Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Pilot plant reliability metrics for grinding and fast pyrolysis of woody residues

Here we report on the effects of loblolly pine residue variability on material throughput, pilot plant uptime, operator intervention, product yield, and product quality for grinding, fast pyrolysis, and hydrotreating operations. Preprocessing throughput using a hammer mill varied between 31-48% of nameplate capacity (5 tons/hr). Grinder overloads in the size reduction step were more prevalent for lower ash and higher moisture materials. Fast pyrolysis throughput varied between 57-72% of nameplate capacity (20 kg/hr) and bio-oil yields varied between 46-53% (feedstock carbon to oil, dry basis). During fast pyrolysis operations, downtime was caused by bridging in the feed and char removal systems and plugging in the condensation system. Cohesion of feedstock and char leading to system plugging was less frequent for higher ash feedstocks, and differences in condenser plugging behavior between high and low ash feedstocks were observed. The catalyst stability of the bio-oil stabilization step was strongly dependent on the sulfur content in the bio-oil, which was higher for the high-ash residue oils. Lower moisture content in the starting biomass was consistent with lower sulfur content in bio-oil. Yields and properties of hydrotreated fuel products showed minimal deference among the bio-oils.

Klinger, Jordan↗

SU-E-J-176: Results of Images Acquired with Backscattered MV Radiation Using a Pinhole Collimator

Purpose: To ascertain the feasibility of acquiring real time images of small lung tumors from scattered photons while undergoing radiation treatment.There are several methodologies currently used to track tumor location such as MV-cine acquisition and kV fluoroscopy. However, MVcine offers no information parallel to the beam axis while kV fluoroscopy offers little potential for soft tissue discernability while also increasing the patient dose. This study investigates the feasibility of observing an actual simulated tumor while exploring techniques that may improve image quality. Methods: A prototype imager consisting of a gamma camera pinhole collimator and a computed radiography (CR) plate were used in conjunction with a Varian TrueBeam linac. One study consisted of a 2.5 cm diameter solid water cylinder representing a solid tumor imbedded within a lung equivalent material slab. The cylinder with the lung slab was sandwiched between 1 cm lung equivalent slabs and these were sandwiched between 2 slabs of solid water. The top water slab was 1 cm thick. The other imaging study consisted of three different density plugs, 0.46, 1.09, and 1.82 g/cm3 placed on the accelerator couch. The gantry was orientated 70° relative to the CR plate. The slabs and plugs were irradiated with 2000 MU and 500 MU respectively using the 6FFF mode. Results: The solid water plug was visually discernible in the slab phantom. The ratio of the signal coming from the higher density plugs (placed on the treatment couch) to that between the plugs increased from 1.02 to about 3.0 after subtracting the background image acquired with no plugs present. Conclusion: Preliminary results indicate that a lung tumor could be visualized with scattered radiation during treatment. Improvements in discerning an object can be enhanced by filtering out the head leakage and background scattered radiation not emanating from the imaged object.

60 APPLIED LIFE SCIENCES↗

Interstate Electrification Improvement Project

The Interstate Electrification Improvement Project, publicly known as the Shorepower Truck Electrification Project (STEP), started in May 2011 and ended in March 2015. The project grant was awarded by the Department of Energy’s Vehicles Technology Office in the amount of $22.2 million. It had three overarching missions: 1. Reduce the idling of Class 8 tractors when parked at truck stops, to reduce diesel fuel consumption and thus U.S. dependence on foreign petroleum; 2. Stimulate job creation and economic activity as part of the American Reinvestment and Recovery Act of 2009; 3. Reduce greenhouse gas emissions (GHG) from diesel combustion and the carbon footprint of the truck transportation industry. The project design was straightforward. First, build fifty Truck Stop Electrification (TSE) facilities in truck stop parking lots across the country so trucks could plug-in to 110V, 220V, or 480VAC, and shut down the engine instead of idling. These facilities were strategically located at fifty truck stops along major U.S. Interstates with heavy truck traffic. Approximately 1,350 connection points were installed, including 150 high-voltage electric standby Transport Refrigeration Unit (eTRU) plugs--eTRUs are capable of plugging in to shore power1 to cool the refrigerated trailer for loads such as produce, meats and ice cream. Second, the project provided financial incentives on idle reduction equipment to 5,000 trucks in the form of rebates, to install equipment compatible with shore power. This equipment enables drivers to shut down the main engine when parked, to heat or cool their cab, charge batteries, or use other household appliances without idling—a common practice that uses approximately 1 gallon of diesel per hour. The rebate recipients were intended to be the first fleets to plug into Shorepower to save diesel fuel and ensure there is significant population of shore power capable trucks. This two part project was designed to complement each other by providing: 1) the infrastructure to plug into and 2) the on-board equipment capable of plugging into the infrastructure. This project generated the largest dataset to date on shore power TSE utilization and use patterns, providing: insight into driver behavior and acceptance; evidence of cost savings; experience with system operations and management; and data for guiding future development of shore power, whether as a private enterprise or a publicly-subsidized service for meeting air quality goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decommutator patchboard verifier

A system for automatically verifying the connections between terminals of a patchboard is described. The system includes a back plane having a plurality of plugs corresponding to the pins of the patchboard. A number of decoders are connected to the plugs of the back plane so that a signal can be sequentially applied to each plug of the back plane under control of a stepping register and a control circuit. A plurality of data selectors are also connected to the plugs of the back plane and under control of a second external register. This control circuit sequentially makes connections between an output circuit and the plugs of the back plane so as to patch the signal applied to a respective plug through a patch connection to the output circuit. The precise locations of the patches on the patchboard can be identified and compared with previously stored information in a memory unit.

Brunson, J. W.↗

Joule-Thomson valves for long term service in space cryocoolers

Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.

Lester, J. M.↗

The subsidiary gap as a means for improving ignition

This report was prepared at the Bureau of Standards for the National Advisory Committee for Aeronautics. Additional or subsidiary gaps have frequently been used in jump-spark ignition systems, in order to cause the resumption of sparking in fouled spark plugs. The series gap, to which the greater part of this report is devoted, is a subsidiary gap in the connection between the high tension terminal of the plug and that of the magneto or coil. A brief account is given of the use of this gap up to the present time and also of the statements concerning it which have gained some currency, most of which are shown to be erroneous. The simple theory of the action of the series gap is discussed and a detailed account given of the effect upon the sparking ability of the plug produced by changes in the values of the electrical resistance of the fouling and of the capacities in parallel with the plug and with the magneto or coil. This report presents the results of an investigation into the utility, action, and design of the auxiliary spark gap as a means for insuring freedom from spark plug failure due to fouling, and also to enable the restarting of fouled plugs.

Gorton, W S↗

Dust-tolerant electrical connector

A connector assembly includes releasably mateable plug and receptacle units. At least one socket is enclosed within the receptacle unit and is aligned with at least one permeable membrane disposed in the front end of the receptacle unit. The plug unit includes a body slidably mounted within a longitudinal bore therein. At least one pin extends from the front end of the body and is aligned with at least one permeable membrane disposed in the front end of the plug unit. The plug unit is biased toward a first, de-mate position in which the body is extended rearwardly such that the pin is enclosed with the plug unit and is slidable to a second, mate position in which the body is compressed forwardly such that the pin projects through the permeable membranes of the plug and receptacle units to electrically connect with the socket.

Sadick, Shazad↗

Design of P-3 Nadir Port

This project details the design and analysis of a structure to replace the interface of the P-3B nadir port with an optimized interface for science installations. A new nadir port plug has been designed to replace the OEM (Original Equipment Manufacturer) plug (Lockheed PN 910169) currently used in Nadir ports 1 and 2 on the NASA P-3B aircraft. The plug consists of a milled frame that can be outfitted with customizable flat plates to meet a broad range of science needs. The frame slides into place using the existing P-3B rail system using a lever and tie-rod assembly. The seal interface will contact the Fuselage skin of the aircraft and consists of a bulb E-seal that is riveted around the perimeter of the frame. The flat plate (20 inches x 31 inches) provides a large profile that can be outfitted based on science mission goals and requirements to attach multiple instruments. This is a significant increase to the aircraft capability. Previously, the OEM plug had to be modified to hold very small plates, windows, or instruments limiting the use of the ports.There were several challenges for this project that included a constrained schedule, lack of historical references, and reverse engineering. The unusually tight schedule for design, manufacture, and install limited potential approaches. In addition, design of a new interface to replace the existing plug, on an aircraft designed in the 1960's by Lockheed for the Navy with little to no documentation, required substantial reverse engineering. In order to accomplish this, a suitable method to determine interface requirements with the aircraft had to be solved. After several iterations, the solution was to implement laser scanning techniques to scan the aircraft and the OEM plug and generate a 3D model to capture the design envelope. The structure is designed to maintain a positive margin of safety when subjected to the inertial, pressure, and aerodynamic load requirements for an external installation on the P-3B, as described in the Wallops' P-3B Design Requirements 548-RQMT-0001 Rev. A . A finite element model is created in FEMAP (Finite Element Modeling And Postprocessing) and is run through NX Nastran solver to analyze the structure. After several iterations of analysis, the structure was enveloped to hold 115 pounds evenly distributed on the plate.

Chance, Monica↗

How to reduce Shutdown Dose Rates in ITER Diagnostics Equatorial Ports

The ITER vacuum vessel presents 54 access ports, arranged in three levels, where port plugs are inserted hosting different types of systems: test blanket modules, antennas, vacuum pumps, neutral beam injectors and diagnostics. At the equatorial level, nine out of the eighteen access ports present diagnostics port plugs, in which the diagnostics systems are deployed into three DSMs (Diagnostics Shield Modules). The DSMs, being a major constituent in volume of the port plugs, must help to fulfill the design target of Shutdown Dose Rates (SDDR) corresponding to 100 μSv.h{sup -1} after 10{sup 6} s of cooling time for planned in-situ maintenance operations in the port interspace. Additionally, the DSMs are largely responsible for the port plug drained weight limit of 45 T, which imposes limitations to the shielding technology. Up to now, all the proposed DSM designs combine differently stainless steel, water and/or B{sub 4}C as shielding to accommodate a maximum of 1.1 m{sup 3} of DSM bulk shield, contained into a L 1845 x W 518 x H 2011 mm stainless steel box weighting 5.8 T for each DSM. These proposals show insufficient shielding properties with respect to SDDR, while none of them satisfies currently the weight limit. However, during 2016, a new DSM concept has been developed, named 'modular DSM', with significant engineering advances and changes. The DSM length has been increased by 500 mm, up to 2345 mm. The SS box has been reduced to the minimum structure required, presenting the same weight while being larger and hosting a larger volume of bulk shielding inside. Thus, the volume of bulk shielding has been enlarged up to 1.5 m{sup 3} per DSM. The shielding technology is based on B{sub 4}C bricks deployed in SS trays that are attached to the vertical plates. This results in a bulk shielding made of 65% of B{sub 4}C, 10% SS and 25% void, with effective density of 2.4 g.cm{sup -3}. In summary, the modular DSM, without a weight increase, hosts extra 0.5 m3 of bulk shielding along an additional 500 mm of length, to be used with a light but highly neutron absorber, what allows fitting the weight limit of 45 T for the port plug once drained. From now, the non-modular DSMs will be referred as 'short DSMs'. The modular DSM's advantages with respect to the short DSM versions have shown that the DSMs design can be improved in generic approach, i.e. when the penetrations of the systems are not taken into consideration. A mention apart is required when port specific penetrations are considered. Provided that they will be an important radiation transmission path, their presence could significantly diminish the improvement. To clarify this issue, in this work we have carried out a nuclear analysis of the ITER equatorial port no. 11 integration considering the modular DSM. It is a first plasma port hosting the following 6 major diagnostics systems: Neutral Particle Analyzer (NPA), H-α monitor, Low Field Side (LFS) reflectometry, Visible - Ultraviolet divertor (VUV div), Visible - Ultraviolet core survey (VUV CS) and X-rays Crystal System (XRCS). For the baseline case, a SDDR matrix has been derived assigning responsibilities to the different EP no. 11 individual systems in terms of neutron flux transmission through them, and the related activation due to that neutron flux (activation of itself, but also of the rest of systems taken one by one). Different EP no. 11 configurations have been studied in addition to the baseline case. For example, the backfill of the port plug penetrations to protect all the empty space not required for systems sight. Another issue is the determination of the role of the Co impurity content minimization from 0.05 wt.% to 0.03 wt.% recently proposed. In this summary, only some results related to the baseline are given.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shear-driven redistribution of surfactant affects enzyme activity in well-mixed femtoliter droplets

We developed a microfluidic platform for splitting well-mixed, femtoliter-volume droplets from larger water-in-oil plugs, where the sizes of the daughter droplets were not limited by channel width. These droplets were separated from mother plugs at a microfabricated T-junction, which enabled the study of how increased confinement affected enzyme kinetics in droplets 4-10 {mu}m in diameter. Initial rates for enzyme catalysis in the mother plugs and the largest daughter drops were close to the average bulk rate, while the rates in smaller droplets decreased linearly with increasing surface to volume ratio. Rates in the smallest droplets decreased by a factor of 4 compared to the bulk rate. Traditional methods for detecting nonspecific adsorption at the water-oil interface were unable to detect evidence of enzyme adsorption, including pendant drop tensiometry, laser scanning confocal microscopy of drops containing labeled proteins in microemulsions, and epifluorescence microscopy of plugs and drops generated on-chip. We propose the slowing of enzyme reaction kinetics in the smaller droplets was the result of increased adsorption and inactivation of enzymes at the water-oil interface arising from transient interfacial shear stresses imparted on the daughter droplets as they split from the mother plugs and passed through the constricted opening of the T-junction. Such stresses are known to modulate the interfacial area and density of surfactant molecules that can passivate the interface. Bright field images of the splitting processes at the junction indicate that these stresses scaled with increasing surface to volume ratios of the droplets but were relatively insensitive to the average flow rate of plugs upstream of the junction.

59 BASIC BIOLOGICAL SCIENCES↗

Technology Improvement Pathways to Cost-Effective Vehicle Electrification

Electrifying transportation can reduce or eliminate dependence on foreign fuels, emission of green house gases, and emission of pollutants. One challenge is finding a pathway for vehicles that gains wide market acceptance to achieve a meaningful benefit. This paper evaluates several approaches aimed at making plug-in electric vehicles (EV) and plug-in hybrid electric vehicles (PHEVs) cost-effective including opportunity charging, replacing the battery over the vehicle life, improving battery life, reducing battery cost, and providing electric power directly to the vehicle during a portion of its travel. Many combinations of PHEV electric range and battery power are included. For each case, the model accounts for battery cycle life and the national distribution of driving distances to size the battery optimally. Using the current estimates of battery life and cost, only the dynamically plugged-in pathway was cost-effective to the consumer. Significant improvements in battery life and battery cost also made PHEVs more cost-effective than today's hybrid electric vehicles (HEVs) and conventional internal combustion engine vehicles (CVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental risks and opportunities of orphaned oil and gas wells in the United States

Abstract Hundreds of thousands of documented and undocumented orphaned oil and gas wells exist in the United States (U.S.). These wells have the potential to contaminate water supplies, degrade ecosystems, and emit methane and other air pollutants. Thus, orphaned wells present risks to climate stability and to environmental and human health, which can be reduced by plugging. To quantify environmental risks and opportunities of well plugging at the national level, we analyze data on 81 857 documented orphaned wells across the U.S. We find that > 4.6 million people live within 1 km of a documented orphaned well. 35% of the documented orphaned wells are located within 1 km of a domestic groundwater well, yet only 8% of the wells have groundwater quality data within a 1 km radius. Methane emissions from the documented orphaned wells represent approximately 3%–6% of total U.S. methane emissions from abandoned oil and gas wells, but this estimate is based on measurements at < 0.03% of U.S. abandoned wells. 91% of the documented orphaned wells overlie formations favorable for geologic storage of carbon dioxide and hydrogen, meaning that orphaned well plugging can reduce leakage risks from future storage projects. Finally, we estimate plugging costs for documented orphaned wells to exceed the $4.7 billion federal funding by 30%–80%, emphasizing the importance of prioritizing federal spending on wells with large remediation benefits. Overall, environmental monitoring data are not extensive enough to quantify risks, especially those related to air and water quality and human health. Plugging orphaned wells can provide opportunities for geologic storage of carbon dioxide and hydrogen and geothermal energy development, thereby facilitating efforts to transition to net-zero energy systems. Our analysis on environmental risks and opportunities of orphaned wells provides a framework that can be used to manage the millions of documented and undocumented orphaned wells in the U.S. and abroad.

54 ENVIRONMENTAL SCIENCES↗

Navigating Cybersecurity Implications of Smart Outlets

Plug and process loads (PPLs) consume approximately one third of U.S. buildings' energy budget. As other equipment becomes more efficient, and plug-in devices diversify in the market, the percentage of PPL energy consumption is forecasted to grow. To help combat this growth, new wireless metering and control technologies (also known as 'smart outlets') are helping building owners to collect plug load data, understand usage patterns, and implement controls. Adoption of these new connected technologies motivates serious cybersecurity consideration. Because these new technologies are developing at such a rapid pace, the aim of this paper is to inform thinking about cybersecurity issues and the risks that they impose. Through this lens, we explore the pros and cons of plug load controllers, provide a framework for assessing cybersecurity of connected devices such as plug load controllers, and offer an example of how commercial building owners could use this framework to minimize their cybersecurity risks when adopting smart products. In providing this framework, this paper aims to remove some barriers to implementation of these energy efficient technologies in the built environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fluid Flow, Dissolution, and Mixing Phenomena in Argon-Stirred Steel Ladles

In the current study, the multiphase fluid flow in argon-stirred steel ladles is simulated using an Eulerian–Lagrangian two-phase approach. The momentum source and the turbulent kinetic energy source due to the motion of the bubble are considered for the liquid phase. Argon bubbles are treated as discrete phase particles, and the interfacial forces between the bubbles and the liquid phase; the dependence of the gas density and the bubble diameter on the temperature and the static pressure; and the bubble size distribution are considered. When the fluid flow reaches the quasi-steady state, the ferroalloy melting and mixing phenomena is also modeled. The melting time and the trajectory length of each ferroalloy particle are recorded using a user-defined function (UDF). Local mixing time is predicted in the entire computational domain by checking the mixing criteria in every cell. The effects of gas flow rate, porous plug location, and separation angle of two porous plugs on the fluid flow and the mixing phenomena are investigated. The results show that the flow intensity increases, and the mixing time decreases with the increasing gas flow rate. The optimal porous plug’s radial position with one porous plug is 0.50R for its best mixing condition. When two porous plugs are adopted, the separation angle of 90 deg is recommended to improve the flow field and mixing phenomena.

42 ENGINEERING↗

SU-E-T-391: Evaluation of Image Parameters Impact On the CT Calibration Curve for Proton Therapy

Purpose: The calibration of the Hounsfield units (HU) to relative proton stopping powers (RSP) is a crucial component in assuring the accurate delivery of proton therapy dose distributions to patients. The purpose of this work is to assess the uncertainty of CT calibration considering the impact of CT slice thickness, position of the plug within the phantom and phantom sizes. Methods: Stoichiometric calibration method was employed to develop the CT calibration curve. Gammex 467 tissue characterization phantom was scanned in Tomotherapy Cheese phantom and Gammex 451 phantom by using a GE CT scanner. Each plug was individually inserted into the same position of inner and outer ring of phantoms at each time, respectively. 1.25 mm and 2.5 mm slice thickness were used. Other parameters were same. Results: HU of selected human tissues were calculated based on fitted coefficient (Kph, Kcoh and KKN), and RSP were calculated according to the Bethe-Bloch equation. The calibration curve was obtained by fitting cheese phantom data with 1.25 mm thickness. There is no significant difference if the slice thickness, phantom size, position of plug changed in soft tissue. For boney structure, RSP increases up to 1% if the phantom size and the position of plug changed but keep the slice thickness the same. However, if the slice thickness varied from the one in the calibration curve, 0.5%–3% deviation would be expected depending on the plug position. The Inner position shows the obvious deviation (averagely about 2.5%). Conclusion: RSP shows a clinical insignificant deviation in soft tissue region. Special attention may be required when using a different slice thickness from the calibration curve for boney structure. It is clinically practical to address 3% deviation due to different thickness in the definition of clinical margins.

60 APPLIED LIFE SCIENCES↗

SU-F-T-398: Improving Radiotherapy Treatment Planning Using Dual Energy Computed Tomography Based Tissue Characterization

Purpose: Both kVp settings and geometric distribution of various materials lead to significant change of the HU values, showing the largest discrepancy for high-Z materials and for the lowest CT scanning kVp setting. On the other hand, the dose distributions around low-energy brachytherapy sources are highly dependent on the architecture and composition of tissue heterogeneities in and around the implant. Both measurements and Monte Carlo calculations show that improper tissue characterization may lead to calculated dose errors of 90% for low energy and around 10% for higher energy photons. We investigated the ability of dual-energy CT (DECT) to characterize more accurately tissue equivalent materials. Methods: We used the RMI-467 heterogeneity phantom scanned in DECT mode with 3 different set-ups: first, we placed high electron density (ED) plugs within the outer ring of the phantom; then we arranged high ED plugs within the inner ring; and finally ED plugs were randomly distributed. All three setups were scanned with the same DECT technique using a single-source DECT scanner with fast kVp switching (Discovery CT750HD; GE Healthcare). Images were transferred to a GE Advantage workstation for DECT analysis. Spectral Hounsfield unit curves (SHUACs) were then generated from 50 to 140-keV, in 10-keV increments, for each plug. Results: The dynamic range of Hounsfield units shrinks with increased photon energy as the attenuation coefficients decrease. Our results show that the spread of HUs for the three different geometrical setups is the smallest at 80 keV. Furthermore, among all the energies and all materials presented, the largest difference appears at high Z tissue equivalent plugs. Conclusion: Our results suggest that dose calculations at both megavoltage and low photon energies could benefit in the vicinity of bony structures if the 80 keV reconstructed monochromatic CT image is used with the DECT protocol utilized in this work.

60 APPLIED LIFE SCIENCES↗

PDC IC Weld Failure Evaluation and Resolution

During final preparations for start of the PDCF Inner Can (IC) qualification effort, welding was performed on an automated weld system known as the PICN. During the initial weld, using a pedigree canister and plug, a weld defect was observed. The defect resulted in a hole in the sidewall of the canister, and it was observed that the plug sidewall had not been consumed. This was a new type of failure not seen during development and production of legacy Bagless Transfer Cans (FB-Line/Hanford). Therefore, a team was assembled to determine the root cause and to determine if the process could be improved. After several brain storming sessions (MS and T, R and D Engineering, PDC Project), an evaluation matrix was established to direct this effort. The matrix identified numerous activities that could be taken and then prioritized those activities. This effort was limited by both time and resources (the number of canisters and plugs available for testing was limited). A discovery process was initiated to evaluate the Vendor's IC fabrication process relative to legacy processes. There were no significant findings, however, some information regarding forging/anneal processes could not be obtained. Evaluations were conducted to compare mechanical properties of the PDC canisters relative to the legacy canisters. Some differences were identified, but mechanical properties were determined to be consistent with legacy materials. A number of process changes were also evaluated. A heat treatment procedure was established that could reduce the magnetic characteristics to levels similar to the legacy materials. An in-situ arc annealing process was developed that resulted in improved weld characteristics for test articles. Also several tack welds configurations were addressed, it was found that increasing the number of tack welds (and changing the sequence) resulted in decreased can to plug gaps and a more stable weld for test articles. Incorporating all of the process improvements for the actual can welding process, however, did not result in an improved weld geometry. Several possibilities for the lack of positive response exist, some of which are that (1) an insufficient number of test articles were welded under prototypic conditions, (2) the process was not optimized so that significant improvements were observable over the "noise", and (3) the in-situ arc anneal closed the gap down too much so the can was unable to exhaust pressure ahead of the weld. Several operational and mechanical improvements were identified. The weld clamps were changed to a design consistent with those used in the legacy operations. A helium puff operation was eliminated; it is believed that this operation was the cause of the original weld defect. Also, timing of plug mast movement was found to correspond with weld irregularities. The timing of the movement was changed to occur during weld head travel between tacks. In the end a three sequential tack weld process followed by a pulse weld at the same current and travel speed as was used for the legacy processes was suggested for use during the IC qualification effort. Relative to legacy welds, the PDC IC weld demonstrates greater fluctuation in the region of the weld located between tack welds. However, canister weld response (canister to canister) is consistent and with the aid of the optical mapping system (for targeting the cut position) is considered adequate. DR measurements and METs show the PDC IC welds to have sufficient ligament length to ensure adequate canister pressure/impact capacity and to ensure adequate stub function. The PDC welding process has not been optimized as a result of this effort. Differences remain between the legacy BTC welds and the PDC IC weld, but these differences are not sufficient to prevent resumption of the current PDC IC qualification effort. During the PDC IC qualification effort, a total of 17 cans will be welded and a variety of tests/inspections will be performed. The extensive data collected during that qualification effort should be of a sufficient population to determine if additional weld process optimization is necessary prior to production release.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iron Mountain Electromagnetic Results

Iron Mountain Mine is located seventeen miles northwest of Redding, CA. After the completion of mining in early 1960s, the mine workings have been exposed to environmental elements which have resulted in degradation in water quality in the surrounding water sheds. In 1985, the EPA plugged ore stoops in many of the accessible mine drifts in an attempt to restrict water flow through the mine workings. During this process little data was gathered on the orientation of the stoops and construction of the plugs. During the last 25 years, plugs have begun to deteriorate and allow acidic waters from the upper workings to flow out of the mine. A team from Idaho National Laboratory (INL) performed geophysical surveys on a single mine drift and 3 concrete plugs. The project goal was to evaluate several geophysical methods to determine competence of the concrete plugs and orientation of the stopes.

58 GEOSCIENCES↗