Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Flammable Gas Generation and Control at the Idaho Completion Project Legacy Combustible Gas Generation - 20191

On April 11, 2018, four drums containing transuranic waste at the Idaho National Laboratory underwent over-pressurization, ejecting their lids and spreading radiological waste within a facility. An investigation has found that waste in the drums generated methane gas, which contributed to the event. Subsequent to the investigation, the potential for drums to have methane and other flammable analytes whose concentrations could approach or exceed the lower flammability limit (LFL) and the adequacy of the controls to prevent or mitigate a possible deflagration was evaluated. An extensive review of the historical records was performed to determine how many drums exceed the LFL. The historical record identified a small quantity of drums that exceeded the LFL for xylene, hydrogen, and methane. The primary codified applicable code or standard for handling drums is 29 CFR 1910.120 (j) 'Handling Drums and Containers.' It is used throughout the commercial and government sector. This code is integrated throughout the Fluor Idaho safety management programs and procedures to control the Standard Industrial Hazards (SIHs) associated with drum and container handling. Example requirements include: - Drums and containers are inspected, and their integrity assured prior to being moved. - Site operations are organized to minimize the amount of drum or container movement. - When there is a reasonable possibility of flammable atmospheres being present, material handling equipment and hand tools are of the type to prevent sources of ignition. Drums and containers under pressure, as evidenced by bulging or swelling, are not moved until the cause for excess pressure is determined and appropriate containment procedures have been implemented to protect employees from explosive relief of the drum. Drums which exceed the WIPP FGA limit have NCRs associated with them. Once a drum fails flammable gas sampling, an NCR is initiated. The NCR drives placement into NCR dense pack rows. A standing order drives placement of the FGA failures to a single planer segregation location. These drums are not allowed for further processing or shipment until the NCR has been cleared. Once in the single planer rows, follow-up FGA testing is performed by CCP. The NCR is dispositioned by follow-up sampling occurring after adequate time has been provided for the gas to diffuse through the filter assembly, or, in some cases, the drums are repackaged into additional drums to reduce the source term. To date, the ICP project has performed approximately 1.5 million drums moves without a deflagration event due to combustible gas generation. Flammable gas generation in a transuranic waste drum is not unique to the ICP but is common across the DOE complex. Based on the experience at Idaho, application of industry standards is sufficient to control the risk of drum deflagration due to drum movements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2019 LANL Radionuclide Air Emissions Report

In June 2020, Los Alamos National Laboratory (LANL) submitted letter ESHQSS: 20-025 to Region 6 of the Unites States Environmental Protection Agency (EPA). This letter transmitted the 2019 LANL Radionuclide Air Emissions Report to the EPA. This report summarizes LANL operations, air emissions of radionuclides, and subsequent off-site dose consequence from these emissions for calendar year 2019. This report is issued to meet requirements of 40 CFR 61 Subpart H, National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Facilities. This regulation, called the Radionuclide NESHAP, establishes a limit of 10 millirem per year to the maximally exposed member of the public and requires an annual report to be submitted to the appropriate EPA Region by June 30th of each year. LANL’s off-site dose from airborne emissions of radionuclides in 2019 was 0.43 millirem. The normal practice is to issue this report directly to EPA Region 6 in June of each year, and then after the report is accepted by the EPA, re-issue the report for inclusion in the LANL Electronic Public Reading Room (EPRR). This second part is usually done in July of each year, but this step was overlooked in July 2020 due to other commitments. We regret this error. This omission was noted in late 2020; we are submitting the 2019 LANL Radionuclide Air Emissions Report to the EPRR now in December 2020. Aside from the addition of this cover sheet explaining the delay, the report is unchanged from the version submitted to EPA Region 6 in June.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Certifying the Performance of Fixative Technologies under Open Air Demolition Activities for D and D - 20096

Department of Energy (DOE) facilities undergoing deactivation and decommissioning (D and D) activities struggle with safety concerns of residual radioactive contamination leftover after gross decontamination efforts have concluded. The positive effects of implementing fixative technologies for decommissioning and maintenance is known across the DOE complex. However, there is no standardized metric in place that quantifies the performance of these technologies such as incombustible fixative platforms that immobilize the contamination in a solid polymer material under normal operating conditions or when exposed to stressors. The primary focus of this research is to provide the empirical data necessary to properly characterize the effects of implementing fixative technologies on mitigating the release of contamination. In addition, this effort has been used to identify and establish uniform testing protocols to quantify operational parameters of fixating platforms and properly credit such systems under a variety of operational conditions and stressors that can arise during open air demolition efforts (e.g. impact, water, thermal, etc.). The established protocols will be provided to the ASTM International E10.03 Subcommittee on Radiological Protection for Decontamination and Decommissioning of Nuclear Facilities and Components for the potential of formal standardization. Attributes to be addressed during testing are material compromise from impact stress, thermal stress for incombustible fixative materials, and immobilization factors (how well an immobilizing platform is capable of retaining fixated material during thermal and impact stressors). In developing these test methods, a greater understanding of the material's behavior under anticipated and unanticipated events, such as decommissioning activities and contingency events as outlined in the Basis of Interim Operations (BIO), can be successfully characterized. There are several key components of the experimental methodology that is essential in empirically certifying fixative technologies. A surrogate contaminant with a unique signature has been utilized with the implementation of a uniform contamination process of test coupons that is quantifiable and replicable for direct fixative comparisons. A modular test chamber has also been used to apply the various stressors of interest. Collection of released contamination that includes airborne and resettled contaminant particles and analyzed using mass spectrometry. This research directly supports DOE complex-wide concerns in terms of final disposition of nuclear facilities and the considerations made during their time between ceasing facility operation and final disposition. The results of this effort aims to provide a standardized road map and logical decision flow to better facilitate fixative technologies into D and D activities required to achieve the desired facility end state. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Notice of Submittal – 2023 Radionuclide Air Emissions Report for Los Alamos National Laboratory

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2023 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.43 for 2023. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2023, LANL continuously monitored radionuclide emissions at 28 “major” release points, or stacks. The Laboratory estimates emissions from an additional 59 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2023, this MEI location was a business at 129 New Mexico State Road 4 (NM-4), located in the northern end of White Rock. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2023 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2022 LANL Radionuclide Air Emissions Report (Rev. 2)

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2022 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.45 for 2022. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2022, LANL continuously monitored radionuclide emissions at 27 “major” release points, or stacks. The Laboratory estimates emissions from an additional 34 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2022, this MEI location was a business at 95 Entrada Drive, located in the eastern end of Los Alamos town site. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with radioactive gas emissions from the LANSCE facility and the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2022 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pathogenetic validation of the use of biological protective agents and early treatment in cases of radiation injury simulating radiation effects under space flight conditions

In considering a radiation safety system for space flights, the various measures to protect man against radiation include drug prophylaxis. At the present time a great deal of experimental material has been accumulated on the prevention and treatment of radiation injuries. Antiradiation effectiveness has been established for sulfur- and nitrogen-containing substances, auxins, cyanides, polynucleotides, mucopolysaccharides, lipopolysaccharides, aminosaccharides, synthetic polymers, vitamins, hormones, amino acids and other compounds which can be divided into two basic groups - biological and chemical protective agents.

Rogozkin, V. D.↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Regulation and Practical Implementation of Analyses of Inadvertent Human Intrusion - 20169

Recommendations from the International Commission for Radiological Protection (ICRP) and the International Atomic Energy Agency (IAEA) identify the need to consider potential inadvertent human intrusion into a near-surface radioactive waste disposal facility when developing limits for radionuclide concentrations that can be disposed. The recommendations also provide perspective on expectations for performance criteria and general assumptions for such analyses. Inadvertent human intrusion analyses are conducted to address the potential failure of institutional controls and loss of memory of a disposal facility. The analyses consider potential consequences of human actions that result in unknowingly bringing waste to the surface. Inadvertent human intrusion scenarios consider potential impacts to someone involved in an activity that actually disturbs the waste (e.g., drilling or excavation of a basement) or that exposes the person to emanations from the waste (e.g., radioactive gases) and also for the case where there may be longer term exposures to waste that has been brought to the surface. In practice, inadvertent human intrusion analyses have proven to be a critical consideration for the development of waste classification systems and for the determination of disposal requirements and limitations on wastes that can be disposed at shallow depths. The IAEA implemented a project on Human Intrusion in the context of Disposal of Radioactive waste (HIDRA) to further explore the regulatory expectations and practical implementation of analyses of potential inadvertent human intrusion. The paper begins with a discussion of international recommendations related to consideration of inadvertent human intrusion and then summarizes examples of some topical considerations related to addressing inadvertent human intrusion that are being discussed as part of the second phase of the HIDRA project. The topical considerations are planned to be addressed in a formal IAEA publication. All information in this paper simply reflects on-going project discussions and no formal recommendations are implied for these topical considerations at this time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗