Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Radiation Tests of the Extravehicular Mobility Unit Space Suit for the International Space Station Using Energetic Protons

Measurements using silicon detectors to characterize the radiation transmitted through the EMU space suit and a human phantom have been performed using 155 and 250 MeV proton beams at LLUMC. The beams simulate radiation encountered in space, where trapped protons having kinetic energies on the order of 100 MeV are copious. Protons with 100 MeV kinetic energy and above can penetrate many centimeters of water or other light materials, so that astronauts exposed to such energetic particles will receive doses to their internal organs. This dose can be enhanced or reduced by shielding - either from the space suit or the self-shielding of the body - but minimization of the risk depends on details of the incident particle flux (in particular the energy spectrum) and on the dose responses of the various critical organs. Data were taken to characterize the beams and to calibrate the detectors using the beam in a treatment room at LLUPTF, in preparation for an experiment with the same beams incident on detectors placed in a human phantom within the EMU suit. Nuclear interactions of high-energy protons in various materials produce a small flux of highly ionizing, low-energy secondary radiation. Secondaries are of interest for their biological effects, since they cause doses and especially dose-equivalents to increase relative to the values expected simply from ionization energy loss along the Bragg curve. Because many secondaries have very short ranges, they are best measured in passive track detectors such as CR-39. The silicon detector data presented here are intended to supplement the CR-39 data in regions where silicon has greater sensitivity, in particular the portion of the LET spectrum below 5 keV/micron. The results obtained in this study suggest that optimizing the radiation shielding properties of space suits is a formidable task. The naive assumption that adding mass can reduce risk is not supported by the data, which show that reducing the dose delivered at or near the skin by low-energy particles may increase the dose delivered by energetic particles to points deeper in the body.

Zeitlin, C.↗

Parallel Study of HEND, RAD, and DAN Instrument Response to Martian Radiation and Surface Conditions

Nuclear detection methods are being used to understand the radiation environment at Mars. JPL (Jet Propulsion Laboratory) assets on Mars include: Orbiter -2001 Mars Odyssey [High Energy Neutron Detector (HEND)]; Mars Science Laboratory Rover -Curiosity [(Radiation Assessment Detector (RAD); Dynamic Albedo Neutron (DAN))]. Spacecraft have instruments able to detect ionizing and non-ionizing radiation. Instrument response on orbit and on the surface of Mars to space weather and local conditions [is discussed] - Data available at NASA-PDS (Planetary Data System).

Mars↗

Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

This interim report consists of four separate reports from our research on the receivers of NASA's Gravity And Magnetic Experiment Satellite (GAMES). The first report is entitled 'Analysis of phase estimation bias of GAMES receiver due to Doppler shift.' The second report is 'Background radiation on GAMES fine ranging detector from the moon, the planets, and the stars.' The third report is 'Background radiation on GAMES receivers from the ocean sun glitter and the direct sun.' The fourth report is 'GAMES receiver performance versus background radiation power on the detectors.'

Davidson, Frederic M.↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

A high-temperature Rutherford Backscattering Spectrometry apparatus for in situ material characterization

A new methodology for high-temperature Rutherford Backscattering Spectrometry (HT-RBS) has been developed to enable in situ material characterization at elevated temperatures. A 3.5 MeV proton beam penetrates a 10-µm-thick 316L stainless steel foil mounted on a graphite substrate, with backscattered signals detected using an HT-RBS system. Conventional semiconductor detectors, primarily based on silicon, suffer significant performance degradation at temperatures higher than ~ 60 °C due to increased leakage current and noise, leading to signal distortion and failure. Here, to preserve spectral quality, a 5 µm aluminum foil shields the detector from thermal radiation, allowing reliable operation up to 900 °C at the target. A rotatable shutter provides additional thermal isolation during data collection pauses. In situ measurements of areal density changes of 316L stainless steel were conducted to validate the technique, revealing consistency with the known thermal expansion coefficient. The method facilitates seamless switching between irradiation and analysis, enabling continuous studies. This approach supports in situ investigations of diffusion, void swelling, creep, and corrosion, offering a versatile tool for advanced materials research.

36 MATERIALS SCIENCE↗

Pixel-Strip Module Testing and Performance Analysis for the CMS Phase-2 Outer Tracker Upgrade

In response to the demanding environment of the High-Luminosity Large Hadron Collider (HL-LHC), the Compact Muon Solenoid (CMS) Experiment's Outer Tracker is being replaced with a lighter, higher-granularity, radiation-tolerant silicon detector capable of providing tracking information directly to the Level-1 trigger system. The new Outer Tracker consists of Pixel-Strip (PS) and Strip-Strip (2S) transverse momentum (pT) modules, which are assembled and tested at, among other centers, Fermilab's Silicon Detector Facility. PS modules consist of a pixel sensor, a strip sensor, and multiple application-specific integrated circuits (ASICs). This poster studies the performance of MaPSAs, silicon macro-pixel sensors bump-bonded to 16 macro-pixel ASICS. It presents the testing procedures for MaPSAs and MaPSA-strip sensor sub-assemblies, as well as the results of calibration and performance studies of two PS modules before and after irradiation. These results assess the impact of irradiation on module performance, providing insight into the modules' expected performance in the HL-LHC environment.

Kimrey, Emerson [Scripps College]↗

A Search for Ultra-high-energy Neutrinos from TXS 0506+056 Using the Pierre Auger Observatory

Results of a search for ultra-high-energy neutrinos with the Pierre Auger Observatory from the direction of the blazar TXS 0506+056 are presented. They were obtained as part of the follow-up that stemmed from the detection of high-energy neutrinos and gamma rays with IceCube, Fermi-LAT, MAGIC, and other detectors of electromagnetic radiation in several bands. The Pierre Auger Observatory is sensitive to neutrinos in the energy range from 100 PeV to 100 EeV and in the zenith-angle range from θ = 60° to θ = 95°, where the zenith angle is measured from the vertical direction. No neutrinos from the direction of TXS 0506+056 have been found. The results were analyzed in three periods: one of 6 months around the detection of IceCube-170922 A, coinciding with a flare period of TXS 0506+056, a second one of 110 days during which the IceCube collaboration found an excess of 13 neutrinos from a direction compatible with TXS 0506+056, and a third one from 2004 January 1 up to 2018 August 31, over which the Pierre Auger Observatory has been taking data. The sensitivity of the Observatory is addressed for different spectral indices by considering the fluxes that would induce a single expected event during the observation period. For indices compatible with those measured by the IceCube collaboration the expected number of neutrinos at the Observatory is well below one. Spectral indices as hard as 1.5 would have to apply in this energy range to expect a single event to have been detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous Millimeter-wave, Gamma-Ray, and Optical Monitoring of the Blazar PKS 2326-502 during a Flaring State

Including millimeter-wave data in multiwavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence millimeter-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these millimeter-wave light curves to those at other wavelengths, in particular γ-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now millimeter-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first 2 yr of this monitoring, and we present a search for evidence of correlated variability between millimeter-wave, optical R-band, and γ-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multiwavelength studies with facilities such as Vera C. Rubin Observatories Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Photovoltaic effect in organic polymer-iodine complex

Certain charge transfer complexes formed from organic polymers and iodine generate appreciable voltages at relatively low impedances upon exposure to light. These films show promise in applications requiring chemically and electrically stable films as detectors of optical radiation and as energy converters in photovoltaic cells.

Hermann, A. M.↗

The analysis of X-ray spectra.

Systematic analysis program for proportional counter X ray spectral observations of celestial objects, considering interaction between radiation field and detector

Garmire, G.↗

Design and construction of a wide angle diffuse source

A Multispectral Scanner (MSS) has been under development for some time and is now undergoing tests for final calibration. It has four bands, each containing six channels. Thus it has 24 detectors which receive radiation by fiber optics. It is shown that a spherical integrator makes a satisfactory extended source for the calibration of the scanner.

Mohr, E. I.↗

RALPH: An online computer program for acquisition and reduction of pulse height data

A background/foreground data acquisition and analysis system incorporating a high level control language was developed for acquiring both singles and dual parameter coincidence data from scintillation detectors at the Radiation Counting Laboratory at the NASA Manned Spacecraft Center in Houston, Texas. The system supports acquisition of gamma ray spectra in a 256 x 256 coincidence matrix (utilizing disk storage) and simultaneous operation of any of several background support and data analysis functions. In addition to special instruments and interfaces, the hardware consists of a PDP-9 with 24K core memory, 256K words of disk storage, and Dectape and Magtape bulk storage.

Davies, R. C.↗

Study of the effects of condensation on the performance of Pioneer Venus probe windows

The transmission loss of Pioneer Venus Probe radiation windows if their exposed surfaces become contaminated with droplets of water, hydrochloric acid, sulfuric acid, and mercury which may be found in the Venusian atmosphere was investigated. Transmission loss was studied as a function of mass concentration of liquid droplets deposited on one surface of test window materials while the wavelength of the transmitting radiation is in the range of 0.3 to 30 microns. The parameters that affect the transmittance of radiation through a window are: (1) particle size, (2) surface concentration of particles, (3) wavelength of the radiation, (4) angle of acceptance of the radiation by the detector, and (5) the refractive index of the aerosol.

Testerman, M. K.↗