Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Developmental study of advanced HIS design method for digital I and C+HMIT of PWR plant - 277

A new conceptual frame of how to design and validate a digital HIS (human interface system) on an innovative numerical simulation basis is proposed for the support of plant operators' supervisory control of various types of automated complex NPPs (nuclear power plants). The proposed conceptual framework utilizes the object-oriented software for plant DiD (defense-in depth) risk monitor with the combination of nuclear reactor accident simulation by an advanced nuclear safety analysis code RELAP5/MOD4. The conceptual frame proposed in this paper will be applied for an example practice for the SBLOCA (small break loss of coolant accident) case of passive safety PWR (pressurized water reactor) AP1000. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g{sup -1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power. Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ultrasonic imaging in liquid sodium

The fourth generation of nuclear reactor can use liquid sodium as the core coolant. When the reactor is operating, sodium temperatures can reach up to 600 deg. C. During maintenance periods, when the reactor is shut down, the coolant temperature is reduced to 200 deg. C. Because molten sodium is optically opaque, ultrasonic imaging techniques are developed for maintenance activities. Under-sodium imaging aims at i) checking the health of immersed structures. It should also allow ii) to assess component degradation or damage as cracks and shape defects as well as iii) the detection of lost objects. The under-sodium imaging system has to sustain high temperature (up to 300 deg. C) and hostility of the sodium environment. Furthermore, specific constraints such as transducers characteristics or the limited sensor mobility in the reactor vessel have to be considered. This work focuses on developing a methodology for detecting damages such as crack defects with ultrasound devices. Surface-breaking cracks or deep cracks are sought in the weld area, as welds are more subject to defects. Traditional methods enabled us to detect emerging cracks of submillimeter size with sodium-compatible high-temperature transducer. The presented approach relies on making use of prior knowledge about the environment through the implementation of differential imaging and time-reversal techniques. Indeed, this approach allows to detect a change by comparison with a reference measurement and by focusing back to any change in the environment. It is a means of analysis and understanding of the physical phenomena making it possible to design more effective inspection strategies. Difference between the measured signals reveals the acoustic field scattered by a perturbation (a crack for instance), which may occur between periodical measurements. The imaging method relies on the adequate combination of two computed ultrasonic fields, one forward and one adjoint. The adjoint field, which carries the information about the defects, is analogous to a time-reversal operation. One of the interests of the presented method is that the time-reversal operation is not done experimentally but numerically. Numerical simulations have been carried out to validate the practical relevance of this approach. The preliminary numerical results show a nice agreement between the guessed and the actual positions of the defect. After water-tests, in sodium-tests must be done in order to validate the water/sodium transposition. For this purpose, an under-sodium device is under development, which can move the transducers with four degrees of freedom in a 1.5 m{sup 3} sodium pot. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concrete structural health monitoring in nuclear power plants - 212

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed in order to understand the current condition of a structure based on heterogeneous measurements and produce high-confidence actionable information regarding structural integrity. This information can be used to support operational and maintenance decisions. This paper describes a framework of research activities for health monitoring of nuclear power plant concrete structures. The proposed framework consists of four elements: (1) health monitoring, (2) data analytics, (3) uncertainty quantification, and (4) prognosis. The goal of this framework is to enable plant operators to make risk-informed decisions about structural integrity, remaining useful life, and performance of concrete structures across the nuclear fleet. Among several concrete degradations, research focuses on degradation caused by the alkali-silica reaction (ASR). ASR is a chemical reaction that, in the presence of sufficient moisture, forms a gel that increases in volume and exerts an expansive pressure inside the material, thus causing micro to macro-cracks. This paper also presents development of controlled concrete samples with reactive aggregates to cause ASR degradation and application of different non-destructive evaluation techniques to detect the damage caused by ASR. Initial results are presented in the paper along with a potential path forward. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reactor System Demonstration with Cyber-Attack Scenarios Using CrowPis and Arduino Microcontrollers

This study covers developing and simulating nuclear reactor system using CrowPis and Arduino microcontrollers for demonstrating cyber-attack scenarios. The team was tasked with implementing more sensors and cybersecurity aspects to the reactor program that was created by last year’s high school interns. The team received the opportunity to collaborate and obtain advice from multiple university interns that helped us gain a better perspective of our project. Our mentor’s background in nuclear science was pivotal to our understanding what we could add to the reactor program to make it as realistic as possible. The first week of our internship was spent reading as much material as possible to gain an understanding of and the background for cyber-attacks and nuclear science. Nuclear science was a new horizon for each of the high school interns on the team, so spending this time in the beginning of our internship was crucial to our success. For the remaining portion of our internship, the team collectively did our best to implement as many sensors and use as much hardware as we could to make an accurate representation of a nuclear reactor in the program that was created. This internship was a big learning experience for everyone on the team. We all gained so many insights into the nuclear world and how it can benefit our lives, as well as how so many moving pieces are needed for it to work properly.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of guided wave transmission through complex junction in sodium cooled reactor

Ultrasonic guided wave techniques are seen as suitable candidates for the inspection of welded structures within sodium cooled fast reactors (SFR), as the long range propagation of guided waves without amplitude attenuation can overcome the accessibility problem due to the liquid sodium. In the context of the development of the Advanced Sodium Test Reactor for Industrial Demonstration (ASTRID), the French Atomic Commission (CEA) investigates non-destructive testing techniques based on guided wave propagation. In this work, guided wave NDT methods are applied to control the integrity of welds located in a junction-type structure welded to the main vessel. The method presented in this paper is based on the analysis of scattering matrices peculiar to each expected defect, and takes advantage of the multi-modal and dispersive characteristics of guided wave generation. In a simulation study, an algorithm developed using the CIVA software is presented. It permits selecting appropriate incident modes to optimize detection and identification of expected flawed configurations. In the second part of this paper, experimental results corresponding to a first validation step of the simulation results are presented. The goal of the experiments is to estimate the effectiveness of the incident mode selection in plates. The results show good agreement between experience and simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection rate evaluation of ex-core detectors in the subcritical OPR-1000 reactor

The OPR-1000 is a PWR reactor developed in Korea. One-type ex-core detectors for monitoring of power distributions were installed in the OPR-1000 reactor to alternate the three-types of the ex-core detectors. For the verification of the detection performances, neutron transport calculation was performed by using MCNP5 code. The reaction rate in the ex-core detectors and the neutron flux were evaluated by using MCNP5 code as changing the boron concentration from 1800 ppm to 1122 ppm in the subcritical condition. The reaction rate results in fission chamber show that minimum and maximum values are 0.03577 and 3.33563 reactions/cm{sup 3}-sec, respectively. This study can be directly used for the verification and improvement of fission chamber performance in using one-type ex-core detector. Also, it can be utilized for the production of the reference data in determining neutron source strength. It is expected the proposed simulation method can be utilized to the improvement of the dose monitoring system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of oxygen sensors for use in liquid metal

For generation IV reactor concepts, based on liquid metal cooling, there is a need for robust oxygen sensors which can be used in the core of the reactor since corrosion can only be kept sufficiently low by controlling the dissolved oxygen content in the liquid metal. A robust, ceramic membrane type sensor has been developed at IFE/Halden (Norway) and tested in an autoclave system at KTH (Sweden). The sensor has been tested in lead-bismuth at 550 deg. C and performed well. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On-line measurements of RuO{sub 4} during a PWR severe accident

After the Fukushima accident, it became essential to have a way to monitor in real time the evolution of a nuclear reactor during a severe accident, in order to react efficiently and minimize the industrial, ecological and health consequences of the accident. Among gaseous fission products, the tetroxide of ruthenium RuO{sub 4} is of prime importance since it has a significant radiological impact. Ruthenium is a low volatile fission product but in case of the rupture of the vessel lower head by the molten corium, the air entering into the vessel oxidizes Ru into gaseous RuO{sub 4}, which is not trapped by the Filtered Containment Venting Systems. To monitor the presence of RuO{sub 4} allows making a diagnosis of the core degradation and quantifying the release into the atmosphere. To determine the presence of RuO{sub 4}, FTIR spectrometry was selected. To study the feasibility of the monitoring, high-resolution IR measurements were realized at the French synchrotron facility SOLEIL on the infrared beam line AILES. Thereafter, theoretical calculations were done to simulate the FTIR spectrum to describe the specific IR fingerprint of the molecule for each isotope and based on its partial pressure in the air. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control system design for a small pressurized water reactor - 141

Small Pressurized Water Reactors (SPWR) have unique designs from the commercial large Pressurized Water Reactors (PWRs). Integral design is adopted. There are no hot legs and cold legs between the reactor core and the steam generators like in the PWR. Strong interactions exist among different loops. The pressure vessel is large in volume and the coolant inventory is also in a large amount. The inertia of the coolant is large and it takes more time for the primary system to respond to disturbances. The steam generator adopts the once-through design and the water inventory is small. The steam generator is very sensitive to disturbances. These unique characteristics challenge the control system design of SPWR. Relap5 is used to model the SPWR. Steady-state simulation is performed to verify the correctness of the model. In the reactor power control system, both the reactor fission power and the coolant average temperature are regulated by the control rod reactivity. In the feedwater flow control system, the coordination between the reactor and the turbine is considered and coolant average temperature is adopted as one measurable disturbance for the control system. The coolant pressure is adjusted based on the heaters and spray in the pressurizer. The water level in the pressurizer is controlled by the charging flow and the letdown flow is compensated to calculate the charging flow needed. Transient simulations are carried out to evaluate the control system performance. When the reactor is perturbed, the reactor can be stabilized under the control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A summary comparison of design evaluation techniques - 270

Many nuclear power plants in the United States have recently been granted a 20 year extension to their operation license and are considering modernization. The Idaho National Laboratory is committed to successful modernizations and has been identifying and developing candidate technologies for power plants using methods that match the requirements of an integrated system validation. To do so this paper discusses current and potential workload, situation awareness and other performance methods used in evaluating control room design against the criteria defined by the Nuclear Regulatory Commission. The analysis provided is narrowed to the scope of methods surrounding the Light Water Reactor Sustainability research at the Idaho National Laboratory and therefore evaluates only a handful of the numerous methods used in control room modernizing efforts. As such, it was determined the most popular methods for measuring situation awareness, workload, and performance are measurements that rarely measure their intended construct directly and must be inferred. Physiological measures of workload have matured and become more accessible, sensitive, unobtrusive, valid, and objective but are reliant on variable technology. Situation Awareness measures possess little construct validity but eye-tracking technology is a measure progressing in sensitivity, objectivity, and continues to improve in unobtrusiveness. All things considered, this paper has identified a significant need for a more extensive review of the various performance measures used in modernizing control rooms and integrated system validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feedback of the Dutch Historical Waste Management Program - 17085

This paper provides a feedback on the Dutch historical waste management program. Over the past decades, the High Flux Reactor located in Petten in the province of North Holland has tested numerous types of materials and fuels irradiation, for both medical and nuclear energy applications. A number of waste containers was accumulated on site, where the storage facility was initially built. Following Dutch political decisions in the 1980's, the contents of the waste storage facility in Petten must be transferred to another location. The consequences of this decision included the transportation of waste containers from Petten to the new location, which is located in the South-West of the Netherlands. This project was initiated and is now running. It includes a complex structure and can be described as follows: each historical-waste container will be opened, its contents segregated in three categories depending on the dose rate emission, characterized and repacked in new containers suitable for transportation and storage at the new site. The approach chosen is based on the final dose rate emitted by the repacked containers, which are sub-divided into 3 categories.. The lowest dose-emitting containers are transported directly to the new storage facility. The 2 other categories are first transported to a third party to be super compacted and subsequently transported to the new storage facility. So far, the segregation method is based on Co-60 gamma emission and nuclide vectors associated to the different materials. A pre-sorting has been established to fit as much as possible IAEA recommendations. Historical waste has then to be classified in families sharing common history. Thus, a set of canisters containing the pieces of the old reactor vessel, which was replaced in 1984 was the first challenge, followed by a set of canisters containing residues of instruments only and pieces coming from the top of the control rods of the reactor which were not directly irradiated in the reactor. So far, the two first sets of canisters are being treated and characterized as well as possible. Reporting and official documents have been filled up to comply to Dutch transport regulations and to define waste acceptance criteria for the storage facility. The first transports of containers with Low Level Waste occurred in October 2015, and another transport took place at the end of 2016. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data-driven analysis of ultrasonic pressure tube inspection data - 220

Pressure tubes are critical components of the CANDU reactors and other pressurized heavy water type reactors, as they contain the nuclear fuel and the coolant. Manufacturing flaws, as well as defects developed during the in-service operation, can lead to coolant leakage and can potentially damage the reactor. The current inspection process of these flaws is based on manually analyzing ultrasonic data received from multiple probes during planned, statutory outages. Recent advances on ultrasonic inspection tools enable the provision of high resolution data of significantly large volumes. This is highlighting the need for an efficient autonomous signal analysis process. Typically, the automation of ultrasonic inspection data analysis is approached by knowledge-based or supervised data-driven methods. This work proposes an unsupervised data-driven framework that requires no explicit rules, nor individually labeled signals. The framework follows a two-stage clustering procedure that utilizes the DBSCAN density-based clustering algorithm and aims to provide decision support for the assessment of potential defects in a robust and consistent way. Nevertheless, verified defect dimensions are essential in order to assess the results and train the framework for unseen defects. Initial results of the implementation are presented and discussed, with the method showing promise as a means of assessing ultrasonic inspection data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10{sup 20} n/cm{sup 2}. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Irradiation Testing of Sensors - ASI Program Review 2022

This is a powerpoint presentation for the annual Advanced Sensors and Instrumentation (ASI) program webinar. The following is a summary of the presentation. Advanced instrumentation enables testing of nuclear fuels and materials in support of the US advanced nuclear technology industry. A number of promising sensor technologies are in the pipeline. The early part of sensor development can be done outside of the reactor environment, but full technical readiness requires experience gained from in-core performance testing. Customers usually have only one shot to conduct their irradiation experiments. Because of the high costs test sponsors are frequently reluctant to incorporate unproven technologies in reactor experiments. Therefore, it is vital to demonstrate newly-developed sensors in operational conditions, prior to incorporating them into long-term high-value experiments. Successful completion of these activities will create new monitoring capabilities in high-power test reactors (such as ATR) as well as specialty reactors such as TREAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗