Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Paper Based Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Predictive Engineering Tools for Injection-Molded Long-Carbon-Fiber Thermoplastic Composites - FY 2015 First Quarterly Report

During the first quarter of FY 2015, the following technical progress has been made toward project milestones: 1) Autodesk delivered a new research version of ASMI to PNNL. This version includes the improved 3D fiber orientation solver, and the reduced order model (ROM) for fiber length distribution using the proper orthogonal decomposition (POD) implemented in the mid-plane, dual-domain and 3D solvers. 2) Autodesk coordinated a conference paper with PNNL reporting ASMI mid-plane fiber orientation predictions compared with the measured data for two PlastiComp plaques. This paper was accepted for presentation at the 2015 Society for Plastics Engineers (SPE) ANTEC conference. 3) The University of Illinois (Prof. Tucker) assisted team members from Purdue with fiber orientation measurement techniques, including interpretation of off-axis cross sections. 4) The University of Illinois assisted Autodesk team members with software implementation of the POD approach for fiber length modeling, and with fiber orientation modeling. 5) The University of Illinois co-authored in the SPE ANTEC paper, participated with the team in discussions of plaque data and model results, and participated in the definition of go/no-go experiments and data. 6) Purdue University (Purdue) conducted fiber orientation measurements for 3 PlastiComp plaques: fast-fill 30wt% LCF/PP center-gated, fast-fill 50wt% LCF/PA66 edge-gated and fast-fill 50wt% LCF/PA66 center-gated plaques, and delivered the fiber orientation data for these plaques at the selected locations (named A, B, and C) to PNNL. However, the data for the fast-fill 50wt% LCF/PA66 edge-gated plaque exhibited unusual variations and could not be used for the model validation. Purdue will re-measure fiber orientation for this plaque. 7) Based on discussions with the University of Illinois Purdue explained the ambiguity in the measurements of the fiber orientation components. 8) PNNL discussed with team members to establish a go/no-go decision plan for the project and submitted the established plan to DOE. 9) PNNL performed ASMI mid-plane analyses for the fast-fill center-gated 30wt% LCF/PP and 50wt% LCF/PA66 plaques and compared the predicted fiber orientations with the measured data provided by Purdue at Locations A, B, and C on these plaques. 10) Based on discussions with the University of Illinois and Autodesk, PNNL proposed a procedure to adjust fiber orientation data for Location A of the center-gated plaques so that the data can be expressed and interpreted in the flow/cross-flow direction coordinate system. 11) PNNL tested the new ASMI version received from Autodesk, examined and discussed 3D fiber orientation predictions for PlastiComp plaques. 12) PlastiComp, Inc. (PlastiComp), Toyota Research Institute North America (Toyota) and Magna Exteriors and Interiors Corp. (Magna) participated in discussions with team members on the go/no-go plan and the issues related to fiber length measurements. Toyota continued the discussion with Magna on tool modification for molding the complex part in order to achieve the target fiber length in the part.

42 ENGINEERING↗

Life Extension of Nuclear Plant Facilities through Monitoring and Detailed Analysis - 16175

The UK has accumulated a substantial legacy of radioactive waste from various civil nuclear and defence programmes. Presently, however most of the UK radioactive waste is generated from nine power stations which generate approximately one sixth of the of the country's electricity. Irradiated fuel is removed from these reactors and safe management of the radioactive solid and liquid effluents is required. The safe management of these effluents is essential. Sellafield, in West Cumbria UK, contains two reprocessing plants, one designed to process nuclear fuel from Magnox reactors (CO{sub 2} cooled with Uranium bar fuel) and the other to process nuclear fuel from Advanced Gas cooled Reactors and Pressurized Water Reactors. The reprocessing stage enables extraction of fissile material for recycling. This leaves a volume of dilute but high-level waste. The high-level radioactive liquid waste is concentrated to reduce its volume and then incorporated into borosilicate glass, using a process called vitrification. The glass is then poured into stainless steel containers and placed in long term storage. This required concentration of HLW liquor is achieved using a suite of aging evaporators. All evaporators are of similar design constructed from corrosion resistant stainless steel having dimensions height ∼11 m, internal diameter 3.05 m and capable of holding 13.7 m{sup 3} of liquor. The basic principle of operation is to heat the dilute liquor under partial vacuum, at constant volume, until the target concentration is achieved. Heating of the liquor is achieved using steam heated coils within the evaporator, and steam in the jacket which surrounds the lower half of the evaporator vessel. The evaporator is then brought to atmospheric pressure and the concentrated liquor is ejected whilst hot. The evaporator is then cooled with water cooled coils and a water filled jacket. New dilute liquor is then added for a new batch. The process is then repeated. As the evaporators reach the end of their original design life accurate prediction of the current condition of nuclear plant facilities is essential to safely justify continued plant operation by ensuring structural integrity. This poses a significant challenge as many aging UK nuclear facilities were not inherently built with inspection in mind. The potential life limiting components of the HA evaporators at Sellafield are the surfaces that contact the product liquor at elevated temperatures i.e. the steam heated surfaces of the coils within the evaporator vessel and the vessel base and wall surrounded by the steam jacket. Each heating component is critical to the operational life of the evaporator - the removal from service of a coil heating component significantly reduces the operational flexibility and remnant life of this plant. Over the last decade a variety of cutting-edge expertise and methodologies have been utilised to accurately measure and then predict the current condition of the plant and also to predict its remnant life. This paper provides an overview of the development of several techniques deployed, namely non-destructive testing/inspection, in-house software development and finite element modelling. These methods have been validated by lab-scale or full-scale experiments along with historical plant data. These techniques have been evolved and refined for over a decade, providing vital insights into the physical behaviour of this complex reprocessing system. This enables not only accurate assessment of the current condition of the plant equipment but also allows scientifically underpinned predictions to be made of how it will behave into the future. This is critical for Sellafield as this knowledge feeds into their safety case to the Office of Nuclear Regulation to justify continued operation. It is concluded that this integrated approach provides a robust analysis tool which has driven change and optimisation of plant procedures ensuring continued safe operation whilst extending the life of the facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of the Mini-Sulfide Sulfite Anthraquinone (MSS-AQ) Pulping Process and Black Liquor Gasification in a Pulp Mill

As many of the recovery boilers and other pieces of large capital equipment of U.S. pulp mills are nearing the end of their useful life, the pulp and paper industry will soon need to make long-term investments in new technologies. The ability to install integrated, complete systems that are highly efficient will impact the industry’s energy use for decades to come. Developing a process for these new systems is key to the adoption of state-of-the-art technologies in the Forest Products industry. This project defined an integrated process model that combines mini-sulfide sulfite anthraquinone (MSS-AQ) pulping and black liquor gasification with a proprietary desulfurization process developed by the Research Triangle Institute. Black liquor gasification is an emerging technology that enables the use of MSS-AQ pulping, which results in higher yield, lower bleaching cost, lower sulfur emissions, and the elimination of causticization requirements. The recently developed gas cleanup/absorber technology can clean the product gas to a state suitable for use in a gas turbine and also regenerate the pulping chemicals needed to for the MSS-AQ pulping process. The combination of three advanced technologies into an integrated design will enable the pulping industry to achieve a new level of efficiency, environmental performance, and cost savings. Because the three technologies are complimentary, their adoption as a streamlined package will ensure their ability to deliver maximum energy and cost savings benefits. The process models developed by this project will enable the successful integration of new technologies into the next generation of chemical pulping mills. When compared to the Kraft reference pulp, the MSS-AQ procedures produced pulps with a 10-15 % yield benefit and the ISO brightness was 1.5-2 times greater. The pulp refined little easier and had a slightly lower apparent sheet density (In both the cases). At similar levels of tear index the MSS-AQ pulps also produced a comparable tensile and burst index pulps. Product gas composition determined using computer simulations The results demonstrate that RVS-1 can effectively remove > 99.8% of the H2S present in simulated synthesis gas generated from the gasification of black liquor. This level of sulfur removal was consistent over simulated synthesis gas mixtures that contained from 6 to 9.5 vol % H2S.A significant amount of the sulfur in the simulated syngas was recovered as SO2 during regeneration. The average recovery of sulfur as SO2 was about 75%. Because these are first cycle results, this sulfur recovery is expected to improve. Developed WINGems model of the process.The total decrease in variable operating costs for the BLG process compared to the HERB was in excess of $6,200,000 per year for a mill producing 350,000 tons of pulp per year. This represents a decrease in operating cost of about $17.7/ton of oven dry pulp produced. There will be additional savings in labor and maintenance cost that has not been taken into account. The capital cost for the MSSAQ based gasifier system was estimated at $164,000,000, which is comparable to a High Efficiency Recovery Boiler. The return on investment was estimated at 4%. A gasifier replacement cannot be justified on its own, however if the recovery boiler needs to be replaced the MSSAQ gasifier system shows significantly higher savings. Before black liquor based gasifer technology can be commercialized more work is necessary. The recovery of the absorbed sulfur in the absorbent as sulfur dioxide is only 75%. This needs to be greater than 90% for economical operation. It has been suggested that as the number of cycles is increased the sulfur dioxide recovery might improve. Further research is necessary. Even though a significant amount of work has been done on a pilot scale gasifiers using liquors containing sulfur, both at low and high temperatures the lack of a commercial unit is an impediment to the implementation of the MSSAQ technology. The implementation of a commercial unit needs to be facilated before the benefits of the MSSAQ technology with ZnO absorbtion will become acceptable to the paper industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrolytically Assisted Surface Decontamination (EASD{sup TM}) for POCO Operations - 20282

NNL in collaboration with C-Tech Innovation Ltd and Sellafield Ltd has been exploring innovative technologies to enable a significant reduction of radiological hazards within facilities during the Post Operational Clean Out (POCO) phase of a nuclear plant's life cycle. Reducing the hazard by effectively decontaminating plants in-situ during POCO delivers huge cost reductions for future decommissioning operations. These cost reduction benefits are realized by reducing the number and complexity of remote operations as well as lowering the long-term waste disposal costs. Whilst chemical decontamination can achieve the desired level of decontamination, applying aggressive chemical reagents is hazardous, potentially difficult to control and requires there to be complimentary effluent treatment and waste routes. This work has aimed to develop flexible and controllable decontamination processes which could be operated without the additional complexity and issues associated with chemical decontamination. The processes needed to be relatively fast and effective to minimize the time operators would spend in an active area. In addition, there was a driver to produce decontamination methodologies which generated a secondary waste compatible with current routes and which takes advantage of current waste capacity. The strategy therefore was to come up with a solution that works with, rather than against, the science and engineering behind process plants at Sellafield. Electrolytically Assisted Surface Decontamination (EASD{sup TM}) is an innovative electrochemical decontamination process (developed by NNL and C-Tech Innovation Ltd) that can remove activity from contaminated metal in very short time periods. Application of the patented electric waveform to the surface when treating contaminated metal with nitric acid has been shown to significantly enhance the decontamination performance. When compared to proposed baseline washout procedures at Sellafield, the only change to the process is the applied electrical waveform which is temporary and controllable. The current causes dissolution of the metal surface being decontaminated which leads to activity transferring from the plant item into the nitric acid effluent stream. This innovation has the potential to transform the POCO process and allow a nitric acid based washout approach to deliver POCO quickly and cost effectively within the existing infrastructure. Several devices have now been designed that incorporate this EASD{sup TM} technology and enable the decontamination process to be applied to a range items commonly identified as being contaminated during nuclear decommissioning programmes such as pipework, tanks and hotspots of walls/floors. Inactive and active laboratory-scale testing has been completed using both simulated and 'real-life' contaminated (low level waste) metallic items retrieved from different nuclear sites. Active trials demonstrated that contaminated items could be treated to free release levels within minutes. Engineering scale tests are currently being performed, with guidance from Sellafield's system engineers and plant managers, to provide the necessary re-assurance the designed devices could be successfully deployed in an on-plant scenario. The final stage of this development work is to carry out an active demonstration of the decontamination technology on Thorp at Sellafield. This paper aims to highlight progress made to date with the EASD{sup TM} technology and, more specifically, the development of an in-situ decontamination device for deployment within radioactive pipework. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of the Advanced D1S for Shutdown Dose Rate Calculations in Fusion Reactors

The assessment of the shutdown dose rate due to neutron activation is fundamental for shielding design, materials selection, licensing and planning of maintenance operations in high performances fusion devices. The shutdown dose rate calculations require the combined use of radiation transports and inventory codes. The typical approach consists in a two steps procedure. A pure neutron transport simulation is performed in a first step to calculate the spatial distribution of neutron spectra. The results are used as input for an activation calculation that provides the decay gamma source used in a second step for a pure gamma transport simulation (rigorous-two step, R2S). The Direct 1-Step (D1S) approach has been developed more than ten years ago by ENEA and the ITER team: this technique relies on a coupled neutron-decay gamma transport in a single simulation. It is based on the use of a modified version of the MCNP5 Monte Carlo code with specially tailored nuclear cross-section data for transport and FISPACT inventory code for temporal behaviour. The 'Advanced-D1S' is an improved version of D1S in which additional computational features have been introduced, such as the mesh tally capability and continuous time evolution assessment of the dose rate in single run dose. It has been validated through measurements at JET tokamak and comparison with R2S codes and a future benchmark experiment during next high performance deuterium-tritium campaign is in preparation at JET. It has also been extensively used for ITER calculations and recently applied to DEMO assessment. Present limitations and in progress code improvement strategy are described and discussed in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

A decision support system prototype including human factors based on the TOGA meta-theory approach

The human contribution to the risk of operation of complex technological systems is often not negligible and sometimes tends to become significant, as shown by many reports on incidents and accidents occurred in the past inside Nuclear Power Plants (NPPs). An error of a human operator of a NPP can derive by both omission and commission. For instance, complex commission errors can also lead to significant catastrophic technological accidents, as for the case of the Three Mile Island accident. Typically, the problem is analyzed by focusing on the single event chain that has provoked the incident or accident. What is needed is a general framework able to include as many parameters as possible, i.e. both technological and human factors. Such a general model could allow to envisage an omission or commission error before it can happen or, alternatively, suggest preferred actions to do in order to take countermeasures to neutralize the effect of the error before it becomes critical. In this paper, a preliminary Decision Support System (DSS) based on the so-called (-) TOGA meta-theory approach is presented. The application of such a theory to the management of nuclear power plants has been presented in the previous ICAPP 2011. Here, a human factor simulator prototype is proposed in order to include the effect of human errors in the decision path. The DSS has been developed using a TRIGA research reactor as reference plant, and implemented using the LabVIEW programming environment and the Finite State Machine (FSM) model The proposed DSS shows how to apply the Universal Reasoning Paradigm (URP) and the Universal Management Paradigm (UMP) to a real plant context. The DSS receives inputs from instrumentation data and gives as output a suggested decision. It is obtained as the result of an internal elaborating process based on a performance function. The latter, describes the degree of satisfaction and efficiency, which are dependent on the level of responsibility related to each professional role. As an application, we present the simulation of the discussed error, e.g. the unchecked extraction of the control rods during a power variation maneuver and we show how the effect of human errors can affect the performance function, giving rise to different countermeasures which could call different operator figures into play, potentially not envisaged in the standard procedure. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Debunking common myths in coastal circulation modeling

Despite tremendous progress in algorithm development, computational efficiency and transition into operations over the past two decades, coastal modeling still lacks scientific rigor due to proliferation of many ‘gray’ areas related to various modeling choices made by modelers. Here, in this paper, we propose some guiding principles for the modeling community to improve performance, and we also debunk commonly held myths that make the coastal modeling lack rigor. Using our own experience in developing seamless cross-scale unstructured-grid based models for the past two decades, we describe in unprecedented detail the end-to-end modeling process (i.e., from digital elevation models (DEMs) to mesh generation to post analysis), and demonstrate that defensible modeling is within reach for any end user by following three guiding principles: (1) Bathymetry is a first order forcing in coastal domains and thus should be respected in all aspects of modeling; (2) Oceanographic processes are driven across multiple spatial scales and so models should enable appropriate resolution as needed; and (3) Model assessment should focus on physical processes. Through qualitative and quantitative model assessments, we demonstrate the fundamental role played by bathymetry/topography as embedded in DEMs in making the results defensible, which is unfortunately glossed over in many modeling studies. Focusing on process-based assessment simplifies the calibration process. A major conclusion of this work is that model developers and operators should maximize the scientific rigor for in silico oceanography by avoiding some common pitfalls that rely on error compensation at the expense of representation of physical system processes. We present some best practice procedures for defensive and trustworthy numerical modeling.

54 ENVIRONMENTAL SCIENCES↗

Vector tomography for reconstructing electric fields with non-zero divergence in bounded domains

In vector tomography (VT), the aim is to reconstruct an unknown multi-dimensional vector field using line integral data. In the case of a 2-dimensional VT, two types of line integral data are usually required. These data correspond to integration of the parallel and perpendicular projection of the vector field along the integration lines and are called the longitudinal and transverse measurements, respectively. In most cases, however, the transverse measurements cannot be physically acquired. Therefore, the VT methods are typically used to reconstruct divergence-free (or source-free) velocity and flow fields that can be reconstructed solely from the longitudinal measurements. In this paper, we show how vector fields with non-zero divergence in a bounded domain can also be reconstructed from the longitudinal measurements without the need of explicitly evaluating the transverse measurements. To the best of our knowledge, VT has not previously been used for this purpose. In particular, we study low-frequency, time-harmonic electric fields generated by dipole sources in convex bounded domains which arise, for example, in electroencephalography (EEG) source imaging. We explain in detail the theoretical background, the derivation of the electric field inverse problem and the numerical approximation of the line integrals. We show that fields with non-zero divergence can be reconstructed from the longitudinal measurements with the help of two sparsity constraints that are constructed from the transverse measurements and the vector Laplace operator. As a comparison to EEG source imaging, we note that VT does not require mathematical modeling of the sources. By numerical simulations, we show that the pattern of the electric field can be correctly estimated using VT and the location of the source activity can be determined accurately from the reconstructed magnitudes of the field. - Highlights: • Vector tomography is used to reconstruct electric fields generated by dipole sources. • Inverse solutions are based on longitudinal and transverse line integral measurements. • Transverse line integral measurements are used as a sparsity constraint. • Numerical procedure to approximate the line integrals is described in detail. • Patterns of the studied electric fields are correctly estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is examined, including attenuation for transmission measurement of density and concentration. It was determined that transmission-corrected gamma-ray spectra provide a reliable way to monitor the 235 U concentration of uranyl nitrate solution in transfer pipes in NUCPs. Furthermore, existing predictive and analysis methods are adequate to design and realize practical designs. The 137 Cs transmission source employed in this work is viable but not optimal for 235 U densitometry determination. Validated simulations assessed the viability of 133 Ba and 57Co as alternative densitometry sources. All three gamma-ray detectors are viable for monitoring natural uranium feed; although high-purity germanium is easiest to interpret, it is, however, the least attractive as an installation instrument. Overall, for monitoring throughput in a facility such as UNCLE, emulating the uranium concentration and pump speeds of the Springfields conversion facility in the United Kingdom, an uncertainty of less than 0.17% is required in order to detect the diversion of 1 SQ of uranyl nitrate through changes in uranium concentration over an accountancy period of one year with a detection probability of 50%. As a result, calibrated gamma-ray detection systems are capable of determining the concentration of uranium content in NUCPs, it is only in combination with verifiable operator declarations and supporting data, such as flow rate and enrichment, that safeguards conclusions can be drawn.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A procedure for seismic risk reduction in Campania Region

The Campania Region has set and performed a peculiar procedure in the field of seismic risk reduction. Great attention has been paid to public strategic buildings such as town halls, civil protection buildings and schools. The Ordinance 3274 promulgate in the 2004 by the Italian central authority obliged the owners of strategic buildings to perform seismic analyses within 2008 in order to check the safety of the structures and the adequacy to the use. In the procedure the Campania region, instead of the local authorities, ensure the complete drafting of seismic checks through financial resources of the Italian Government. A regional scientific technical committee has been constituted, composed of scientific experts, academics in seismic engineering. The committee has drawn up guidelines for the processing of seismic analyses. At the same time, the Region has issued a public competition to select technical seismic engineering experts to appoint seismic analysis in accordance with guidelines. The scientific committee has the option of requiring additional documents and studies in order to approve the safety checks elaborated. The Committee is supported by a technical and administrative secretariat composed of a group of expert in seismic engineering. At the moment several seismic safety checks have been completed. The results will be presented in this paper. Moreover, the policy to mitigate the seismic risk, set by Campania region, was to spend the most of the financial resources available on structural strengthening of public strategic buildings rather than in safety checks. A first set of buildings of which the response under seismic action was already known by data and studies of vulnerability previously realised, were selected for immediate retrofitting designs. Secondly, an other set of buildings were identified for structural strengthening. These were selected by using the criteria specified in the Guide Line prepared by the Scientific Committee and based on data obtained by the first set of safety checks. The strengthening philosophy adopt in the projects will be described in the paper.

58 GEOSCIENCES↗

A Data-Driven Framework for Power System Event Type Identification via Safe Semi-Supervised Techniques

Herein this paper investigates the use of phasor measurement unit (PMU) data with deep learning techniques to construct real-time event identification models for transmission networks. Increasing penetration of distributed energy resources represents a great opportunity to achieve decarbonization, as well as challenges in systematic situational awareness. When high-resolution PMU data and sufficient manually recorded event labels are available, the power event identification problem is defined as a statistical classification problem that can be solved by numerous cutting-edge classifiers. However, in real grids, collecting tremendous high-quality event labels is quite expensive. Utilities frequently have a large number of event records without in-depth details (i.e., unlabeled events). To bridge this gap, we propose a novel semi-supervised learning-based method to improve the performance of event classifiers trained with a limited number of labeled events by exploiting the information from massive unlabeled events. In other words, compared to existing data-driven methods, our method requires only a small portion of labeled data to achieve a similar level of accuracy. Meanwhile, this work discusses and addresses the performance degradation caused by class distribution mismatch between the training set and the real applications. Based on the proposed safe learning mechanism, our model does not directly use all unlabeled events during model training, but selectively uses them through a comprehensive evaluation procedure. Numerical studies on a sizable PMU dataset have been used to validate the performance of the proposed method.

42 ENGINEERING↗

Multiscale water drop contact angles at selected silica surfaces

In this paper, multiscale advancing contact angles for glycerol/water drops at silica surfaces are reported for millidrops, submicron-drops, and nanodrops. Selected silica surfaces were muscovite, silicon, and talc. The contact angles for millidrops (1–2 mm) were determined by the traditional sessile drop technique. For submicron-drops (0.1–1.0 μm), a hollow tip Atomic Force Microscope (AFM) procedure was used. The contact angles for nanodrops (~7 nm) were examined from Molecular Dynamics (MD) simulation. The results were compared to evaluate the effect of drop size on the contact angle. In the case of the hydrophobic talc surface, the 75° advancing contact angle did not vary significantly with drop size. For the hydrophilic muscovite surface, the water drop wet the surface and an advancing contact angle of about 10° was found for the millidrops and submicron-drops. However, for the MD simulated nanodrops, attachment and spreading of the ~7 nm drop created a 2D film of molecular dimensions, the contact angle of which was difficult to define and varied from 0° to 17°. Perhaps of equal interest from the MD simulation results was that the spreading of the glycerol/water nanodrop at the muscovite surface resulted in crystallographic directional transport of water molecules to the extremities of the 2D film. Such separation and segregation left the center of the film with an increased concentration of glycerol. Based on these results, the line tension, which has been found in other investigations to account for contact angle decrease with a decrease in drop size, does not seem to be a significant factor in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of intelligent instruments with embedded HTTP servers for control and data acquisition in a cryogenic setup—The hardware, firmware, and software implementation

The power of Ethernet for control and automation technology is being largely understood by the automation industry in recent times. Ethernet with HTTP (Hypertext Transfer Protocol) is one of the most widely accepted communication standards today. Ethernet is best known for being able to control through internet from anywhere in the globe. The Ethernet interface with built-in on-chip embedded servers ensures global connections for crate-less model of control and data acquisition systems which have several advantages over traditional crate-based control architectures for slow applications. This architecture will completely eliminate the use of any extra PLC (Programmable Logic Controller) or similar control hardware in any automation network as the control functions are firmware coded inside intelligent meters itself. Here, we describe the indigenously built project of a cryogenic control system built for linear accelerator at Inter University Accelerator Centre, known as “CADS,” which stands for “Complete Automation of Distribution System.” CADS deals with complete hardware, firmware, and software implementation of the automated linac cryogenic distribution system using many Ethernet based embedded cryogenic instruments developed in-house. Each instrument works as an intelligent meter called device-server which has the control functions and control loops built inside the firmware itself. Dedicated meters with built-in servers were designed out of ARM (Acorn RISC (Reduced Instruction Set Computer) Machine) and ATMEL processors and COTS (Commercially Off-the-Shelf) SMD (Surface Mount Devices) components, with analog sensor front-end and a digital back-end web server implementing remote procedure call over HTTP for digital control and readout functions. At present, 24 instruments which run 58 embedded servers inside, each specific to a particular type of sensor-actuator combination for closed loop operations, are now deployed and distributed across control LAN (Local Area Network). A group of six categories of such instruments have been identified for all cryogenic applications required for linac operation which were designed to build this medium-scale cryogenic automation setup. These devices have special features like remote rebooters, daughter boards for PIDs (Proportional Integral Derivative), etc., to operate them remotely in radiation areas and also have emergency switches by which each device can be taken to emergency mode temporarily. Finally, all the data are monitored, logged, controlled, and analyzed online at a central control room which has a user-friendly control interface developed using LabVIEW{sup ®}. This paper discusses the overall hardware, firmware, software design, and implementation for the cryogenics setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-R-05: Multidimensional Imaging Radiomics-Geodesics: A Novel Manifold Learning Based Automatic Feature Extraction Method for Diagnostic Prediction in Multiparametric Imaging

Purpose: Multiparametric radiological imaging is used for diagnosis in patients. Potentially extracting useful features specific to a patient’s pathology would be crucial step towards personalized medicine and assessing treatment options. In order to automatically extract features directly from multiparametric radiological imaging datasets, we developed an advanced unsupervised machine learning algorithm called the multidimensional imaging radiomics-geodesics(MIRaGe). Methods: Seventy-six breast tumor patients underwent 3T MRI breast imaging were used for this study. We tested the MIRaGe algorithm to extract features for classification of breast tumors into benign or malignant. The MRI parameters used were T1-weighted, T2-weighted, dynamic contrast enhanced MR imaging (DCE-MRI) and diffusion weighted imaging(DWI). The MIRaGe algorithm extracted the radiomics-geodesics features (RGFs) from multiparametric MRI datasets. This enable our method to learn the intrinsic manifold representations corresponding to the patients. To determine the informative RGF, a modified Isomap algorithm(t-Isomap) was created for a radiomics-geodesics feature space(tRGFS) to avoid overfitting. Final classification was performed using SVM. The predictive power of the RGFs was tested and validated using k-fold cross validation. Results: The RGFs extracted by the MIRaGe algorithm successfully classified malignant lesions from benign lesions with a sensitivity of 93% and a specificity of 91%. The top 50 RGFs identified as the most predictive by the t-Isomap procedure were consistent with the radiological parameters known to be associated with breast cancer diagnosis and were categorized as kinetic curve characterizing RGFs, wash-in rate characterizing RGFs, wash-out rate characterizing RGFs and morphology characterizing RGFs. Conclusion: In this paper, we developed a novel feature extraction algorithm for multiparametric radiological imaging. The results demonstrated the power of the MIRaGe algorithm at automatically discovering useful feature representations directly from the raw multiparametric MRI data. In conclusion, the MIRaGe informatics model provides a powerful tool with applicability in cancer diagnosis and a possibility of extension to other kinds of pathologies. NIH (P50CA103175, 5P30CA006973 (IRAT), R01CA190299, U01CA140204), Siemens Medical Systems (JHU-2012-MR-86-01) and Nivida Graphics Corporation.

60 APPLIED LIFE SCIENCES↗

International Low Level Waste Management Practices and Technical Bases for Very Low Level Waste Classification - 19415

Different countries around the globe use varying schemes for the classification of radioactive waste. Many countries use adaptations of the International Atomic Energy Agency (IAEA) waste classification scheme. The United States uses the Class A, B, and C waste classification scheme that is loosely based on the IAEA concepts. Classification may be based on concentration limits or dose rate limits or a combination of concentration and dose rate limits. In some countries the existence of very low-level waste categories allows nuclear power plant waste to be disposed of in hazardous waste or shallow land burial sites separate from low and intermediate level waste disposal facilities. In the United States, the very low-level waste (VLLW) classification does not exist. Nuclear power plants use alternative disposal procedures under 10CFR20.2002 and other licensed processes in agreement states in order to dispose of very low activity waste in hazardous waste disposal sites. [1] Disposal of VLLW in hazardous waste or separate VLLW facilities is generally more cost effective than disposing of waste in radioactive waste sites and is protective of the health and safety of the public. This can become an important factor when large volumes of very low activity waste are generated during decommissioning of nuclear power plants. The Electric Power Research Institute (EPRI) Radiation Safety (RS) Program has developed technical bases for the establishment of a very low-level waste category. EPRI studied how VLLW waste is defined, managed, and disposed of in various countries. This included the study of disposal site design, characteristics, and how these sites protect the health and safety of the environment and the public from low levels of radioactivity. EPRI conducted a cost benefit analysis to understand the economic impact of disposing VLLW in hazardous waste disposal sites versus low-level waste disposal sites. Finally, EPRI calculated potential radionuclide limits that may be used to define very low-level waste. The purpose of this work was to provide an example of how one might approach defining limits for VLLW. The same or similar approaches could be applied to derive radionuclide limits for different dose limit objectives. This paper presents the results of research that explored the waste management and disposal practices at six countries around the world with additional focus and details on the implementation of the very low-level waste category. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An input-output procedure for calculating economy-wide economic impacts in supply chains using homeland security consequence analysis tools.

Sandia National Laboratories has developed several models to analyze potential consequences of homeland security incidents. Two of these models (the National Infrastructure Simulation and Analysis Center Agent-Based Laboratory for Economics, N-ABLE{trademark}, and Loki) simulate detailed facility- and product-level consequences of simulated disruptions to supply chains. Disruptions in supply chains are likely to reduce production of some commodities, which may reduce economic activity across many other types of supply chains throughout the national economy. The detailed nature of Sandia's models means that simulations are limited to specific supply chains in which detailed facility-level data has been collected, but policymakers are often concerned with the national-level economic impacts of supply-chain disruptions. A preliminary input-output methodology has been developed to estimate national-level economic impacts based upon the results of supply-chain-level simulations. This methodology overcomes two primary challenges. First, the methodology must be relatively simple to integrate successfully with existing models; it must be easily understood, easily applied to the supply-chain models without user intervention, and run quickly. The second challenge is more fundamental: the methodology must account for both upstream and downstream impacts that result from supply-chain disruptions. Input-output modeling typically estimates only upstream impacts, but shortages resulting from disruptions in many supply chains (for example, energy, communications, and chemicals) are likely to have large downstream impacts. In overcoming these challenges, the input-output methodology makes strong assumptions about technology and substitution. This paper concludes by applying the methodology to chemical supply chains.

99 GENERAL AND MISCELLANEOUS↗

Using Third-Party Inspectors in Building Energy Codes Enforcement in India

India is experiencing fast income growth and urbanization, and this leads to unprecedented increases in demand for building energy services and resulting energy consumption. In response to rapid growth in building energy use, the Government of India issued the Energy Conservation Building Code (ECBC) in 2007, which is consistent with and based on the 2001 Energy Conservation Act. ECBC implementation has been voluntary since its enactment and a few states have started to make progress towards mandatory implementation. Rajasthan is the first state in India to adopt ECBC as a mandatory code. The State adopted ECBC with minor additions on March 28, 2011 through a stakeholder process; it became mandatory in Rajasthan on September 28, 2011. Tamil Nadu, Gujarat, and Andhra Pradesh have started to draft an implementation roadmap and build capacity for its implementation. The Bureau of Energy Efficiency (BEE) plans to encourage more states to adopt ECBC in the near future, including Haryana, Uttar Pradesh, Karnataka, Maharashtra, West Bengal, and Delhi. Since its inception, India has applied the code on a voluntary basis, but the Government of India is developing a strategy to mandate compliance. Implementing ECBC requires coordination between the Ministry of Power and the Ministry of Urban Development at the national level as well as interdepartmental coordination at the state level. One challenge is that the Urban Local Bodies (ULBs), the enforcement entities of building by-laws, lack capacity to implement ECBC effectively. For example, ULBs in some states might find the building permitting procedures to be too complex; in other cases, lack of awareness and technical knowledge on ECBC slows down the amendment of local building by-laws as well as ECBC implementation. The intent of this white paper is to share with Indian decision-makers code enforcement approaches: through code officials, third-party inspectors, or a hybrid approach. Given the limited capacity and human resources available in the state and local governments, involving third-party inspectors could rapidly expand the capacity for plan reviews and broad implementation. However, the procedures of involving third-parties need to be carefully designed in order to guarantee a fair process. For example, there should be multiple checks and certification requirements for third-party inspectors, and the government should have the final approval when third-party inspectors are used in a project. This paper discusses different approaches of involving third-parties in ECBC enforcement; the Indian states may choose the approaches that work best in their given circumstances.

Yu, Sha↗