminary Report, October 28, 2008.

Multiple files containing 2004 through 2007 Tile Chlorophyll data for the Kootenai River sites designated as: KR1, KR2, KR3, KR4 (Downriver) and KR6, KR7, KR9, KR9.1, KR10, KR11, KR12, KR13, KR14 (Upriver) were received by SCS. For a complete description of the sites covered, please refer to http://ktoi.scsnetw.com. To maintain consistency with the previous SCS algae reports, all analyses were carried out separately for the Upriver and Downriver categories, as defined in the aforementioned paragraph. The Upriver designation, however, now includes three additional sites, KR11, KR12, and the nutrient addition site, KR9.1. Summary statistics and information on the four responses, chlorophyll a, chlorophyll a Accrual Rate, Total Chlorophyll, and Total Chlorophyll Accrual Rate are presented in Print Out 2. Computations were carried out separately for each river position (Upriver and Downriver) and year. For example, the Downriver position in 2004 showed an average Chlorophyll a level of 25.5 mg with a standard deviation of 21.4 and minimum and maximum values of 3.1 and 196 mg, respectively. The Upriver data in 2004 showed a lower overall average chlorophyll a level at 2.23 mg with a lower standard deviation (3.6) and minimum and maximum values of (0.13 and 28.7, respectively). A more comprehensive summary of each variable and position is given in Print Out 3. This lists the information above as well as other summary information such as the variance, standard error, various percentiles and extreme values. Using the 2004 Downriver Chlorophyll a as an example again, the variance of this data was 459.3 and the standard error of the mean was 1.55. The median value or 50th percentile was 21.3, meaning 50% of the data fell above and below this value. It should be noted that this value is somewhat different than the mean of 25.5. This is an indication that the frequency distribution of the data is not symmetrical (skewed). The skewness statistic, listed as part of the first section of each analysis, quantifies this. In a symmetric distribution, such as a Normal distribution, the skewness value would be 0. The tile chlorophyll data, however, shows larger values. Chlorophyll a, in the 2004 Downriver example, has a skewness statistic of 3.54, which is quite high. In the last section of the summary analysis, the stem and leaf plot graphically demonstrates the asymmetry, showing most of the data centered around 25 with a large value at 196. The final plot is referred to as a normal probability plot and graphically compares the data to a theoretical normal distribution. For chlorophyll a, the data (asterisks) deviate substantially from the theoretical normal distribution (diagonal reference line of pluses), indicating that the data is non-normal. Other response variables in both the Downriver and Upriver categories also indicated skewed distributions. Because the sample size and mean comparison procedures below require symmetrical, normally distributed data, each response in the data set was logarithmically transformed. The logarithmic transformation, in this case, can help mitigate skewness problems. The summary statistics for the four transformed responses (log-ChlorA, log-TotChlor, and log-accrual ) are given in Print Out 4. For the 2004 Downriver Chlorophyll a data, the logarithmic transformation reduced the skewness value to -0.36 and produced a more bell-shaped symmetric frequency distribution. Similar improvements are shown for the remaining variables and river categories. Hence, all subsequent analyses given below are based on logarithmic transformations of the original responses.

13 HYDRO ENERGY↗

Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

The electron affinity of the uranium atom

The results of a combined experimental and computational study of the uranium atom are presented with the aim of determining its electron affinity. Experimentally, the electron affinity of uranium was measured via negative ion photoelectron spectroscopy of the uranium atomic anion, U – . Computationally, the electron affinities of both thorium and uranium were calculated by conducting relativistic coupled-cluster and multi-reference configuration interaction calculations. The experimentally determined value of the electron affinity of the uranium atom was determined to be 0.309 ± 0.025 eV. The computationally predicted electron affinity of uranium based on composite coupled cluster calculations and full four-component spin–orbit coupling was found to be 0.232 eV. Predominately due to a better convergence of the coupled cluster sequence for Th and Th – , the final calculated electron affinity of Th, 0.565 eV, was in much better agreement with the accurate experimental value of 0.608 eV. In both scenarios, the ground state of the anion corresponds to electron attachment to the 6d orbital.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chroma Shift and Gamut Shape: Going Beyond Average Color Fidelity and Gamut Area

Though sometimes referred to as a two-measure system for evaluating color rendition, IES TM-30-15 includes other key components that go beyond the high-level average values IES Rf and IES Rg. This article focuses on the Color Vector Graphic and Local Chroma Shift (IES Rcs,hj), discussing the calculation methods for these evaluation tools and providing context for the interpretation of the values. It also presents alternatives for quantifying the same characteristics, which can inform the development of future measures. The Color Vector Graphic (CVG) is a visual representation of hue and chroma shifts across different hues. It quickly communicates complex information about how object colors will be rendered by a light source, although it is difficult or impossible to use for writing a specification. CVGs demonstrate that increases in chroma for certain hues sometimes means a decrease in chroma for other hues, and illustrates hue shifts for intermediate colors. The combination of shifts over different hues can be referred to as gamut shape. Complementing this information are the IES Rcs,hj values, which quantify the average relative chroma shift for samples in each of the 16 hue-angle bins (j) specified in IES TM-30-15. Unlike measures of average color fidelity and gamut area, gamut shape and hue-specific chroma shift are new concepts with no directly-comparable historical references. It will be critical to incorporate the Color Vector Graphic and Local Chroma Shift values into practice because they capture information about color rendition that is impossible to describe with average measures (such as CIE Ra, IES Rf, or IES Rg), but that is critical to understanding human evaluations of color quality in architectural environments.

Chroma Shift↗

Multiple Maize Reference Genomes Impact the Identification of Variants by Genome-Wide Association Study in a Diverse Inbred Panel

Use of a single reference genome for genome-wide association studies (GWAS) limits the gene space represented to that of a single accession. This limitation can complicate identification and characterization of genes located within presence–absence variations (PAVs). In this study, we present the draft de novo genome assembly of ‘PHJ89’, an ‘Oh43’-type inbred line of maize (Zea mays L.). From three separate reference genome assemblies (‘B73’, ‘PH207’, and PHJ89) that represent the predominant germplasm groups of maize, we generated three separate whole-seedling gene expression profiles and single nucleotide polymorphism (SNP) matrices from a panel of 942 diverse inbred lines. We identified 34,447 (B73), 39,672 (PH207), and 37,436 (PHJ89) transcripts that are not present in the respective reference genome assemblies. Genome-wide association studies were conducted in the 942 inbred panel with both the SNP and expression data values to map Sugarcane mosaic virus (SCMV) resistance. Highlighting the impact of alternative reference genomes in gene discovery, the GWAS results for SCMV resistance with expression values as a surrogate measure of PAV resulted in robust detection of the physical location of a known resistance gene when the B73 reference that contains the gene was used, but not the PH207 reference. This study provides the valuable resource of the Oh43-type PHJ89 genome assembly as well as SNP and expression data for 942 individuals generated from three different reference genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Small Alkaline-Earth-based Core/Shell Nanoparticles for Efficient Upconversion

The optical efficiency of lanthanide-based upconversion is intricately related to the crystalline host lattice. Different crystal fields interacting with the electron clouds of the lanthanides can significantly affect transition probabilities between the energy levels. Here, we investigate six distinct alkaline-earth rare-earth fluoride host materials (M 1- x Ln x F 2+ x , MLnF) for infrared-to-visible upconversion, focusing on nanoparticles of CaYF, CaLuF, SrYF, SrLuF, BaYF, and BaLuF doped with Yb 3+ and Er 3+ . We first synthesize ~5 nm upconverting cores of each material via a thermal decomposition method. Then we introduce a dropwise hot-injection method to grow optically inert MYF shell layers around the active cores. Five distinct shell thicknesses are considered for each host material, resulting in 36 unique, monodisperse upconverting nanomaterials each with size below ~15 nm. The upconversion quantum yield (UCQY) is measured for all core/shell nanoparticles as a function of shell thickness and compared with hexagonal (β-phase) NaGdF 4 , a traditional upconverting host lattice. While the UCQY of core nanoparticles is below the detection limit (<10-5%), it increases by 4 to 5 orders of magnitude as the shell thickness approaches 4-6 nm. The UCQY values of our cubic MLnF nanoparticles meet or exceed the β-NaGdF 4 reference sample. Across all core/shell samples, SrLuF nanoparticles are the most efficient, with UCQY values of 0.53% at 80 W/cm 2 for cubic nanoparticles with ~11 nm edge length. This efficiency is 5 times higher than our β-NaGdF 4 reference material with comparable core size and shell thickness. Our work demonstrates efficient and bright upconversion in ultrasmall alkaline-earth-based nanoparticles, with applications spanning biological imaging and optical sensing.

36 MATERIALS SCIENCE↗

Documentation for the machine-readable version of the Perth 70: A catalogue of positions of 24900 stars tape B, mean values of the observation

The Perth 70 catalog contains accurate positions of 24978 stars, plus other useful data such as approximate proper motions, radial velocities, and parallaxes. The Perth 70 is a result of meridian circle observations made by the Hamburg observatory expedition to Perth as part of the international effort of Southern References Stars (SRS). Tape B, which contains mean values of the observations and corresponds to the printed catalog is described.

Warren, W. H., Jr.↗

Retrieving Point Cloud of Cloud Points (PCCP) Value-Added Product from Stereo Cameras

In this report, we refer to a pair of cameras that capture synchronized pictures with overlapping fields of view (FOV) as a stereo pair. Each stereo pair independently performs a stereo reconstruction of cloud points. Currently, there are three U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility stereo pairs (six cameras in total) positioned around the Southern Great Plains (SGP) observatory’s Central Facility (CF; Romps and Oktem 2017). Time-synchronized pictures from the two cameras in a stereo pair can be paired together to obtain a three-dimensional (3D) reconstruction of feature points by triangulation. This document explains how we use ARM stereo cameras and stereophotogrammetric principles to generate the Point Cloud of Cloud Points (PCCP) Value-Added Product (VAP). The PCCP VAP is essentially a set of 3D positions representing the locations of cloud features in the sky. Thousands of cloud features can be reconstructed instantly in each stereo pair's FOV, which covers an area of tens of square kilometers. Cloud base and cloud top heights can be extracted from the PCCP product.

42 ENGINEERING↗

FLOWERS AEP: An Analytical Model for Wind Farm Layout Optimization

Annual energy production (AEP) is commonly used in objective functions for wind farm layout optimization. AEP is proportional to wind farm power production integrated over an annual distribution of free-stream wind conditions. Physics-based estimates of wind farm power production typically rely on low-fidelity engineering wake models that approximate the steady-state wind farm flow field. AEP estimates are then obtained by performing independent simulations for discrete wind conditions and using rectangular quadrature to account for each condition's expected frequency of occurrence. Depending on the number of simulated discrete wind conditions, this numerical integral could be hampered by poor accuracy or high computational costs. The FLOWERS AEP model instead poses an analytical integral of the engineering wake model over the variable wind conditions, yielding a closed-form, analytical function for wind farm AEP. This paper derives the analytical functions for FLOWERS AEP and its derivatives with respect to turbine position, which are useful for gradient-based wind farm layout optimization, in nondimensional form. We then analyze the benefits of the FLOWERS AEP model over conventional reference models, focusing on its low cost, adequate wake loss predictions, and smooth design space. Although the FLOWERS approach is found to predict the exact value of AEP with some error relative to the reference model (within 14% on average), it dramatically reduces computation time by an order of magnitude, produces a qualitatively similar design space at relatively low resolution, and yields comparable optimal layouts. This significant speed improvement is critical in layout optimization applications, where determining an optimal layout in an efficient manner is more important than precise AEP prediction.

17 WIND ENERGY↗

Re-Additization of Commercial Biodiesel Blends During Long-Term Storage

Commercial biodiesel blends representative of the U.S. market were aged following procedure ASTM D4625, Standard Test Method for Middle Distillate Fuel Storage Stability at 43°C (110°F), with periodic monitoring of fuel properties indicative of oxidation. The oxidation stability—or oxidation reserve expressed as Rancimat induction period (IP)—gradually decreased from its initial value, as expected. At a predetermined IP threshold, an antioxidant was used to restore IP to the ASTM D7467 specification minimum of 6 six hours, referred to as re-additization. At lower IP values, the amount of antioxidant required increased significantly, and the effectiveness tended to be reduced. Once IP fell to essentially zero, the acid content increased to above the allowable limit. Insoluble material was detectable after the acid number increased out of specification. Storage life was increased with re-additization relative to the as-received fuels, as evidenced by longer time to produce acids. Experience in the field may vary based on storage conditions; however, these results indicate re-additization can significantly increase the storage life of biodiesel blends when used with regular monitoring of IP and acid number. An assessment of property changes during long-term storage showed the initial IP did not predict storage behavior, although fuels above the specification minimum remained stable for greater than 12 weeks of D4625 accelerated aging (1 one year simulated).

09 BIOMASS FUELS↗

SU-F-T-01: Optimization of the Accelerated Partial Breast Brachytherapy Fractionation with Consideration of Physical Doses to Tumor and Organ at Risk

Purpose: The accelerated partial breast irradiation (APBI) with brachytherapy prescribes 34Gy to be delivered in 10 fractions over 5 consecutive working days without considering the physical dose to the target and organs at risk (OARs) for an individual patient. The purpose of this study is to optimize the fractionation scheme by evaluating the radiation effect on tumor and OARs with a modified linear-quadratic (LQ) model based on dose-volume histograms (DVHs). Methods: Five breast patients treated with multilumen balloon brachytherapy were selected. The minimum skin and rib spacing were ranged from 2.5mm to 14.3mm and from 1.0mm to 25.0mm, respectively. The LQ model parameters were set as: (1) breast: α=0.08, β=0.028, doubling time Tpot=14.4 days, and starting time Tk=21days; (2) skin: acute reaction α=0.101, β=0.009; late reaction α=0.064, β=0.029; (3) rib: α=0.3, β=0.12. Boundary dose Dt was 6 Gy for both target and OARs. The relation between radiation effects on the tumor (ET) and OARs (EOAR) were plotted for fraction number from 1 to 20. Results: The value of radiation effect from routine 3.4Gyx10 fractions was used as reference, ETref and EOARref. If set ET=ETref, the fractionation that results in minimum EOAR values correspond to the optimal fractionation. For these patients, the optimal numbers are 10 fractions for skin acute reaction, 18 fractions for skin and rib late reaction while the doses per fraction are 3.4Gy and 2.05–2.10Gy, respectively. If set EOAR=EOARref, the fractionation that results in a maximum ET value corresponds to the optimal fractionation. The optimal fractionation is 3.4Gyx10 fractions for skin acute reaction, and 2.10–2.25Gyx18 fractions for skin late reaction and rib. Conclusion: For APBI brachytherapy, the routine 3.4Gyx10 fractions is optimal fractionation for skin acute reaction, while 2.05–2.25Gyx18 fractions is optimal fractionation for late reaction of skin and rib.

60 APPLIED LIFE SCIENCES↗

A full CI treatment of the 1A1, 1B1, and 3B1 states of SiH2

Full CI calculations are presented for the 1A1, 3B1, and 1B1 states of SiH2 at their respective equilibrium geometries and at geometries with the SiH bonds stretched. These results are compared with those obtained from single-reference and multireference CI calculations. The computed Te values agree well with the full CI results, provided that the effects of higher-than-double excitations are accounted for either by the Davidson correction or by a multireference approach. When the SiH bonds are stretched, the single-reference methods are not sufficiently flexible, and only CASSCF/MRCI achieves chemical accuracy (i.e., agrees with the full CI to 1 kcal/mol). Overall, the accuracy of the various approximate methods is very similar to that found for H2O, NH2, and CH2.

Bauschlicher, Charles W., Jr.↗

A {gamma} dose distribution evaluation technique using the k-d tree for nearest neighbor searching

Purpose: The authors propose an algorithm based on the k-d tree for nearest neighbor searching to improve the {gamma} calculation time for 2D and 3D dose distributions. Methods: The {gamma} calculation method has been widely used for comparisons of dose distributions in clinical treatment plans and quality assurances. By specifying the acceptable dose and distance-to-agreement criteria, the method provides quantitative measurement of the agreement between the reference and evaluation dose distributions. The {gamma} value indicates the acceptability. In regions where {gamma}{<=}1, the predefined criterion is satisfied and thus the agreement is acceptable; otherwise, the agreement fails. Although the concept of the method is not complicated and a quick naieve implementation is straightforward, an efficient and robust implementation is not trivial. Recent algorithms based on exhaustive searching within a maximum radius, the geometric Euclidean distance, and the table lookup method have been proposed to improve the computational time for multidimensional dose distributions. Motivated by the fact that the least searching time for finding a nearest neighbor can be an O(log N) operation with a k-d tree, where N is the total number of the dose points, the authors propose an algorithm based on the k-d tree for the {gamma} evaluation in this work. Results: In the experiment, the authors found that the average k-d tree construction time per reference point is O(log N), while the nearest neighbor searching time per evaluation point is proportional to O(N{sup 1/k}), where k is between 2 and 3 for two-dimensional and three-dimensional dose distributions, respectively. Conclusions: Comparing with other algorithms such as exhaustive search and sorted list O(N), the k-d tree algorithm for {gamma} evaluation is much more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Locally adaptive artificial viscosity strategies for Lagrangian hydrodynamics

To accurately model inviscid flow with shock waves using staggered-grid Lagrangian hydrodynamics, artificial viscosity is introduced to convert kinetic energy into internal energy, thereby providing a mechanism to generate the required entropy increase across shocks. In this paper, we propose a new method for constructing an adaptive, artificial viscosity in the context of one-dimensional, staggered-grid Lagrangian hydrodynamics. Our adaptive, artificial viscosity is defined in terms of two parameters that depend on density locally in a neighborhood around a shock, and hence, vary cell-by-cell. Our methodology is based on building a reference set of pre-computed optimal, globally constant artificial viscosity coefficients for a family of isolated shock test problems. For arbitrary flows, the evaluation of the unknown coefficients is automated by first estimating shock intensity locally, and second computing the corresponding adaptive parameter value via interpolation over the data from the pre-computed reference set of optimal, globally constant coefficient values. To illustrate the performance of our new approach, we compare our results against two existing methods. The first method is a limiter-based approach, which relies on estimating velocity gradients of the flow, and the second method is utilized in several commercial codes. Finally, we demonstrate that our new adaptive methodology produces more accurate results for a variety of tests with propagating shock waves, as well as for the aforementioned family of isolated shock problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary assessment of stable nitrogen and oxygen isotopic composition of USGS51 and USGS52 nitrous oxide reference gases and perspectives on calibration needs

Rationale: Despite a long history and growing interest in isotopic analyses of N 2 O, there is a lack of isotopically characterized N 2 O isotopic reference materials (standards) to enable normalization and reporting of isotope-delta values. Here, in this paper we report the isotopic characterization of two pure N 2 O gas reference materials, USGS51 and USGS52, which are now available for laboratory calibration (https://isotopes.usgs.gov/lab/referencematerials.html). Methods: A total of 400 sealed borosilicate glass tubes of each N 2 O reference gas were prepared from a single gas filling of a high vacuum line. We demonstrated isotopic homogeneity via dual-inlet isotope-ratio mass spectrometry. Isotopic analyses of these reference materials were obtained from eight laboratories to evaluate interlaboratory variation and provide preliminary isotopic characterization of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and site preference (S P ) values. Results: The isotopic homogeneity of both USGS51 and USGS52 was demonstrated by one-sigma standard deviations associated with the determinations of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and S P values of 0.12 mUr or better. The one-sigma standard deviations of SP measurements of USGS51 and USGS52 reported by eight laboratories participating in the interlaboratory comparison were 1.27 and 1.78 mUr, respectively. Conclusions: The agreement of isotope-delta values obtained in the interlaboratory comparison was not sufficient to provide reliable accurate isotope measurement values for USGS51 and USGS52. Lastly, we propose that provisional values for the isotopic composition of USGS51 and USGS52 determined at the Tokyo Institute of Technology can be adopted for normalizing and reporting sample data until further refinements are achieved through additional calibration efforts.

54 ENVIRONMENTAL SCIENCES↗

Comparison of several classical density functional theories for the adsorption of flexible chain molecules into cylindrical nanopores

Adsorption of flexible oligomers into narrow cylindrical pores has been studied by means of several versions of classical density functional theory (CDFT) and Monte Carlo simulation. The adsorption process is interesting to study due to the competition between the entropic depletion of oligomers from the pores and the wall–oligomer attraction. It is also challenging to describe using current CDFTs, which tend to overestimate the amount of the adsorbed fluid. From a comparison of several different CDFT approaches, we find that this is due to the assumption of ideal or freely jointed chain conformations. Moreover, it is demonstrated that it is impossible to obtain a reasonable description of the adsorption isotherms without taking into account accurate contact values in the distribution functions describing the structure of the reference monomer fluid. At low densities, more accurate result are obtained in comparison with Monte Carlo simulation data when accurate contact values are incorporated into the theory rather than the more commonly used hard-sphere contact value. However, even the CDFT with accurate contact values still overestimates the amount of the adsorbed fluid due to the ideal or freely jointed chain approximation, used for the description of chain conformations in most CDFT approaches. We find that significant improvement can achieved by employing self-consistent field theory, which samples self-avoiding chain conformations and decreases the number of possible chain conformations, and, consequently, the amount of the adsorbed fluid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗