Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Self-healing liquid/solid state battery

A battery system that exchanges energy with an external device is provided. The battery system includes a positive electrode having a first metal or alloy, a negative electrode having a second metal or alloy, and an electrolyte including a salt of the second metal or alloy. The positive electrode, the negative electrode, and the electrolyte are in a liquid phase at an operating temperature during at least one portion of operation. The positive electrode is entirely in a liquid phase in one charged state and includes a solid phase in another charged state. The solid phase of the positive electrode includes a solid intermetallic formed by the first and the second metals or alloys. Methods of storing electrical energy from an external circuit using such a battery system are also provided.

25 ENERGY STORAGE↗

Solitary waves in a self-gravitating opposite polarity dust-plasma medium

A more general and realistic dusty plasma model, namely, self-gravitating opposite polarity dust-plasma system (containing inertial positive and negative dust, and inertialess ions and electrons following Maxwellian distribution) is considered. The possibility for the formation of solitary electrostatic and self-gravitational potential structures in such a dust-plasma system is thoroughly examined. The standard reductive perturbation method, which is valid for small but finite amplitude solitary structures, is employed. The parametric regimes for the existence of solitary electrostatic and self-gravitational potential structures, and their basic properties (viz., polarity, amplitude, width, and speed) are found to be significantly modified by the combined effects of positively charged dust component and self-gravitational field. The applications of the present investigation in different space dusty plasma environments and laboratory dusty plasma devices are briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pendulum Systems with Dynamical Symmetry

In this paper, we consider a class of oscillatory mechanical systems described by nonlinear second-order differential equations that contain parameters with variable dissipation and possess the property of dynamic symmetry. We study properties of mathematical models of such systems depending on parameters. Special attention is paid to bifurcations and reconstructions of phase portraits and the appearance and disappearance of cycles that envelope the phase cylinder or lie entirely on its covering. We present a complete parametric analysis of system with position-viscous friction and four parameters, where the force action linearly depends on the speed. The space of parameters is split into domains in which the topological behavior of the system is preserved. For some classes of pendulum systems whose right-hand sides depend on smooth functions, a qualitative analysis is performed, i.e., the space of systems considered is split into domains of different behavior of trajectories on the phase cylinder of quasi-velocities. We also perform a systematic analysis of the problem on an aerodynamic pendulum and detect periodic modes unknown earlier; these modes correspond to cycles in the mathematical model.

97 MATHEMATICS AND COMPUTING↗

navgps (a1)

On sea-based mobile ARM deployments, several instruments depend on the ship’s current position and "attitude". The NAV system reads the ship’s current position (latitude and longitude) as well as its "attitude" (roll, pitch, and yaw angles). This data is collected for both near-real-time and post-deployment processing of instrument data.

54 ENVIRONMENTAL SCIENCES↗

nav (a1)

On sea-based mobile ARM deployments, several instruments depend on the ship’s current position and "attitude". The NAV system reads the ship’s current position (latitude and longitude) as well as its "attitude" (roll, pitch, and yaw angles). This data is collected for both near-real-time and post-deployment processing of instrument data.

54 ENVIRONMENTAL SCIENCES↗

Global irrigation demand - A holistic approach

To develop a research track on global irrigation demand and the use of future water resources to help feed the world, we need to adopt a holistic approach to understand inter-dependencies and the main drivers of the global water system and unravel positive (reinforcing) and negative (balancing) feedback loops that can lead to cascading consequences. Thus, there needs to be more research dedicated to 1) the modeling of the agricultural and water systems as components within an integrated assessment human-Earth modeling framework, 2) the understanding of the linkages between the physical processes and the human system, and to integrate them in an economic framework to capture the dynamics of market price, and institutional regulations. This editorial discusses the importance of tackling the global irrigation problem in an integrated assessment modeling framework.

irrigation, global, integrated assessment modeling↗

Implementation and experimental results of 4D tumor tracking using robotic couch

Purpose: This study presents the implementation and experimental results of a novel technique for 4D tumor tracking using a commercially available and commonly used treatment couch and evaluates the tumor tracking accuracy in clinical settings. Methods: Commercially available couch is capable of positioning the patient accurately; however, currently there is no provision for compensating physiological movement using the treatment couch in real-time. In this paper, a real-time couch tracking control technique is presented together with experimental results in tumor motion compensation in four dimensions (superior-inferior, lateral, anterior-posterior, and time). To implement real-time couch motion for tracking, a novel control system for the treatment couch was developed. The primary functional requirements for this novel technique were: (a) the treatment couch should maintain all previous/normal features for patient setup and positioning, (b) the new control system should be used as a parallel system when tumor tracking would be deployed, and (c) tracking could be performed in a single direction and/or concurrently in all three directions of the couch motion (longitudinal, lateral, and vertical). To the authors' best knowledge, the implementation of such technique to a regular treatment couch for tumor tracking has not been reported so far. To evaluate the performance of the tracking couch, we investigated the mechanical characteristics of the system such as system positioning resolution, repeatability, accuracy, and tracking performance. Performance of the tracking system was evaluated using dosimetric test as an endpoint. To investigate the accuracy of real-time tracking in the clinical setting, the existing clinical treatment couch was replaced with our experimental couch and the linear accelerator was used to deliver 3D conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment plans with and without tracking. The results of radiation dose distribution from these two sets of experiments were compared and presented here. Results: The mechanical accuracies were 0.12, 0.14, and 0.18 mm in X, Y, and Z directions. The repeatability of the desired motion was within {+-}0.2 mm. The differences of central axis dose between the 3D-CRT stationary plan and two tracking plans with different motion trajectories were 0.21% and 1.19%. The absolute dose differences of both 3D tracking plans comparing to the stationary plan were 1.09% and 1.20%. Comparing the stationary IMRT plan with the tracking IMRT plan, it was observed that the central axis dose difference was -0.87% and the absolute difference of both IMRT plans was 0.55%. Conclusions: The experimental results revealed that the treatment couch could be successfully used for real-time tumor tracking with a high level of accuracy. It was demonstrated that 4D tumor tracking was feasible using existing couch with implementation of appropriate tracking methodology and with modifications in the control system.

60 APPLIED LIFE SCIENCES↗

Large magnetocapacitance in electronic ferroelectric manganite systems

We have observed a sizable positive magnetocapacitance (∼5%–90%) in perovskite Pr{sub 0.55}Ca{sub 0.45}MnO{sub 3} and bilayer Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} system under 5 T magnetic field across 20–100 K below the magnetic transition point T{sub N}. The magnetodielectric effect, on the other hand, exhibits a crossover: (a) from positive to negative for the perovskite system and (b) from negative to positive for the bilayer system over the same temperature range. The bilayer Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} system exhibits a sizable anisotropy as well. We have also noticed the influence of magnetic field on the dielectric relaxation characteristics of these systems. These systems belong to a class of improper ferroelectrics and are expected to exhibit charge/orbital order driven ferroelectric polarization below the transition point T{sub CO}. Large magnetocapacitance in these systems shows a typical multiferroic behavior even though the ferroelectric polarization is small in comparison to that of other ferroelectrics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hadron Monitor Calibration System for NuMI

NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.

43 PARTICLE ACCELERATORS↗

Highly Effective Steel Cable Solar PV Mounting System (Final Technical Report)

Motivation: The motivation for the project was for to be able to fund sufficient research to develop, engineer, and prove a market for a P4P cable-based parking structure. The goal was for the product to be less expensive, built more easily and quickly, and have a reduced energy/carbon footprint than the competition in the solar over parking market. Importance: There has been tremendous innovation in almost all aspects of the solar industry. Reduction in component costs and the ease of construction in the racking market have been less substantial. P4P's reduction of the amount of steel required to build a solar racking structure means that the P4P Energy system goes energy positive more quickly and has a reduced carbon footprint than conventional structures. Goals: Many of the goals are in the motivation section above. The overarching goal was to have a productized system have a place and is ready to be sold in the market.

14 SOLAR ENERGY↗

Towards a deep characterization of a 64-fold-pixelated position sensitive detector for a new {gamma}-scanning system of HPGe segmented detectors

Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform {gamma}-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association with the highest precision. In this laboratory, a new scanning system, SALSA (Salamanca Lyso-based Scanning Array), consisting on a high spatial resolution {gamma} camera, is a under development. In this work the whole scanning system is presented and first results for the characterization of the {gamma} camera are shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging

Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck intermediate results. XII: Diffuse Galactic components in the Gould Belt system

We perform here an analysis of the diffuse low-frequency Galactic components in the southern part of the Gould Belt system (130° ≤ l ≤ 230° and -50° ≤ b ≤ -10°). Strong ultra-violet flux coming from the Gould Belt super-association is responsible for bright diffuse foregrounds that we observe from our position inside the system and that can help us improve our knowledge of the Galactic emission. Free-free emission and anomalous microwave emission (AME) are the dominant components at low frequencies (ν < 40 GHz), while synchrotron emission is very smooth and faint. We separated diffuse free-free emission and AME from synchrotron emission and thermal dust emission by using Planck data, complemented by ancillary data, using the correlated component analysis (CCA) component-separation method and we compared our results with the results of cross-correlation of foreground templates with the frequency maps. We estimated the electron temperature T e from Hα and free-free emission using two methods (temperature-temperature plot and cross-correlation) and obtained T e ranging from 3100 to 5200K for an effective fraction of absorbing dust along the line of sight of 30% (f d = 0.3). We estimated the frequency spectrum of the diffuse AME and recovered a peak frequency (in flux density units) of 25.5 ± 1.5 GHz. We verified the reliability of this result with realistic simulations that include biases in the spectral model for the AME and in the free-free template. By combining physical models for vibrational and rotational dust emission and adding the constraints from the thermal dust spectrum from Planck and IRAS, we are able to present a good description of the AME frequency spectrum for plausible values of the local density and radiation field.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RY AQUARIUS A BINARY SYSTEM WITH PULSATING δ-SCUTI PRIMARY COMPONENT

We present simultaneous new BVI light curves along with radial velocity curve analysis of the RY Aqr system, using the PHysics Of Eclipsing BinariEs code. The analysis indicates that while the primary is completely inside its Roche critical surface, the secondary has filled out its Roche surface. In addition, the positions of the system components on M–R, H–R diagrams are specified, which show that the primary is a main-sequence or nearly main-sequence star while the secondary is an evolved subgiant. In addition, analysis of the period and luminosity variations of the system were carried out. Fourier frequency analysis of light variation indicates that the primary is a pulsating, δ-scuti variable star. Moreover, O–C curve analysis shows that the period of the system is secularly decreasing with a rate of dp/dt = 0.074 s yr{sup −1}. This decrease in the orbital period variations was attributed to a mass and angular momentum loss from the system with a rate of 2.57×10{sup −10}M{sub ⊙} yr{sup −1}. Apart from the secular period decreases, the orbital period of the system is modulated by a cyclic period of 72.69 year, which was attributed to a third body orbiting around the barycenter of the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom

Purpose: A novel 4D in vivo dosimetry system (RADPOS), in conjunction with a deformable lung phantom, has been evaluated as a potential quality assurance tool for 4D radiotherapy. Methods: RADPOS detectors, which consist of a MOSFET dosimeter combined with an electromagnetic positioning probe, were placed inside the deformable lung phantom. One detector was positioned directly inside a tumor embedded in the lung phantom and another was positioned inside the lung portion of the phantom, outside the tumor. CT scans were taken with the phantom at three breathing phases, and for each phase, the detector position inside the phantom was read with the RADPOS software and compared to the position as determined from the CT data. These values were also compared to RADPOS measurements taken with the phantom on the couch of a Varian Clinac 6EX linac. The deformable phantom and the RADPOS system were also used in two radiation delivery scenarios: (1) A simulation of a free-breathing delivery and (2) a simulation of an adaptive treatment. Results: Compared to CT imaging, the RADPOS positional accuracy was found to be better than 2.5 mm. The radial displacement measurements taken in the CT and linac rooms agreed to within an average of (0.7{+-}0.3) mm. Hence, the system can provide relative displacement measurements in the treatment room, consistent with measurements made in the CT room. For the free-breathing delivery, the total dose reported by RADPOS agreed to within 4% and 5% of the treatment planning doses in the tumor and the lung portion of the phantom, respectively. The RADPOS-measured dose values for the adaptive delivery were within 1.5% of the treatment plan values, which was well within the estimated experimental uncertainties. Conclusions: This work has shown that the deformable lung phantom-RADPOS system can be an efficient quality assurance tool for 4D radiation therapy.

60 APPLIED LIFE SCIENCES↗

Upscaling of Mixed Finite Element Discretization Problems by the Spectral AMGe Method

Here, we propose two multilevel spectral techniques for constructing coarse discretization spaces for saddle-point problems corresponding to PDEs involving a divergence constraint, with a focus on mixed finite element discretizations of scalar self-adjoint second order elliptic equations on general unstructured grids. We use element agglomeration algebraic multigrid (AMGe), which employs coarse elements that can have nonstandard shape since they are agglomerates of fine-grid elements. The coarse basis associated with each agglomerated coarse element is constructed by solving local eigenvalue problems and local mixed finite element problems. This construction leads to stable upscaled coarse spaces and guarantees the inf-sup compatibility of the upscaled discretization. Also, the approximation properties of these upscaled spaces improve by adding more local eigenfunctions to the coarse spaces. The higher accuracy comes at the cost of additional computational effort, as the sparsity of the resulting upscaled coarse discretization (referred to as operator complexity) deteriorates when we introduce additional functions in the coarse space. We also provide an efficient solver for the coarse (upscaled) saddle-point system by employing hybridization, which leads to a symmetric positive definite (s.p.d.) reduced system for the Lagrange multipliers, and to solve the latter s.p.d. system, we use our previously developed spectral AMGe solver. Numerical experiments, in both two and three dimensions, are provided to illustrate the efficiency of the proposed upscaling technique.

97 MATHEMATICS AND COMPUTING↗