Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Manufacturability and performance response of developed Ni-based alloys for reactor environments

Under the Advanced Materials and Manufacturing Technologies program, two Ni-based alloys fabricated by laser powder bed fusion (LPBF) at ORNL and laser powder directed energy deposition (LP-DED) at INL have been evaluated: γ′-strengthened Haynes 282 and solution-strengthened Inconel 625. Printing defects were observed in the LPBF 282 alloy fabricated using a Renishaw AM250 machine, likely due to particle spattering during printing. For both the LPBF and LP-DED 282 alloys, annealing at 1,180°C for 1 h resulted in partial recrystallization and a bimodal grain distribution, while subsequent aging for 4 h at 800°C led to the formation of a high density of nano size γ′-strengthening precipitates. Creep testing performed at 750°C revealed lower creep life and ductility for the LPBF and LP-DED 282 compared with wrought 282. X-ray computed tomography combined with optical and scanning electron microscopy microstructural characterization revealed crack formation in the LPBF 282 alloy during creep testing, initiated either from printing defects or from creep cavitation at grain boundaries. Creep cavitation and cracking at grain boundaries were also observed for the LP-DED 282 alloy, and optimization of the printing strategies and post heat treatments will be needed to fabricate high performance 282 components for high temperature nuclear applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Synthesis of cuboid BiOCl nanosheets coupled with CdS quantum dots by region-selective deposition process with enhanced photocatalytic activity

Highlights: • Region-selective deposition process was adopted to prepare high-dispersed CdS QDs/BiOCl nanocomposites consisting of cuboid BiOCl nanosheets exposing (001) facet and CdS QDs with size of 5–10 nm. • The TGA was used as bridge linked the CdS QDs and BiOCl, which enables CdS QDs spread homogeneously on the (001) facet of BiOCl. • The optical absorption properties and charge transfer efficiency of CdS QDs/BiOCl nanocomposites are much improved owing to the widespread heterojunction between CdS QDs and BiOCl. • The photocatalytic degradation activities of CdS QDs/BiOCl composites are excellent for MO dyes and phenol contaminants under simulated solar and UV light, respectively. - Abstract: A facile region-selective deposition process was adopted to prepare high-dispersed CdS QDs on BiOCl nanosheets with the surface modification of thioglycollic acid (TGA). The samples were systematically characterized by XRD, SEM, TEM, HRTEM, EDS, XPS, UV–vis DRS, EIS and PL. The results indicate that CdS QDs with size of 5–10 nm dispersed uniformly on the surface of cuboid BiOCl nanosheets. The photocatalytic performance tests reveal that the CdS QDs-3%/BiOCl composite exhibits an excellent photocatalytic activity, which is over 4.0 and 4.8 times as high as pure BiOCl for methyl orange (MO) and phenol photodegradation rate under simulated solar light and UV light illumination, respectively. The enhanced photocatalytic performance of the CdS QDs/BiOCl composites should be attributed to the improved visible light absorption and the high migration efficiency of the photogenerated electron-holes due to the matched band gap and the widespread heterostructure between CdS QDs and BiOCl.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Numerical Simulations of Flow-Induced Deflections in MITR LEU Fuel Plate Due to Channel Size Disparity

The hydromechanical stability of the fuel plates in parallel coolant channels of a Materials Testing Reactor (MTR) fuel element design is of great importance to the safety of research and test reactors. Previous analytical, experimental, and numerical efforts focused on parallel channels with the same or similar size; also, in the prior numerical simulations, the fuel plate was often assumed to be perfectly flat. This work presents the results of a fluid-structure interaction simulation performed to evaluate the flow-induced deflections of the fuel plates in the low-enriched uranium (LEU, <20 wt% 235 U) fuel element design for the conversion (from highly enriched uranium) of the Massachusetts Institute of Technology Reactor (MITR-II, also referred to as MITR). Various manufacturing and assembly tolerances of the MITR LEU elements are considered in the analysis, and the effects of channel size disparity, nonideal plate shape, and flow rate uncertainty are investigated. Results show that, for all cases analyzed, the deflection occurs toward the larger channel, and the change in any channel stripe remains small (less than 0.021 mm) compared to fabrication tolerances. In addition to simulation work, a hydraulic performance test of the MITR LEU fuel element is currently planned to support conversion to the use of LEU fuel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photon Irradiation Effects on the Enduray Vision System for Nuclear Inspections

Video cameras with greater radiation hardening are needed for the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems has developed a radiation-hardened vision system for nuclear energy applications. The program described in this report provided radiation-hardness testing of this vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on several of Vega Wave System’s cameras at dose rates ranging from 1 kGy/hr up to 10 kGy/hr and up to total doses of >500 kGy. The results were excellent, providing proof of the camera system’s immunity to radiation effects at all levels tested.

36 MATERIALS SCIENCE↗

Thrust stand for vertically oriented electric propulsion performance evaluation

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.

42 ENGINEERING↗

Manufacturability and performance response of developed Ni-based alloys for reactor environments

Under the Advanced Materials and Manufacturing Technologies program, two Ni-based alloys fabricated by laser powder bed fusion (LPBF) at Oak Ridge National Laboratory and by laser powder directed energy deposition (LP-DED) at Idaho National Laboratory have been evaluated: γ′-strengthened Haynes 282 and solution-strengthened Inconel 625. Printing defects were observed in the LPBF 282 alloy fabricated using a Renishaw AM250 machine, likely due to particle spattering during printing. For both the LPBF and LP-DED 282 alloys, annealing at 1,180°C for 1 h resulted in partial recrystallization and a bimodal grain distribution, and subsequent aging for 4 h at 800°C led to the formation of a high density of nano-size γ′-strengthening precipitates. Creep testing performed at 750°C revealed lower creep life and ductility for the LPBF and LP-DED 282 compared with wrought 282. X-ray computed tomography combined with optical and scanning electron microscopy microstructural characterization revealed crack formation in the LPBF 282 alloy during creep testing, initiated either from printing defects or from creep cavitation at grain boundaries. Creep cavitation and cracking at grain boundaries were also observed for the LP-DED 282 alloy, and optimization of the printing strategies and postheat treatments will be needed to fabricate high-performance 282 components for high-temperature nuclear applications.

36 MATERIALS SCIENCE↗

Development of a mechanistic thermal aging model for Grade 91

This report provides a summary on understanding and predicting the effects of long-term thermal aging on microstructure and tensile properties of G91 to corroborate the ASME Code rules in strength reduction due to elevated temperature service. The research is to support the design and long-term operation of G91 structural components in sodium-cooled fast reactors (SFRs). The report is a Level 2 deliverable in FY18 (M2NT-18AN050502061), under the Work Package NT-18AN05050206, “G91 Code Extension Testing” performed by the Argonne National Laboratory (ANL), as part of the Advanced Materials Development Program for Fast Reactors. The thermal aging study of G91 involves three types of thermally-aged specimens: (1) specimens machined from two heats of G91, G91-H1 and H30176 that have been tested for the Advanced Materials Development Programs in the past years. These specimens were aged at 550, 600, and 650°C for times up to ~64,000 h; (2) specimens fabricated from the heads of the archived crept specimens (13 in total) of six heats of G91, H5349, H30394, H30383, H10148, H30176. These specimens were aged at 427 - 538°C and for times up to 132,647 h; (3) specimens made from a tube removed from the Kingston coal-fired power plant after exposure for 155,000 h at 550°C. These three sets of specimens provide a comprehensive data set for understanding and predicting the effect of long-term thermal aging on microstructure and tensile properties of G91. Microstructural analysis of the thermally-aged G91 revealed that thermal aging causes significant microstructural changes: (1) the tempered martensite formed during tempering is unstable, and suffers significant recovery during aging, manifested by an increase in subgrain width, a decrease in subgrain length, and a decrease in subgrain aspect ratio (i.e. subgrains become more equiaxed) as the aging temperature and time increase. The subgrain recovery is facilitated by the reduction of dislocation density within subgrains; (2) M23C6 carbides in the as-received G91 are distributed along grain and subgrain boundaries and play an important role as pinning obstacles against subgrain coarsening. M23C6 carbides coarsen during aging, and the coarsening of M23C6 carbides reduces the pinning force on the boundaries; (3) MX carbonitrides in the as-received G91 are distributed uniformly within subgrains, providing the precipitation hardening effect. They coarsen with increasing aging temperature and time, but the coarsening rate is low; (3) a new phase, the Laves phase intermetallic forms during aging. The formation of the Laves phase removes the Mo solutes from the matrix, reducing the solid solution strengthening effect. The Laves phase particles grow rapidly once they are nucleated, and they precipitate primarily along boundaries. They may have a pinning effect on boundaries, but should provide little to the alloy strength. The evolution of each microstructural constituent during thermal aging can be well described by individual microstructural models. The estimated activation energy for MX coarsening was 175 kJ/mol, equivalent to the activation energy for boundary and core diffusion in a-Fe, while the estimated activation energy for subgrain coarsening was significantly lower, ~96 kJ/mol. Thermal aging of G91 results in the reduction in the yield stress and the ultimate tensile strength but has an insignificant effect on the uniform and total elongations. The reduction in tensile strength is more pronounced as the aging temperature and time increases. The in situ tensile tests with high-energy X-rays revealed that sub-boundary strengthening plays a dominant role, and the strengthening role of M23C6 particles may be accounted for by subgrian boundary hardening, and three strengthening mechanisms can be superimposed to describe the tensile strength of G91: subgrain boundary hardening, MX precipitation hardening, and Mo solid solution strengthening. A microstructure – strength model was establ

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Improvement of the Linear System Solver for CMFD Acceleration in PROTEUS-MOC

The PROTEUS code developed under the DOE NEAMS program is a high-fidelity capable whole core transports solver based on unstructured finite element meshes [1]. PROTEUS includes three distinct transport solvers: SN, MOC and NODAL. Among them, the PROTEUS-MOC is the 3D method of characteristics (MOC) solver for extruded geometries. In order to accelerate the convergence of 3D MOC calculation, the CMFD acceleration method was implemented in PROTEUS-MOC [2]. For solving the CMFD linear system, the unpreconditioned GMRES algorithm was used in the previous work [3, 4] for implementing the CMFD scheme because of low computation cost of coarse mesh calculations. In the performance tests, we found that the overhead of the CMFD acceleration became non-negligible as the condition number of the CMFD linear system and the size of problem increase. This indicated that the CMFD overhead should be reduced in the preconditioning technique in order to improve the computational performance. In this work, the performance of CMFD acceleration was notably improved by developing and implementing the new formulation of CMFD linear system and preconditioning technique.

Jung, Yeon Sang↗

EVALUATION OF PROTON-CONDUCTING MEMBRANES FOR USE IN A SULFUR-DIOXIDE DEPOLARIZED ELECTROLYZER

The chemical stability, sulfur dioxide transport, ionic conductivity, and electrolyzer performance have been measured for several commercially available and experimental proton exchange membranes (PEMs) for use in a sulfur dioxide depolarized electrolyzer (SDE). The SDE's function is to produce hydrogen by using the Hybrid Sulfur (HyS) Process, a sulfur based electrochemical/thermochemical hybrid cycle. Membrane stability was evaluated using a screening process where each candidate PEM was heated at 80 C in 60 wt. % H{sub 2}SO{sub 4} for 24 hours. Following acid exposure, chemical stability for each membrane was evaluated by FTIR using the ATR sampling technique. Membrane SO{sub 2} transport was evaluated using a two-chamber permeation cell. SO{sub 2} was introduced into one chamber whereupon SO{sub 2} transported across the membrane into the other chamber and oxidized to H{sub 2}SO{sub 4} at an anode positioned immediately adjacent to the membrane. The resulting current was used to determine the SO{sub 2} flux and SO{sub 2} transport. Additionally, membrane electrode assemblies (MEAs) were prepared from candidate membranes to evaluate ionic conductivity and selectivity (ionic conductivity vs. SO{sub 2} transport) which can serve as a tool for selecting membranes. MEAs were also performance tested in a HyS electrolyzer measuring current density versus a constant cell voltage (1V, 80 C in SO{sub 2} saturated 30 wt% H2SO{sub 4}). Finally, candidate membranes were evaluated considering all measured parameters including SO{sub 2} flux, SO{sub 2} transport, ionic conductivity, HyS electrolyzer performance, and membrane stability. Candidate membranes included both PFSA and non-PFSA polymers and polymer blends of which the non-PFSA polymers, BPVE-6F and PBI, showed the best selectivity.

08 HYDROGEN↗

Further Development of an ISOCS - based Advanced In Situ Gamma Spectrometry Services Tool for Waste Measurements - 17452

Canberra's In Situ Object Counting System is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function while avoiding the need for radioisotope standards. The ISOCS Uncertainty Estimator tool can be used to calculate defensible systematic calibration uncertainties. However the uncertainties depend on knowledge of the properties of the item being measured and for poorly characterized materials these can be large, often leading to large costs for waste sentencing. An ISOCS-based advanced in-situ gamma spectrometry services tool has been developed to reduce those uncertainties. This system is based on generating and comparing a range of candidate geometry models that yield figures of merit indicative of improved consistency between modelled data and available diverse measurement data. The approach and results of initial performance testing have previously been published, demonstrating an analysis procedure and enhanced accuracy for measurement of a low density 200 litre waste drum, based on measurements with known sources placed at different positions. It was shown how the accuracy of assay of Am-241 in a light matrix can be significantly improved. Further analysis has now been performed, with reference to measurements of a second drum, containing a standard matrix of higher density, and with a multiple radionuclide line source (Ba-133, Cs-137, Eu-152 and Am-241). These measurements represent a more challenging waste assay scenario, corresponding to potentially much larger assay uncertainties. Our results show how the assay uncertainty can be reduced, by careful application of AIGS, from relative values of the order of 100% to a few 10's of %. Furthermore, we demonstrate, through extended analysis of the test drum data, how an AIGS measurement program can be optimized to reduce the number of required measurement positions substantially. This paper describes these new results with comment on their importance and potential application for real waste assay projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned in the Design and Use of IP1 / IP2 Flexible Packaging - 13621

For many years in the USA, Low Level Radioactive Waste (LLW), contaminated soils and construction debris, have been transported, interim stored, and disposed of, using IP1 / IP2 metal containers. The performance of these containers has been more than adequate, with few safety occurrences. The containers are used under the regulatory oversight of the US Department of Transportation (DOT), 49 Code of Federal Regulations (CFR). In the late 90's the introduction of flexible packaging for the transport, storage, and disposal of low level contaminated soils and construction debris was introduced. The development of flexible packaging came out of a need for a more cost effective package, for the large volumes of waste generated by the decommissioning of many of the US Department of Energy (DOE) legacy sites across the US. Flexible packaging had to be designed to handle a wide array of waste streams, including soil, gravel, construction debris, and fine particulate dust migration. The design also had to meet all of the IP1 requirements under 49CFR 173.410, and be robust enough to pass the IP2 testing 49 CFR 173.465 required for many LLW shipments. Tens of thousands of flexible packages have been safely deployed and used across the US nuclear industry as well as for hazardous non-radioactive applications, with no recorded release of radioactive materials. To ensure that flexible packages are designed properly, the manufacturer must use lessons learned over the years, and the tests performed to provide evidence that these packages are suitable for transporting low level radioactive wastes. The design and testing of flexible packaging for LLW, VLLW and other hazardous waste streams must be as strict and stringent as the design and testing of metal containers. The design should take into consideration the materials being loaded into the package, and should incorporate the right materials, and manufacturing methods, to provide a quality, safe product. Flexible packaging can be shown to meet the criteria for safe and fit for purpose packaging, by meeting the US DOT regulations, and the IAEA Standards for IP-1 and IP-2 including leak tightness. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of ultrananocrystalline diamond (UNCD) coatings for multipurpose mechanical pump seals.

The reliability and performance of silicon carbide (SiC) shaft seals on multipurpose mechanical pumps are improved by applying a protective coating of ultrananocrystalline diamond (UNCD). UNCD exhibits extreme hardness (97 GPa), low friction (0.1 in air) and outstanding chemical resistance. Consequently, the application of UNCD coatings to multipurpose mechanical pump seals can reduce frictional energy losses and eliminate the downtime and hazardous emissions from seal failure and leakage. In this study, UNCD films were prepared by microwave plasma chemical vapor deposition utilizing an argon/methane gas mixture. Prior to coating, the SiC seals were subjected to mechanical polishing using different grades of micron-sized diamond powder to produce different starting surfaces with well-controlled surface roughnesses. Following this roughening process, the seals were seeded by mechanical abrasion with diamond nanopowder, and subsequently coated with UNCD. The coated seals were subjected to dynamic wear testing performed at 3600 RPM and 100 psi for up to 10 days during which the seals were periodically removed and inspected. The UNCD-coated seals were examined using Raman microanalysis, scanning electron microscopy, optical profilometry, and adhesion testing before and after the wear testing. These analyses revealed that delamination of the UNCD films was prevented when the initial SiC seal surface had an initial roughness >0.1 {micro}m. In addition, the UNCD surfaces showed no measurable wear as compared to approximately 0.2 {micro}m of wear for the untreated SiC surfaces.

36 MATERIALS SCIENCE↗

Evaluation of nature and intensity of fire concrete spalling by frequency analysis of sound records

Highlights: • Original sound-based NDT method to assess the spalling form and intensity within the time of the test is proposed. • Frequency analysis of recorded sound provides a quantitative and qualitative assessment of concrete propensity to spalling. • Nature of fire concrete spalling can be categorized by a well-defined frequency value. • Waveform and spectrogram analysis delivers information on the exact number of spalling events within the performed test. The paper presents a new method for identifying the form and intensity of spalling using an analysis of the acoustic signal emitted by concrete. To assess the intensity and monitor the course of concrete spalling during fire exposure, the analysis of the recorded sound from the furnace chamber is used. The spalling intensity was determined based on signal amplitude analysis. Investigation of sound records showed that the character of spalling can be categorized by a well-defined frequency value. Based on the analysis of the Fast Fourier Transform (FFT) spectrum, the authors have distinguished the following phenomena that are the source of the signal by assigning the corresponding frequency of the sound wave vibration: explosive spalling, aggregate spalling and destructive spalling.

36 MATERIALS SCIENCE↗

Radiochemical purity of Mo and Tc solution obtained after irradiation and dissolution of Mo-100-enriched and ultra-high-purity natural Mo disks

Four irradiations of ultra-high-purity natural Mo targets and one irradiation using 97.4% Mo-100-enriched material were performed. The purpose of these irradiations was to determine whether the presence of Sn stabilizer in the H 2 O 2 used for the dissolution of sintered Mo disks can affect the radiochemical purity of the final K 2 MoO 4 in 5M KOH solution. Results from radiochemical purity tests performed using thin-layer paper chromatography show that even 2– 3× excess of Sn-stabilized H 2 O 2 typically used for dissolution of sintered Mo disks did not affect the radiochemical purity of the final product.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Liquid hydrogen pump performance and durability testing through repeated cryogenic vessel filling to 700 bar

Here, this paper reports the results of a comprehensive test of liquid hydrogen (LH 2 ) pump performance and durability conducted while cycle testing a prototype thin-lined cryogenic pressure vessel 456 times to 700 bar. This extensive LH2 pump experimental data set provides a wealth of information vital for a complete evaluation of the future potential of this promising technology for ambient temperature and cryo-compressed vessel refueling. The experiment was conducted at Lawrence Livermore National Laboratory (Livermore, CA)'s hydrogen test facility, specifically built for this experiment and including a containment vessel for safe testing of the prototype vessel and a control room for efficient monitoring. Original pump and storage instrumentation was complemented with an electric power analyzer and a boil-off mass flow meter for more complete pump characterization. The results of the experiment confirm most of the expected virtues of the LH 2 pump: rapid (3 min) refueling of the 65-liter prototype vessel at high flow rate (1.55 kgH 2 per minute on average), unlimited back to back refueling, low electricity consumption (1.1 kWh/kg H 2 ), no measurable degradation, and low maintenance. High cryogenic vessel fill density is another key performance metric that was demonstrated in an earlier publication. These virtues derive from the high density of LH 2 enabling pressurization to high density with relatively little energy consumption and high throughput from a small displacement pump. Boil-off losses as high as 27.7% of dispensed hydrogen were measured, at experimental conditions not representative of operation at a hydrogen refueling station. These losses drop to 15.4% for operation that may be representative of a small station (332 kg/day), while we anticipate less than 6% boil-off with the existing pump and Dewar with improved LH 2 delivery truck operations and a more favorable arrangement of the LH 2 pump relative to the Dewar.

08 HYDROGEN↗

Interpretation of production tests in geothermal wells with T2Well-EWASG

In the geothermal sector, being able to simulate production tests by combining surface and downhole measurements can be extremely useful, improving data interpretation and reducing the impact of unavailable field data. This is possible with T2Well, a coupled wellbore-reservoir simulator. In this study, we plugged the EWASG equation of state for high enthalpy geothermal reservoirs into T2Well and extended the function to analytically compute the heat exchange between wellbore and formation at the short times. Changes to the analytical heat exchange function were verified by comparison with wellbore-formation heat exchange numerically simulated. T2Well-EWASG was validated by reproducing the flowing pressure and temperature logs taken from literature, and by using the software for the interpretation of a short production test. Lastly, simulation results indicate that T2Well-EWASG can be effectively used to improve the interpretation of production tests performed in geothermal wells.

58 GEOSCIENCES↗