Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROBOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Fully Robotic Hot Cell Crane for Target Hall Operations at Isotope Research Facility - 18329

There are many types of equipment used in high radiation environments, but the super-sized and high precision lifting requirements for an isotope research facility in the USA called for one of the largest fully robotic cranes in the US. The 20 Ton Remote Handling Bridge Crane provided by PaR Systems met many challenging requirements for accuracy, repeatability and unique lifting motions in the radiation-shielded target hall of this facility. This robotic system was designed to address four main issues. The first is that the crane needed to be operated remotely due to high radioactivity during the time when it is needed most. Second is that high precision is needed due to the complex fit of multiple heavy shielding blocks. Third problem is that automated routines and exclusion areas were needed due to the remote operation of the system around high capital cost equipment. Lastly is the survivability of the equipment due to the high radiation environment. The facility robotic crane is an overhead top running multiple girder hot cell bridge crane (hereafter referred to as the system). The system is intended to be used in either manually operated or automated operation under computer control. Under automated control, the system provides highly accurate motion control in three linear axes as well as hook rotation. Using motion control programming, this highly accurate system ensures safe, remote movement of in-cell components. The system was designed to be remotely operated by a technician from the remote handling control room in the facility. This is facilitated by computer control using the System Graphical User Interface with feedback from a facility supplied video system. It can also be operated using a wireless hand held controller. The system will be used to place sensitive components with high precision in locations that will be difficult to observe directly. In order to accomplish this, it is critical that the system be capable of moving its payload with minimal swing, and with high accuracy, repeatability and reliability. The system will be operating in an environment where it will be exposed to both high energy neutrons and gamma radiation. Under beam-off conditions, the target hall will be hands-on accessible to accommodate crane maintenance. The system was installed and tested in early 2017 in advance of the live operations of the facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards a Robust System-of-Systems Control Architecture for Robotics - 18359

This paper presents the methodology and results of developing and implementing a system-of-systems architecture for controlling many robotic systems within the context of industrial facilities, where the life of the facility will be far longer than the life of the robotics, due to software updates and accelerated digital obsolescence. The use cases are the JET and ITER fusion research reactors. Remote maintenance is both device defining and mission critical for a future fusion reactor and we foresee the need to utilise a considerable number of robotic devices within an overall digital control architecture. The paper will explore the challenges of long term management of digital complexity using the real experience of JET over the last 20 years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double Shell Tank Integrity Inspection - Integration of Customized Robotics - 18400

28 steel, double-shell, million gallon waste storage tanks located at the Hanford site in Washington State store both radioactive and hazardous waste. To monitor their condition and ensure continued viability, these tanks are inspected periodically through a comprehensive integrity program. In 2012, the first leak in a double-shell tank at Hanford was discovered in the 241-AY tank farm (Tank AY-102) and the failure was observed to be from the primary tank bottom. However, the exact failure location and damage mechanism have not been determined. A decision was made to pursue the capability to inspect the primary tank bottom region in order to provide additional tank integrity information. This work is particularly challenging due to the confined space in the double-shell tank annulus region (i.e. the 30 inch space between the primary and secondary tank shells), the limited dimensions of the tank risers that provide access to the annulus space (risers as small as 10 inches in diameter), and also the very small dimensions of the air channels in the concrete refractory pad that the primary waste storage tank rests on (channels are approximately two inches in diameter). Veolia Nuclear Solutions, along with Key Subcontractor Inuktun, were contracted to provide the capability to conduct these tank inspections in support of Hanford's double-shell tank integrity program. The Veolia Nuclear Solutions /Inuktun team designed, built, tested and delivered a tethered miniature robotic crawler system that utilizes the marsupial approach - a larger deployment crawler positions a smaller inspection crawler. The deployment crawler is installed via the tank riser, is magnetically coupled to the side of the tank shell, and drives to the selected deployment location at the end of one of the refractory channels where the small inspection robot is subsequently deployed. Operation of the equipment is controlled from a trailer outside the tank farm (a distance of several hundred feet). The system design includes a custom mechanism that provides for positioning and cable handling as well as the controls interface (laptop connected via control cables). The solution leveraged the Veolia Nuclear Solutions/Inuktun team's experience with delivering similar modular systems for other US and international sites. This simple but innovative solution delivered on an accelerated project schedule underlines the ability to provide effective robotic solutions to the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Localization Method for Remotely Operated Robot in Harsh Environments - 18561

For decommissioning of the Fukushima Daiichi Nuclear Power Station (FDNPS), the primary containment vessel (PCV) internal survey for fuel debris spreading has been needed. Remotely operated robots have been used for the survey. Localization of the robots during their operation is necessary to adjust sensor positions. However, it is difficult to calculate the robot position because the survey target areas have an unknown environment. In this research, we proposed a localization method which combines a stereo camera-based method for absolute localization and a periodic structure tracking method for relative localization for application to the unknown environment. The position accuracy for the proposed method was verified in a mock-up test, and we confirmed that the position accuracy satisfied the required accuracy of 30 mm. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robot Navigation in a Rich Information Map for Inspection in Nuclear Environments - 18596

This paper discusses our approach of using an unmanned ground vehicle (UGV) to perform inspection tasks in nuclear environments. To reduce people's exposure to the environment with elevated radiation levels, our goal is enabling UGV to navigate and perform inspections fully autonomous with no human getting involved. To achieve the full automation, the UGV can take use of a rich information map. In traditional robot navigation, the 2D global cost map used for planning path consists only obstacle locations, while a rich information map also includes location information of interested objects to robot. The UGV can then use a rich information map to perform routine inspection tasks with known object locations. In this paper, we will present our method of generating a rich information map and the usage of this map for International Atomic Energy Agency (IAEA) Robotics Challenge. (authors)

42 ENGINEERING↗

Trauma Pod: A Semi-Automated Robotic Surgery System

The Trauma Pod (TP) vision is to develop a rapidly deployable robotic system to perform critical acute stabilization and/or surgical procedures autonomously or in a teleoperative mode on wounded soldiers in the battlefield who might otherwise die before treatment in a combat hospital can be provided. In the first phase of a project pursuing this vision, a robotic TP system was developed and its capability demonstrated by performing select surgical procedures on a patient phantom. The system demonstrates the feasibility of performing acute stabilization procedures with the patient being the only human in the surgical cell. The teleoperated surgical robot is supported by autonomous arms that carry out scrub-nurse and circulating-nurse functions. Tool change and supply delivery are performed automatically and at least as fast as those performed manually by nurses. The TP system also includes tomographic X-ray facility for patient diagnosis and 2-D fluoroscopic data to support interventions. The vast amount of clinical protocols generated in the TP system are recorded automatically. These capabilities form the basis for a more comprehensive acute diagnostic and management platform that will provide life-saving care in environments where surgical personnel are not present.

42 ENGINEERING↗

Everybody Needs Somebody Sometimes: Validation of Adaptive Recovery in Robotic Space Operations

This work assesses an adaptive approach to fault recovery in autonomous robotic space operations, which uses indicators of opportunity, such as physiological state measurements and observations of past human assistant performance, to inform future selections. We validated our reinforcement learning approach using data we collected from humans executing simulated mission scenarios. We present a method of structuring human-factors experiments that permits collection of relevant indicator of opportunity and assigned assistance task performance data, as well as evaluation of our adaptive approach, without requiring large numbers of test subjects. Application of our reinforcement learning algorithm to our experimental data shows that our adaptive assistant selection approach can achieve lower cumulative regret compared to existing non-adaptive baseline approaches when using real human data. Our work has applications beyond space robotics to any application where autonomy failures may occur that require external intervention.

Human-centered robotics↗

Technique for Targeting Arteriovenous Malformations Using Frameless Image-Guided Robotic Radiosurgery

Purpose: To integrate three-dimensional (3D) digital rotation angiography (DRA) and two-dimensional (2D) digital subtraction angiography (DSA) imaging into a targeting methodology enabling comprehensive image-guided robotic radiosurgery of arteriovenous malformations (AVMs). Methods and Materials: DRA geometric integrity was evaluated by imaging a phantom with embedded markers. Dedicated DSA acquisition modes with preset C-arm positions were configured. The geometric reproducibility of the presets was determined, and its impact on localization accuracy was evaluated. An imaging protocol composed of anterior-posterior and lateral DSA series in combination with a DRA run without couch displacement between acquisitions was introduced. Software was developed for registration of DSA and DRA (2D-3D) images to correct for: (a) small misalignments of the C-arm with respect to the estimated geometry of the set positions and (b) potential patient motion between image series. Within the software, correlated navigation of registered DRA and DSA images was incorporated to localize AVMs within a 3D image coordinate space. Subsequent treatment planning and delivery followed a standard image-guided robotic radiosurgery process. Results: DRA spatial distortions were typically smaller than 0.3 mm throughout a 145-mm x 145-mm x 145-mm volume. With 2D-3D image registration, localization uncertainties resulting from the achievable reproducibility of the C-arm set positions could be reduced to about 0.2 mm. Overall system-related localization uncertainty within the DRA coordinate space was 0.4 mm. Image-guided frameless robotic radiosurgical treatments with this technique were initiated. Conclusions: The integration of DRA and DSA into the process of nidus localization increases the confidence with which radiosurgical ablation of AVMs can be performed when using only an image-guided technique. Such an approach can increase patient comfort, decrease time pressure on clinical and technical staff, and possibly reduce the number of cerebral angiograms needed for a particular patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of a Robotic 6-Degree of Freedom Treatment Couch for Frameless Radiosurgery

Purpose: To evaluate the added value of 6-degree of freedom (DOF) patient positioning with a robotic couch compared with 4DOF positioning for intracranial lesions and to estimate the immobilization characteristics of the BrainLAB frameless mask (BrainLAB AG, Feldkirchen, Germany), more specifically, the setup errors and intrafraction motion. Methods and Materials: We enrolled 40 patients with 66 brain metastases treated with frameless stereotactic radiosurgery and a 6DOF robotic couch. Patient positioning was performed with the BrainLAB ExacTrac stereoscopic X-ray system. Positioning results were collected before and after treatment to assess patient setup error and intrafraction motion. Existing treatment planning data were loaded and simulated for 4DOF positioning and compared with the 6DOF positioning. The clinical relevance was analyzed by means of the Paddick conformity index and the ratio of prescribed isodose volume covered with 4DOF to that obtained with the 6DOF positioning. Results: The mean three-dimensional setup error before 6DOF correction was 1.91 mm (SD, 1.25 mm). The rotational errors were larger in the longitudinal (mean, 0.23 Degree-Sign ; SD, 0.82 Degree-Sign ) direction compared with the lateral (mean, -0.09 Degree-Sign ; SD, 0.72 Degree-Sign ) and vertical (mean, -0.10 Degree-Sign ; SD, 1.03 Degree-Sign ) directions (p < 0.05). The mean three-dimensional intrafraction shift was 0.58 mm (SD, 0.42 mm). The mean intrafractional rotational errors were comparable for the vertical, longitudinal, and lateral directions: 0.01 Degree-Sign (SD, 0.35 Degree-Sign ), 0.03 Degree-Sign (SD, 0.31 Degree-Sign ), and -0.03 Degree-Sign (SD, 0.33 Degree-Sign ), respectively. The mean conformity index decreased from 0.68 (SD, 0.08) (6DOF) to 0.59 (SD, 0.12) (4DOF) (p < 0.05). A loss of prescribed isodose coverage of 5% (SD, 0.08) was found with the 4DOF positioning (p < 0.05). Half a degree for longitudinal and lateral rotations can be identified as a threshold for coverage loss. Conclusions: With a mask immobilization, patient setup error and intrafraction motions need to be evaluated and corrected for. The 6DOF patient positioning with a 6DOF robotic couch to correct translational and rotational setup errors improves target positioning with respect to treatment isocenter, which is in direct relation with the clinical outcome, compared with the 4DOF positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotic four-dimensional pixel assembly of van der Waals solids

Van der Waals (vdW) solids can be engineered with atomically precise vertical composition through the assembly of layered two-dimensional materials. However, the artisanal assembly of structures from micromechanically exfoliated flakes is not compatible with scalable and rapid manufacturing. Further engineering of vdW solids requires precisely designed and controlled composition over all three spatial dimensions and interlayer rotation. Here, we report a robotic four-dimensional pixel assembly method for manufacturing vdW solids with unprecedented speed, deliberate design, large area and angle control. We used the robotic assembly of prepatterned 'pixels' made from atomically thin two-dimensional components. Wafer-scale two-dimensional material films were grown, patterned through a clean, contact-free process and assembled using engineered adhesive stamps actuated by a high-vacuum robot. We fabricated vdW solids with up to 80 individual layers, consisting of 100 x 100 μm 2 areas with predesigned patterned shapes, laterally/vertically programmed composition and controlled interlayer angle. This enabled efficient optical spectroscopic assays of the vdW solids, revealing new excitonic and absorbance layer dependencies in MoS 2 . Furthermore, we fabricated twisted $N$-layer assemblies, where we observed atomic reconstruction of twisted four-layer WS 2 at high interlayer twist angles of >= 4°. In conclusion, our method enables the rapid manufacturing of atomically resolved quantum materials, which could help realize the full potential of vdW heterostructures as a platform for novel physics and advanced electronic technologies.

42 ENGINEERING↗

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),↗

Goddard Robotic Telescope

We are constructing the 14'' fully automated optical robotic telescope, Goddard Robotic Telescope (GRT), at the Goddard Geophysical and Astronomical Observatory. The aims of our robotic telescope are 1) to follow-up the Swift/Fermi Gamma-Ray Bursts (GRBs) and 2) to perform the coordinated optical observations of the Fermi/Large Area Telescope (LAT) Active Galactic Nuclei (AGN). Our telescope system consists of the 14'' Celestron Optical Telescope Assembly (OTA), the Astro-Physics 1200GTO mount, the Apogee U47 CCD camera, the JMI's electronic focuser, and the Finger Lake Instrumentation's color filter wheel with U, B, V, R and I filters. With the focal reducer, 20'x20' field of view has been achieved. The observatory dome is the Astro Haven's 7 ft clam-shell dome. We started the scientific observations on mid-November 2008. While not observing our primary targets (GRBs and AGNs), we are planning to open our telescope time to the public for having a wider use of our telescope in both a different research field and an educational purpose.

79 ASTRONOMY AND ASTROPHYSICS↗

The RCT 1.3 m robotic telescope: broadband color transformation and extinction calibration

The Robotically Controlled Telescope (RCT) 1.3 m telescope, formerly known as the Kitt Peak National Observatory (KPNO) 50 inch telescope, has been refurbished as a fully robotic telescope, with an autonomous scheduler to take full advantage of the observing site without the requirement of a human presence. Here we detail the current configuration of the RCT and present, as a demonstration of its high-priority science goals, the broadband UBVRI photometric calibration of the optical facility. In summary, we find the linear color transformation and extinction corrections to be consistent with similar optical KPNO facilities, to within a photometric precision of 10% (at 1σ). While there were identified instrumental errors that likely added to the overall uncertainty, associated with since-resolved issues in engineering and maintenance of the robotic facility, a preliminary verification of this calibration gave a good indication that the solution is robust, perhaps to a higher precision than this initial calibration implies. The RCT has been executing regular science operations since 2009 and is largely meeting the science requirements set during its acquisition and redesign.

79 ASTRONOMY AND ASTROPHYSICS↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

NeoN: Neuromorphic Control for Autonomous Robotic Navigation

In this paper we describe the use of a new neuromorphic computing framework to implement the navigation system for a roaming, obstacle avoidance robot. Using a Dynamic Adaptive Neural Network Array (DANNA) structure, our TENNLab (Laboratory of Tennesseans Exploring Neural Networks) hardware/software co-design framework and evolutionary optimization (EO) as the training algorithm, we create, train, implement, and test a spiking neural network autonomous robot control system using an array of neuromorphic computing elements built on an FPGA. The simplicity and flexibility of the DANNA neuromorphic computing elements allow for sufficient scale and connectivity on a Xilinx Kintex-7 FPGA to support sensory input and motor control for a mobile robot to navigate a dynamically changing environment. We further describe how more complex capabilities can be added using the same platform, e.g. object identification and tracking.

Mitchell, J. Parker↗

Design and Integration of a Compact Mobile Outdoor Soil Sampling Agricultural Robot

The lack of feedback on soil management for crop systems necessitates the collection of soil samples to derive insights into prevailing soil conditions. Achieving an accurate model of these plantations requires a substantial number of soil samples, which is a labor-intensive process that can suffer from inconsistencies in both the methodology of collection and the locations from which samples are gathered. In addition, the close spacing of crop rows constrains the maneuverability of mobile agricultural equipment during sample collection. This article proposes the use of agricultural robotics to facilitate the acquisition of composite soil samples with minimal human intervention, allowing for precise data collection for a Populus plant system. More specifically, this article presents a case study on the design and construction of a compact agricultural robot for soil sample collection. The performance of the robot, including its soil collection efficacy, maneuverability, and positional accuracy, is evaluated.

42 ENGINEERING↗

Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗