Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Topology-Dependent Performance of Free-Space Photonic Quantum Networks Under Noise

Photonic quantum communication enables secure and high-fidelity information transfer beyond classical limits, with direct relevance to emerging quantum networks operating in free-space environments. While physical-layer models of depolarizing noise, Gamma–Gamma turbulence statistics, entanglement swapping, and decoy-state QKD security bounds are individually well established, prior work typically treats these components in isolation or under fixed network assumptions. In this work, we develop a unified topology-aware analytical framework that simultaneously integrates free-space optical link budgets, turbulence-induced visibility degradation, depolarizing qubit noise, multi-hop entanglement cascade dynamics, teleportation fidelity thresholds, CHSH nonlocality certification, and asymptotic decoy-state secret key rate bounds across star, mesh, and ring graph structures. Rather than introducing new physical channel models, we demonstrate that identical physical links exhibit fundamentally different end-to-end performance once embedded within different network topologies. Mesh architectures minimize visibility cascade through hop-count reduction but incur quadratic hardware scaling. Star topologies minimize link count but concentrate noise and synchronization overhead at the hub. Ring configurations offer linear hardware scaling with multiplicative fidelity degradation. The results establish topology as a first-order design parameter in near-term free-space quantum networks operating without full quantum repeater infrastructures. While motivated by distributed multi-agent architectures, the framework applies broadly to terrestrial, airborne, and satellite-assisted photonic quantum communication systems.

QKD↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of short-lived fission product yields from photofission of 238 U using 13.0 MeV monoenergetic photons

Photon-induced fission product yield (FPY) measurements were conducted on the isotope 238U. Fission was induced using Eγ = 13.0 MeV monoenergetic photons produced by the Triangle Universities Nuclear Laboratory’s (TUNL’s) High Intensity γ-ray Source (HIγS) facility. Short-lived FPYs were measured by performing cyclic activation of the sample using a rapid target transfer system. Following activation, the 238U target was rapidly (0.4 s) transferred to a counting station consisting of two well-shielded high-purity germanium (HPGe) detectors. The irradiation-counting cycle was repeated until the summed data had sufficient statistical accuracy. Twenty-eight unique fission products with half-lives ranging from 1 s to 450 s were identified, and their cumulative FPYs determined. Furthermore, the results are compared with previous independent FPY measurements using inverse kinematics. Good agreement between the data sets is found despite the different excitation energy distributions of the fissioning nucleus in the experiments.

Physics - Nuclear physics and radiation physics↗

Reconstructing the Gamma-Ray Photon Optical Depth of the Universe To Z Approx. 4 from Multiwavelength Galaxy Survey Data

Reconstructing the Gamma-Ray Photon Optical Depth of the Universe To Z Approx. 4fFrom Multiwavelength Galaxy Survey Data We reconstruct the gamma-ray opacity of the universe out to z approx. < 3–4 using an extensive library of 342 observed galaxy luminosity function (LF) surveys extending to high redshifts .We cover the whole range from UV to mid-IR (0.15–25 micron ) providing for the first time a robust empirical calculation of the gamma gamma optical depth out to several TeV. Here, we use the same database as Helgason et al. where the extragalactic background light was reconstructed from LFs out to 4.5 micron and was shown to recover observed galaxy counts to high accuracy. We extend our earlier library Of LFs to 25micron such that it covers the energy range of pair production with gamma -rays (1) in the entire Fermi/LAT energy range, and (2) at higher TeV energies probed by ground-based Cherenkov telescopes. In the absence of significant contributions to the cosmic diffuse background from unknown populations, such as the putative Population III era sources, the universe appears to be largely transparent to gamma-rays at all Fermi/LAT energies out to z approx.. 2 whereas it becomes opaque to TeV photons already at z approx. < 0.2 and reaching tau approx∼ 10 at z = 1. Comparing with the currently available Fermi/LAT gamma-ray burst and blazar data shows that there is room for significant emissions originating in the first stars era.

galaxies:evolution↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reionization and the cosmic microwave background in an open universe

If the universe was reionized at high reshift (z greater than or approximately equal to 30) or never recombined, then photon-electron scattering can erase fluctuations in the cosmic microwave background at scales less than or approximately equal to 1 deg. Peculiar motion at the surface of last scattering will then have given rise to new anisotropy at the 1 min level through the Vishniac effect. Here the observed fluctuations in galaxy counts are extrapolated to high redshifts using linear theory, and the expected anisotropy is computed. The predicted level of anisotropies is a function of Omega(sub 0) and the ratio of the density in ionized baryons to the critical density and is shown to depend strongly on the large- and small-scale power. It is not possible to make general statements about the viability of all reionized models based on current observations, but it is possible to rule out specific models for structure formation, particularly those with high baryonic content or small-scale power. The induced fluctuations are shown to scale with cosmological parameters and optical depth.

Persi, Fred M.↗

Accelerating quantum optics experiments with statistical learning

Quantum optics experiments, involving the measurement of low-probability photon events, are known to be extremely time-consuming. We present a methodology for accelerating such experiments using physically motivated ansatzes together with simple statistical learning techniques such as Bayesian maximum a posteriori estimation based on few-shot data. We show that it is possible to reconstruct time-dependent data using a small number of detected photons, allowing for fast estimates in under a minute and providing a one-to-two order of magnitude speed-up in data acquisition time. We test our approach using real experimental data to retrieve the second order intensity correlation function, G (2) ($τ$), as a function of time delay τ between detector counts, for thermal light as well as anti-bunched light emitted by a quantum dot driven by periodic laser pulses. The proposed methodology has a wide range of applicability and has the potential to impact the scientific discovery process across a multitude of domains.

36 MATERIALS SCIENCE↗

Angular Correlations of Gamma Rays from Fission Product Solution

Fission products from photon-induced fission are routinely used at Idaho National Laboratory as part of nuclear forensics activities. Typically, the focus is on fission products with relatively large fission yields (Ba-140, Mo-99, etc.). The nuclear data associated with the well-known isotopes have small uncertainties, and many have well-known angular correlations between emitted gamma-rays, if applicable. However, for isotopes with smaller fission yields or less intense gamma-ray emission intensities, the nuclear decay schemes and gamma-ray emission intensities may be less well-known. The Germanium Rotational Measurements for Angular Correlation (GeRMAC) system was designed to use two high-purity germanium (HPGe) detectors in a coincidence counting set-up but allows one of the HPGe detectors to rotate at a constant distance from a radioactive source, changing the relative angle between the two HPGe detectors. Angular correlations can then be determined from the relative photopeak areas between two gamma-rays emitted as part of the same nuclear decay. By recording the HPGe spectra in list mode, the angular correlations of gamma-rays emitted from complex sources, consisting of multiple isotopes, can be measured simultaneously and the individual isotope emissions can be isolated. Using the GeRMAC system, a multi-isotope fission product source, produced with photon-induced fission of U-238, was measured using a single rotational arc (180 degrees) to obtain the angular correlation between gamma-rays emitted by the large number of fission products contained in the solution with an angular accuracy of 1 degree. In particular, La-140 (38 gamma rays) and Nd-147 (26 gamma rays) are of interest to the nuclear forensics community.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

BATSE spectroscopy catalog of bright gamma-ray bursts

This paper presents comprehensive results on the spectra of 30 bright gamma ray bursts (GRBs) as observed by the Spectroscopy Detectors (SDs) of the Burst And Transient Source Experiment (BATSE). The data selection was strict in including only spectra that are of high reliability for continuum shape studies. This BATSE Spectroscopy Catalog presents fluences, model fits (for five spectral models for three energy ranges), and photon spectra in a standard manner for each burst. Complete information is provided to describe the data selection and analysis procedures. The catalog results are also presented in electronic format (from the Compton Observatory Science Support Center) and CD-ROM format (AAS CD-ROM series, Vol. 2). These electronic formats also present the count spectra and detector response matrices so as to allow for independent study and fitting by researchers outside the BATSE Team. This BATSE Spectroscopy Catalog complements the catalog from BATSE Large Area Detector (LAD) data by Fishman et al. (1994).

Schaefer, Bradley E.↗

Quantum-enhanced phase imaging without coincidence counting

Quantitative phase imaging provides a way to image transparent objects, such as biological cells, and measure their thickness. We report on a phase-imaging method that achieves twice the phase shift and approximately 1.7 times the spatial resolution of an equivalent spatially and temporally coherent classical quantitative phase-imaging system by using quantum interference between successive spontaneous parametric downconversion events in a nonlinear crystal. Furthermore, our method is approximately 1000 times faster than imaging the parametric downconversion photons in coincidence, which requires measurement times on the order of tens of hours. Our method may be useful for imaging sensitive transparent objects that require low illumination intensities at near-infrared and longer illumination wavelengths, such as photosensitive biological samples.

47 OTHER INSTRUMENTATION↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The production of NH(A 3Pi i) through photodissociative excitation of NH3

The NH(A-X) emission produced by photodissociation of NH3 is examined using a line emission source in the 600-1340 A region. It is observed that the production of the NH(A 3Pi i) photofragment involves a spin-forbidden transition. Fluorescence spectra of NH3 are derived and analyzed. The relationship between fluorescence cross sections and fluorescence count rates and gas pressure is studied. The fluorescence cross sections of NH(A-X) are calculated as 2.1 x 10 to the -22nd, 3.1 x 10 to the -22nd, 3.0 x 10 to the -21st, 1.5 x 10 to the -20th, and 3.4 x 10 to the -20th sq cm for the primary photon wavelength of 1239, 1184, 1065, 1037, and 976 A, respectively; and the corresponding fluorescence quantum yields are 0.00002, 0.00003, 0.0012, 0.0085, and 0.015.

Wu, C. Y. Robert↗

Discrimination of shot-noise-driven Poisson processes by external dead time - Application of radioluminescence from glass

Ways in which dead time can be used to constructively enhance or diminish the effects of point processes that display bunching in the shot-noise-driven doubly stochastic Poisson point process (SNDP) are discussed. Interrelations between photocount bunching arising in the SNDP and the antibunching character arising from dead-time effects are investigated. It is demonstrated that the dead-time-modified count mean and variance for an arbitrary doubly stochastic Poisson point process can be obtained from the Laplace transform of the single-fold and joint-moment-generating functions for the driving rate process. The theory is in good agreement with experimental values for radioluminescence radiation in fused silica, quartz, and glass, and the process has many applications in pulse, particle, and photon detection.

Saleh, B. E. A.↗

Observation of gamma-ray bursts from 10 keV to 9 MeV

Time histories and count-rate spectra of some of the gamma-ray bursts detected by the spectrometer on the Solar Maximum Mission between Feb. 20, 1980, and May 1981 are presented. Individual peaks observed in some of the bursts are found to differ significantly in hardness from one another. The similarity in the time profiles in the different energy bands is seen as suggesting that photons spanning two decades in energy are produced by the same mechanism. It is noted that all of the bursts are detected to energies greater than approximately 1 MeV. Two of the spectra presented are seen as being well fit by single power laws; the indices, however, are strikingly different. The other two sepctra require either two power laws or an exponential function. No clear evidence is found for the existence of narrow line features in any of the bursts.

Share, G. H.↗