The thermal emittance of mica as a function of thickness.
Reflectance, transmittance and absorptance of muscovite type mica as function of thickness measured, using prism and grating spectrophotometers
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Reflectance, transmittance and absorptance of muscovite type mica as function of thickness measured, using prism and grating spectrophotometers
Magnesium fluoride double Rochon prism used as polarizer or analyzer in vacuum UV wavelengths
Boundary migration in melt-grown bicrystals of KCl containing pure twist boundaries was investigated. The experiments involve the use of bicrystal specimens in the shape of right-triangular prisms with the boundary parallel to one side.
Reflectance, transmittance and absorptance of muscovite type mica as function of thickness measured, using prism and grating spectrophotometers
Far UV spectral intensity of B3 V star from Aerobee rocket scanning prism spectrometry, noting discrepancy with model atmosphere predictions
Wide angle objective prism spectrograph for ultraviolet stellar astronomy
Prism plus image amplifier panel provides visual image of many infrared spectral lines from carbon arc impregnated with metal compound. Different metal compounds generate various desired spectra. Panel also aligns and focuses simple spectroscopes for detecting spectral lines inside and outside visible region.
Optical device containing rotatable prism and reflecting mirror for generating precise angles
Optical bonding agent for calcite prism on Pioneer F/G mission, emphasizing optical and mechanical properties resistance to Jupiter high energy particles
Mechanical sterilization and cleansing of Goldmann applanation tonometer prisms contaminated with coliphage, comparing with germicidal immersion
Retinal adaptation to prism-displaced hand image in terms of sensorimotor coordination central control change
Stellar UV cut-off by statospheric nacelle recorded on photographic film by Schmidt telescope fitted with objective prism, widening spectrum by scanning
Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.
Our method of matrix synthesis of optical components and instruments is applied to the derivation of Jones's matrices appropriate for Fourier interferometers (spectrometers and spectropolarimeters). These matrices are obtained for both the source beam and the detector beam. In the course of synthesis, Jones's matrices of the various reflectors (plane mirrors; retroreflectors: roofed mirror, trihedral and prism cube corner, cat's eye) used by these interferometers are also obtained.
An observation of the corona during the 7 March, 1970 eclipse through a Wollaston prism-red and blue filter combination was carried out for the purpose of confirming the prediction that the component of the K-corona with electric vector radial to the Sun is redder than the tangential component. An analysis of a portion of the resulting data seems to confirm this prediction, and also indicates that the method is useful for determining the three-dimensional configuration of the very inner corona. A three-dimensional configuration is suggested for a portion of the NE quadrant of the Sun, including the large NE streamer and an adjacent low-lying loop.
Use of a satellite photometric observatory (SPO) to measure the solar corona from Miahuatlan, Mexico during the Mar. 7, 1970, total eclipse of the sun. The SPO is equipped with a 24-in. Cassegrainian telescope, a four-channel photoelectric photometer, a Wollaston prism, and a rotating half-wave plate. Simultaneous measurements were made of the two orthogonal components of coronal light in the B and R bands of the UBVRI system. A 1-minute arc aperture was scanned from the lunar disk center out to five solar radii in a series of spirals of gradually increasing radius. For the first time, simultaneous multicolor intensity, degree, and angle of polarization profiles are computed from photoelectric measurements. Comparison of the variations of the measurements for each spiral scan yield a detailed picture of the intensity and polarization features in the K corona.
The author has identified the following significant results. This catalogue was prepared as a part of the joint ERTS-1 New Jersey coastal mapping experiment. First look analysis of ERTS-1 images indicates that numerous coastal oceanographic patterns can be mapped on a sequential basis using ERTS-1 images. Analysis of imagery indicates a predominant southwesterly drift of dumped wasted in the surface waters. Initial analysis of imagery indicates that the effects of tidal flushing of New York harbor extend as far south as Long Branch, New Jersey. Analysis of imagery from 3 September, 1972, indicates a wide band of turbid water extending several miles offshore around Barnegat Inlet. First look analysis of imagery from 10 October, 1972, illustrates the increased reflectance of turbid waters within the bays, sounds, and thoroughfares behind the barrier islands in the southern New Jersey shore area. The estuarine waters emanating from both Brigantine and Absecon Inlets are very turbid relative to the waters further offshore and to the north and south. The tidal prism appears to be quite large but the movement of water once outside the inlets is not very rapid. The waters are not moving away from the coastline but rather along the coast.
An optical imaging system for enabling nonabsorbed light imaged onto a photodetective surface to be collected and reimaged one or more times onto that surface in register with the original image. The system includes an objective lens, one or more imaging lenses, one or more retroreflectors and perhaps a prism for providing optical matching of the imaging lens focal planes to the photo detective surface.