Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Program verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Statistical analysis of pulsed-neutron well logs in monitoring injected carbon dioxide

Pulsed-neutron well logs (PNLs) were acquired to monitor CO 2 storage associated with enhanced oil recovery. This work quantifies the precision of repeat PNLs using data from four wells and 15 repeat PNLs. Root-mean-square (RMS) precision for the repeat PNLs was less than 3%, indicating good agreement between the baseline and repeat PNLs. Evaluations of scaled relative difference (Scaled-D) showed variation in precision among individual wells and formations. Analysis of false-positive rates (FPRs) across the entire data set showed that a Scaled-D threshold in sandstone formations of approximately ±8% resulted in a 1% FPR. These Scaled-D precision thresholds were used to estimate the value of CO 2 saturation able to be confidently distinguished from baseline. The detection limit for CO 2 is lowest for high-porosity formations filled with saline water and is highest for low-porosity formations filled with fresh water. Thus, detection of vertical out-of-zone CO 2 migration using repeat PNLs is a function of instrument precision, petrophysical properties, and hydrology, all of which must be taken into account as part of the monitoring program. Here, the results of this work provide insight into how PNLs may be included within monitoring plans to detect vertical out-of-zone CO 2 migration along a wellbore or instances of wellbore failure and provide a quantitative basis for establishing detection limits of repeat PNLs to distinguish change from baseline conditions.

54 ENVIRONMENTAL SCIENCES↗

MCNP5-1.60 Release & Verification [Slides]

The latest release of the MCNP5 Monte Carlo code is designated MCNP5-1 .60. It includes enhancements to several MCNP capabilities: maximum number of cells, surfaces, materials, and tallies; isotopic reaction rates for mesh tallies; and adjoint-weighting for computing effective lifetimes and delayed neutron parameters. In addition, there are many minor code modifications to fix reported bugs, output formats, error checking, and other difficulties present with previous versions of MCNP. In nearly all cases, the bug fixes addressed problems with infrequently-used combinations of code options. In some cases, the problems that are fixed date back to the 1990s, but were only recently reported and fixed. All previously existing code capabilities are preserved, including physics options, geometry, tallying, plotting, cross-section handling, etc. No errors were found that would affect the code results for basic criticality calculations. Extensive verification and validation testing was performed, involving roughly 5,000 hrs of computing time. Tally results from MCNP5-1 .60 are expected to match the tally results of problems that can be run with the previous MCNP5-1.51, except where bugs were discovered and fixed. In this presentation, we summarize the code enhancements and provide some results from the verification/validation effort.

97 MATHEMATICS AND COMPUTING↗

Annual Site Environmental Report: 2009(ASER)

This report provides information about environmental programs during the calendar year of 2009 at the SLAC National Accelerator Laboratory (SLAC), Menlo Park, California. Activities that span the calendar year, i.e., stormwater monitoring covering the winter season of 2009/2010 (October 2009 through May 2010), are also included. Production of an annual site environmental report (ASER) is a requirement established by the United States Department of Energy (DOE) for all management and operating (M&O) contractors throughout the DOE complex. SLAC is a federally-funded research and development center with Stanford University as the M&O contractor. Under Executive Order (EO) 13423, Strengthening Federal Environmental, Energy, and Transportation Management, EO 13514, Federal Leadership in Environmental, Energy, and Economic Performance, and DOE Order 450.1A, Environmental Protection Program, SLAC effectively implements and integrates the key elements of an Environmental Management System (EMS) to achieve the site's integrated safety and environmental management system goals. For normal daily activities, SLAC managers and supervisors are responsible for ensuring that policies and procedures are understood and followed so that Worker safety and health are protected, The environment is protected, and Compliance is ensured. Throughout 2009, SLAC continued to improve its management systems. These systems provided a structured framework for SLAC to implement 'greening of the government' initiatives such as EO 13423, EO 13514, and DOE Orders 450.1A and 430.2B. Overall, management systems at SLAC are effective, supporting compliance with all relevant statutory and regulatory requirements. SLAC continues to demonstrate significant progress in implementing and integrating EMS into day-to-day operations and construction activities at SLAC. SLAC's EMS was audited by a review team from the DOE Oak Ridge Office and the DOE SLAC Site Office (SSO) on March 31, 2009. The review team found the EMS to be in substantial conformance with the appropriate EMS requirements. Based on the audit results, SLAC and DOE were able to declare conformance with DOE Order 450.1A ahead of the June 30, 2009 mandated deadline. During 2009, there were no reportable releases to the environment from SLAC operations. In addition, many improvements in waste minimization, recycling, stormwater management, groundwater restoration, and SLAC's chemical management system (CMS) were continued during the year. The following are amongst SLAC's environmental accomplishments for 2009. Hazardous materials field verifications of 36 buildings identified a number of materials that could be removed from inventory due to lack of need or age of the material. In all, 124 chemical containers were removed from inventory. SLAC's chemical purchase approval process was reconfigured to allow for more effective control over purchase of highly toxic materials. One hundred percent of SLAC's purchased desktops, laptops, and monitors were either Silver or Gold level Electronic Product Environmental Assessment Tool (EPEAT) certified in fiscal year (FY) 2009. SLAC continues to make progress on achieving the sustainability goals of EOs 13423 and 13514, which include, but are not limited to reductions in the use of water, energy, and fuel, building to green standards and reductions in greenhouse gas (GHG) emissions. In 2009, no radiological incidents occurred that increased radiation levels or released radioactivity to the environment. In addition to managing its radioactive wastes safely and responsibly, SLAC worked to reduce the amount of waste generated. During calendar year (CY) 2009, SLAC shipped 1324 cubic feet of low-level radioactive waste, legacy waste accounted for 40 percent of the volume, to appropriate treatment and disposal facilities for low-level radioactive waste. Moreover, SLAC continued its efforts in the inventory reduction of materials no longer needed for its mission: returned 28 sealed sources to the manufacturer, transferred additional 3 sources to Los Alamos National Laboratory, and disposed of 636 kilograms of depleted uranium tiles. In 2009, the SLAC Environmental Restoration Program personnel continued work on site characterization and evaluation of remedial alternatives at four sites with volatile organic compounds in groundwater and several areas with polychlorinated biphenyls and low concentrations of lead in soil. SLAC is regulated under a site cleanup requirements order (board order) issued by the California Regional Water Quality Control Board (RWQCB), San Francisco Bay Region on October 19, 2009, for the investigation and remediation of impacted soil and groundwater at SLAC. Risk-based preliminary cleanup goals for impacted soil and groundwater have been established for SLAC, and the remedial efforts are being designed to meet these established goals.

Source record↗

Safety software release options to support plant start-up and commissioning activities - 285

The schedule demands on new nuclear power plant site testing and commissioning programs challenge the plant's Instrumentation and Control (I and C) supplier's ability to provide certified safety software releases to meet the needs of these programs. This paper outlines the typical certified safety software development and certification process which follows a Waterfall software life-cycle model. The conflicts that result between supporting the site program and the safety software supplier's internal certification program are identified. An adapted 'functional' safety release process is presented that supports the site program's needs for software changes and in parallel enables the safety software certification process to proceed. Comparisons between the two safety software release processes are examined and the benefits realized through the use of the adapted 'functional' safety software release process are discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reducing PV Performance Uncertainty by Accurately Quantifying the PV Resource

Reducing uncertainty in the prediction and/or verification of photovoltaic (PV) plant output can directly increase the expected return on investment for each party in a contract, likely leading to more favorable terms for the contract, including a possible reduction in interest rates. Note that a reduction of 1% in the interest rate is estimated to reduce the levelized cost of energy by approximately 0.5 cents/kWh. This project developed a capability to provide spectrally resolved solar information from the National Solar Radiation Data Base (NSRDB), effectively providing 20 years of half-hourly data for all of the United States at a 4-km by 4-km spatial resolution. These data are now available freely to users directly through a geographic information system-based Web interface (https://nsrdb.nrel.gov) as well as through an application programming interface. Users of these data can conduct more accurate prefeasibility studies and assess multiple PV technologies. It is expected that widely used models such as PVSyst, the National Renewable Energy Laboratory's System Advisor Model (SAM), and PlantPredict, designed by First Solar, will develop the capabilities to use these spectral data.

14 SOLAR ENERGY↗

A Study of B→c$\bar{c}$γK in the BaBar Experiment

The BABAR Collaboration is a high energy physics experiment located at the Stanford Linear Accelerator Center. The primary goal of the experiment is to study charge and parity violation in the B-meson sector, however the copious production of B mesons decaying to other final states allows for a wide-ranging physics program. In particular, one can access the charmonium system via colour-suppressed b → c decays of the type B → c$\bar{c}$K. This thesis presents a study of B →c$\bar{c}$γK decays where c$\bar{c}$ includes J/Ψ and Ψ(2S), and K includes K ± , K S 0 and K*(892). The particular emphasis is on a search for the radiative decays X(3872) → J/Ψγ and X(3872) → Ψ(2S)γ. The X(3872) state is a recently-discovered resonance of undetermined quark composition, speculatively a conventional charmonium state or exotic four-quark di-meson molecule. This research is also sensitive to the well-known radiative charmonium decays B → χ c1,2 K, which are used as verification for the analysis technique. This dissertation sets the best B → χ c1 K branching fraction measurements to date, and sees the first evidence for factorization-suppressed B 0 → χ c2 }K* 0 decay at a level of 3.6σ. It also provides evidence for X(3872) → J/Ψγ and X(3872) → Ψ(2S)γ with 3.6σ and 3.3σ significance, respectively. The product of branching fractions β(B ± → X(3872)K ± ) • β(X(3872) → J/Ψγ) = (2.8 ± 0.8(stat.) ± 0.2(syst.)) x 10{sup -6} and β(B{ ± → X(3872)K ± ) → β(X(3872) → Ψ(2S)γ) = (9.5 ± 2.7(stat.) ± 0.9(syst.)) x 10 - 6 are measured. These results improve upon previous X(3872) → J/Ψγ measurements, and represent the first evidence for X(3872) → Ψ(2S)γ.

43 PARTICLE ACCELERATORS↗

Support for Fuel Fabrication and Characterization

Oak Ridge National Laboratory (ORNL) has participated in the Advanced Gas Reactor (AGR) program for the Next Generation Nuclear Plant (NGNP) and the transition to the Idaho National Laboratory (INL) Advanced Reactor Technologies (ART) Technology Development Office (TDO) since the inception of the program. In this effort, ORNL has fabricated tristructural isotropic (TRISO) fuel and fuel compacts for AGR-1, AGR-2, and AGR-3/4 experiments, provided matrix only components for AGC-2, AGC-4, and AGR 3/4 experiments and for university studies, and provided characterization, coating, and compaction support for INL and BWX Technologies Nuclear Operations Group (BWXT). In fiscal year (FY) 2017, the activities for the INL ART TDO fuel development are focused on preparations for the AGR-5/6/7 experiments and technical support to the Generation IV (GenIV) pre-irradiation leach-burn-leach round robin effort with China and South Korea. With the successful transfer of fuel fabrication technology to BWXT, ORNL’s involvement has shifted toward transferring fuel characterization methods, providing technical support, verification of BWXT laboratory results, and fabricating surrogate fuel materials for university collaborations. ORNL will also provide analytical support to BWXT and INL for uranium dispersion analysis and confirmatory fuel characterization analyses as needed.

Modeling The DLOFC Accident Scenario of HTR-PM Equilibrium Core Using NEAMS Tools

High-Temperature Gas-cooled Reactors (HTGRs) have excellent characteristics in terms of safety and high thermal efficiency, and they are gaining a large interest from the industry as a candidate of Gen-IV reactors for a wide range of applications. The High Temperature gas-cooled Reactor Pebble-bed Module project (HTR-PM) is one of these designs and where helium gas is used to cool the pebble-bed region that consists of spherical fuel elements moderated with graphite. The HTR-PM design is based on the combined experience from the German pebble-bed reactor program from the 1960s through the 1990s and the HTR-10 experience in China during the 2000s. Idaho National Laboratory has a long experience in modeling of HTGRs working in developing neutronics and thermal hydraulics tools for the proper modeling of these reactors. The neutronics code Griffin has the capability to model pebble depletion . While the thermal hydraulics code Pronghorn was developed mainly to model the pebble bed reactors with the porous media assumption. In this work, an equilibrium core Multiphysics model was developed for the HTR-PM reactor to analyze the depressurized loss of forced cooling accident scenario (DLOFC). This paper is organized as follows: First, a brief description of the reactor and model specifications are provided. Then, the developed Multiphysics model is discussed. Finally, verification results of the steady-state equilibrium core and DLOFC accident are presented followed by a summary of the conclusions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Revised and Upcoming Nuclear Data Sensitivity MCNP Features [Poster]

Nuclear data is ubiquitous across nuclear applications. Improved nuclear data means more accurate simulations. Past focus on k eff caused compensating error and areas of unvalidated nuclear data. Sensitivity can be used to optimize experiments to focus on specific areas. Sensitivity capabilities must be expanded and improved to design multivariate experiments focused on nuclear data needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-CAMPUS-T-06: Initial Experience of Patient-Specific QA Using a Pencil Beam Scanning Proton Therapy System

Purpose: To illustrate patient QA results for the first 10 patients treated at Scripps Proton Center by comparing point dose measurement using an ion chamber and in-house developed secondary MU program, and the measurement of 2D dose distribution using an ion chamber array. Methods: At the time of writing, 10 patient plans were approved for treatment using Varian ProBeam pencil beam scanning system and Eclipse treatment planning software. We used the IBA CC04 0.04 cm3 ion chamber and PTW Unidos E electrometer for point dose measurement in a small water tank (Sun Nuclear 1D scanner). We developed independent MU check software based on measured pencil beam dose profiles for various energies. We used PTW Octavius 729 XDR array to evaluate 2D planar dose distribution. The 3D gamma at 3%/3 mm local dose was used to compare a 3D calculated dose plan with a 2D measured dose distribution using PTW Verisoft software. All fields were exported to a verification phantom plan and delivered at 0 degrees for simplicity. Results: Comparisons between the CC04 ion chamber measurement and calculated dose agree well within 1%. The PTW Octavius 729 XDR array exhibited some dose rate dependence in high dose rate pencil beam delivery. Nevertheless, the results, used as a relative measurement, passed the gamma criteria of 3%/3mm for greater than 90% of area in all patient fields. Visual inspection showed good agreement between ion chamber dose profile and the calculated plan. The in-house secondary check for MU agreed very well with the plan dose and measurement. The results will be updated with more patients treated. Conclusion: The initial patient specific QA results are encouraging for a new pencil beam scanning only proton therapy system.

60 APPLIED LIFE SCIENCES↗

Lights, Camera, Action ... and Cooling - The case for centralized low carbon energy at Fox Studios

Fox Studios partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit two production stages and one of its central cooling plants, to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program. Although this case study reports expected savings arising from proposed design recommendations for a unique building type and the unusual load characteristics associated with its use, the EEMs implemented for the central plant are applicable to any large campus, office and higher education facility. The intent is that by making the energy-efficiency measures (EEMs) set that were assessed as cost-effective from this project applicable to a larger number of buildings on the campus Fox Studios will be able to implement an integrated campus-wide energy strategy for the long term. The significant challenges for this project in the design phase included identifying how to assess and analyze multiple system types, develop a coherent strategy for assessment and analysis, implement the measurement and verification activities to collect the appropriate data (in terms of capturing ‘normal’ operating characteristics and granularity) and determine the best approach to providing cooling to the site buildings based on the nature of existing systems and the expected improvement in energy performance of the central cooling plant. The analytical framework adopted provides a blueprint for similar projects at other large commercial building campuses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaborative: Fusion Simulation Program

New York University, Courant Institute of Mathematical Sciences, participated in the Fusion Simulation Program (FSP) Planning Activities [http://www.pppl.gov/fsp], with C.S. Chang as the institutional PI. FSP's mission was to enable scientific discovery of important new plasma phenomena with associated understanding that emerges only upon integration. This requires developing a predictive integrated simulation capability for magnetically-confined fusion plasmas that are properly validated against experiments in regimes relevant for producing practical fusion energy. Specific institutional goal of the New York University was to participate in the planning of the edge integrated simulation, with emphasis on the usage of large scale HPCs, in connection with the SciDAC CPES project which the PI was leading. New York University successfully completed its mission by participating in the various planning activities, including the edge physics integration, the edge science drivers, and the mathematical verification. The activity resulted in the combined report that can be found in http://www.pppl.gov/fsp/Overview.html. Participation and presentations as part of this project are listed in a separation file.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cyber-Resilient Distributed Autonomous Energy Grid

The DARPA Assured Micropatching (AMP) program focuses on creating the capability for rapid patching of legacy binaries in mission critical systems leveraging the field of formal methods. NREL's Cyber Resilient TLDRD effort, focuses on leveraging the field of formal methods to develop tools and methods for formally verifiable implementations of security architectures such as Zero Trust Architecture. The presentation at the DARPA AMP PI meeting is primarily inspired by common interests and ongoing work on leveraging Formal Methods for OT cybersecurity.

cybersecurity↗

Analysis Capability and Data Needs Identified During the Evaluation of the SILENE CAAS Benchmarks

In October 2010, a series of benchmark experiments was conducted at the Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA to create three benchmarks for verification and validation of radiation transport codes, as well as evaluated nuclear data, used to analyze criticality accident alarm systems (CAASs). Many preliminary details of these experiments and their evaluation have been discussed in previous publications. The first benchmark evaluation was published in 2015, and the second and third evaluations will be published at the end of 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-563: A Fast and Quantative Picket-Fence Test of a Submillimeter Patient Positioning System for Stereotactic Radiosurgery

Purpose: Picket-fence test is a qualitative TG142-recommended quality assurance (QA) test for multileaf collimators. In study, we adopted the same concept and developed a fast but quantatitive QA test for an automatic patient positioning system that requires submilleter accuracy for a radiosurgical treatment. Methods: A piece of radiochromic film was first placed inside a spherical solid water phantom and then irradiated with a sequenence of linearly placed shots of same collimator size (e.g. 4-mm) via the Leskell Gamma Knife Perfexion system (PFX). The shots were positioned with either equal or non-equal gaps of approximately 4 mm to 8 mm depending on the location of the region of interest. A pattern recognization program was developed and then applied to measure the gap spacing between two adjacent shots. The measured distance was then compared with the initial preset values for the test. Results: By introducing variable systematic and random shifts of 0.1 mm to 0.5 mm to the shot sequence, the maximum gap variation from the described test was found to be 0.35 mm or less. On average the positioning uncertainty for the PFX delivery system was found to be 0.1±0.2 mm. No significant difference in the positioning uncertainty was noted for the centrally aligned shot sequence locations versus the peripherally aligned shot sequence locations. Conclusion: A new quantitative picket-fence type test was developed and demonstrated for routine QA of the submillimeter PFX patient positioning sytem. This test also enables independent verification of any patient-specific shot positioning for a critical treatment such as a tumor in brainstem. Dr Ma is currently on the board of international society of stereotactic Radiosurgery.

60 APPLIED LIFE SCIENCES↗

Support for Fuel Fabrication and Characterization

Oak Ridge National Laboratory (ORNL) has participated in the Advanced Gas Reactor (AGR) program for the Next Generation Nuclear Plant (NGNP) and the transition to the Idaho National Laboratory (INL) Advanced Reactor Technologies (ART) Technology Development Office (TDO) since the inception of the program. In this effort, ORNL has fabricated tristructural isotropic (TRISO) fuel and fuel compacts for AGR-1, AGR-2, and AGR-3/4 experiments, provided matrix only components for AGC-2, AGC-4, and AGR 3/4 experiments and for university studies, and provided characterization, coating, and compaction support for INL and BWX Technologies Nuclear Operations Group (BWXT). In fiscal year (FY) 2017, the activities for the INL ART TDO fuel development are focused on preparations for the AGR-5/6/7 experiments and technical support to the Generation-IV International Forum (GIF) pre-irradiation leach-burn-leach (LBL) round robin effort with China and South Korea. With the successful transfer of fuel fabrication technology to BWXT, ORNL’s involvement has shifted toward transferring fuel characterization methods, providing technical support, verification of BWXT laboratory results, and fabricating surrogate fuel materials for university collaborations. ORNL will also provide analytical support to BWXT and INL for uranium dispersion analysis and confirmatory fuel characterization analyses as needed.

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MO-F-CAMPUS-T-05: Design of An Innovative Beam Monitor for Particle Therapy for the Simultaneous Measurement of Beam Fluence and Energy

Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energy and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.

61 RADIATION PROTECTION AND DOSIMETRY↗